Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

Miyoshi, K.↗

A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen muser's frequency offset and changes in environmental conditions. Data have been acquired over the past 20 months by recording the frequency offset of three NR atomic hydrogen masers along with the relative and absolute humidity, barometric pressure, and ambient temperature of the laboratory in which the masers are maintained. Correlational analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as functions of time for periods ranging from 5.5 to 17 days. Semi partial correlation coefficients as large as -0.9 have been fond between barometric pressure and maser frequency offset for data covering periods as long as a week. Maser frequency offset and barometric pressure were consistently found to change simultaneously. The correlation between humidity and frequency offset is less predictable, and the resulting semi partial correlation coefficients were usually small when compared with those derived from the relationship between pressure and frequency offset. The time delay between changes in humidity and correlated changes in maser frequency offset was found to vary extensively with no predictable pattern. Analysis of temperature data indicates that, in the most current design, temperature does not significant(y affect maser frequency offset in the laboratory environment. Thus, the results of the analyses disclose a significant statistical correlation between changes in maser frequency offset and changes in barometric pressure. The statistics also reveal some correlation between humidity and frequency offset, bat for reasons to be discussed, the effects of humidity should be considered secondary to the effects of changing barometric pressure.

R. A. Dragonette↗

Measurements and Modeling of Aerosol Absorption and Single Scattering Albedo at Ambient Relative Hum

Uncertainties in the aerosol single scattering albedo have been identified to be an important source of errors in current large-scale model estimates of the direct aerosol radiative forcing of climate. A number of investigators have obtained estimates of the single scattering albedo from a variety of remote sensing and in situ measurements during aerosol field experiments. During the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX, 1996) for example, estimates of the aerosol single scattering albedo were obtained (1) as a best-fit parameter in comparing radiative flux changes measured by airborne pyranometer to those computed from independently measured aerosol properties; (2) from estimates of the aerosol complex index of refraction derived using a combination of airborne sunphotometer, lidar backscatter and in situ size distribution measurements; and (3) from airborne measurements of aerosol scattering and absorption using nephelometers and absorption photometers. In this paper, we briefly compare the results of the latter two methods for two TARFOX case studies, since those techniques provide height-resolved information about the aerosol single scattering albedo. Estimates of the aerosol single scattering albedo from nephelometer and absorption photometer measurements require knowledge of the scattering and absorption humidification (i.e., the increase in these properties in response to an increase in ambient relative humidity), since both measurements are usually carried out at a relative humidity different from the ambient atmosphere. In principle, the scattering humidification factor can be measured, but there is currently no technique widely available to measure the absorption of an aerosol sample as a function of relative humidity. Frequently, for lack of better knowledge, the absorption humidification is assumed to be unity (meaning that there is no change in aerosol absorption due to an increase in ambient relative humidity). This assumption then enters the estimate of the single scattering albedo at ambient relative humidity. To investigate the validity of this assumption we have carried out modeling studies of the absorption humidification factor, assuming that the aerosols contain an insoluble soot core and a coating which determines its hygroscopic growth behavior. The aerosol optical properties are then computed on the basis of the shell/core particle morphology using a Mie-code for concentric shells. From basic physical principles, it is conceivable that aerosol absorption increases when an atmospheric aerosol particle collects a non-absorbing shell, since the soot core is then exposed to an increased (focused) electric field strength. Indeed, our preliminary modeling studies show that the absorption of an atmospheric aerosol particle composed of a soot core and an aqueous sulfuric acid shell may increase by a factor of 50% due to a change in ambient relative humidity from 30 to 95%. We will show how this increased absorption is a function of the initial particle size and soot mass fraction.

Redemann, J.↗

International Space Station Common Cabin Air Assembly Condensing Heat Exchanger Hydrophilic Coating Failures and Lessons Learned

The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within in the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings and potential remediation techniques will also be discussed.

Balistreri, Steven F.↗

Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring

An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power consumption (no heating for operation, no voltage applied to the sensor, only a voltmeter is needed to measure the output), is small in size, is simple to batch-fabricate, and is high in sensor yield. It is applicable in a wide humidity range, with improved operation in low humidity after the additives were added to the Nafion film. Through further improvement and development, the sensor can be used for aerospace applications such as fuel leak detection, fire detection, and environmental monitoring.

Hunter, Gary W.↗

International Space Station Common Cabin Air Assembly Condensing Heat Exchanger Hydrophilic Coating Operation, Recovery, and Lessons Learned

The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX in the ISS segments, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the ISS cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings as well as remediation and recovery of the full heat exchanger will be discussed.

Balistreri, Steven F.↗

Total Temperature Measurements in Icing Cloud Flows Using a Rearward Facing Probe

This paper reports on temperature and humidity measurements from a series of ice-crystal icing tunnel experiments conducted in June 2018 at the Propulsion Systems Laboratory at the NASA Glenn Research Center. The tests were fundamental in nature and were aimed at investigating the icing processes on a two-dimensional NACA0012 airfoil subjected to artificially generated icing clouds. Prior to the tests on the airfoil, a suite of instruments, including total temperature and humidity probes, were used to characterize the thermodynamic flow and icing cloud conditions of the facility. Two different total temperature probes were used in these tests which included a custom designed rearward facing probe and a commercial self-heating total temperature probe. The rearward facing probe, the main total temperature probe, was designed to reduce and mitigate the contaminating effects of icing and ingestion of ice crystals and water droplets at the probe's inlet. The probe also serves as an air-sample inlet for a light absorption based humidity measurement. The paper includes a section which discusses total temperature and humidity measurement considerations, and another section which provides an analysis of the main probe's performance characteristics. A computational fluid dynamic model of the flow around the probe was also conducted to gain insight into the trajectory of the flow entering the probe inlet. The experiments included a series of tests in which the relative humidity of the facility flow was swept through with increasingly larger values. The data showed that the rearward facing probe can reasonably capture the flow's total temperature and humidity under mild to moderate icing conditions but produces anomalous results under more intense icing conditions. The experimental data was also compared to an in-house developed thermodynamic model which takes into account the interaction of the main flow with the icing cloud. Comparison to the thermodynamic model showed that the rearward facing probe measured the predicted trends.

Agui, Juan H.↗

Responses of Compound Daytime and Nighttime Warm-Dry and Warm-H Events to Individual Anthropogenic Forcings

Daytime heat is often associated with reduced soil moisture and cloud cover, while nighttime heat is connected to high humidity and increased cloud cover. Due to these differing mechanisms, compound daytime and nighttime heat events may respond differently to major anthropogenic forcings (greenhouse gases, anthropogenic aerosols, land-use and land-cover change). Here, we use GISS ModelE2.1-G historical single-forcing runs from 1955 to 2014 to examine how individual anthropogenic forcings affect compound heat events—specifically warm daytime and nighttime temperatures compounded with dry precipitation or high humidity conditions. We show that greenhouse gases alone amplify the natural frequency of warm-dry events by 1.5–5 times and warm-humid events by 2–9 times in tropical and extratropical latitudes. Conversely, aerosols and land-use/land-cover change reduce the frequency of these events, resulting in more modest increases and in some regions, declines, in the historical 'all-forcings' scenario. Individually, aerosol effects are stronger and more widespread compared to land-use, oftentimes reducing the natural frequency of these events by 60%–100%. The responses of these compound events are primarily driven by changes in daytime and nighttime temperatures through large-scale warming via greenhouse gases and cooling from aerosols and land-use/land-cover change. However, changes in warm-dry events are amplified in regions with concurrent precipitation declines (e.g. Central America, Mediterranean regions) and warm-humid events are amplified by global concurrent humidity increases. Additionally, we find differences between daytime and nighttime compound responses in the historical experiment that can be traced back to the individual forcings. In particular, aerosols produce a greater cooling effect on daytime relative to nighttime temperatures, which notably results in a historical reduction of Northern Hemisphere daytime warm-dry events relative to natural conditions. Our analysis provides a more comprehensive understanding of the significant impacts of different anthropogenic climate forcings on daytime and nighttime warm-dry and warm-humid events, informing future risk and impact assessments.

Anthropogenic forcings↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Temperature lapse rate and methane in Titan's troposphere

We have reanalyzed the Voyager radio occultation data for Titan, examining two alternative approaches to methane condensation. In one approach, methane condensation is facilitated by the presence of nitrogen because nitrogen lowers the condensation level of a methane/nitrogen mixture. The resulting enhancement in methane condensation lowers the upper limit on surface relative humidity of methane obtained from the Voyager occultation data from 0.7 to 0.6. We conclude that in this case the surface relative humidity of methane lies between 0.08 and 0.6, with values close to 0.6 indicated. In the other approach, methane is allowed to become supersaturated and reaches 1.4 times saturation in the troposphere. In this case, surface humidities up to 100% are allowed by the Voyager occultation data, and thus the upper limit must be set by other considerations. We conclude that if supersaturation is included, then the surface relative humidity of methane can be any value greater than 0.08--unless a deep ocean is present, in which case the surface relative humidity is limited to less than 0.85. Again, values close to 0.6 are indicated. Overall, the tropospheric lapse rate on Titan appears to be determined by radiative equilibrium. The lapse rate is everywhere stable against dry convection, but is unstable to moist convection. This finding is consistent with a supersaturated atmosphere in which condensation-and hence moist convection-is inhibited.

Methane/analysis↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Surface-Enhanced Raman Detection of the CO 2 Moisture Swing

The development of scalable, energy-efficient carbon dioxide (CO 2 ) capture technologies is critical for achieving net-zero emissions. Moisture swing (MS) sorbents offer a promising alternative to traditional thermal regeneration methods by enabling reversible CO 2 binding through humidity-driven ion hydrolysis. In this study, we investigate the anion speciation dynamics in two classes of MS materials─an anion-exchange resin with a bicarbonate anion and activated carbon impregnated with potassium bicarbonate salt─using both sorption measurements and in situ surface-enhanced Raman spectroscopy (SERS). Ni-coated Ag nanowires were employed as SERS substrates to enhance signal intensity and enable the real-time detection of carbonate (CO 3 2– ), bicarbonate (HCO 3 – ), and hydroxide (OH – ) species under controlled humidity conditions in both air and nitrogen atmospheres. The results reveal humidity-dependent interconversion between anionic species with significant spectral shifts confirming the reversible hydrolysis reactions that drive the MS mechanism. Under humid conditions, we observed the depletion of bicarbonate signals and a concurrent increase in carbonate species, consistent with moisture-induced desorption of CO 2 . With the activated carbon samples, we further observed the formation of hydroxide. These findings not only validate the mechanistic models of humidity-driven anion exchange in MS sorbents but also demonstrate the practical potential of SERS as an operando diagnostic tool for monitoring CO 2 capture media. The ability to resolve and semiquantitatively evaluate the reversible transformation of carbonate, bicarbonate, and hydroxide ions under realistic environmental conditions provides valuable insight for the rational design, performance optimization, and quality control of next-generation sorbent materials for direct air capture applications.

CO2 capture↗

Disentangling Oxygen and Water Vapor Effects on Optoelectronic Properties of Monolayer Tungsten Disulfide

By understanding how the environmental composition impacts the optoelectronic properties of transition metal dichalcogenide monolayers, we demonstrate that simple photoluminescence (PL) measurements of tungsten disulfide (WS 2 ) monolayers can differentiate relative humidity environments. In this paper, we examine the PL and photoconductivity of chemical vapor deposition grown WS 2 monolayers under three carefully controlled environments: inert gas (N 2 ), dry air (O 2 in N 2 ), and humid nitrogen (H 2 O vapor in N 2 ). The WS 2 PL is measured as a function of 532 nm laser power and exposure time and can be decomposed into the exciton, trion, and lower energy state(s) contributions. Under continuous illumination in either O 2 or H 2 O vapor environment, we find dramatic (and reversible) increases in PL intensity relative to the PL in an inert environment. The PL bathochromically shifts in an O 2 environment and is dominated by increased trion emission and diminished exciton emission. In contrast, the WS 2 PL increase in a H 2 O environment results from an overall increase in emission from all spectral components where the exciton contribution dominates. The drastic increases in PL are anticorrelated with corresponding decreases in photoconductivity, as measured by time-resolved microwave conductivity. The results suggest that both O 2 and H 2 O react photochemically with the WS 2 monolayer surface, modifying the optoelectronic properties, but do so via distinct pathways. Thus, we use these optoelectronic differences to differentiate the amount of humidity in the air, which we show with 0%, 40%, and 80% relative humidity environments. This deeper understanding of how ambient conditions impact WS 2 monolayers enables novel humidity sensors as well as a better understanding of the correlation between TMDC surface chemistry, light emission, and photoconductivity. Moreover, these WS 2 measurements highlight the importance of considering the impact of the local environment on reported results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Harvest Intensity Effects on Carbon Stocks and Biodiversity Are Dependent on Regional Climate in Douglas-Fir Forests of British Columbia

Temperate forests provide crucial ecosystems services as living sinks for atmospheric carbon (C) and repositories of biodiversity. Applying harvesting at intensities that minimize losses offers one means for mitigating global change. However, little is known of overstory retention levels that best conserve ecosystem services in different regional climates, and likewise as climate changes. To quantify the effect of harvest intensity on C stocks and biodiversity, we compared five harvesting intensities (clearcutting, seedtree retention, 30% patch retention, 60% patch retention, and uncut controls) across a climatic aridity gradient that ranged from humid to semi-arid in the Douglas-fir (Pseudotsuga menziesii) forests of British Columbia. We found that increased harvesting intensity reduced total ecosystem, above ground, and live tree C stocks 1 year post-harvest, and the magnitude of these losses were negatively correlated with climatic aridity. In humid forests, total ecosystem C ranged from 50% loss following clearcut harvest, to 30% loss following large patch retention harvest. In arid forests this range was 60 to 8% loss, respectively. Where lower retention harvests are sought, the small patch retention treatment protected both C stocks and biodiversity in the arid forests, whereas the seedtree method performed as well or better in the humid forests. Below ground C stocks declined by an average of 29% after harvesting, with almost all of the loss from the forest floor and none from the mineral soil. Of the secondary pools, standing and coarse deadwood declined in all harvesting treatments regardless of cutting intensity or aridity, while C stocks in fine fuels and stumps increased. The understory plant C pool declined across all harvesting intensities in the humid forests, but increased in arid forests. Shannon’s diversity and richness of tree and bryoid species declined with harvesting intensity, where tree species losses were greatest in the humid forests and bryoid losses greatest in arid forests. Shrub and herb species were unaffected. This study showed that the highest retention level was best at reducing losses in C stocks and biodiversity, and clearcutting the poorest, and while partial retention of canopy trees can reduce losses in these ecosystem services, outcomes will vary with climatic aridity.

54 ENVIRONMENTAL SCIENCES↗

Acoustic sensor engineering evaluation test report

Two types of one-inch diameter sound pressure level sensors, which are candidates for monitoring ambient noise in the shuttle orbiter crew compartment during rest periods, were exposed to temperature, passive humidity, and vibration. One unexposed sensor of each type served as a reference unit. Except for the humidity exposures, each of the three capacitive microphones was individually tested in sequence with the essential voltage power supply and preamplifier. One unit exibited anomalous characteristics after the humidity exposure but returned to normal after being dried in an oven at 115 deg for two hours. Except for the humidity exposures, each of the three piezoelectric microphones was individually tested with a laboratory type amplifier. Two apparent failures occurred during these tests. The diaphragm on one was found ruptured after the fourth cycle of the humidity test. A second sensor showed an anomaly after the random vibration tests at which time its sensitivity was consistent at about one-half its former value.

Phillips, E. L., Jr.↗