Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Modelling the performance of the monogroove with screen heat pipe for use in the radiator of the solar dynamic power system of the NASA Space Station

A computer code to model the steady-state performance of a monogroove heat pipe for the NASA Space Station is presented, including the effects on heat pipe performance of a screen in the evaporator section which deals with transient surges in the heat input. Errors in a previous code have been corrected, and the new code adds additional loss terms in order to model several different working fluids. Good agreement with existing performance curves is obtained. From a preliminary evaluation of several of the radiator design parameters it is found that an optimum fin width could be achieved but that structural considerations limit the thickness of the fin to a value above optimum.

Evans, Austin Lewis↗

Computer modeling of heat pipe performance

A parametric study of the defining equations which govern the steady state operational characteristics of the Grumman monogroove dual passage heat pipe is presented. These defining equations are combined to develop a mathematical model which describes and predicts the operational and performance capabilities of a specific heat pipe given the necessary physical characteristics and working fluid. Included is a brief review of the current literature, a discussion of the governing equations, and a description of both the mathematical and computer model. Final results of preliminary test runs of the model are presented and compared with experimental tests on actual prototypes.

Peterson, G. P.↗

Performance investigations of liquid-metal heat pipes for space and terrestrial applications

The high heat transfer capacity of liquid-metal heat pipes is demonstrated in performance tests with mercury, potassium, sodium, and lithium working fluids and wick structures which serve to minimize liquid pressure losses and vapor/liquid interactions. Appropriate wicks for horizontal and vertical operation are described. It is shown that heat-transfer with these wicks is limited by vapor flow effects. Examples are given of particular effects associated with a long adiabatic section between evaporator and condenser and with a heat source of uniform temperature as opposed to a source of uniform power.

Kemme, J. E.↗

Heat-Pipe Thermal Switch

New design isolates components from vibrations. Heat-pipe thermal switch controls temperature of heat source. Ball-and-socket guide rods and bellows allow relative motion of source and its heat sink and protect source from vibrations. Designed for cooling vibration-sensitive electronic components.

Ollendorf, S.↗

Cryogenic Heat Pipe Experiment (CRYOHP)

The objective of the CRYOHP experiment is to conduct a shuttle experiment that demonstrates the reliable operation of two oxygen heat pipes in microgravity. The experiment will perform the following tasks: (1) demonstrate startup of the pipes from the supercritical state; (2) measure the heat transport capacity of the pipes; (3) measure evaporator and condenser film coefficients; and (4) work shuttle safety issues. The approach for the experiment is as follows: (1) fly two axially grooved oxygen heat pipes attached to mechanical stirling cycle tactical coolers; (2) integrate experiment in hitch-hiker canister; and (3) fly on shuttle and control from ground.

Mcintosh, Roy↗

An approximate analysis of the diffusing flow in a self-controlled heat pipe.

Constant-density two-dimensional axisymmetric equations are presented for the diffusing flow of a class of self-controlled heat pipes. The analysis is restricted to the vapor space. Condensation of the vapor is related to its mass fraction at the wall by the gas kinetic formula. The Karman-Pohlhausen integral method is applied to obtain approximate solutions. Solutions are presented for a water heat pipe with neon control gas.

Somogyi, D.↗

Startup of a frozen heat pipe in one-g and micro-g environments - A proposed shuttle flight experiment

An attempt is made to determine how a heat pipe freezes under various low load and/or no load conditions in both one-g and micro-g environments. Also of interest are the mechanisms that can be used to restart the heat pipe after freezing has occurred. Particular attention is given to step function power reductions and the resulting distribution of the working fluid after freezing has occurred and the effect of noncondensible gases on the frozen configuration and the restart characteristics.

Ochterbeck, J. M.↗

Swift BAT Loop Heat Pipe #0 Temperature Droop Problem and Solution After Its Primary Heater Controller Failure

The primary heater controller for Burst Alert Telescope (BAT) loop heat pipe (LHP) #0 failed on March 31, 2010. It has been disabled. The secondary heater circuit is operational. However the set point tolerance of the secondary heater controller is significantly out of specifications. A novel variable conductance heat pipe (VCHP) is used to pre-condition the LHP propylene liquid before it returns to the compensation chamber (CC). Due to the limit on the quantity of power switches, the LHP and VCHP temperatures are controlled by different channels of the same heater controller. For this reason, the VCHP heater controller channel is also out of specification. It caused larger tolerances in the temperature of the propylene liquid returning to the CC. As a result, there were intermittent temperature droops every 10-14 days at the coldest attitude during the eclipse. After the set point of the secondary heater controller was gradually increased from 8 C to 8.7 C, there was no temperature droop for over four months.

Choi, Michael K.↗

High-Fidelity Neutronics Model of a Realistic Heat Pipe Microreactor Report

The creation of a digital twin requires two parallel products: a virtual model and a physical asset. This report details the development the high-fidelity reactor physics model of a realistic heat pipe micro reactor for the virtual model. The realistic heat pipe micro reactor provides a generic model that research can utilize to make safeguards considerations. The model will be leveraged for capturing diversion and misuse scenarios expected to take place in a microreactor. A python wrapper has been developed to rapidly explore various acquisition pathways by manipulating the reactor physics model on-the-fly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transverse flat-plate heat pipe experiment (S1005)

The objective of this experiment is to evaluate the zero-g performance of a number of transverse flat plate heat pipe modules. Performance will include the transport capability of the pipes, the temperature drop, and the ability to maintain temperature over varying duty cycles and environments. Additionally, performance degradation, if any, will be monitored over the length of the Long Duration Exposure Facility (LDEF) mission. This information is necessary if heat pipes are to be considered for system designs where they offer benefits not available with other thermal control techniques.

Owen, J. W.↗

Electrohydrodynamic heat pipe research

Experimental and theoretical applications to electrohydrodynamic heat pipe (EHDHP) research are presented. Two problems in the research which are discussed are the prediction of the effective thermal conductance of an EHDHP with threaded grooves for fluid distribution to the evaporator of an EHDHP. Hydrodynamic equations are included along with a discussion of boundary conditions and burn-out conditions. A discussion of the theoretical and experimental results is presented.

Jones, T. B.↗

Investigation of the Temperature Hysteresis Phenomenon of a Loop Heat Pipe

The temperature hysteresis phenomenon of a Loop Heat Pipe (LHP) was experimentally investigated. The temperature hysteresis was identified by the fact that the operating temperature depends upon not only the imposed power but also the previous history of the power variation. The temperature hysteresis could impose limitations on the LHP applications since the LHP may exhibit different steady-state operating temperatures at a given power input even when the condenser sink temperature remains unchanged. In order to obtain insight to this phenomenon, a LHP was tested at different elevations and tilts by using an elaborated power profile. A hypothesis was suggested to explain the temperature hysteresis. This hypothesis explains well the experimental observations. Results of this study provide a better understanding of the performance characteristics of the LHPS.

Kaya, Tarik↗

High Frequency Low Amplitude Temperature Oscillations in Loop Heat Pipe Operation

The operating temperature of a loop heat pipe (LHP) with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a finction of the evaporator power, condenser sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. This paper presents a study on the oscillation of the loop operating temperature with amplitudes on the order of one degree Kelvin and frequencies on the order of 10(exp -1) to 10(exp -2) Hertz. The source of the high frequency temperature oscillation is the fast movement of the vapor front in the condenser section, which usually occurs when the vapor front is near the condenser inlet or the condenser outlet. At these locations, the vapor front is unable to find a stable position for the given operating conditions, and will move back and forth. The movement of the vapor front causes the movement of the liquid in the condenser and the liquid line, leading to oscillations of the CC and the loop temperatures. Factors that affect the vapor front movement include evaporator power, condenser sink temperature, body forces and whether or the CC temperature is actively controlled. As long as there are no large thermal masses attached to the evaporator, the loop can self adjust rather quickly and the vapor front will move rapidly around the condenser inlet or outlet, leading to high frequency temperature oscillations. The amplitude of temperature oscillation is usually the largest in the liquid line, up to 20 degrees Kelvin in many cases, but diminishes to less than one degree Kelvin in the CC. Furthermore, the high frequency temperature oscillation can occur at any CC temperature when the right combination of the evaporator power and condenser sink temperature prevails.

Ku, Jentung↗

Potassium Rankine cycle vapor chamber (heat pipe) radiator study

A structurally integrated vapor chamber fin (heat pipe) radiator is defined and evaluated as a potential candidate for rejecting waste heat from the potassium Rankine cycle powerplant. Several vapor chamber fin geometries, using stainless steel construction, are evaluated and an optimum is selected. A comparison is made with an operationally equivalent conduction fin radiator. Both radiators employ NaK-78 in the primary coolant loop. In addition, the Vapor Chamber Fin (VCF) radiator utilizes sodium in the vapor chambers. Preliminary designs are developed for the conduction fin and VCF concepts. Performance tests on a single vapor chamber were conducted to verify the VCF design. A comparison shows the conduction fin radiator easier to fabricate, but heavier in weight, particularly as meteoroid protection requirements become more stringent. While the analysis was performed assuming the potassium Rankine cycle powerplant, the results are equally applicable to any system radiating heat to space in the 900 to 1400 F temperature range.

Gerrels, E. E.↗

The multistage heat pipe radiator - An advancement in passive cooling technology

Mathematical models were developed for one-, two-, and three-stage radiator systems to determine optimum stage areas and system performance as a function of such parameters as insulation effectiveness, cold stage temperature, and heat load to the cold and intermediate stages. This study shows that multistage radiator systems can be optimized on the basis of weight or projected area, and that cold stage temperatures as low as 15 K are theoretically possible with present technology levels for insulation emittance. For the baseline design, analyses were performed to determine optimum radiator fin geometry and heat pipe spacing as a function of temperature, material properties, and heat pipe weight. In addition, a ground test system was designed for the baseline design with heat rejection requirements of 10 MW at 35 K on the cold stage and 100 MW at the second stage.

Wilson, D. E.↗