Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOSPITAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Feature‐shared adaptive‐boost deep learning for invasiveness classification of pulmonary subsolid nodules in CT images

Purpose In clinical practice, invasiveness is an important reference indicator for differentiating the malignant degree of subsolid pulmonary nodules. These nodules can be classified as atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC). The automatic determination of a nodule's invasiveness based on chest CT scans can guide treatment planning. However, it is challenging, owing to the insufficiency of training data and their interclass similarity and intraclass variation. To address these challenges, we propose a two‐stage deep learning strategy for this task: prior‐feature learning followed by adaptive‐boost deep learning. Methods The adaptive‐boost deep learning is proposed to train a strong classifier for invasiveness classification of subsolid nodules in chest CT images, using multiple 3D convolutional neural network (CNN)‐based weak classifiers. Because ensembles of multiple deep 3D CNN models have a huge number of parameters and require large computing resources along with more training and testing time, the prior‐feature learning is proposed to reduce the computations by sharing the CNN layers between all weak classifiers. Using this strategy, all weak classifiers can be integrated into a single network. Results Tenfold cross validation of binary classification was conducted on a total of 1357 nodules, including 765 noninvasive (AAH and AIS) and 592 invasive nodules (MIA and IAC). Ablation experimental results indicated that the proposed binary classifier achieved an accuracy of with an AUC of 81.3 . These results are superior compared to those achieved by three experienced chest imaging specialists who achieved an accuracy of , , and , respectively. About 200 additional nodules were also collected. These nodules covered 50 cases for each category (AAH, AIS, MIA, and IAC, respectively). Both binary and multiple classifications were performed on these data and the results demonstrated that the proposed method definitely achieves better performance than the performance achieved by nonensemble deep learning methods. Conclusions It can be concluded that the proposed adaptive‐boost deep learning can significantly improve the performance of invasiveness classification of pulmonary subsolid nodules in CT images, while the prior‐feature learning can significantly reduce the total size of deep models. The promising results on clinical data show that the trained models can be used as an effective lung cancer screening tool in hospitals. Moreover, the proposed strategy can be easily extended to other similar classification tasks in 3D medical images.

Wang, Jun↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Convergent behavior of extended stalk regions from staphylococcal surface proteins with widely divergent sequence patterns

Staphylococcus epidermidis and Staphylococcus aureus are highly problematic bacteria in hospital settings. A major challenge is their ability to form biofilms on abiotic or biotic surfaces. Biofilms are well-organized, multicellular bacterial aggregates that resist antibiotic treatment and often lead to recurrent infections. Bacterial cell wall-anchored (CWA) proteins are important players in biofilm formation and infection. Many have putative stalk-like regions or regions of low complexity near the cell wall-anchoring motif. Recent work demonstrated the strong propensity of the stalk region of S. epidermidis accumulation-associated protein (Aap) to remain highly extended under solution conditions that typically induce compaction. This behavior is consistent with the expected function of a stalk-like region that is covalently attached to the cell wall peptidoglycan and projects the adhesive domains of Aap away from the cell surface. In this study, we evaluate whether the ability to resist compaction is a common theme among stalk regions from various staphylococcal CWA proteins. Circular dichroism spectroscopy was used to examine secondary structure changes as a function of temperature and cosolvents along with sedimentation velocity analytical ultracentrifugation, size-exclusion chromatography, and SAXS to characterize structural characteristics in solution. All stalk regions tested are intrinsically disordered, lacking secondary structure beyond random coil and polyproline type II helix, and they all sample highly extended conformations. Remarkably, the Ser-Asp dipeptide repeat region of SdrC exhibited nearly identical behavior in solution when compared to the Aap Pro/Gly-rich region, despite highly divergent sequence patterns, indicating conservation of function by various distinct staphylococcal CWA protein stalk regions.

59 BASIC BIOLOGICAL SCIENCES↗

Decision-making Framework to Support the End-of-Life Management of High-Activity Radioactive Sources

Sealed radioactive sources are used for an extremely wide range of purposes, including as radiation sources in various nuclear facilities, universities, hospitals, biomedical and industrial applications, as well as for geological prospecting and exploration. The proper management of these sealed radioactive sources once they have reached their end-of-life is still a global challenge. Very few field-tested Mobile Hot Cells (MHC) exist in the world to support the end-of-life management of disused high-activity radioactive sources. One of the critical challenges that a source recovery team encounters on each site is to find adequate space, and access to that space to complete the staging and recapture process with a MHC; this process is tedious, uncertain, and time-consuming. Therefore, it is essential to understand the planning and management of the MHC setup and takedown. Currently, there isn't an single capable planning tool that will provide an effective medium to plan, inform, educate, and communicate knowledge about the environment where the MHC will be deployed. We present a novel approach for the planning and management of the deployment of the MHC to several different sites that relies on technology. Furthermore, this planning tool will support collaboration, promote information sharing, and foster better decision making processes, resulting in a more efficient, and reliable setup and source recovery with the MHC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular findings on cross-sectional imaging: spectrum of incidental and critical findings and clinical relevance for the abdominal radiologist

Although not the primary focus of the exams, cardiovascular structures are included to some extent on all abdominal or whole-body cross-sectional studies. Cardiovascular findings often present incidentally and may range from chronic to acute and emergent pathologies. Among the most common cardiovascular findings are the presence of cardiac calcifications, most commonly coronary, which correlate with the presence of coronary artery and valvular disease. Signs of myocardial ischemia, both acute and chronic, and its complications may also be visualized. Cardiac filling defects most commonly represent thrombus and are associated with systemic arterial embolic complications. Pericardial findings often manifest as effusion or thickening, which may lead to hemodynamic consequences visible at imaging. Incidental pulmonary emboli and systemic venous thrombi may be incidentally detected, particularly in hospitalized and oncologic patients, and warrant immediate attention. This review will highlight the appearance of common and important incidental cardiovascular findings and related pitfalls and discuss reporting and follow-up recommendations relevant to the abdominal radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT and MRI features of undifferentiated carcinomas with osteoclast-like giant cells of the pancreas: a case series

Purpose: The purpose of this case series was to describe computed tomography (CT) and magnetic resonance imaging (MRI) features of undifferentiated carcinoma with osteoclast-like giant cells of the pancreas. Methods: Institutional ethics review board approval was obtained, and informed consent was waived for this case series. We reviewed CT and MRI of patients with pathologically confirmed undifferentiated carcinoma with osteoclast-like giant cells of the pancreas found in the medical records of our hospital between 2006 and 2016. Results: Seven patients (3 males and 4 females; age, 59–82 years (mean, 71)) with confirmation by surgical resection (n = 3) or biopsy (n = 4) were identified. They underwent CT (n = 7) and MRI (n = 6). The tumors 26–83 mm in diameter (mean, 44 mm) were located in the head (n = 4) or body (n = 3) of the pancreas. They were demonstrated as lower attenuation areas relative to the adjacent pancreas on CT images obtained in both pancreatic and portal vein phases (n = 7) with a well-defined smooth margin (n = 5). They were demonstrated as hypointense areas relative to the pancreas on T2-weighted images (n = 4) and T2*-weighted images (n = 4) and diffusion-weighted images (n = 3). They contained hemosiderin deposits on histology (n = 7). Conclusions: Undifferentiated carcinoma with osteoclast-like giant cells of the pancreas might be present as low attenuation areas with a well-defined smooth margin on CT images obtained in pancreatic and portal vein phases, and hypointense areas on T2-, T2*-, and diffusion-weighted images caused by hemosiderin deposits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinicopathological findings and imaging features of intraductal papillary neoplasm of the bile duct: comparison between contrast-enhanced ultrasound and contrast-enhanced computed tomography

Purpose: Intraductal papillary neoplasms of the bile duct (IPNBs) are a group of rare lesions with uncertain clinical findings and imaging features. We aim to investigate the clinicopathological features and imaging findings of IPNBs on contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT). Methods: From February 2005 to March 2018, 30 patients with pathologically confirmed IPNBs were retrospectively identified in our hospital. Demographic, clinical, and pathological data, CEUS and CECT features and surgical strategies were analyzed. Results: The most common clinical manifestations were abdominal pain (53.3%), jaundice (23.3%), and acute cholangitis (10.0%). Among all lesions, 5/30 (16.7%) lesions presented as dilated bile ducts only, while 13/30 (43.3%) lesions presented as dilated bile ducts with intraductal papillary masses, and 12/30 (40.0%) presented as solid masses with dilated bile ducts. For the 20 patients who underwent both CEUS and CECT, 18 lesions were hyperenhanced on CEUS, and 17 lesions were hyperenhanced on CECT in the arterial phase. In total, 16 and 18 lesions showed washout in the portal and late phases on CEUS, while the corresponding number of lesions that showed washout in the portal and late phases on CECT were 11 and 13. Twelve lesions (40.0%) showed atypical hyperplasia, while 16/30 (53.3%) lesions underwent malignant transformations. Conclusions: There are 3 major forms of IPNBs on grayscale ultrasound, including diffusely dilated bile ducts without visible mass; focal dilated bile duct with intraductal papillary masses; and solid mass surrounded by dilated bile ducts. The enhancement patterns of IPNBs on CEUS and on CECT were consistent. IPNB has a high malignant potential, and patients should be treated with surgical resection after the diagnosis is established.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent use of NSAID and NOAC medications are associated with a positive CT arteriogram

Background: Computed tomography angiography (CTA) is a diagnostic modality utilized in patients with suspected active lower gastrointestinal (GI) bleeding. CTA use in clinical practice is limited by the risk of contrast-induced nephropathy, and the loss of patients from direct physician observation while undergoing the test. Identifying clinical predictors of a positive result would be useful in guiding physician utilization of CTA studies. Methods: We performed a single-center retrospective study to determine which clinical predictors are associated with a positive CTA. Binary logistical regression modeling was used to identify the independent predictors and the results were expressed as adjusted odds ratios with corresponding 95% CI . Results: 262 patients met inclusion criteria and there were 61 (23.3%) positive CTA exams. In unadjusted analysis those who were CTA positive were more likely to require management in the intensive care unit (85.2% vs. 14.8%, p < 0.01) and being CTA positive was associated with a significantly increased in-hospital mortality (14.8% vs. 4.5%, p < 0.01). The use of a novel oral anticoagulant (NOAC) in the week prior to presentation was associated with a positive CTA after adjustment for confounders (adjusted odds ratio = 3.89; 95% CI 1.05–14.43). Similarly, the use of a non-steroidal anti-inflammatory drug (NSAID) was associated with a positive CTA (OR 2.36; 1.03–5.41). Only 8% of patients experienced contrast-induced nephropathy. Conclusion: Use of either NOACs or NSAIDs in the previous week is independently associated with a positive CTA in the setting of acute lower GI bleeding. CTA exams appear to confer a low risk of contrast-induced nephropathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and {>=}6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Place of Arterial Embolization in Severe Blunt Hepatic Trauma: A Multidisciplinary Approach

This study evaluates the efficacy of arterial embolization (AE) for blunt hepatic traumas (BHT) as part of a combined management strategy based on the hemodynamic status of patients and CT findings. From 2000 to 2005, 84 patients were admitted to our hospital for BHT. Of these, 14 patients who had high-grade injuries (grade III [n = 2], grade IV [n = 9], grade V [n = 3]) underwent AE because of arterial bleeding and were included in the study. They were classified into three groups according to their hemodynamic status: (1) unresponsive shock, (2) shock improved with resuscitation, and (3) hemodynamic stability. Four patients (group 1) underwent, first, laparotomy with packing and, then, AE for persistent bleeding. Ten patients who were hemodynamically stable (group 1) or even unstable (group 2) underwent AE first, based on CT findings. AE was successful in all cases. The mortality rate was 7% (1/14). Only two angiography-related complications (gallbladder infarction) were reported. Liver-related complications (abdominal compartment syndrome and biliary complications) were frequent and often required secondary interventions. Our multidisciplinary approach for the management of BHT gives a main role to embolization, even for hemodynamically unstable patients. In this strategy AE is very efficient and has a low complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Iatrogenic and Traumatic Carotid Artery Dissection

This paper reports on the early and midterm results of endovascular treatment of acute carotid artery dissections, its specific problems, and its limitations. We encountered seven patients with symptomatic extracranial carotid artery dissection, three cases of which occurred after carotid endarterectomy, two after carotid angioplasty and stenting, and two after trauma. Balloon-expandable and self-expanding stents were placed using a transfemoral approach. Success in restoring the carotid lumen was achieved in all patients. No procedure-related complications occurred. All patients experienced significant clinical improvement while in the hospital and achieved complete long-term recovery. At follow-up (mean, 22.4 months), good luminal patency of the stented segments was observed. In conclusion, in this small series, primary stent-supported angioplasty seems to be a safe and effective strategy in the treatment of selected patients having acute traumatic extracranial carotid artery dissection, with excellent early and midterm results. Larger series and longer-term follow-up are required before definitive recommendations can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraosseous Venography with Carbon Dioxide in Percutaneous Vertebroplasty: Carbon Dioxide Retention in Renal Veins

The objective of the present study was to determine the frequency of gas retention in the renal vein following carbon dioxide intraosseous venography in the prone position and, while citing references, to examine its onset mechanisms. All percutaneous vertebroplasties performed at our hospital from January to December 2005 were registered and retrospectively analyzed. Of 43 registered procedures treating 79 vertebrae, 28 procedures treating 54 vertebrae were analyzed. Vertebral intraosseous venography was performed using carbon dioxide as a contrast agent in all percutaneous vertebroplasty procedures. In preoperative and postoperative vertebral CT, gas retention in the renal vein and other areas was assessed. Preoperative CT did not show gas retention (0/28 procedures; 0%). Postoperative CT confirmed gas retention in the renal vein in 10 of the 28 procedures (35.7%). Gas retention was seen in the right renal vein in 8 procedures (28.6%), in the left renal vein in 5 procedures (17.9%), in the left and right renal veins in 3 procedures (10.7%), in vertebrae in 22 procedures (78.6%), in the soft tissue around vertebrae in 14 procedures (50.0%), in the spinal canal in 12 procedures (42.9%), and in the subcutaneous tissue in 5 procedures (17.9%). In conclusion, in our study, carbon dioxide gas injected into the vertebra frequently reached and remained in the renal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Superior Mesenteric Artery Pseudoaneurysm and Fistula

The uncommon presentation of an arterioportal fistula (APF) involving the superior mesenteric artery (SMA) associated with a pseudoaneurysm represents a therapeutic challenge. We present the case of a 24-year-old female admitted to the hospital after multiple gunshot wounds to the abdomen; the patient underwent multiple surgeries and, in the process, developed a SMA pseudoaneurysm and fistula. The vascular interventional radiology team was consulted for treatment of the pseudoaneurysm and fistula. A covered stent was inserted percutaneously to exclude the APF and the pseudoaneurysm in a single procedure. The patient returned to our service after 21 months for a follow-up CT scan, which demonstrated the stent and the distal vasculature to be patent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palonosetron-A Single-Dose Antiemetic Adjunct for Hepatic Artery Radioembolization: A Feasibility Study

Nausea and vomiting may occur in a significant minority of patients following hepatic artery embolization with yttrium-90 spheres (K. T. Sato et al. Radiology 247:507-515, 2008). This encumbers human and economic resources and undercuts the assertion that it is as a well-tolerated outpatient treatment. A single intravenous dose of palonosetron HCl was administered before hepatic artery embolization with yttrium-90 spheres to ameliorate posttreatment nausea and vomiting, in 23 consecutive patients. The patients were discharged the day of procedure on oral antiemetics, steroids, and blockers of gastric acid release. All patients had clinical and laboratory evaluation at 2 weeks after the procedure. The data were gathered and reviewed retrospectively. At 2-week follow-up, none reported significant nausea, vomiting, additional antiemetic use, need for parenteral therapy, hospital readmission, or palonosetron-related side effects. All patients recovered from postembolization symptoms within a week after treatment. In conclusion, this retrospective study suggests that single-dose palonosetron is feasible, safe, and effective for acute and delayed nausea and vomiting in this group of patients. The added cost may be offset by benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AngioJet Thrombectomy for Occluded Dialysis Fistulae: Outcome Data

This study evaluates AngioJet thrombectomy of occluded autogenous dialysis fistulae and polytetrafluoroethylene (PTFE) grafts in a UK hemodialysis population. Comparison is made with published data of alternative percutaneous thrombectomy methods. All patients with occluded dialysis fistulae who sought care at the Royal Liverpool University Hospital between October 2006 and June 2008 were included in the study. All patients were treated with the AngioJet Rheolytic Thrombectomy Device (Possis, Minneapolis, MN). Demographics, time of occlusion, adjunctive therapies, complications, and follow-up data have been prospectively recorded. A total of 64 thrombectomy procedures were performed in 48 patients. Forty-four autogenous fistulas were treated in 34 patients (19 brachiocephalic, 8 radiocephalic, and 7 transposed brachiobasilic). Twenty PTFE grafts were treated in 14 patients (9 brachioaxillary, 3 brachiocephalic loop grafts, 1 brachiobasilic, and 1 femoro-femoral). The average length of occlusion was 24 cm. Average time to intervention was 4 days. Immediate primary patency was 91%. Primary patency at 1, 3, and 6 months, respectively, was 71%, 60%, and 37%. Secondary patency at 3, 6, and 12 months was 87%, 77%, and 62%, respectively. Angioplasty was carried out in all procedures. Patients required stent insertion in 34 of the 64 thrombectomies to treat angioplasty-resistant stenoses. Complications included a puncture-site hematoma, and three angioplasty-related vein ruptures in one patient, all treated with covered stent grafts. Two cases of distal brachial arterial embolization were successfully treated by thrombosuction. AngioJet thrombectomy in dialysis access occlusion is safe and effective, comparing favorably with other methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Traumatic Inferior Gluteal Artery Aneurysm Managed with Emergency Transcatheter Thrombin Injection

Pseudoaneurysms of the inferior gluteal artery (IGA) are rare and are often caused by trauma. Treatment options vary and include surgery, ultrasound-guided percutaneous thrombin injection, and endovascular procedures such as stent-graft placement, coil embolization, and glue injection. We report a 70-year-old male who presented to the hospital after a road accident with a posttraumatic pseudoaneurysm that was treated by endovascular thrombin embolization. To the best of our knowledge, this is the first reported case of inferior gluteal artery false aneurysm treated by this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗