Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EXCHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Upgrading and extended testing of the MSC integrated water and waste management hardware

The results are presented of upgrading and testing an integrated water and waste management system, which uses the compression distillation, reverse osmosis, adsorption filtration and ion-exchange processes to recover potable water from urine, flush water and used wash water. Also included is the development of techniques for extending the useful biological life of biological filters, activated carbon filters and ion-exchange resins to at least 30 days, and presterilizing ion-exchange resins so that sterile water can be recovered from waste water. A wide variety of reverse osmosos materials, surfactants and germicides were experimentally evaluated to determine the best combination for a wash water subsystem. Full-scale module tests with real wash water demonstrated that surface fouling is a major problem.

Bambenek, R. A.↗

Current Efforts in Immobilized Low-Activity Waste Glass Testing to Support the Hanford Site Integrated Disposal Facility - 17119

Cleanup plans for Hanford site high-level radioactive mixed tank waste calls for separating the waste into high-level waste (HLW) and low-activity waste (LAW) fractions. The fractions will be vitrified separately at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The HLW glass will be sent to an offsite geological disposal facility while the immobilized low-activity waste (ILAW) glass will be disposed at the onsite Integrated Disposal Facility (IDF). In order to inform models used to predict the performance of ILAW glass at IDF, it is necessary to understand the corrosion behavior of the glass. In this paper, we discuss tests that account for the effects of 1) solution chemistry, 2) the ion exchange reaction, and 3) secondary phase formation on the glass dissolution rate. To quantify the effects of solution chemistry, specifically changes in pH, T, and Si concentration, the single-pass flow-through (SPFT) test method is applied. A designed set of these tests results in a set of kinetic rate law parameters that are used in a glass dissolution rate law based on transition-state theory. Furthermore, for SPFT tests with relatively high concentrations of Si, an ion exchange rate is provided. Additionally, through tests such as the pressurized unsaturated flow (PUF) test method, a suite of secondary phases can be compiled. The collection of kinetic rate law parameters, the ion exchange term, and the suite of secondary phases are provided to IDF performance assessment (PA) modelers. Lastly, we present a description of the efforts made to verify and validate the use of these parameters and secondary phases through the use of a field lysimeter present at the Hanford site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Simulation of Two-grid Ion Optics Using a 3D Code

A three-dimensional ion optics code has been developed under NASA's Project Prometheus to model two grid ion optics systems. The code computes the flow of positive ions from the discharge chamber through the ion optics and into the beam downstream of the thruster. The rate at which beam ions interact with background neutral gas to form charge exchange ions is also computed. Charge exchange ion trajectories are computed to determine where they strike the ion optics grid surfaces and to determine the extent of sputter erosion they cause. The code has been used to compute predictions of the erosion pattern and wear rate on the NSTAR ion optics system; the code predicts the shape of the eroded pattern but overestimates the initial wear rate by about 50%. An example of use of the code to estimate the NEXIS thruster accelerator grid life is also presented.

ion optics↗

Tracking radioactivity content in the spent fuel pool in PWRS - 15150

Over the last decade, significant progress has been made in managing radioisotopes generated in the PWR primary systems. These include limiting the use of cobalt containing materials, along with improved fuel performance and zinc injection to passivate the corrosion layers to limit the accumulation of Co-58 and Co-60 on primary coolant surfaces. Attention here is directed to the spent fuel pool where accumulation of spent fuel and activated material represents a growing source of mobile radioactivity supplemented with periodic exchanges of water from the reactor cooling system. Characterization of this source is increasingly important to effective management of disposal options. This paper examines the radioactive resin source term as determined from routine sampling of the coolant and fuel pool liquids. Targeted resin stream sampling and radiochemical analyses conducted at Diablo Canyon serve to inform and provide context for this examination. This examination is supplemented with computer modelling using the DW James Consulting computer program, 3R-SCAN. At most operating plants daily reactor coolant samples are counted using gamma spectroscopy and recorded. These samples serve to track fuel performance and maintain water chemistry. A secondary use for this data is to maintain a day to day tracking of releases of radioisotopes important to waste disposal. Given the coolant concentrations, plant operating history, and corroborative mathematical models and sampling, accumulation of these radioisotopes in coolant cleanup system ion-exchangers can be predicted. Fuel pool sampling is less frequent, but at the same time, things change more slowly there. The fuel pool contains about ten times the volume of the reactor coolant but its cleanup system process rate is comparable to reactor coolant letdown, i.e. 5.047 - 8.833 liters per second [lps] (80-140 gallons per minute [gpm]). A spent fuel pool clean-up demineralizer flow rate is typically about 5.047 lps (80 gpm). Concentrations of longer lived radioisotopes in the spent fuel pool can be comparable to those in reactor coolant. Releases of corrosion products and fission products from the stored fuel occur at a low rate but given the overall inventory can be significant. Recognized scaling factor ratios, particularly those to Co-60, are skewed by the aging of the material in the pool. An additional consideration stems from refueling operations themselves. Prior to refueling, it is common practice to conduct a forced oxidation of the corrosion films within the reactor. This spikes the activity within the reactor coolant. Most of this activity is removed by the reactor coolant purification system prior to removing the reactor head. This paper examines the accumulation of activity in the fuel pool purification ion exchange resins and how it impacts the overall classification of those ion exchange resins. The following discussion focuses on the transport of nickel and cobalt isotopes particularly as it relates to determination of Ni-63 which has become increasingly prominent in disposal classification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Activity Waste Feed Solids Characterization and Filterability Tests

The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for the WTP Pretreatment facility is to treat the waste, splitting it into High Level Waste (HLW) feed and Low Activity Waste (LAW) feed. Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium in the WTP Pretreatment facility, so its disposition path is the LAW glass. Options are being explored to immobilize the LAW portion of the tank waste, i.e., the LAW feed from the WTP Pretreatment facility. Removal of 99 Tc from the LAW Feed, followed by off-site disposal of the 99 Tc, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for LAW treatment and disposal that could benefit from technetium removal. One of these flow-sheets will specifically examine removing 99 Tc from the LAW feed stream to supplemental immobilization. The conceptual flow sheet of the 99 Tc removal process includes a filter to remove insoluble solids prior to processing the stream in an ion exchange column, but the characteristics and behavior of the liquid and solid phases has not previously been investigated. This report contains results of testing of a simulant that represents the projected composition of the feed to the Supplemental LAW process. This feed composition is not identical to the aqueous tank waste fed to the Waste Treatment Plant because it has been processed through WTP Pretreatment facility and therefore contains internal changes and recycle streams that will be generated within the WTP process. Although a Supplemental LAW feed simulant has previously been prepared, this feed composition differs from that simulant because those tests examined only the fully soluble aqueous solution at room temperature, not the composition formed after evaporation, including the insoluble solids that precipitate after it cools. The conceptual flow sheet for Supplemental LAW immobilization has an option for removal of 99 Tc from the feed stream, if needed. Elutable ion exchange has been selected for that process. If implemented, the stream would need filtration to remove the insoluble solids prior to processing in an ion exchange column. The characteristics, chemical speciation, physical properties, and filterability of the solids are important to judge the feasibility of the concept, and to estimate the size and cost of a facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Topotactic synthesis, structure and magnetic properties of a new hexagonal polytype of silver cobaltate(III) AgCoO{sub 2+{delta}}

A new form of delafossite-type AgCoO{sub 2+{delta}} was prepared using ion exchange from Na{sub 0.75}CoO{sub 2} in molten AgNO{sub 3}-NH{sub 4}NO{sub 3} at 175 deg. C. Its structure was determined by the Rietveld refinement from X-ray powder diffraction measurements (XRD) data; it is hexagonal, space group P6{sub 3}/mmc, a=2.871 and c=12.222 A. Its structure differs from previously reported AgCoO{sub 2} (R3-barm, 3R polytype) by the stacking of Co-O layers; in the new phase, the 2H stacking of the precursor Na{sub 0.75}CoO{sub 2} is consistent with a topotactic ion exchange of Na by Ag. The new phase is found to contain a slight oxygen excess ({delta}=0.06). Magnetic susceptibility measurements show the absence of magnetic transition and a weak Curie term, consistent with the non-magnetic character of Co{sup 3+} ions. - Graphical abstract: Comparison of the structures of high-temperature AgCoO{sub 2} (left, 3R structure) and of new AgCoO{sub 2+{partial_derivative}}(IE) (right, 6H structure). The latter is obtained topotactically from Na{sub 0.7}CoO{sub 2} by ion exchange in molten nitrates. Detailed studies showed that AgCoO{sub 2+{partial_derivative}}(IE) is slightly over-stoichiometric in oxygen ({partial_derivative}=0.06)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supramolecular Control of Redox-Mediated Interactions for Ion-Selective Electroseparations

This report summarizes efforts from the Su Group at the University of Illinois at Urbana-Champaign in researching and developing materials and processes for the recovery of rare earth elements and other metal elements that are critical to the United States economy and national security, under DOE Award No. DE-SC0021409. This report highlights efforts in the recovery of: • Transition metal elements (including arsenic, chromium, molybdenum, rhenium, vanadium): Redox-active metallopolymers are able to capture these elements in their oxyanion form. Direct control of target ion capture/release through electrochemical-mediated switching of metallocene binding sites reduces chemical input and lowers generation of waste in element recovery processes. We study the effects of metallopolymer structure on targeted ion binding through a combination of experimental screening of ion selectivity from multi-component mixtures, computational efforts which elucidate the charge-transfer origins of metallocene binding and provide insight on how binding site structure influences selectivity, and state-of-the-art neutron reflectivity of metallocene polymer films to understand the interplay of polymer-ion (charge-transfer), polymer-solvent (polymer hydrophilicity/hydrophobicity), and ion-solvent (ion hydration) interactions with spatial resolution of polymer films. • Rare earth elements (including yttrium, neodymium, europium, gadolinium, dysprosium, cerium): Here we employ redox-copolymers for recovery of rare earth elements by electrochemically regenerated ion-exchange. Rare earth elements require an alternative route to capture/release than directly with metallopolymers since rare earth elements typically exist in cationic form in water. To address this, copolymerization of traditional ion-exchange moieties with metallocene moieties allowed for capture of rare earth elements with the ion-exchange moieties and electrochemical-mediated release of rare earth elements through oxidation of metallocene moieties.

36 MATERIALS SCIENCE↗

Intercalation and controlled release properties of vitamin C intercalated layered double hydroxide

Two drug-inorganic composites involving vitamin C (VC) intercalated in Mg–Al and Mg–Fe layered double hydroxides (LDHs) have been synthesized by the calcination–rehydration (reconstruction) method. Powder X-ray diffraction (XRD), Fourier transform infrared (FTIR), and UV–vis absorption spectroscopy indicate a successful intercalation of VC into the interlayer galleries of the LDH host. Studies of VC release from the LDHs in deionised water and in aqueous CO{sub 3}{sup 2−} solutions imply that Mg{sub 3}Al–VC LDH is a better controlled release system than Mg{sub 3}Fe–VC LDH. Analysis of the release profiles using a number of kinetic models suggests a solution-dependent release mechanism, and a diffusion-controlled deintercalation mechanism in deionised water, but an ion exchange process in CO{sub 3}{sup 2−} solution. - Graphical abstract: Vitamin C anions have been intercalated in the interlayer space of layered double hydroxide and released in CO{sub 3}{sup 2−} solution and deionised water. - Highlights: • Vitamin C intercalated Mg–Al and Mg–Fe layered double hydroxides were prepared. • Release property of vitamin C in aqueous CO{sub 3}{sup 2−} solution is better. • Avrami-Erofe’ev and first-order models provide better fit for release results. • Diffusion-controlled and ion exchange processes occur in deionised water. • An ion exchange process occurs in CO{sub 3}{sup 2−} solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A structural coarse-grained model for clays using simple iterative Boltzmann inversion

Cesium-137 is a crucial byproduct of nuclear energy generation and is environmentally threatening due to its long half-life and affinity for naturally occurring micaceous clays. Current experimental observations of illite and phlogopite mica indicate that Cs+ is capable of exchanging with K+ bound in the anhydrous interlayers of layered silicates, forming sharp exchange fronts, leading to interstratification of Cs- and K-illite. We introduce here a coarse-grained (CG) model of the anhydrous illite interlayer developed using iterative Boltzmann inversion that qualitatively and quantitatively reproduces features of a previously proposed feedback mechanism of ion exchange. The CG model represents a 70-fold speedup over all-atom models of clay systems and predicts interlayer expansion for K-illite near ion exchange fronts. Contrary to the longstanding theory that ion exchange in a neighboring layer increases the binding of K in lattice counterion sites leading to interstratification, we find that the presence of neighboring exchanged layers leads to short-range structural relaxations that increase basal spacing and decrease cohesion of the neighboring K-illite layers. We also provide evidence that the formation of alternating Cs- and K-illite interlayers (i.e., ordered interstratification) is both thermodynamically and mechanically favorable compared to exchange in adjacent interlayers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability of the solid electrolyte Li{sub 3}OBr to common battery solvents

Graphical abstract: The stability of the anti-perovskite phase Li{sub 3}OBr has been assessed in a variety of battery solvents. - Highlights: • Lithium stable solid electrolyte Li{sub 3}OBr unstable to polar organic solvents. • Solvation with no dissolution destroys long-range structure. • Ion exchange with protons observed. - Abstract: Recently a new class of solid lithium ion conductors was reported based on the anti-perovskite structure, notably Li{sub 3}OCl and Li{sub 3}OBr. For many beyond lithium-ion battery uses, the solid electrolyte is envisioned to be in direct contact with liquid electrolytes and lithium metal. In this study we evaluated the stability of the Li{sub 3}OBr phase against common battery solvents electrolytes, including diethylcarbonate (DEC) and dimethylcarbonate (DMC), as well as a LiPF{sub 6} containing commercial electrolyte. In contact with battery-grade organic solvents, Li{sub 3}OBr was typically found to be insoluble but lost its crystallinity and reacted with available protons and in some cases with the solvent. A low temperature heat treatment was able to restore crystallinity of the samples; however evidence of proton ion exchange was conserved.

36 MATERIALS SCIENCE↗

Regeneration of anion-exchange resins for cyclic selenium removal from industrial wastewaters

Application of ion exchange for the removal of selenium (Se) oxyanions from industrial wastewaters is often limited by ineffective regeneration of the ion-exchange resins, particularly in complex systems containing competing ions, such as coal-ash leachate containing high-sulfate concentrations and heavy metal ions. Here, in this study, it was first demonstrated that while conventional regeneration with sodium chloride (NaCl) is effective for simulated wastewater, with ∼80% efficiency, NaCl fails to regenerate resin loaded with real industrial wastewater, achieving less than 20% efficiency. To overcome this challenge, a two-step regeneration process was investigated using a sodium carbonate (Na 2 CO 3 ) solution for elution, followed by a NaCl solution for restoration. Compared to the one-step NaCl regeneration, this integrated process restored more than 80% of the resin's capacity with real industrial wastewaters. Beyond demonstrating regeneration performance, this research emphasizes fundamental mechanistic interpretations of the observed regeneration behavior across different water matrices and experimental conditions. Particularly, accounting for pH-dependent carbonate speciation, it is proposed that the elution step exploits the resin's strong affinity for divalent carbonate ions to displace strongly bound contaminants, while the subsequent restoration step relies mainly on the mass action effects of chloride ions to regenerate the resin sites. The protocol was optimized to achieve rapid regeneration (<10 min) using moderate chemical concentrations (0.5 M) in treating real leachate. In batch cyclic experiments, Se regeneration reached nearly complete recovery after five consecutive sorption and desorption cycles, while in the fixed-bed system, the regeneration efficiency remained at approximately 80% after five cycles.

Anion-exchange resin↗

Mathematical Modeling of Cation Contamination in a Proton-exchange Membrane

Transport phenomena in an ion-exchange membrane containing both H+ and K+ are described using multicomponent diffusion equations (Stefan-Maxwell). A model is developed for transport through a Nafion 112 membrane in a hydrogen-pump setup. The model results are analyzed to quantify the impact of cation contamination on cell potential. It is shown that limiting current densities can result due to a decrease in proton concentration caused by the build-up of contaminant ions. An average cation concentration of 30 to 40 percent is required for appreciable effects to be noticed under typical steady-state operating conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Sorption Behavior of Iodate Ions on Calcium Silicate Hydrate under a High Saline Condition - 18176

The sorption behavior of iodate ions on calcium-silicate hydrate (CSH) gel under high saline condition was examined by monitoring the concentrations of iodate ions and chloride ions using ion chromatography and Raman spectroscopy, without drying process. In the sorption experiments, a stable isotope I-127 was used as an alternative of I-129 which is radioactive one. Each sample was synthesized with mixing CaO powder, SiO{sub 2} as fumed silica and NaCl solution. Ca/Si molar ratios of CSH gel were set to 0.4, 0.8, 1.2 and 1.6 (add 0.2, 0.6, 1.0 and 1.4 only L/S = 20), and the concentration of NaCl solution was set to 0 M or 0.6 M for simulating the condition of fresh or saline groundwater. The liquid/solid (L/S) ratios of CSH gel were set to 10, 15 and 20, and the total weight of solid phase was 1.5 g. At the same time, NaIO{sub 3} solution was added to the sample in order to adjust its concentration to 1.0 mM, 0.67 mM and 0.5 mM for each L/S ratios. The synthesis procedure for all samples was conducted in a glove bag filled with nitrogen gas. The curing period was 7, 14, 30, and 60 days at a room temperature (298 K) with shaking at 120 strokes/min. As a results, the concentration of iodate ions in the liquid phase decreased for all samples under experimental conditions. Besides, the sorption behavior of iodate ions were hardly changed by the concentration of NaCl. That is, iodate ions migrated to solid phase in spite of the high concentration of NaCl. The distribution coefficients, Kd, increased as Ca/Si ratio increased, and hardly depended on NaCl concentration. The results of Raman analysis shows that the structure of CSH gel was almost not changed with or without NaCl from the viewpoint of the silicate chain under this condition. These results suggest that a sorption process except for the electrostatic process such as an ion exchange and a complexation exists between CSH gel and iodate ions. Besides, CSH gel might be able to contribute the retardation for the migration of iodate ions without changing its structure, even if the disposal environment are saturated by a high saline groundwater. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast ion charge exchange spectroscopy measurement using a radially injected neutral beam on the large helical device

An experimental technique to investigate fast ion confinement based on charge exchange spectroscopy of H{sub {alpha}}-light was applied to evaluate the confinement property of perpendicular fast ions in large helical device (LHD). Sensitivities of the H{sub {alpha}} spectra to the pitch angles of injected neutral beams (NBs) and these to the angle between the sight line of the measurement and NB injection path are examined. The energy dependence of the charge exchange cross section significantly affects the observed spectra since the driving NB is injected perpendicular to the magnetic field lines in the geometry of LHD. The measured spectra are compared to the spectra of GNET simulation results and the simulated spectra agreed well with the experimental measurement when we take into account the contribution of halo neutrals. Although it is difficult to obtain the fast ion distribution functions directly, this technique provides useful experimental data in benchmarking simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Candidate Low-Temperature Glass Waste Forms for Technetium-99 Recovered from Hanford Effluent Management Facility Evaporator Concentrate

Alternative treatment and disposition options may exist for technetium-99 (99Tc) in secondary liquid waste from the Hanford Direct-Feed Low-Activity Waste (DFLAW) process. One approach includes development of an alternate glass waste form that is suitable for on-site disposition of technetium, including salts and other species recovered by ion exchange or precipitation from the EMF evaporator concentrate. By recovering the Tc content from the stream, and not recycling the treated concentrate, the DFLAW process can potentially be operated in a more efficient manner that lowers the cost to the Department of Energy. This report provides a survey of candidate glass formulations and glass-making processes that can potentially incorporate technetium at temperatures <700 °C to avoid volatilization. Three candidate technetium feed streams are considered: (1) dilute sodium pertechnetate loaded on a non-elutable ion exchange resin; (2) dilute sodium-bearing aqueous eluent from ion exchange recovery of pertechnetate, or (3) technetium(IV) oxide precipitate containing Sn and Cr solids in an aqueous slurry. From the technical literature, promising candidate glasses are identified based on their processing temperatures and chemical durability data. The suitability and technical risk of three low-temperature glass processing routes (vitrification, encapsulation by sintering into a glass composite material, and sol-gel chemical condensation) for the three waste streams was assessed, based on available low-temperature glass data. For a subset of candidate glasses, their long-term thermodynamic behavior with exposure to water and oxygen was modeled using Geochemist’s Workbench, with and without addition of reducing stannous ion. For further evaluation and development, encapsulation of precipitated TcO2/Sn/Cr in a glass composite material based on lead-free sealing glasses is recommended as a high priority. Vitrification of pertechnetate in aqueous anion exchange eluent solution using a high lead content borate glass, or other low melting glass is also recommended for further evaluation and development. Additional laboratory studies of phase behavior and chemical durability of low-temperature glasses is also recommended to provide risk mitigation if one of the primary development paths proves infeasible. This report is a deliverable for the task “Candidate Low-T Glass Waste Forms for EMF Bottoms On-Site Disposition Alternative Option.”

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Basis for Savannah River Tank Closure Cesium Removal Project - 17448

Westinghouse is currently executing a contract, awarded in June 2016 from Savannah River Remediation LLC, to deliver a system capable of removing solids and up to 100,000 curies of Cesium-137 from tank 10H, located in the Savannah River 'tank farm'. Savannah River Remediation currently has the responsibility to perform work for the Savannah River Site Liquid Waste Operations Program at the Savannah River Site for the US government, represented by the US DOE under their Principal contract. The scope of work covers the detailed design, procurement, fabrication, and delivery of the system to the Savannah River Site. It also includes the factory acceptance testing of the system, prior to delivery to site. Before leaving the site, Westinghouse will perform an evaluation of the system assembly and operations training for the incumbent operator. The basis for the technology chosen to accomplish the solids and Cesium-137 removal is unique to the specific feed stream, but is based on well-known and successful technology, Toshiba SARRY water cleanup system. Toshiba is Westinghouse's parent company, allowing us to reach back and incorporate the lessons learned during the water cleanup at Fukushima Daiichi and the integration of various technologies. Another key to the technology basis was the ion exchange media selection. A number of possible ion exchange media for the cesium removal were considered with the final choice being inorganic CST resin. Several criteria were considered and compared, such as the radiation sensitivity of the CST and the cesium specific ion preference. This paper will present the conceptual design of the modular system, noting the key benefits of specific components in the overall technology basis. Along with the design, a look at key technology improvements carried into the design through the Toshiba SARRY system will be incorporated. A first feedback on the implementation of the overall project will be provided. Since this system is a first-of-a-kind in this specific application, interesting lessons learned will be provided for future tank closure activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure and stability of alkali gallates structurally reminiscent of hollandite

Abstract Single crystals of CsGa 7 O 11 , RbGa 7 O 11 , and RbGa 4 In 5 O 14 were grown from alkali halide melts and their structures were characterized by single crystal and powder X‐ray diffraction. CsGa 7 O 11 and RbGa 7 O 11 adopt the same structure type, reminiscent of the hollandite structure type, as it contains nearly rectangular channels made up of two dimers of edge‐sharing GaO 6 octahedra, and two corner‐sharing octahedron/tetrahedron pairs. The structure of RbGa 4 In 5 O 14 is more complex and is comprised of indium octahedra, gallium trigonal bipyramids, and gallium tetrahedra, and contains similar sized tunnels as CsGa 7 O 11 and RbGa 7 O 11 . CsGa 7 O 11 and RbGa 4 In 5 O 14 were further characterized by TGA, ion exchange experiments, and DFT studies revealing that both structures are thermodynamically stable up to 850°C; however, CsGa 7 O 11 decomposes to GaO(OH) xH 2 O when heated in warm aqueous solutions. CsGa 7 O 11 undergoes ion exchange in both an aqueous solution of RbCl and a RbNO 3 melt, as predicted by DFT studies, where the ion exchange is more extensive in the RbNO 3 melt.

Juillerat, Christian A.↗