Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Application of Shift Ex-Core Calculations to a Detailed MSR Model

This report documents the collaborative research conducted between Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL) on applying the Monte Carlo neutronics code Shift to calculate the radiation dose rates for a detailed molten salt reactor (MSR) model based on the Molten Salt Breeder Reactor (MSBR). In this work scope, the ANL and ORNL teams worked together and applied Shift to calculate the radiological environments of this detailed MSR facility modeled with explicit geometries. The radiological conditions within the MSR facility were modeled for when the reactor is at two different operation modes: normal full power and drained state. The FW-CADIS hybrid method in Shift was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Dose rate maps showed that in the current MSBR numerical model, potential pathways exist for neutrons and gammas to stream through the 8-foot concrete shield to reach the top of the MSBR reactor cell. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the Shift simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates, which suggests that a steel liner in the tank model must be added for calculating the dose rates in the drain cell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Monte Carlo code SHIFT for MSBR dose rate calculations

This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution can be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.

07 ISOTOPE AND RADIATION SOURCES↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Simplified field-in-field technique for a large-scale implementation in breast radiation treatment

We wanted to evaluate a simplified 'field-in-field' technique (SFF) that was implemented in our department of Radiation Oncology for breast treatment. This study evaluated 15 consecutive patients treated with a simplified field in field technique after breast-conserving surgery for early-stage breast cancer. Radiotherapy consisted of whole-breast irradiation to the total dose of 50 Gy in 25 fractions, and a boost of 16 Gy in 8 fractions to the tumor bed. We compared dosimetric outcomes of SFF to state-of-the-art electronic surface compensation (ESC) with dynamic leaves. An analysis of early skin toxicity of a population of 15 patients was performed. The median volume receiving at least 95% of the prescribed dose was 763 mL (range, 347-1472) for SFF vs. 779 mL (range, 349-1494) for ESC. The median residual 107% isodose was 0.1 mL (range, 0-63) for SFF and 1.9 mL (range, 0-57) for ESC. Monitor units were on average 25% higher in ESC plans compared with SFF. No patient treated with SFF had acute side effects superior to grade 1-NCI scale. SFF created homogenous 3D dose distributions equivalent to electronic surface compensation with dynamic leaves. It allowed the integration of a forward planned concomitant tumor bed boost as an additional multileaf collimator subfield of the tangential fields. Compared with electronic surface compensation with dynamic leaves, shorter treatment times allowed better radiation protection to the patient. Low-grade acute toxicity evaluated weekly during treatment and 2 months after treatment completion justified the pursuit of this technique for all breast patients in our department.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerating iterative ptychography with an integrated neural network

Electron ptychography is a powerful and versatile tool for high-resolution and dose-efficient imaging. Iterative reconstruction algorithms are powerful but also computationally expensive due to their relative complexity and the many hyperparameters that must be optimised. Gradient descent-based iterative ptychography is a popular method, but it may converge slowly when reconstructing low spatial frequencies. Here, in this work, we present a method for accelerating a gradient descent-based iterative reconstruction algorithm by training a neural network (NN) that is applied in the reconstruction loop. The NN works in Fourier space and selectively boosts low spatial frequencies, thus enabling faster convergence in a manner similar to accelerated gradient descent algorithms. We discuss the difficulties that arise when incorporating a NN into an iterative reconstruction algorithm and show how they can be overcome with iterative training. We apply our method to simulated and experimental data of gold nanoparticles on amorphous carbon and show that we can significantly speed up ptychographic reconstruction of the nanoparticles.

4DSTEM↗

SU-E-T-207: Comparison of Integrated Tissue Air Ratio (ITAR) to Traditional TAR for Kilovoltage Pencil-Beams

Purpose: Clinically viable depth dose determination in kilovoltage pencil-beams is a great challenge that resulted in a published dosimetry method called ITAR, which involves measurement of air kerma and attenuation with a detector in a low scatter environment coupled with MCNP scatter calculations. The objective of this work is to compare ITAR to traditional TAR using inherently water-proof microchambers that have only recently become commercially available. Methods: An Exradin A26 microchamber was centered 150 mm from a 100 kVp x-ray source with 2 mm aluminum HVL. Depth dose in water from 16 to 24 mm in 2 mm increments was determined by: (1) placing blocks of Plastic Water LR near the source to minimize scatter and using previously published conversion coefficients [ITAR method] and (2) submerging the detector in a water tank with 2 mm thick Plastic Water LR walls and jogging the tank with motor controllers while keeping the detector position fixed [traditional TAR method]. Each method was repeated four to five times. For each repetition, dose was measured free in-air to normalize the data for exponential regression. Results: Traditional TAR indicated higher depth dose than ITAR; differences ranged from 2.1% at 24 mm depth to 2.5% at 16 mm depth. However, the results of traditional TAR did not include a correction for Pq,cham because it is unknown for this detector type in these conditions. It is estimated that the component of Pq,cham due to the effect of water displacement alone is ∼0.94, but Pq,cham is likely several percent larger than 0.94 due to the energy dependency of the microchamber in the presence of low energy scatter that is not present during in-air calibration. Conclusion: The ITAR method remains preferable for clinical depth dose determination in kilovoltage pencil-beams due to Pq,cham being unknown for suitable detectors in relevant conditions. All four of the authors are either current full time employees, which include stock option grants, or consultants of Oraya Therapeutics Inc.

60 APPLIED LIFE SCIENCES↗

Computed tomography dose measurements with radiochromic films and a flatbed scanner

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6x170 mm{sup 2} in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 deg. - 180 deg. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 deg.) and with the axis beam perpendicular (0 deg. and 180 deg.). Integrating over a 360 deg. exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 {sigma} level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 {sigma} level of 8% were founded. The 1 {sigma} uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 {sigma} uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Preliminary Study of In-House Monte Carlo Simulations: An Integrated Monte Carlo Verification System

Purpose: To develop an infrastructure for the integrated Monte Carlo verification system (MCVS) to verify the accuracy of conventional dose calculations, which often fail to accurately predict dose distributions, mainly due to inhomogeneities in the patient's anatomy, for example, in lung and bone. Methods and Materials: The MCVS consists of the graphical user interface (GUI) based on a computational environment for radiotherapy research (CERR) with MATLAB language. The MCVS GUI acts as an interface between the MCVS and a commercial treatment planning system to import the treatment plan, create MC input files, and analyze MC output dose files. The MCVS consists of the EGSnrc MC codes, which include EGSnrc/BEAMnrc to simulate the treatment head and EGSnrc/DOSXYZnrc to calculate the dose distributions in the patient/phantom. In order to improve computation time without approximations, an in-house cluster system was constructed. Results: The phase-space data of a 6-MV photon beam from a Varian Clinac unit was developed and used to establish several benchmarks under homogeneous conditions. The MC results agreed with the ionization chamber measurements to within 1%. The MCVS GUI could import and display the radiotherapy treatment plan created by the MC method and various treatment planning systems, such as RTOG and DICOM-RT formats. Dose distributions could be analyzed by using dose profiles and dose volume histograms and compared on the same platform. With the cluster system, calculation time was improved in line with the increase in the number of central processing units (CPUs) at a computation efficiency of more than 98%. Conclusions: Development of the MCVS was successful for performing MC simulations and analyzing dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-TeP1-05: Development and Clinical Introduction of Automated Radiotherapy Treatment Planning for Prostate Cancer

Purpose: To develop an automated radiotherapy treatment planning and optimization workflow for prostate cancer in order to generate clinical treatment plans. Methods: A fully automated radiotherapy treatment planning and optimization workflow was developed based on the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). To evaluate our method, a retrospective planning study (n=100) was performed on patients treated for prostate cancer with 5 field intensity modulated radiotherapy, receiving a dose of 35×2Gy to the prostate and vesicles and a simultaneous integrated boost of 35×0.2Gy to the prostate only. A comparison was made between the dosimetric values of the automatically and manually generated plans. Operator time to generate a plan and plan efficiency was measured. Results: A comparison of the dosimetric values show that automatically generated plans yield more beneficial dosimetric values. In automatic plans reductions of 43% in the V72Gy of the rectum and 13% in the V72Gy of the bladder are observed when compared to the manually generated plans. Smaller variance in dosimetric values is seen, i.e. the intra- and interplanner variability is decreased. For 97% of the automatically generated plans and 86% of the clinical plans all criteria for target coverage and organs at risk constraints are met. The amount of plan segments and monitor units is reduced by 13% and 9% respectively. Automated planning requires less than one minute of operator time compared to over an hour for manual planning. Conclusion: The automatically generated plans are highly suitable for clinical use. The plans have less variance and a large gain in time efficiency has been achieved. Currently, a pilot study is performed, comparing the preference of the clinician and clinical physicist for the automatic versus manual plan. Future work will include expanding our automated treatment planning method to other tumor sites and develop other automated radiotherapy workflows.

60 APPLIED LIFE SCIENCES↗

The Effects of Space Radiation on Linear Integrated Circuit

Permanent and transient effects are discussed that are induced in linear integrated circuits by space radiation. Recent developments include enhanced damage at low dose rate, increased damage from protons due to displacement effects, and transients in digital comparators that can cause circuit malfunctions.

space radiation total dose single event upset↗

Global Gene Expression Profiling in Lung Tissues of Rat Exposed to Lunar Dust Particles

The Moon's surface is covered by a layer of fine, potential reactive dust. Lunar dust contain about 1‐2% respirable very fine dust (less than 3 micrometers). The habitable area of any lunar landing vehicle and outpost would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to analyze the dynamics of global gene expression changes in lung tissues of rats exposed to lunar dust particles. F344 rats were exposed for 4 weeks (6h/d; 5d/wk) in nose‐only inhalation chambers to concentrations of 0 (control air), 2.1, 6.8, 21, and 61 mg/m3 of lunar dust. Animals were euthanized at 1 day and 13 weeks after the last inhalation exposure. After being lavaged, lung tissue from each animal was collected and total RNA was isolated. Four samples of each dose group were analyzed using Agilent Rat GE v3 microarray to profile global gene expression of 44K transcripts. After background subtraction, normalization, and log transformation, t tests were used to compare the mean expression levels of each exposed group to the control group. Correction for multiple testing was made using the method of Benjamini, Krieger, and Yekuteli (1) to control the false discovery rate. Genes with significant changes of at least 1.75 fold were identified as genes of interest. Both low and high doses of lunar dust caused dramatic, dose‐dependent global gene expression changes in the lung tissues. However, the responses of lung tissue to low dose lunar dust are distinguished from those of high doses, especially those associated with 61mg/m3 dust exposure. The data were further integrated into the Ingenuity system to analyze the gene ontology (GO), pathway distribution and putative upstream regulators and gene targets. Multiple pathways, functions, and upstream regulators have been identified in response to lunar dust induced damage in the lung tissue.

Yeshitla, Samrawit A.↗

Epidemiologic Study of One Million U.S. Radiation Workers and Veterans

The single most important question in radiation epidemiology is determining the level of health risks associated with radiation exposures that occur gradually over time. The study of one million early U.S. radiation workers and veterans has been designed to provide information on risk following chronic exposures by focusing on occupational groups with differing radiation exposure patterns, including intakes of radionuclides. The cost-efficient study builds on the investments made and foundations laid by investigators and government agencies over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Within the overall goal of the epidemiologic study of one million U.S. radiation workers and veterans, this project had a total of nine specific aims which included studies of six populations for multiple endpoints including cancer overall mortality, leukemia and non-cancer mortality. The six populations included: Mound, Ohio, workers exposed to polonium, tritium and plutonium; nuclear power plant workers within the Landauer dosimetry and Nuclear Regulatory Commission data files; industrial radiographers; Mallinckrodt uranium workers; uranium workers who linked with the US Renal Data System; and nuclear weapons test participants. Over 400,000 workers and atomic veterans are included in these populations, with vital status being determined and analyses of all causes of death undertaken. A critical, integral component of the studies has been comprehensive evaluations of dosimetry involving, in many cases, complex dose reconstructions, and assessments of uncertainties. The work has also involved development of state-of-the art statistical approaches and modeling. All nine aims were accomplished successfully, resulting in publication of two NCRP documents, 13 literature papers, numerous Boice Reports in Health Physics News and many presentations of the work at scientific meetings. Furthermore, recommendations have been developed for an approach to integrate epidemiologic observations with radiation biology for risk assessment and biological models of radiation effect. The results of this project, as well as ongoing epidemiology studies of US radiation workers and veterans, are providing much-needed insights into complex issues regarding cancer and non-cancer health risks from low dose irradiation, how to apply a "dose and dose rate effectiveness factor" to scale the risks from the A-bomb survivor data to current occupational and environmental circumstances, and how to evaluate risk following intakes of radioactive substances. In addition to application to radiation workers, the results of the studies can provide guidance as society debates the role of nuclear energy and deals with nuclear waste, threats of terrorist attacks with nuclear/radiological devices, the remarkable increase in medical exposures to CT scans and nuclear imaging, and to NASA as radiation protection for astronauts on long-duration mission beyond low-Earth orbit is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Use of Multi-Site Radiation Therapy for Systemic Disease Control

Metastatic cancer is a heterogeneous entity, some of which could benefit from local consolidative radiation therapy (RT). Although randomized evidence is growing in support of using RT for oligometastatic disease, a highly active area of investigation relates to whether RT could benefit patients with polymetastatic disease. This article highlights the preclinical and clinical rationale for using RT for polymetastatic disease, proposes an exploratory framework for selecting patients best suited for these types of treatments, and briefly reviews potential challenges. The goal of this hypothesis-generating review is to address personalized multimodality systemic treatment for patients with metastatic cancer. The rationale for using high-dose RT is primarily for local control and immune activation in either oligometastatic or polymetastatic disease. However, the primary application of low-dose RT is to activate distinct antitumor immune pathways and modulate the tumor stroma in efforts to better facilitate T cell infiltration. We explore clinical cases involving high- and low-dose RT to demonstrate the potential efficacy of such treatment. We then group patients by extent of disease burden to implement high- and/or low-dose RT. Patients with low-volume disease may receive high-dose RT to all sites as part of an oligometastatic paradigm. Subjects with high-volume disease (for whom standard of care remains palliative RT only) could be treated with a combination of high-dose RT to a few sites for immune activation, while receiving low-dose RT to several remaining lesions to enhance systemic responses from high-dose RT and immunotherapy. We further discuss how emerging but speculative concepts such as immune function may be integrated into this approach and examine therapies currently under investigation that may help address immune deficiencies. The review concludes by addressing challenges in using RT for polymetastatic disease, such as concerns about treatment planning workflows, treatment times, dose constraints for multiple-isocenter treatments, and economic considerations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

A cradle to grave decontamination process - 15266

As the rate of decommissioning of nuclear facilities is accelerating there is an ever increasing need for technologies which will decrease dose to operators, reduce overall cost and allow minimization of waste volumes. A new fully integrated decontamination and waste management process is described herein. This method approaches surface decontamination in an integrated fashion in that it deals with the full cycle of the process including the final disposition of the secondary wastes generated during the cleaning cycle. This approach also simplifies decontamination in that it addresses issues observed in previous chemical decontamination applications such as generation of orphan wastes and the requirements for multi-step reagent additions over repeated cycles. The waste management aspect of this system is key to providing a fully integrated process and deals with the issues related to grout formulations in the presence of high waste loadings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗