Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Voltage Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A Simple Halogen-Free Magnesium Electrolyte for Reversible Magnesium Deposition through Cosolvent Assistance

Rechargeable Mg batteries are one of the most investigated polyvalent-metal storage batteries owing to the increased safety associated with the nondendritic nature of Mg electrodeposition, high volumetric capacity, and low cost. To realize the commercial applications of Mg batteries, there are still a number of challenges remaining unsolved, in particular, the lack of halogen free Mg electrolytes, as the use of the halogens remains a major limiting factor to achieving high voltage cathodes. The research presented here introduces an innovative approach to prepare a halogen-free Mg-based electrolyte in a simple, nonsynthetic method that can plate and strip Mg reversibly. Results suggest that by introducing a secondary amine cosolvent the magnesium bis(trifluoromethanesulfonyl)imide (Mg(TFSI) 2 ) salt can be easily dissolved into a wide array of polar but aprotic ether solvents. A systematic structural investigation of a representative Mg(TFSI) 2 electrolyte in the cosolvent systems with the secondary amine was performed using pair distribution function (PDF) analysis, single crystal diffraction analysis, and NMR. The experimental atomic scale understanding reveals an ion pair structure of Mg 2+ coordinated with six oxygen donors from the bis(trifluoromethanesulfonyl)imide (TFSI) anions and the THF solvent located in the first solvation shell. The as-formed neutral ion pair structure acts as the active component for reversible Mg deposition. We believe this new route of preparing Mg electrolytes can extend the current understanding of Mg electrolyte functionality for rechargeable Mg batteries and offers more guidance for the future electrolyte design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study on the impact of mid-gap defects on vertical GaN diodes

GaN is a favorable martial for future efficient high voltage power switches. GaN has not dominated the power electronics market due to immature substrate, homoepitaxial growth, and immature processing technology. Understanding the impact of the substrate and homoepitaxial growth on the device performance is crucial for boosting the performance of GaN. Here, we studied vertical GaN PiN diodes that were fabricated on non-homogenous Hydride Vapor Phase Epitaxy (HVPE) substrates from two different vendors. We show that defects which stemmed from growth techniques manifest themselves as leakage hubs. Different non-homogenous substrates showed different distribution of those defects spatially with the lesser quality substrates clustering those defects in clusters that causes pre-mature breakdown. Energetically these defects are mostly mid-gap around 1.8Ev with light emission spans from 450nm to 700nm. Photon emission spectrometry and hyperspectral electroluminescence were used to locate these defects spatially and energetically.

42 ENGINEERING↗

Redox flow cell energy storage systems

The redox flow cell energy storage system being developed by NASA for use in remote power systems and distributed storage installations for electric utilities is presented. The system under consideration is an electrochemical storage device which utilizes the oxidation and reduction of two fully soluble redox couples (acidified chloride solutions of chromium and iron) as active electrode materials separated by a highly selective ion exchange membrane. The reactants are contained in large storage tanks and pumped through a stack of redox flow cells where the electrochemical reactions take place at porous carbon felt electrodes. Redox equipment has allowed the incorporation of state of charge readout, stack voltage control and system capacity maintenance (rebalance) devices to regulate cells in a stack jointly. A 200 W, 12 V system with a capacity of about 400 Wh has been constructed, and a 2 kW, 10kWh system is planned.

Thaller, L. H.↗

Long-term reliability of hand-soldering M55365 Ta capacitors

This is a continuation of the report “Effects of Hand Soldering MIL-PRF-55365 Tantalum Capacitors,” which discusses the parametric effects of convection reflow soldering, JPL standard hand soldering, and optimized hand soldering on solid tantalum capacitors. The current focus is determining the long-term reliability effects of the various soldering techniques. Unfortunately, the 100-piece sample size chosen for the highly accelerated life tests was too small to reliably determine the effects of the different soldering techniques on the lifespan of the parts. In hindsight, this likely could have been predicted based on the large alphas and small betas of the Weibull failure distributions discovered during the scouting trials. Now that the effects of inadequate sample size are better understood, an opportunity exists to not only discover whether there are real differences in the reliability associated with the various soldering techniques, but also the potential to discover the voltage acceleration model and the temperature acceleration effect for these capacitors. It is recommended that the testing be repeated with a more appropriate sample size to capture this useful information.

Spence, Penelope↗

Uncovering the Solvation Structure of LiPF 6 –Based Localized Saturated Electrolytes and Their Effect on LiNiO 2 –Based Lithium–Metal Batteries

Electrolytes play a critical role in stabilizing highly reactive lithium-metal anodes (LMAs) and high-voltage cathodes for rechargeable lithium-metal batteries (LMBs). Localized high concentration electrolytes (LHCEs) have achieved remarkable success in the context of LMBs. However, the state-of-the-art LHCEs are based on LiFSI salt, which is prohibitively expensive. Here, the utility of low-cost LiPF 6 salt in localized saturated electrolytes (LSEs) with a series of solvents and diluents in LMBs with cobalt-free LiNiO 2 cathode is systematically explored. Experimental and theoretical analyses reveal that the unique solvation structure formed not only changes the distribution of solvents and anions but also alters the atom–atom distances within them, leading to different reduction and oxidation stabilities compared to low-concentration electrolytes. In addition, LSEs help form LiF-rich interphase layers on the LMA and LiNiO 2 cathode, protecting the electrodes from degradation during cycling. Different LSEs also lead to differences in lithium plating morphology and impedance buildup during cycling, impacting the performance of LMBs. Finally, the solvent and diluent must be carefully selected for compatibility with a lithium salt when developing LHCEs and LSEs for LMBs.

25 ENERGY STORAGE↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Electric Vehicle Charging Management in Smart Energy Communities to Increase Renewable Energy Hosting Capacity

Abnormal climates due to global warming have emerged as a big concern in the global community. To mitigate climate change and achieve sustainability, distributed energy resources (DERs), including solar and wind, have been recently deployed in power systems. As the penetration level of DERs has increased, however, it caused a multitude of issues in the power systems, such as voltage fluctuation in the distribution network limiting renewable hosting capacity. On the other hand, the electric vehicle (EV) industry is rapidly growing to facilitate the transition to a carbon-neutral community, illuminating the potential of EVs as a flexible grid asset to mitigate some of the issues and improve grid operation, if properly exploited. To explore the potential of EVs, this paper proposes an EV scheduling strategy. By using an optimal EV charging scheduling proposed, distribution system operators (DSOs) can minimize their operating costs and stably operate the system with a high level of DERs. To validate the method, a modified IEEE 33-bus system with DERs is developed. The case study shows the proposed scheduling strategizes EV charging to reduce the cost of PV curtailment. In the study, the method outperforms the renewable-only case with curtailment by 4.97% in DSO cost. It also demonstrates its potential to increase the renewable hosting capacity by harmonizing EV charging with renewables.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Dot junction solar cells

A design of solar cells with reduced junction area on the cell surface is investigated for reduction of saturation current and increase in open-circuit voltage. Equidiameter dot junctions distributed across the surface of the cell offer an efficient alternative, with variations in dot diameter and in the spacing between dots giving the required variations in the ratio of junction area to total surface area. A simplified analysis for short-circuit current and other cell parameters, which enables cell design optimization, is presented. Experimental solar-cell performance results, as functions of different area ratios, are presented and compared with the model. It is shown that saturation current reduction is possible for achieving efficiencies as high as 18 percent in flat-plate terrestrial applications.

Daud, T.↗

Operational Characteristics of a Low-Energy FARAD Thruster

Data from a 100 J per pulse electrodeless accelerator employing pulsed RF-preionization are presented to gain insight into the accelerator's operating characteristics. The data suggest that the propellant distribution is highly unoptimized, with most of the gas inaccessible to the discharge and the remainder mostly concentrated at the inner radius of the coil. The pulsed RF-preionization discharge produces a visible plasma, but like the gas distribution it mostly appears concentrated at the inner radius of the thruster. Magnetic field probes in the discharge point to a current sheet that is not magnetically impermeable. These data also exhibit signs of nonrepeatability, and time-integrated discharge photography shows signs of spatial nonuniformity in both the radial and azimuthal directions. Terminal voltage measurements on the two capacitor banks of the thruster do not exhibit the asymmetric nature (in time) typically associated with an efficient pulsed plasma accelerator. Based on the experimental evidence, the poor performance of the thruster is thought to be due to insufficient preionization, which at these low discharge energy levels severely limits the ability of the main current pulse to couple with and effectively accelerate the propellant.

Polzin, Kurt A.↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

Townsend to glow discharge transition for a nanosecond pulse plasma in helium: space charge formation and resulting electric field dynamics

Stark polarization spectroscopy is used to investigate the temporal evolution of the electric field distribution in the cathode region of a nanosecond pulsed discharge in helium at 120 Torr. The measurements are performed on the He I transition at 492.19 nm, during the early stages of the discharge formation. The experimental results are compared with the predictions of a 1D fluid model. Time-resolved ICCD images show that the discharge develops as a diffuse, cathode-directed ionization wave with a Townsend-like feature before transitioning into a glow-like structure. Near anode instabilities characterized by filament formation were observed near the high voltage electrode. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. Additionally, the cathode electric field corresponding to this sheath with a thickness of 250 μm is about 40 kV cm -1 . A subsequent steep increase of the discharge current leads to a further reduction of the sheath width. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory-Model Integrated-System FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster [1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In a previous paper [3], the authors presented a basic design for a 100 J/pulse FARAD laboratory-version thruster. The design was based upon guidelines and performance scaling parameters presented in Refs. [4, 5]. In this paper, we expand upon the design presented in Ref. [3] by presenting a fully-assembled and operational FARAD laboratory-model thruster and addressing system and subsystem-integration issues (concerning mass injection, preionization, and acceleration) that arose during assembly. Experimental data quantifying the operation of this thruster, including detailed internal plasma measurements, are presented by the authors in a companion paper [6]. The thruster operates by first injecting neutral gas over the face of a flat, inductive acceleration coil and at some later time preionizing the gas. Once the gas is preionized current is passed through the acceleration coil, inducing a plasma current sheet in the propellant that is accelerated away from the coil through electromagnetic interaction with the time-varying magnetic field. Neutral gas is injected over the face of the acceleration coil through a fast-acting valve that feeds a central distribution manifold. The thruster is designed to preionize the gas using an RF-frequency ringing signal produced by a discharging Vector Inversion Generator (VIG). The acceleration stage consists of a multiple-turn, multiple-strand spiral induction coil (see Fig. 1, left panel) and is designed for operation at discharge energies on the order of 100 J/pulse. Several different pulsed power train modules can be used to drive current through the acceleration coil. One such power train is based upon the Bernardes and Merryman circuit topology, which restricts voltage reversal on the capacitor banks and can be clamped to eliminate current reversal in the coil. A second option is a pulse-compression-ring power train (see Fig. 1, right panel), which takesa temporally broad, low current pulse and transforms it into a short, high current pulse.

Polzin, K.A.↗

HERMES 2019 Upgrade Characterization - Quick Look Report (UUR)

Characterizing the electromagnetic environment created by the recently upgraded HERMES III pulser is the primary objective addressed by this report. The pulser upgrade design was intended not only to provide higher electric field and magnetic field illumination amplitudes but also to provide a more collimated beam, focused along the center-line of the courtyard. For high-voltage pulsers to be useful as qualification systems, they must have the requisite peak values and uniform, predictable peak field spatial patterns. To assess the peak electric field values and uniformity of the spatial pattern of the electric fields for the upgraded HERMES system, a 1 6 full-power shot illumination of 9 electric and 9 magnetic field sensors in the courtyard of the HERMES III facility was conducted. The data acquired from this test showed an increase an increase in electric field amplitude, but still an asymmetry in the spatial distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High voltage and current, gate assisted, turn-off thyristor development

An improved high speed power switch with unique turn-off capability was developed. This gate assisted turn-off thyristor (GATT) was rated 1000 volts and 100 amperes with turn-off times of 2 microseconds. Fifty units were delivered for evaluation. In addition, test circuits designed to relate to the series inverter application were built and demonstrated. In the course of this work it was determined that the basic device design is adequate to meet the static characteristics and dynamic turn-off specification. It was further determined that the turn-on specification is critically dependent on the gate drive circuit due to the distributive nature of the cathode-gate geometry. Future work should emphasize design modifications which reduce the gate current required for fast turn-on, thereby opening the way to higher power (current) devices.

Nowalk, T. P.↗

Stabilizing high-Ni cathodes with gradient surface Ti-enrichment

High-Ni cathodes are being intensely pursued worldwide for electric vehicles and other energy-dense applications due to their high capacity and low cost. However, structural instabilities during electrochemical cycling and when subjected to thermal treatment have been the major issues hindering their practical deployment. We here report a rational design of coating-integrated-into-synthesis protocol for fabricating surface Ti-enriched LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811#Ti) material. The coating to intermediates is crucial to obtain high structural ordering, both in the bulk and surface of high-Ni cathodes, and the Ti substitute has a unique tri-valence (Ti 3+ ) in a gradient surface distribution. Further, the simulations of projected density of states in the atomistic understanding further certify significantly enhanced stability of lattice oxygen for the NMC811 through such a Ti 3+ -based structure reinforcement. Consequently, the NMC811#Ti cathode delivers a high capacity up to 200mAhg -1 at 0.1 C, along with superior stabilities during air-storage and thermal treatment (up to 297°C at the fully charged state under differential scanning calorimetric measurements). The corresponding NMC811#Ti||graphite full cell exhibits a desired 83.6% capacity retention after 1000 cycles at 0.5 C in a voltage range of 2.8–4.3V. This work demonstrates a delicate surface reinforcement to stabilize high-Ni cathodes for long-life and safe lithium-ion batteries.

36 MATERIALS SCIENCE↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗