Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Interaction of radio frequency waves with cylindrical density filaments -- scattering and radiation pressure

The propagation of radio-frequency (RF) waves in tokamaks can be affected by filamentary structures, or blobs, that are present in the edge plasma and the scrape-off layer. The difference in the permittivity between the surrounding plasma and interior of a filament leads to reflection, refraction and diffraction of the waves. This, in turn, can affect the power flow into the core of the plasma and reduce the efficiency of heating and/or current generation. The scattering of RF waves, lower hybrid, helicon and ion cyclotron waves, by a single cylindrical filament, embedded in a background plasma, is studied using a full-wave analytical theory developed previously (Ram & Hizanidis, Phys. Plasmas, vol. 23, 2016, 022504). The theory assumes that the plasma in and around a filament is homogeneous and cold. A detailed scattering analysis reveals a variety of common features that exist among the three distinctly different RF waves. These common attributes can be inferred intuitively based on an examination of the cold plasma dispersion relation. The physical intuition is a useful step to understanding experimental observations on scattering, as well as results from simulations that include general forms of edge plasma turbulence. While a filament can affect the propagation of RF waves, the radiation force exerted by the waves can influence the filament. The force on a filament is determined using the Maxwell stress tensor. In 1905, Poynting was the first to evaluate and measure the radiation force on an interface separating two different dielectric media (Poynting, London Edinburgh Dublin Philos. Mag. J. Sci., vol. 9, 1905, pp. 393–406). For ordinary light propagating in vacuum and incident on a glass surface, Poynting noted that the surface is ‘pulled’ towards the vacuum. In a magnetized cold plasma, there are two independent wave modes. Even if only one of these modes is excited by an RF antenna, a filament will couple power to the other mode: a consequence of electromagnetic boundary conditions. This facet of scattering has consequences on the radiation force that go beyond Poynting's seminal contribution. The direction of the force depends on the polarization of the incident wave and on the mode structure of the waves inside and in the vicinity of a filament. It can either pull the filament toward the RF source or push it away. For slow lower hybrid waves, filaments with densities greater than the ambient density are pulled in, while filaments with lower densities are pushed out, thereby enhancing the density in front of the antenna. In the case of fast helicon and ion cyclotron waves, the direction of the force depends on the plasma and wave parameters; in particular, on the ambient density. The radiation force, in all three frequency ranges, is large enough to affect the motion of a filament and could be measured experimentally. This also suggests the possibility of modifying the edge turbulence using RF waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accessibility and Availability of Gas Stations for Liquid Fuel Supply During Severe Weather Events

Energy infrastructure is a pivotal lifeline with wider inter-dependencies. Electric power is essential to the continued functioning of critical assets; liquid fuels and other physical primary energy commodities that are used to supply the local energy needs of these assets during extreme events when electricity infrastructure is compromised. During Superstorm Sandy, the disruption of fuel supplies in the Tri-state area necessitated increasing situational awareness about oil and natural gas (ONG) systems to redirect fuel supplies to first responders and for restoration efforts. During winter storm events over the past several years, the demand for ONG for heating and power generation has skyrocketed in the north-east, which subsequently had caused ONG price to hit their highest level in years. ONG is a major energy source for restoration and recovery activities. However, very little, if any, situational awareness information about ONG supply and demand is available to those coordinating emergency efforts. Often this lack of information is due to the decentralized nature of the ONG supply chain and proprietary data maintained by private entities. To understand the impact of fuel availability on response and recovery efforts, this research focuses on (i) determining the accessibility to gas stations for liquid fuel supply across space and time, and (ii) examining the spatio-temporal variation of fuel availability and demand during extreme weather events. The broader scope of the project focuses on providing spatio-temporal situational awareness information about ONG availability and demand across the fuel supply chain for positioning of resources for response activities.

Kar, Bandana↗

ZrCoBi based half Heuslers with high thermoelectric conversion efficiency

A method of thermoelectric power generation by converting heat to electricity via the use of a ZrCoBi-based thermoelectric material, wherein a thermoelectric conversion efficiency of the ZrCoBi-based thermoelectric material is greater than or equal to 7% at a temperature difference of up to 800 K.

Ren, Zhifeng↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Ultra-fast and Thick Boriding of Geothermal Casing to Enhance Reliability

Harnessing the heat that is continuously generated underneath the Earth’s crust (geothermal) is a clean and renewable source of energy. Geothermal energy can be used to heat and cool buildings, including greenhouses, and to generate electrical power. Compared to other renewable energy sources such as solar and wind, geothermal energy is more reliable because it is available all the time and versatile in its many forms of application and deployment. Nonetheless, the deployment and extensive use of geothermal energy still lags behind other renewable sources due to some technical, but mainly economic challenges. Upfront costs of geothermal power well development are relatively high. Some of this high cost is attributed to the use of expensive construction materials to ensure adequate performance during operation. For example, Inconel 625, super duplex 2507, and titanium alloy materials are used in downhole casings, piping, and other components exposed to brine solution to withstand harsh operating environments (high temperature and corrosive environments). Relatively low-cost carbon steel can be used in many of these components in geothermal power plants; however, they are susceptible to excessive corrosion, thereby limiting their useful lifespan. Ultra-fast boriding (UFB) surface treatment of carbon steel may drastically increase its corrosion resistance thereby providing a cost-effective material solution in geothermal applications. Scientists at Argonne National Laboratory (ANL) recently developed a technique to accelerate the boriding process using a high-temperature electrochemical process to produce relatively thick boride layers on various metal and alloy materials in minutes rather than the several hours it takes through the typical pack boriding process; hence, the process is designated UFB. The process uses molten borax salt at 900– 1000°C in an electrochemical cell in which the material to be borided is the cathode and a graphite plate is the anode. Continuous and durable boride layers with thicknesses of 100–300 µm have been produced on a variety of metals and alloys in one hour. Such a surface layer can indeed be a cost-effective pathway to prevent corrosion of casing materials in contact with the chemically aggressive and corrosive geothermal brine fluids.

15 GEOTHERMAL ENERGY↗

Feasibility Assessment of a Natural-Circulation Salt Irradiation Loop in the Advanced Test Reactor

Molten-salt reactors will likely require some level of irradiation testing as part of their licensing basis. An ideal experiment would consider the integrated effect of neutron flux and fission product generation in addition to circulating flow conditions. The feasibility of a natural-circulation irradiation salt loop in the Advanced Test Reactor (ATR) is assessed here. The flow is induced by the innovative combination of gas gaps and fin gaps along the capsule wall to fine-tune radial heat conductance, and therefore drive an axial temperature gradient across the experiment height. Following multiple design optimizations, a promising configuration has been identified. The 45-kW experiment would generate a 0.15 m/s flow velocity with 6 kg of fuel-bearing salt. This demonstrates the possibility of generating appreciable flow rates within manageable experimental conditions (e.g., total size and heat generation). An initial assessment of species mass tracking inside the experiment was also performed to gain an understanding of radionuclide behavior within the system. Results showed that significant quantities of Xe can be extracted in the off-gas (1.7 kCi) for an 8% bubble removal efficiency rate. Here, these results highlight the potential value of such experiments. Further work will involve detailed engineering drawings and analyses of the loop, as well as more computationally expensive modeling of species mass tracking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NSTX-U theory, modeling and analysis results

Here, the mission of the low aspect ratio spherical tokamak NSTX-U is to advance the physics basis and technical solutions required for optimizing the configuration of next-step steady-state tokamak fusion devices. NSTX-U will ultimately operate at up to 2 MA of plasma current and 1 T toroidal field on axis for 5 s, and has available up to 15 MW of neutral beam injection power at different tangency radii and 6 MW of high harmonic fast wave heating. With these capabilities NSTX-U will develop the physics understanding and control tools to ramp-up and sustain high performance fully non-inductive plasmas with large bootstrap fraction and enhanced confinement enabled via the low aspect ratio, high beta configuration. With its unique capabilities, NSTX-U research also supports ITER and other critical fusion development needs. Super-Alfvénic ions in beam-heated NSTX-U plasmas access energetic particle (EP) parameter space that is relevant for both α-heated conventional and low aspect ratio burning plasmas. NSTX-U can also generate very large target heat fluxes to test conventional and innovative plasma exhaust and plasma facing component solutions. This paper summarizes recent analysis, theory and modelling progress to advance the tokamak physics basis in the areas of macrostability and 3D fields, EP stability and fast ion transport, thermal transport and pedestal structure, boundary and plasma material interaction, RF heating, scenario optimization and real-time control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Gas Transport in the Insensitive High Explosive PBX 9502

Small-scale laboratory experiments were performed to analyze gas transport mechanics in PBX 9502, an insensitive high explosive (IHE) composition. Two independent investigations are reported here. First, gas permeametry and dynamic pycnometry techniques were used to measure the molecular flow (Knudsen) coefficient and the internally interconnected void fraction of pristine and thermally damaged samples in two uniaxial pressing orientations. The permeability of PBX 9502 was found to be unmeasurably low (of the same order of magnitude as PTFE) with gas transport being diffusion-dominated. Secondly, a pressure vessel experiment was developed to measure quasi-static and dynamic gas generation as the explosive was heated to self-ignition (cookoff). The gas generation results and the permeability/diffusivity findings provide evidence that PBX 9502 remains impermeable until seconds prior to self-ignition. At ignition, internal void-pressure drives macro-scale cracking and the sample becomes uniformly incorporated in the following deconsolidating deflagration. These results are discussed within the context of previous observations of pressure-dependent cookoff behavior of PBX 9502 and provide a more complete description of thermal damage evolution in this explosive composition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimizing flow condensation models for next-generation refrigerants in axial micro-fin aluminum tubes

To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CO 2 conversion to syngas via electrification of endothermal reactors: Process design and environmental impact analysis

CO 2 utilization via reverse water gas shift (rWGS) reaction has been proposed as a path to the sustainable utilization. Here this work presents a detailed process modelling study where steam methane reforming (SMR) generated hydrogen was combined with rWGS to produce syngas (CO + H 2 ) with various hydrogen-to-carbon oxide ratios. To further decrease CO 2 emissions that may offset the benefits of CO 2 converted in rWGS, electrification of endothermal reactors, both SMR and rWGS was considered where CO 2 emitting fuel burning in the furnace was replaced by the emerging ohmic (resistive) heating. Material and energy inventory obtained from process design calculations was used to perform Life Cycle Analysis (LCA) to calculate environmental impacts of CO 2 consumption and reactor electrification. The results showed that greenhouse gas emissions, in CO 2 kg equivalent, were the lowest when both SMR and rWGS were heated using wind-generated electricity, decreasing from 25 to 10 kg CO 2 equivalent for H 2 :CO = 2:1 while the conventional electricity mix used for furnace electrical heating across the board of scenarios generated highest environmental impacts, much higher than those that used natural gas as fuel. Process economics calculations suggested that, when both SMR and rWGS were electrically heated, the process only showed product syngas cost parity with the conventional fuel heated design when electricity cost was ~$0.008/kWh. This suggests that CO 2 utilization scenarios involving process electrification need to be carefully considered from the total design perspective so they do not produce more greenhouse gases than in conventional non-electrified scenarios.

42 ENGINEERING↗

Markets and Economic Requirements for Fission Batteries and Other Nuclear Systems

Fission Batteries (FBs) are nuclear reactors defined by five characteristics which enable large-scale deployment: cost competitive, standardized sizes for economic mass production, easy installation and removal, secure and safe unattended operation with high reliability. FBs are not defined by technology or power level. Technical and market considerations suggest that most FBs will produce 20 to 30 MWt. This proceedings reports on the outcomes of two workshops that were held in January 2021 to better define markets and economic challenges for FBs. Three major markets were identified. The largest market is the industrial and commercial heat market. There are about 4000 industrial users (excluding utilities) that require more than one megawatt of heat. The number of customers versus size of heat demand was determined. In a low-carbon world there is the potential for many additional customers—including expanded biofuels production and district heat. The second market is for non-grid electricity. This includes co-generation plants that produce heat and electricity for a single customer. The third market is the maritime market with ~100,000 ships worldwide. In the United States, natural gas is the low-cost energy option today and will remain so unless constraints or taxes impact its use. If restrictions on greenhouse gas emissions, the FB competition includes natural gas with carbon capture, biofuels, hydrogen and grid electricity. Natural gas with carbon capture is not economically viable on a small scale. Biofuels may be expensive but may be the economically preferred option for locations with small energy demands of a few megawatts. Hydrogen is a potential competitor with many of the characteristics of natural gas. Grid electricity is not a competitive source of heat. For FBs to be economically competitive, the price of delivered heat must be $20-50/MWh ($6-15/million BTU). The economically competitive range for non-grid electricity is estimated at $70-100/MWh. These electricity prices are competitive with the retail prices of electricity in many parts of the United States for the customer. FBs are not expected to be competitive selling wholesale electricity to the grid. To achieve the aforementioned cost targets for heat and electricity markets, FB designers must (1) maximize the power output within the constraints of a FB (e.g., truck transportability, passive decay heat removal), (2) drastically reduce the size of onsite staff, (3) adopt core designs with low fuel costs (enrichment and fabrication), and (4) develop a system design that is efficiently manufactured in factories. The business case depends upon more than being just a replacement for natural gas. The largest incentives for adoption of FBs is where they create new markets and new sources of revenue. An example is the paper and pulp industry that burns biomass wastes to provide heat and electricity to make paper. An external heat source could meet the demand for heat and electricity by the paper process and enable converting waste biomass into liquid biofuels rather than burning to provide heat. Other markets, such as data centers, are driven by special energy requirements such as extreme reliability. Most customers are not in the energy business but need heat and electricity to produce a product—a manufactured good, education, retail sales (shopping malls), marine transport or some other product. As a consequence, there will be large incentives to lease rather than own FBs. Leasing avoids the regulatory challenges that remain with the owner of the FB. Leasing creates large incentives for FP standardization of sizes and transportability to maintain the value of the FB at the end of the lease—similar to the leasing of jet engines and aircraft. The economic constraints combined with technical constraints suggest competitive FBs will likely have outputs exceeding 10 MWt. There appear to be little incentives for very long-lived reactor cores because such machines require much larger inventories of fuel. Maintenance requirements and the options to provide technology updates may favor shorter lifetimes (~5 years). The assessment is that there is the potential for FBs to be economically viable and play a major role in global decarbonization in three markets: heat, non-grid electricity and maritime applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The evolving role of geothermal energy for decarbonizing the United States

Geothermal energy is often referred to as a niche technology that is too localized, too small or too expensive to make much of a difference in how renewable energy will be supplied in a fully decarbonized future. As a result, geothermal energy has been undervalued in terms of what it could provide to complement, rather than compete with, electricity generation from wind, solar photovoltaic, concentrating solar power and other renewables. Geothermal energy systems are fully dispatchable and can provide baseload or load-following electric power or heat suitable for a wide range of applications including supplying district heating for communities and cities, and heating and cooling of individual buildings. The focus of our study is on the potential of utilizing geothermal energy for providing heat for buildings and industry at lower temperatures, a substitute for the combustion of fossil fuels. Because heating represents about 20% (20 EJ per year) of the annual primary energy consumption in the U.S.—with most of it coming from burning natural gas, oil and/or propane in furnaces—deploying geothermal heating on a national scale could have a significant impact on lowering carbon emissions. In heating-dominated states in the U.S. Northern Tier, heating often is among the largest contributors to the state's carbon footprint. This review begins with a discussion of the motivation and rationale behind considering geothermal as a key low-carbon heating option for the U.S. The study summarizes the U.S. geothermal resource and describes the applications and main engineering components of using geothermal energy for heating and cooling, electric power generation, and co-generation using district heating, geothermal heat pumps, and power conversion with steam flashing and organic Rankine plants. Environmental benefits and impacts are described. An extensive discussion of geologic and thermal-hydraulic aspects of the subsurface is included in the review because of their critical role in determining reservoir designs at specific sites to ensure sufficient productivity that is both safe and economically viable. Models for estimating levelized costs of district heating are used to show how costs are affected by reservoir performance, infrastructure capital costs, and financial parameters. Here, the review concludes with an assessment of technical subsurface issues associated with reservoir performance and the economic requirements for providing geothermal heating in district heating systems at a sufficient scale to have an impact on decarbonizing the U.S.

15 GEOTHERMAL ENERGY↗

Field-emission plasma enhancement of H₂–O₂ micro-combustion

In this paper, a detailed three-dimensional computational model is developed to assess the potential of micron-scale field emission dielectric barrier discharge (FE-DBD) plasma actuators in non-premixed microburners with channel heights in the range of L z = 0.25–0.75 mm. Results for H 2 –O 2 combustion with Reynolds number Re = 100 are studied for different configurations of plasma actuator arrays. Without plasma actuation, results agree with corresponding experiments, although in this case the burner typically suffers from incomplete combustion due to thermal quenching, radical quenching, and slow diffusive mixing. For the range of conditions simulated, plasma actuation increases combustion completeness from 25%–70% to 40%–80% by enhancing mixing, generating radicals, and Joule heating. Ionic wind resulting from the FE-DBD plasma disrupts the otherwise simple laminar flow in the burner, accelerating the growth of a mixing layer and enhancing heat transfer to channel walls. The larger, lower temperature flames reduce thermal gradients (and thereby thermal stresses) in the walls. Radical generation due to electron-impact dissociation extends the reaction zone in the diffusion flame and increases combustion completeness. In all cases, the additional heat release with plasma actuation (100–190 W) is significantly larger than the power needed to sustain the plasma (≲0.1 W), suggesting that plasma actuation may provide a significant advantage in energy generation using realistic portable micro-combustion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗