Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Compensating Faraday Depolarization by Magnetic Helicity in the Solar Corona

A turbulent dynamo in spherical geometry with an outer corona is simulated to study the sign of magnetic helicity in the outer parts. In agreement with earlier studies, the sign in the outer corona is found to be opposite to that inside the dynamo. Line-of-sight observations of polarized emission are synthesized to explore the feasibility of using the local reduction of Faraday depolarization to infer the sign of helicity of magnetic fields in the solar corona. This approach was previously identified as an observational diagnostic in the context of galactic magnetic fields. Based on our simulations, we show that this method can be successful in the solar context if sufficient statistics are gathered by using averages over ring segments in the corona separately for the regions north and south of the solar equator.

79 ASTRONOMY AND ASTROPHYSICS↗

Guided Formation of 3D Helical Mesostructures by Mechanical Buckling: Analytical Modeling and Experimental Validation

3D helical mesostructures are attractive for applications in a broad range of microsystem technologies due to their mechanical and electromagnetic properties as stretchable interconnects, radio frequency antennas, and others. Controlled compressive buckling of 2D serpentine-shaped ribbons provides a strategy to formation of such structures in wide ranging classes of materials (from soft polymers to brittle inorganic semiconductors) and length scales (from nanometer to centimeter), with an ability for automated, parallel assembly over large areas. The underlying relations between the helical configurations and fabrication parameters require a relevant theory as the basis of design for practical applications. In this work, an analytic model of compressive buckling in serpentine microstructures is presented based on the minimization of total strain energy that results from various forms of spatially dependent deformations. Experiments at micro- and millimeter scales, together with finite element analyses, have been exploited to examine the validity of developed model. The theoretical analyses shed light on general scaling laws in terms of three groups of fabrication parameters (related to loading, material, and 2D geometry), including a negligible effect of material parameters and a square root dependence of primary displacements on the compressive strain. Furthermore, analytic solutions were obtained for the key physical quantities (e.g., displacement, curvature and maximum strain). A demonstrative example illustrates how to leverage the analytic solutions in choosing the various design parameters, such that brittle fracture or plastic yield can be avoided in the assembly process.

36 MATERIALS SCIENCE↗

2D Crystal Engineering of Nanosheets Assembled from Helical Peptide Building Blocks

The successful integration of 2D nanomaterials into functional devices hinges on developing fabrication methods that afford hierarchical control across length scales of the entire assembly. We demonstrate structural control over a class of crystalline 2D nanosheets assembled from collagen triple helices. By lengthening the triple helix unit through sequential additions of Pro-Hyp-Gly triads, we achieved sub-angstrom tuning over the 2D lattice. These subtle changes influence the overall nanosheet size, which can be adjusted across the mesoscale size regime. The internal structure was observed by cryo-TEM with direct electron detection, which provides realspace high-resolution images, in which individual triple helices comprising the lattice can be clearly discerned. These results establish a general strategy for tuning the structural hierarchy of 2D nanomaterials that employ rigid, cylindrical structural units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Helical side chain chemistry of a peptoid‐based SP‐C analogue: Balancing structural rigidity and biomimicry

Abstract Surfactant protein C (SP‐C) is an important constituent of lung surfactant (LS) and, along with SP‐B, is included in exogenous surfactant replacement therapies for treating respiratory distress syndrome (RDS). SP‐C's biophysical activity depends upon the presence of a rigid C‐terminal helix, of which the secondary structure is more crucial to functionality than precise side‐chain chemistry. SP‐C is highly sequence‐conserved, suggesting that the β‐branched, aliphatic side chains of the helix are also important. Nonnatural mimics of SP‐C were created using a poly‐ N ‐substituted glycine, or “peptoid,” backbone. The mimics included varying amounts of α‐chiral, aliphatic side chains and α‐chiral, aromatic side chains in the helical region, imparting either biomimicry or structural rigidity. Biophysical studies confirmed that the peptoids mimicked SP‐C's secondary structure and replicated many of its surface‐active characteristics. Surface activity was optimized by incorporating both structurally rigid and biomimetic side chain chemistries in the helical region indicating that both characteristics are important for activity. By balancing these features in one mimic, a novel analogue was created that emulates SP‐C's in vitro surface activity while overcoming many of the challenges related to natural SP‐C. Peptoid‐based analogues hold great potential for use in a synthetic, biomimetic LS formulation for treating RDS.

Brown, Nathan J.↗

The N‐terminal intrinsically disordered region of Ncb5or docks with the cytochrome b 5 core to form a helical motif that is of ancient origin

Abstract NADH cytochromeb 5 oxidoreductase (Ncb5or) is a cytosolic ferric reductase implicated in diabetes and neurological conditions. Ncb5or comprises cytochromeb 5 (b 5 ) and cytochromeb 5 reductase (b 5 R) domains separated by a CHORD‐Sgt1 (CS) linker domain. Ncb5or redox activity depends on proper inter‐domain interactions to mediate electron transfer from NADH or NADPH via FAD to heme. While full‐length human Ncb5or has proven resistant to crystallization, we have succeeded in obtaining high‐resolution atomic structures of theb 5 domain and a construct containing the CS andb 5 R domains (CS/b 5 R). Ncb5or also contains an N‐terminal intrinsically disordered region of 50 residues that has no homologs in other protein families in animals but features a distinctive, conserved L 34 MDWIRL 40 motif also present in reduced lateral root formation (RLF) protein in rice and increased recombination center 21 in baker's yeast, all attaching to ab 5 domain. After unsuccessful attempts at crystallizing a human Ncb5or construct comprising the N‐terminal region naturally fused to theb 5 domain, we were able to obtain a high‐resolution atomic structure of a recombinant rice RLF construct corresponding to residues 25–129 of human Ncb5or (52% sequence identity; 74% similarity). The structure reveals Trp 120 (corresponding to invariant Trp 37 in Ncb5or) to be part of an 11‐residue α‐helix (S 116 QMDWLKLTRT 126 ) packing against two of the four helices in theb 5 domain that surround heme (α2 and α5). The Trp 120 side chain forms a network of interactions with the side chains of four highly conserved residues corresponding to Tyr 85 and Tyr 88 (α2), Cys 124 (α5), and Leu 47 in Ncb5or. Circular dichroism measurements of human Ncb5or fragments further support a key role of Trp 37 in nucleating the formation of the N‐terminal helix, whose location in the N/b 5 module suggests a role in regulating the function of this multi‐domain redox enzyme. This study revealed for the first time an ancient origin of a helical motif in the N/b 5 module as reflected by its existence in a class of cytochromeb 5 proteins from three kingdoms among eukaryotes.

Biochemistry & Molecular Biology↗

Measurement of the W boson helicity in events with a single reconstructed top quark in pp collisions at $ \sqrt{s}=8 $ TeV

We presented a measurement of the W boson helicity, where the W boson originates from the decay of a top quark produced in pp collisions. The event selection, optimized for reconstructing a single top quark in the final state, requires exactly one isolated lepton (muon or electron) and exactly two jets, one of which is likely to originate from the hadronization of a bottom quark. The analysis is performed using data recorded at a center-of-mass energy of 8 TeV with the CMS detector at the CERN LHC in 2012. We also found that the data sample corresponds to an integrated luminosity of 19.7 fb -1 . The measured helicity fractions are F L = 0.298 ± 0.028 (stat) ± 0.032(syst), F 0 = 0.720 ± 0.039 (stat) ± 0.037(syst), and F R = -0.018 ± 0.019 (stat) ± 0.011(syst). These results are used to set limits on the real part of the tWb anomalous couplings, g L and g R .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Helicity methods for high multiplicity subleading soft and collinear limits

The factorization of multi-leg gauge theory amplitudes in the soft and collinear limits provides strong constraints on the structure of amplitudes, and enables efficient calculations of multi-jet observables at the LHC. There is significant interest in extending this understanding to include subleading powers in the soft and collinear limits. While this has been achieved for low point amplitudes, for higher point functions there is a proliferation of variables and more complicated phase space, making the analysis more challenging. By combining the subleading power expansion of spinor-helicity variables in collinear limits with consistency relations derived from the soft collinear effective theory, we show how to efficiently extract the subleading power leading logarithms of N-jet event shape observables directly from known spinor-helicity amplitudes. At subleading power, we observe the presence of power law singularities arising solely from the expansion of the amplitudes, which for hadron collider event shapes lead to the presence of derivatives of parton distributions. The techniques introduced here can be used to efficiently compute the power corrections for N-jettiness subtractions for processes involving jets at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Covariance Matrix for Helicity Couplings

In this paper, the helicity couplings at Q 2 = 0 for excited baryonic states have been determined in the past, but no information is available regarding their correlations that are relevant for comparison to theory. We present here our calculation of such correlations between the helicity couplings. Finally, they contain information for quantitative comparisons with theoretical values, they can be used to quantify the impact of polarization observables, and can help design new experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin Asymmetries and Helicity Amplitudes in Photo-Production from Polarized Neutrons

Pseudoscalar meson photoproduction experiments lead the search for an expanded $N^*$ spectroscopy that is required by lattice solutions of QCD. Extensive data have been collected with proton targets that can potentially over-determine the production amplitude and allow a search for weak resonances. In contrast, data on photoproduction from neutrons is drastically limited. Both are needed since the $\gamma p N^*$ and $\gamma n N^*$ photo-couplings to I = 1/2 states are different and provide complementary information on the mechanisms for resonance excitation. The main subtleties in experiments with an effective polarized neutron target are reviewed. The considerable impact of new polarization data on multipole analyses are discussed, using the example of recent $\pi^- p$ measurements of the beam-target helicity asymmetry ($E$) from polarized $H\!D$ in CLAS at Jefferson Lab. Here, new partial wave analyses incorporating these data have found significant changes in helicity amplitudes of some established resonances, and signatures of weak resonances that previously were observed only in hyperon decay channels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diabatic visualization shows effects of micro-fins on evaporation of R410A: Smooth, axial micro-fin, and helical micro-fin tubes

A novel approach to visualize the flow boiling inside a clear micro-fin tube under diabatic conditions is presented. Transparent smooth, axial micro-fin, and helical micro-fin tubes are made by 3D printing. The 3D printed tube is placed inside a glass tube and heated by the transparent secondary fluid flowing between the two tubes for providing the evaporation conditions and transparency. R410A flow boiling and the flow patterns in the three geometries captured with a high speed camera are compared. The experimental results show that micro-fin geometry influences flow behavior. Bubbles are mainly generated in the groove region due to a higher superheat than the fin region. Some of the liquid refrigerant is trapped in the grooves of the upper part of the micro-fin tube when the slug flow is present, and bubbles are generated in this thin liquid layer. In addition, the bubbles in the helical micro-fin tube are easier to merge because of the obstacle of the fin geometry for the bubble flowing path. As the two bubble merge, the conversion of surface free energy causes the bubble to travel with a higher velocity.

3D printed↗

Phase II Study of Preoperative Helical Tomotherapy for Rectal Cancer

Purpose: To explore the efficacy and toxicity profile of helical tomotherapy in the preoperative treatment of patients with rectal cancer. Patients and Methods: Twenty-four patients with T3/T4 rectal cancer were included in this nonrandomized noncontrolled study. A dose of 46 Gy in daily fractions of 2 Gy was delivered to the presacral space and perineum if an abdominoperineal resection was deemed necessary. This dose was increased by a simultaneous integrated boost to 55.2 Gy when the circumferential resection margin was less than 2 mm on magnetic resonance imaging. Acute toxicity was evaluated weekly. Metabolic response was determined in the fifth week after the end of radiotherapy by means of fluorodeoxyglucose-positron emission tomography scan. A metabolic response was defined as a decrease in maximal standardized uptake value of more than 36%. Results: The mean volume of small bowel receiving more than 15 Gy and mean bladder dose were 227 ml and 20.8 Gy in the no-boost group and 141 ml and 21.5 Gy in the boost group. Only 1 patient developed Grade 3 enteritis. No other Grade 3 or 4 toxicities were observed. Two patients developed an anastomotic leak within 30 days after surgery. The metabolic response rate was 45% in the no-boost group compared with 77% in the boost group. All except 1 patient underwent an R0 resection. Conclusions: Helical tomotherapy may decrease gastrointestinal toxicity in the preoperative radiotherapy of patients with rectal cancer. A simultaneous integrated radiation boost seems to result in a high metabolic response rate without excessive toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Quality Assurance

Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Total-Marrow Irradiation Using Helical Tomotherapy in Patients With Multiple Myeloma and Acute Leukemia Undergoing Hematopoietic Cell Transplantation

Purpose: Total-body irradiation (TBI) has an important role in patients undergoing hematopoietic cell transplantation (HCT), but is associated with significant toxicities. Targeted TBI using helical tomotherapy results in reduced doses to normal organs, which predicts for reduced toxicities compared with standard TBI. Methods and Materials: Thirteen patients with multiple myeloma were treated in an autologous tandem transplantation Phase I trial with high-dose melphalan, followed 6 weeks later by total-marrow irradiation (TMI) to skeletal bone. Dose levels were 10, 12, 14, and 16 Gy at 2 Gy daily/twice daily. In a separate allogeneic HCT trial, 8 patients (5 with acute myelogenous leukemia, 1 with acute lymphoblastic leukemia, 1 with non-Hodgkin's lymphoma, and 1 with multiple myeloma) were treated with TMI plus total lymphoid irradiation plus splenic radiotherapy to 12 Gy (1.5 Gy twice daily) combined with fludarabine/melphalan. Results: For the 13 patients in the tandem autologous HCT trial, median age was 54 years (range, 42-66 years). Median organ doses were 15-65% that of the gross target volume dose. Primarily Grades 1-2 acute toxicities were observed. Six patients reported no vomiting; 9 patients, no mucositis; 6 patients, no fatigue; and 8 patients, no diarrhea. For the 8 patients in the allogeneic HCT trial, median age was 52 years (range, 24-61 years). Grades 2-3 nausea, vomiting, mucositis, and diarrhea were observed. In both trials, no Grade 4 nonhematologic toxicity was observed, and all patients underwent successful engraftment. Conclusions: This study shows that TMI using helical tomotherapy is clinically feasible. The reduced acute toxicities observed compare favorably with those seen with standard TBI. Initial results are encouraging and warrant further evaluation as a method to dose escalate with acceptable toxicity or to offer TBI-containing regimens to patients unable to tolerate standard approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for {<=}1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Postmastectomy Treatment With Helical TomoTherapy

Purpose: To investigate the potential of helical tomotherapy for postmastectomy radiation therapy. Methods and Materials: By use of the TomoTherapy Hi-Art II treatment-planning system (TomoTherapy Inc., Madison, WI), helical tomotherapy dose plans were developed for 5 patients and compared with the mixed-beam (electron-photon) plans with which they had been treated. The TomoTherapy plans were evaluated by use of dose-volume quantities, tumor control probability, normal tissue complication probability (NTCP), and secondary cancer complication probability (SCCP). Results: The TomoTherapy plans showed better dose homogeneity in the planning treatment volume containing the chest wall and internal mammary nodes (p = 0.001) and eliminated the need for abutting fields. For the normal tissues, the TomoTherapy plans showed a smaller fractional volume receiving 20Gy or greater for the ipsilateral lung (p = 0.05), no change in NTCP for postradiation pneumonitis, increased SCCP for each lung and both lungs together (p < 0.02), no change in the volume of the heart receiving more than 15Gy, no change in NTCP for excess cardiac mortality, and a larger mean dose and SCCP in the contralateral breast (p < 0.001). For nonspecific tissues, the volume receiving between 5Gy and 25Gy and SCCP were both larger for the TomoTherapy plans (p < 0.01). Total SCCP was larger for the TomoTherapy plans (p = 0.001). Conclusions: Overall, the TomoTherapy plans had comparable tumor control probability and NTCP to the mixed-beam plans and increased SCCP. The TomoTherapy plans showed significantly greater dose homogeneity in the chest wall, which offers the potential for improved cosmesis after treatment. These factors have resulted in TomoTherapy often being the treatment of choice for postmastectomy radiation therapy in our clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity and Outcome Results of a Class Solution With Moderately Hypofractionated Radiotherapy in Inoperable Stage III Non-Small Cell Lung Cancer Using Helical Tomotherapy

Purpose: To prospectively assess the feasibility, toxicity, and local control of a class solution protocol of moderately hypofractionated tomotherapy in Stage III, inoperable, locally advanced non-small-cell lung cancer patients. Methods and Materials: Eligible patients were treated according to a uniform class solution (70.5 Gy in 30 fractions) with fixed constraints and priorities using helical tomotherapy. Toxicity monitoring was performed using the Radiation Therapy Oncology Group criteria and the National Cancer Institute Common Terminology Criteria and Adverse Events (CTCAE) version 3.0. Pulmonary function tests were performed at the start and repeated at 3 months after treatment. Results: Our class solution resulted in a deliverable plan in all 40 consecutive patients. Acute Grade 3 lung toxicity was seen in 10% of patients. Two patients died during acute follow-up with pulmonary toxicity. Correlations were found between changes in pulmonary function test results and mean lung dose or the lung volume receiving 20 Gy (V{sub 20}). The correlation was strongest for lung diffusion capacity for carbon monoxide. A V{sub 20} of >27% and >32% were predictive for Grades 2 and 3 acute lung toxicity respectively (p < 0.05). Late Grade 3 toxicity was exclusively pulmonary, with an incidence of 16%. Overall Grade 3 lung toxicity correlated with a mean lung dose of >18 Gy and a median lung dose of >5 Gy (p < 0.05). Median survival was 17 months, and the 1-year and 2-year local progression-free survivals were 66% and 50%, respectively. Conclusion: The current class solution using moderately hypofractionated helical tomotherapy in patients with locally advanced non-small-cell lung cancer is feasible. Toxicity was acceptable and in line with other reports on intensity-modulated radiotherapy. The local progression-free survival was encouraging considering the unselected population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Jaws and Dynamic Couch in Helical Tomotherapy

Purpose: To investigate the next generation of helical tomotherapy delivery with dynamic jaw and dynamic couch movements. Methods and Materials: The new technique of dynamic jaw and dynamic couch movements is described, and a comparative planning study is performed. Ten nasopharyngeal cancer patients with skull base infiltration were chosen for this comparison of longitudinal dose profiles using regular tomotherapy delivery, running-start-stop treatment, and dynamic jaw and dynamic couch delivery. A multifocal simultaneous integrated boost concept was used (70.4Gy to the primary tumor and involved lymph nodes; 57.4Gy to the bilateral cervical lymphatic drainage pathways, 32 fractions). Target coverage, conformity, homogeneity, sparing of organs at risk, integral dose, and radiation delivery time were evaluated. Results: Mean parotid dose for all different deliveries was between 24.8 and 26.1Gy, without significant differences. The mean integral dose was lowered by 6.3% by using the dynamic technique, in comparison with a 2.5-cm-field width for regular delivery and 16.7% with 5-cm-field width for regular delivery. Dynamic jaw and couch movements reduced the calculated radiation time by 66% of the time required with regular 2.5-cm-field width delivery (199 sec vs. 595 sec, p < 0.001). Conclusions: The current delivery mode of helical tomotherapy produces dose distributions with conformal avoidance of parotid glands, brain stem, and spinal cord. The new technology with dynamic jaw and couch movements improves the plan quality by reducing the dose penumbra and thereby reducing the integral dose. In addition, radiation time is reduced by 66% of the regular delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗