Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaGe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Easily-wired toggle switch

Crimp-type connectors reduce assembly and disassembly time. With design, no switch preparation is necessary and socket contracts are crimped to wires inserted in module attached to back of toggle switch engaging pins inside module to make electrical connections. Wires are easily removed with standard detachment tool. Design can accommodate wires of any gage and as many terminals can be placed on switch as wire gage and switch dimensions will allow.

Dean, W. T.↗

Selected developments in laser wire stripping

The operation of mechanical and thermal strippers and the early development of laser wire strippers are reviewed. NASA sponsored development of laser wire stripping for space shuttle includes bench-type strippers as well as an advanced portable hand-held stripper which incorporates a miniaturized carbon dioxide laser and a rotating optics unit with a gas-jet assist and debris exhaust. Drives and controls girdle the wire and slit the remaining slug without manual assistance. This unit can strip wire sizes 26 through 12 gage. A larger-capacity hand-held unit for wire sizes through 1/0 gage was built using a neodynium-doped yttrium aluminum garnet (Nd:YAG) laser. The hand-held units have a flexible umbilical cable to an accompanying cart that carries the power supply, gas supply, cooling unit, and the controls.

Source record↗

High-energy-density cylindrical capacitors

Manufacturing technique produces high quality metalized-film cylindrical capacitors of energy density greater than 0.1 J/g uncased, using either 24-gage polyvinylidene flouride or 14-gage polycarbonate film. Components are wound wrinkle-free on hollow PTFE cores, using winding machine that applies constant dynamically controlled tension to film during winding operation.

Parker, R. D.↗

Models for extracting vertical crustal movements from leveling data

Various adjustment strategies are being used in North America to obtain vertical crustal movements from repeated leveling. The more successful models utilize polynomials or multiquadric analysis to describe elevation change with a velocity surface. Other features permit determination of nonlinear motions, motions associated with earthquakes or episodes, and vertical motions of blocks where boundaries are prespecified. The preferred models for estimating crustal motions permit the use of detached segments of releveling to govern the shape of a velocity surface and allow for input from nonleveling sources such as tide gages and paired lake gages. Some models for extracting vertical crustal movements from releveling data are also excellent for adjusting leveling networks, and permit mixing old and new data in areas exhibiting vertical motion. The new adjustment techniques are more general than older static models and will undoubtedly be used routinely in the future as the constitution of level networks becomes mainly relevelings.

Holdahl, S. H.↗

Space shuttle plume/simulation application

An analysis of pressure and strain-gage data from space shuttle wind tunnel test IA119 and IA138 was performed to define the influence on aerodynamic characteristics resulting from the main propulsion system and solid rocket booster plumes. Aerodynamic characteristics of each of the elements, the components and total vehicle of the space shuttle vehicle during ascent flight was considered. Pressure data were obtained over the aft portions of the space shuttle wind tunnel model in addition to wing and elevon gage data.

Boyle, W.↗

Graphite/polyimide tension tests at elevated and cryogenic temperatures

Interim results for characterizing tension properties of graphite/polyimide laminates are reported. Existing test procedures for resin-matrix composites were evaluated for use through the extreme temperature range indicated above. Of particular concern was the performance of resistance strain gages at the elevated temperatures and tests were carried out to compare their performance against that of a capacitive strain gage. Limited design data are reported for graphite/polyimide laminates which are being produced through the CASTS Project.

Chapman, A. J.↗

Testing of fiber composites at high strain rates

An experimental investigation was conducted to determine strain rate effects in fiber composites. Unidirectional composite specimens of boron/epoxy, graphite/epoxy, S-glass/epoxy and Kevlar/epoxy were tested at tensile strain rates of up to 27 m/m/sec. Longitudinal, transverse and in-plane shear properties, including modulus, Poisson's ratio, strength and ultimate strain, were determined by testing 0-, 90and 10-degree unidirectional coupons. Strains were measured by means of strain gages bonded on the coupons and loads were measured by means of a strain gage load cell. All specimens were loaded in an electrohydraulic loading system. The 0-degree properties which are governed by the fibers do not vary much with strain rate except for the Kevlar/epoxy material which shows an increase in both modulus and strength. The strain rate effects on 90-degree properties were small with a general trend toward higher strength with increasing strain rate. The most noticeable effect was on in-plane shear properties with shear strength values at high strain rates approximately fifteen percent higher than static values.

Daniel, I. M.↗

Electronic depth micrometer

Device for measuring depth or thickness reads distance of penetration by small-diameter probe. It was developed specifically to measure thickness of wet (uncured) insulation applied to Space Shuttle structures; thin probes penetrate wet insulation to substrate, and reference surface on gage is then positioned against outer surface of insulation to measure its thickness. Gage is easy to use, even by workers wearing gloves or other protective clothing, and allows remote reading and recording of production data.

Major, R. K.↗

Comparison tests and experimental compliance calibration of the proposed standard round compact plane strain fracture toughness specimen

Standard round specimen fracture test results compared satisfactorily with results from standard rectangular compact specimens machined from the same material. The location of the loading pin holes was found to provide adequate strength in the load bearing region for plane strain fracture toughness testing. Excellent agreement was found between the stress intensity coefficient values obtained from compliance measurements and the analytic solution proposed for inclusion in the standard test method. Load displacement measurements were made using long armed displacement gages and hollow loading cylinders. Gage points registered on the loading hole surfaces through small holes in the walls of the loading cylinders.

Fisher, D. M.↗

Thermal cycling graphite-polyimide

The effects of repetitive thermal cycling on the temperature-thermal deformation relation of graphite-polyimide were determined. The bending and axial strains, measured with strain gages, of unsymmetric 0 deg sub 2/90 deg sub 2 and 0 deg sub 4/90 deg sub 4 laminates were used as an indication of thermal deformation. The strains were measured as a function of temperature and two temperature ranges were used, room temperature to 180 C and room temperature to 315 C. Five cycles were run in each temperature range and the cycling was done in quasistatic fashion. The response of a flat 0 deg sub 8 laminate was measured as were the effects of repetitive cycling on the strain gages themselves. A piece-wise linear theory, based on classical lamination theory and using the variation of mechanical and thermal expansion properties with temperature, was compared with the experimental results. The correlation between theoretical predictions and experimental results for the thinner laminate was poor.

Hyer, M. W.↗

Thermal expansion of composites using Moire interferometry

An experimental technique for precise measurement of the thermal response of fiber-reinforced composite materials uses moire interferometry with fringe multiplication which yield a sensitivity of 833 nm (32.8 mu in.) per fringe. Results from the technique are compared with those obtained from electrical resistance strain gages, and also those predicted from classical lamination theory. Temperature dependent coefficients of thermal expansion for composite materials subjected to thermal cycling in the temperature range of 297 K (75 F) to 422 K (300 F) were determined for four laminate configurations (0, 90, 0/ + or - 45/90 sub s and 0/90/ + or - 45 sub s) of T300/5208 graphite epoxy, and ranged from -0.107 mu epsilon K/1 (-0.059 mu epsilon deg F/-) for the 0 laminate to 32.18 mu epsilon K/1 (17.88 mu epsilon F/1) for the 90 laminate. Moisture was found to greatly influence the thermal response of a quasi-isotropic laminate, resulting in hysteresis and residual compressive strain as the moisture content was reduced. Comparisons between moire and strain gage measurements were inconclusive with both techniques giving consistent but systematically different results. Differences of as much as 29% were observed.

Bowles, D. E.↗

Moving-Surface Follower Aids Microsurgery

Novel manipulator follows movements of arteries and muscles, enabling precise placement of probe or other microsurgical tool in moving tissue. Microprobe assembly is mounted on output of pneumatic servo of commercial noncontracting thickness gage. Pulsations of tissue surface to be penetrated by probe are sensed by gage and followed by servo, eliminating relative motion between tissue and probe.

Feldstein, C.↗

An Automated Technique for Estimating Daily Precipitation over the State of Virginia

Digital IR and visible imagery obtained from a geostationary satellite located over the equator at 75 deg west latitude were provided by NASA and used to obtain a linear relationship between cloud top temperature and hourly precipitation. Two computer programs written in FORTRAN were used. The first program computes the satellite estimate field from the hourly digital IR imagery. The second program computes the final estimate for the entire state area by comparing five preliminary estimates of 24 hour precipitation with control raingage readings and determining which of the five methods gives the best estimate for the day. The final estimate is then produced by incorporating control gage readings into the winning method. In presenting reliable precipitation estimates for every cell in Virginia in near real time on a daily on going basis, the techniques require on the order of 125 to 150 daily gage readings by dependable, highly motivated observers distributed as uniformly as feasible across the state.

Follansbee, W. A.↗

AgRISTARS: Agriculture and Resources Inventory Surveys Through Aerospace Remote Sensing. Enumerator's manual, 1981 ground data survey

General information and administrative instructions are provided for individuals gathering ground truth data to support research and development techniques for estimating crop acreage and production by remote sensing by satellite. Procedures are given for personal safety with regards to organophosphorus insecticides, for conducting interviews for periodic observations, for coding the crops identified and their growth stages, and for selecting sites for placing rain gages. Forms are included for those citizens agreeing to monitor the gages and record the rainfall. Segment selection is also considered.

Source record↗

Measuring Surface-Shear Stress in a Wind Tunnel

Two-wire skin friction gage gives both magnitude and direction of mean and fluctuating stresses. Heated wires lie at surface of gage, measure airflow by cooling effect. Wires perpendicular to each other to measure flow direction as well as magnitude. Used successfully in various turbulent flow fields, including separating three-dimensional boundary layer over cone at high angle of incidence.

Lemos, F.↗

Measuring Coating Thickness

Gage measures coating thickness in holes. Gage for quickly determining coating thickness in holes on printed circuit board also used to size small holes in other applications.

Schaffer, A.↗