Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INFRARED SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

Ischemia causes muscle fatigue

The purpose of this investigation was to determine whether ischemia, which reduces oxygenation in the extensor carpi radialis (ECR) muscle, causes a reduction in muscle force production. In eight subjects, muscle oxygenation (TO2) of the right ECR was measured noninvasively and continuously using near infrared spectroscopy (NIRS) while muscle twitch force was elicited by transcutaneous electrical stimulation (1 Hz, 0.1 ms). Baseline measurements of blood volume, muscle oxygenation and twitch force were recorded continuously, then a tourniquet on the upper arm was inflated to one of five different pressure levels: 20, 40, 60 mm Hg (randomized order) and diastolic (69 +/- 9.8 mm Hg) and systolic (106 +/- 12.8 mm Hg) blood pressures. Each pressure level was maintained for 3-5 min, and was followed by a recovery period sufficient to allow measurements to return to baseline. For each respective tourniquet pressure level, mean TO2 decreased from resting baseline (100% TO2) to 99 +/- 1.2% (SEM), 96 +/- 1.9%, 93 +/- 2.8%, 90 +/- 2.5%, and 86 +/- 2.7%, and mean twitch force decreased from resting baseline (100% force) to 99 +/- 0.7% (SEM), 96 +/- 2.7%, 93 +/- 3.1%, 88 +/- 3.2%, and 86 +/- 2.6%. Muscle oxygenation and twitch force at 60 mm Hg tourniquet compression and above were significantly lower (P < 0.05) than baseline value. Reduced twitch force was correlated in a dose-dependent manner with reduced muscle oxygenation (r = 0.78, P < 0.001). Although the correlation does not prove causation, the results indicate that ischemia leading to a 7% or greater reduction in muscle oxygenation causes decreased muscle force production in the forearm extensor muscle. Thus, ischemia associated with a modest decline in TO2 causes muscle fatigue.

Non-NASA Center↗

Physiological response to submaximal isometric contractions of the paravertebral muscles

STUDY DESIGN: Brief (30-second) isometric trunk extensions at 5%, 20%, 40%, 60%, and 80% of maximal voluntary contraction (MVC) and 3 minutes of prolonged trunk extension (20% MVC) in erect position were studied in nine healthy male subjects. OBJECTIVES: To investigate the intercorrelation between intramuscular pressure and tissue oxygenation of the paravertebral muscles during submaximal isometric contractions and further, to evaluate paravertebral electromyogram and intramuscular pressure as indicators of force development. SUMMARY OF BACKGROUND DATA: Local physiologic responses to muscle contraction are incompletely understood. METHODS: Relative oxygenation was monitored with noninvasive near-infrared spectroscopy, intramuscular pressure was measured with a transducer-tipped catheter, and surface electromyogram was monitored at three recording sites. RESULTS: The root mean square amplitudes of the paravertebral electromyogram (L4, left and right; T12, right) and intramuscular pressure measured in the lumbar multifidus muscle at L4 increased with greater force development in a curvilinear manner. A significant decrease in the oxygenation of the lumbar paravertebral muscle in response to muscle contraction was found at an initial contraction level of 20% MVC. This corresponded to a paravertebral intramuscular pressure of 30-40 mm Hg. However, during prolonged trunk extension, no further decrease in tissue oxygenation was found compared with the tissue oxygenation level at the end of the brief contractions, indicating that homeostatic adjustments (mean blood pressure and heart rate) over time were sufficient to maintain paravertebral muscle oxygen levels. CONCLUSION: At a threshold intramuscular pressure of 30-40 mm Hg during muscle contraction, oxygenation in the paravertebral muscles is significantly reduced. The effect of further increase in intramuscular pressure on tissue oxygenation over time may be compensated for by an increase in blood pressure and heart rate. Surface electromyogram amplitudes and intramuscular pressure can be used as indicators of paravertebral muscle force.

NASA Center ARC↗

Intramuscular deoxygenation during exercise in patients who have chronic anterior compartment syndrome of the leg

Currently, the definitive diagnosis of chronic compartment syndrome is based on invasive measurements of intracompartmental pressure. We measured the intramuscular pressure and the relative oxygenation in the anterior compartment of the leg in eighteen patients who were suspected of having chronic compartment syndrome as well as in ten control subjects before, during, and after exercise. Chronic compartment syndrome was considered to be present if the intramuscular pressure was at least fifteen millimeters of mercury (2.00 kilopascals) before exercise, at least thirty millimeters of mercury (4.00 kilopascals) one minute after exercise, or at least twenty millimeters of mercury (2.67 kilopascals) five minutes after exercise. Changes in relative oxygenation were measured with use of the non-invasive method of near-infrared spectroscopy. In all patients and subjects, there was rapid relative deoxygenation after the initiation of exercise, the level of oxygenation remained relatively stable during continued exercise, and there was reoxygenation to a level that exceeded the pre-exercise resting level after the cessation of exercise. During exercise, maximum relative deoxygenation in the patients who had chronic compartment syndrome (mean relative deoxygenation [and standard error], -290 +/- 39 millivolts) was significantly greater than that in the patients who did not have chronic compartment syndrome (-190 +/- 10 millivolts) and that in the control subjects (-179 +/- 14 millivolts) (p < 0.05 for both comparisons). In addition, the interval between the cessation of exercise and the recovery of the pre-exercise resting level of oxygenation was significantly longer for the patients who had chronic compartment syndrome (184 +/- 54 seconds) than for the patients who did not have chronic compartment syndrome (39 +/- 19 seconds) and the control subjects (33 +/- 10 seconds) (p < 0.05 for both comparisons).

NASA Discipline Musculoskeletal↗

Alpha-helical hydrophobic polypeptides form proton-selective channels in lipid bilayers

Proton translocation is important in membrane-mediated processes such as ATP-dependent proton pumps, ATP synthesis, bacteriorhodopsin, and cytochrome oxidase function. The fundamental mechanism, however, is poorly understood. To test the theoretical possibility that bundles of hydrophobic alpha-helices could provide a low energy pathway for ion translocation through the lipid bilayer, polyamino acids were incorporated into extruded liposomes and planar lipid membranes, and proton translocation was measured. Liposomes with incorporated long-chain poly-L-alanine or poly-L-leucine were found to have proton permeability coefficients 5 to 7 times greater than control liposomes, whereas short-chain polyamino acids had relatively little effect. Potassium permeability was not increased markedly by any of the polyamino acids tested. Analytical thin layer chromatography measurements of lipid content and a fluorescamine assay for amino acids showed that there were approximately 135 polyleucine or 65 polyalanine molecules associated with each liposome. Fourier transform infrared spectroscopy indicated that a major fraction of the long-chain hydrophobic peptides existed in an alpha-helical conformation. Single-channel recording in both 0.1 N HCl and 0.1 M KCl was also used to determine whether proton-conducting channels formed in planar lipid membranes (phosphatidylcholine/phosphatidylethanolamine, 1:1). Poly-L-leucine and poly-L-alanine in HCl caused a 10- to 30-fold increase in frequency of conductive events compared to that seen in KCl or by the other polyamino acids in either solution. This finding correlates well with the liposome observations in which these two polyamino acids caused the largest increase in membrane proton permeability but had little effect on potassium permeability. Poly-L-leucine was considerably more conductive than poly-L-alanine due primarily to larger event amplitudes and, to a lesser extent, a higher event frequency. Poly-L-leucine caused two populations of conductive events, one in the 0.1-0.5 pA range, and one in the 1.0-5.0 pA range, whereas nearly all events caused by poly-L-alanine were in the 0.1-0.5 pA range at an applied voltage of +60 mV. The channel-like activity appeared to switch between conductive and nonconductive states, with most open-times in the range of 50-200 ms. We conclude that hydrophobic polyamino acids produce proton-conducting defects in lipid bilayers that may be used to model functional proton channels in biological membranes.

NASA Discipline Exobiology↗

Rotational spectroscopy at the Jet Propulsion Laboratory

Environmental monitoring, atmospheric remote sensing and astrophysical studies promoted by NASA require a strong basis of spectroscopic information. The rotational spectroscopy capabilities at NASAs Jet Propulsion Laboratory (JPL) are currently maintained for the measurement of key mission priorities that enable modeling and retrieval of geophysical data from the atmosphere as well as validation of the space-borne instruments in the Earth Observing System, particularly the Microwave Limb Sounder. Rotational spectra are measured using a variety of spectroscopic techniques including pulsed-beam Fourier transform microwave spectroscopy (at CalTech); millimeter wavelength Stark spectroscopy; millimeter, submillimeter and THz FM spectroscopy; laser sideband spectroscopy and Fourier Transform far-infrared spectroscopy. Remote measurements of atmospheric rotational spectra are made using two limb-sounder instruments in the submillimeter and THz. Recent advances in the direct synthesis of THz radiation that enable more efficient laboratory science will be presented. Software for comprehensive and systematic study of different molecular systems is maintained at JPL, the software is freely available via http://spec.jpl.nasa.gov and is used by our group to create and sustain the JPL spectral line catalog also available online.

molecular spectroscopy↗

WISEA J041451.67-585456.7 and WISEA J181006.18-101000.5: The First Extreme T-type Subdwarfs?

We present the discoveries of WISEA J041451.67−585456.7 and WISEA J181006.18−101000.5, two low-temperature (1200–1400 K), high proper motion T-type subdwarfs. Both objects were discovered via their high proper motion (>0farcs5 yr(exp -1)); WISEA J181006.18−101000.5 as part of the NEOWISE proper motion survey and WISEA J041451.67−585456.7 as part of the citizen science project Backyard Worlds; Planet 9. We have confirmed both as brown dwarfs with follow-up near-infrared spectroscopy. Their spectra and near-infrared colors are unique among known brown dwarfs, with some colors consistent with L-type brown dwarfs and other colors resembling those of the latest-type T dwarfs. While no forward model consistently reproduces the features seen in their near-infrared spectra, the closest matches suggest very low metallicities ([Fe/H] ≼ −1), making these objects likely the first examples of extreme subdwarfs of the T spectral class (esdT). WISEA J041451.67−585456.7 and WISEA J181006.18−101000.5 are found to be part of a small population of objects that occupy the “substellar transition zone,” and have the lowest masses and effective temperatures of all objects in this group.

T subdwarfs↗

Formation of a Ti–Cu(111) single atom alloy: Structure and CO binding

A single atom Ti–Cu(111) surface alloy can be generated by depositing small amounts of Ti onto Cu(111) at slightly elevated surface temperatures (~500 to 600 K). Here, scanning tunneling microscopy shows that small Ti-rich islands covered by a Cu single layer form preferentially on ascending step edges of Cu(111) during Ti deposition below about 400 K but that a Ti–Cu(111) alloy replaces these small islands during deposition between 500 and 600 K, producing an alloy in the brims of the steps. Larger partially Cu-covered Ti-containing islands also form on the Cu(111) terraces at temperatures between 300 and 700 K. After surface exposure to CO at low temperatures, reflection absorption infrared spectroscopy (RAIRS) reveals distinct C–O stretch bands at 2102 and 2050 cm –1 attributed to CO adsorbed on Cu-covered Ti-containing domains vs sites in the Ti–Cu(111) surface alloy. Calculations using density functional theory (DFT) suggest that the lower frequency C–O stretch band originates specifically from CO adsorbed on isolated Ti atoms in the Ti–Cu(111) surface alloy and predicts a higher C–O stretch frequency for CO adsorbed on Cu above subsurface Ti ensembles. DFT further predicts that CO preferentially adsorbs in flat-lying configurations on contiguous Ti surface structures with more than one Ti atom and thus that CO adsorbed on such structures should not be observed with RAIRS. The ability to generate a single atom Ti–Cu(111) alloy will provide future opportunities to investigate the surface chemistry promoted by a representative early transition metal dopant on a Cu(111) host surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental and computational investigation of the structure and spectroscopic signatures of α -UO 3

α-UO 3 is a common intermediate compound found in the nuclear fuel cycle, yet the exact crystal structure of this material has long been debated. Inconsistent computational and experimental data in previous works has led to varying conclusions between authors. Furthermore, to ensure the validity of our results in this work, the structural and spectroscopic signatures of pure phase α-UO 3 are investigated using powder X-ray diffraction and optical vibrational spectroscopy (infrared and Raman). Rietveld refinement of powder X-ray diffraction data on pure phase α-UO 3 collected in this work allows us to propose an alteration to the currently accepted C2mm structure (a = 3.9705 Å, b = 6.8553 Å, c = 4.15955 Å, α = β = γ = 90°) for α-UO 3 with no uranyl [UO 2 2+ ] bonds. Raman spectra collected using two excitation wavelengths (two instruments using 532 nm and one 785 nm) are presented, and differences with recently published results are discussed. Infrared spectra from two instruments used here agree well with recently published results, but the spectral range encompassed in our data extends past what has been reported with modern techniques. Additionally, we provide tentative vibrational mode assignments based on density functional perturbation theory calculations and resulting phonon eigenvector visualizations. Unexpected features in the optical vibrational spectra of α-UO 3 are explained by unique features in the structure we present.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Infrared nanospectroscopy characterization of metal oxide photoresists

Implementation of extreme ultraviolet (EUV) lithography in high-volume semiconductor manufacturing requires a reliable and scalable EUV resist platform. A mechanistic understanding of the pros and cons of different EUV resist materials is critically important. However, most material characterization methods with nanometer resolution use an x-ray photon or electron beam as the probe, which often cause damage to the photoresist film during measurement. Here, we illustrated the use of non-destructive infrared nanospectroscopy [or nano-Fourier-Transform infrared spectroscopy (nano-FTIR)] to obtain spatially resolved composition information in patterned photoresist films. Further, clear evidence of exposure-induced chemical modification was observed at a spatial resolution down to 40 nm, well below the diffraction limit of infrared light. With improvements, such a nano-FTIR technique with nanoscale spatial resolution, chemical sensitivity, and minimal radiation damage can be a promising candidate for the fundamental study of material properties relevant to EUV lithography.

36 MATERIALS SCIENCE↗

Probing Complex Chemical Processes at the Molecular Level with Vibrational Spectroscopy and X-ray Tools

Understanding the origins of structure and bonding at the molecular level in complex chemical systems spanning magnitudes in length and time is of paramount interest in physical chemistry. Here, we have coupled vibrational spectroscopy and X-ray based techniques with a series of microreactors and aerosol beams to tease out intricate and sometimes subtle interactions, such as hydrogen bonding, proton transfer, and noncovalent interactions. This allows for unraveling the self-assembly of arginine-oleic acid complexes in an aqueous solution and growth processes in a metal–organic framework. Terahertz and infrared spectroscopy provide an intimate view of the hydrogen-bond network and associated phase changes with temperature in neopentyl glycol. The hydrogen-bond network in aqueous glycerol aerosols and levels of protonation of nicotine in aqueous aerosols are visualized. Future directions in probing the hydrogen-bond networks in deep eutectic solvents and organic frameworks are described, and we suggest how X-ray scattering coupled to X-ray spectroscopy can offer insight into the reactivity of organic aerosols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the methanol synthesis mechanism via CO 2 hydrogenation over Cu-ZnO-ZrO2 catalysts: Effects of surfactant/Cu-Zn-Zr molar ratio

In this study, we evaluated aspects of the CO 2 hydrogenation mechanism, correlating structure-activity relationships of Cu-ZnO-ZrO 2 catalysts prepared by one-pot surfactant-assisted co-precipitation with different surfactant ratios. Identifying the CO 2 hydrogenation pathway intermediates is key to controlling the reaction selectivity. Experimental evidence shows that the CO 2 is dissociating into CO* and O* onto the surface of the Cu-ZnO-ZrO 2 catalyst. The adsorption and dissociation of CO2 were evidenced by a combination of in situ ambient-pressure X-ray Photoelectron Spectroscopy (AP-XPS) and Fourier Transform Infrared Spectroscopy (FTIR) with a transmission cell. AP-XPS showed that the catalysts are composed of a Cu 2+ , Zr 3+ , and Zr 4+ mixture and two kinds of Zn 2+ species. After the H 2 reduction process, only Cu 2+ was reduced to Cu0. The Zn and Zr species were oxidized by the dissociated O* species. In situ transmission FTIR showed that CO was adsorbed onto the Cu+/0 sites. The catalyst with the higher surfactant molar ratio exhibited the highest CO 2 conversion close to the equilibrium conversion, as well as a good methanol formation rate.

36 MATERIALS SCIENCE↗

Effect of Water Concentration in LiPF 6 -Based Electrolytes on the Formation, Evolution, and Properties of the Solid Electrolyte Interphase on Si Anodes

A trace amount of water in an electrolyte is one of the factors detrimental to the electrochemical performance of silicon (Si)-based lithium-ion batteries that adversely affect the formation and evolution of the solid electrolyte interphase (SEI) on Si-based anodes and change its properties. Thus far, a lack of fundamental and mechanistic understanding of SEI formation, evolution, and properties in the presence of water has inhibited efforts to stabilize the SEI for improved electrochemical performance. As such, we investigated the SEI formed in a Gen2 electrolyte (1.2 M LiPF6 in ethylene carbonate/ethyl methyl carbonate, 3:7 wt %, water content: <10 ppm) with and without additional water (50 ppm) at varying potentials (1.0, 0.5, 0.2, and 0.01 V vs Li/Li + ). The impact of additional water on the morphological, (electro)chemical, and structural properties of SEI was studied using microscopic (atomic force microscopy and scanning spreading resistance microscopy) and spectroscopic (X-ray photoelectron spectroscopy, attenuated total reflection Fourier-transform infrared spectroscopy, and time-of-flight secondary ion mass spectrometry) techniques. The SEI exhibits both potential- and water concentration-dependent trends in its morphology and chemical composition. The presence of additional water in the electrolyte causes parasitic reactions, which onset at ~1.0 V, resulting in a reduction of electrolyte components and result in the formation of an insulating, fluorophosphate-rich SEI. In addition, hydrolysis of LiPF 6 creates hydrofluoric acid, which reacts with the surface oxide layer on the Si electrode, leading to a pitted and inhomogeneous SEI structure.

36 MATERIALS SCIENCE↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Organo-Nanocups Assist the Formation of Ultra-Small Palladium Nanoparticle Catalysts for Hydrogen Evolution Reaction

Ultra-small palladium nanoparticles were synthesized and applied as catalysts for a hydrogen evolution reaction. The palladium metal precursor was produced via beta-cyclodextrin as organo-nanocup (ONC) capping agent to produce ultra-small nanoparticles used in this study. The produced ~3 nm nanoparticle catalyst was then characterized via X-ray diffraction (XRD), transmission electron microscopy (TEM), ultraviolet-visible spectroscopy (UV-Vis), and Fourier transform infrared spectroscopy (FTIR) to confirm the successful synthesis of ~3 nm palladium nanoparticles. The nanoparticles’ catalytic ability was explored via the hydrolysis reaction of sodium borohydride. The palladium nanoparticle catalyst performed best at 303 K at a pH of 7 with 925 μmol of sodium borohydride having an H 2 generation rate of 1.431 mL min -1 mL cat -1 . The activation energy of the palladium catalyst was calculated to be 58.9 kJ/mol.

36 MATERIALS SCIENCE↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗