Two judging criteria to check validity of a model for filling gaps caused by incomplete geospatial data
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The nexus of food, energy, and water (FEW) systems is key to ensuring global sustainability in the face of climate change, population growth, and urbanization. To address FEW resources inequity among different regions and countries, transdisciplinary research networking becomes increasingly important for tackling this intractable, complex grand challenge. In contrast to interdisciplinary or multidisciplinary research, transdisciplinary research emphasizes the interactions of scientific, cognitive, and social factors from a top-down view. Intellectual and strategic integrations entail weaving scientific, socioeconomic, and political perspectives together into a new convergence model and fostering a shared vision and comparable assessment, though these goals might not be realistically achievable in the short term. This article summarizes major barriers to transdisciplinary research on FEW nexus grand challenges and possible solutions to be implemented at multiple levels of distinct social systems. Implementation of the solutions relies on not only top-down incentives of governments but also bottom-up initiatives of academic communities and individual researchers. The relevance of shared interests and visions between the research communities and the public is emphasized.
Achieving reliable real-time control in fusion plasma experiments requires strict timing guarantees across entire control algorithms. In earlier work by Abbate et al. (2023), we demonstrated the feasibility of neural-network-based control algorithms on the DIII-D tokamak using the internally developed open-source Keras2C library for model conversion into C (Conlin et al. (2021)). However, the initial implementations relied on data buffering and branching logic outside the neural network code, causing variability in execution times. Subsequent deployments on DIII-D and KSTAR—including the RTCAKENN algorithm for kinetic profile reconstruction—proved that minimizing branching and buffering throughout the pipeline yields consistent millisecond-level cycle times under real experimental conditions (Shousha et al. (2023)). However, keeping pace with rapidly evolving AI frameworks (e.g. PyTorch) is challenging. Finally, we, therefore, propose a community-driven open-source effort to expand the tool, enabling real-time deployment across diverse systems that require strictly bounded execution times.
Despite technological advances in radiation therapy (RT) and cancer treatment, patients still experience adverse effects. Proton therapy (PT) has emerged as a valuable RT modality that can improve treatment outcomes. Normal tissue injury is an important determinant of the outcome; therefore, for this review, we analyzed 2 databases: (1) clinical trials registered with ClinicalTrials.gov and (2) the literature on PT in PubMed, which shows a steady increase in the number of publications. Most studies in PT registered with ClinicalTrials.gov with results available are nonrandomized early phase studies with a relatively small number of patients enrolled. From the larger database of nonrandomized trials, we listed adverse events in specific organs/sites among patients with cancer who are treated with photons and protons to identify critical issues. The present data demonstrate dosimetric advantages of PT with favorable toxicity profiles and form the basis for comparative randomized prospective trials. A comparative analysis of 3 recently completed randomized trials for normal tissue toxicities suggests that for early stage non-small cell lung cancer, no meaningful comparison could be made between stereotactic body RT and stereotactic body PT due to low accrual (NCT01511081). In addition, for locally advanced non-small cell lung cancer, a comparison of intensity modulated RT with passive scattering PT (now largely replaced by spot-scanned intensity modulated PT), PT did not provide any benefit in normal tissue toxicity or locoregional failure over photon therapy. Finally, for locally advanced esophageal cancer, proton beam therapy provided a lower total toxicity burden but did not improve progression-free survival and quality of life (NCT01512589). The purpose of this review is to inform the limitations of current trials looking at protons and photons, considering that advances in technology, physics, and biology are a continuum, and to advocate for future trials geared toward accurate precision RT that need to be viewed as an iterative process in a defined path toward delivering optimal radiation treatment. A foundational understanding of the radiobiologic differences between protons and photons in tumor and normal tissue responses is fundamental to, and necessary for, determining the suitability of a given type of biologically optimized RT to a patient or cohort.
Boron carbide B x C (x = 1/6 – 10) powders were synthesized through a microwave-assisted carbothermic reduction reaction as a potential clean energy material. Their crystallographic structures and optical properties were characterized. X-ray diffraction and electron diffraction indicated that the synthesized B x C powders were amorphous. Electron energy-loss spectroscopy demonstrated that the composition of boron and carbon was in amorphous materials, and their chemical bonding were disclosed from Raman scattering spectroscopy. Here, UV-vis absorption spectroscopy indicated that the bandgap of the bulks varied from 2.30 eV to 3.90 eV, tuned by the boron/carbon element ratio.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The year 2004 marked the beginning of a new era in the design of metallic materials, as the concept of multiple principal component alloys, commonly known as High-Entropy Alloys (HEAs), was proposed by Cantor and Yeh. The unexpected single-phase microstructure, instead of the expected brittle intermetallic compounds, was attributed to the large entropy of mixing and immediately caught the attention of the scientific community. Today, HEAs are considered important advanced materials and a broad range of alloys using nominally the same design principle have been investigated. Despite that, the CrMnFeCoNi (Cantor) alloy stands out as the most successful HEA due to its outstanding mechanical properties and microstructure. In this scenario, variants of the Cantor alloy, named medium-entropy alloys (MEAs), are gaining significant interest as they display a better industrial potential than both HEAs and traditional alloys. These variants of the Cantor alloy with only three or four main elements result in 15 possible combinations. The microstructure of these alloys is discussed in terms of advanced characterization as well as thermodynamic parameters and computational simulation. Their phase stability is addressed over a wide range of temperatures and strain rates. The mechanical properties, especially the fracture toughness, of the CrFeCoNi and CrCoNi alloys have been reported to be even superior to those of the Cantor alloy and most modern engineering alloys. This is associated with the formation of a continuous sequence of strengthening mechanisms, including hierarchical twin networks, which serve to prolong the strain hardening. The present article reviews and critically assesses, for the first time, recent advances in these Cantor-derived MEAs.
Not Available
Not Available
Testing thin film composite (TFC) membrane coupons at low stage-cuts (≤5%) in a sweep-gas permeation system is a common practice to obtain mixed-gas separation properties for benchmarking performance and making scale-up decisions. However, even under these idealized conditions, mixed-gas permeance and selectivity can be more than 30% lower than their pure-gas values, partially due to concentration polarization, an effect that typically intensifies with increased membrane permeance. This study investigates the effect of cell design on mixed-gas testing using PolyActive TM TFC membranes with pure-gas CO 2 permeance of 1700 – 3100 gas permeance unit (GPU), covering the permeance range of most state-of-the-art CO 2 /N 2 separation membranes. Here, we designed and 3D-printed a counter-current permeation cell with enhanced feed and sweep flow efficiency, resulting in a 33 – 41% increase in mixed-gas CO 2 permeance compared to traditional permeation cells. Furthermore, we compared sweep-gas and vacuum permeation methods using traditional permeation cells, revealing that the latter delivers 41% higher mixed-gas CO 2 permeance, because vacuuming effectively minimizes the downstream concentration polarization. These findings highlight the importance of cell design and permeation apparatus selection in lab-scale mixed-gas testing, with strong implications for module design and process optimization at the industrial scale.
Not Available
Not provided.
Not Available
Not Available