Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Passive sampling and analyses of common dissolved fixed gases in groundwater

An in situ passive sampler and gas chromatographic protocol for analysis of the major and several minor fixed gases in groundwater was developed. A gas-tight syringe, mated to a short length of silicone tubing, was equilibrated with dissolved gases in groundwater by immersing in monitoring wells and was used to transport and to inject a 0.5 mL gas sample into a gas chromatograph. Using Ar carrier gas, a HaySep DB porous polymer phase, and sequential thermal conductivity and reductive gas detectors allowed good sensitivity for He, Ne, H2, N2, O2, CO, CH4, CO2, and N2O. Within 4 days of immersion in groundwater, samplers initially filled with either He or air attained the same and constant gas composition at an Oak Ridge, Tennessee, site heavily impacted by uranium, acidity, and nitrate. Between June 2006 and July 2007, 12 permanent groundwater wells were used to test the passive samplers in groundwater contaminated by a group of four closed radioactive wastewater seepage ponds; over a thousand passive gas samples from these wells averaged 56% CO2, 32.4% N2, 2.5% O2, 2.5% N2O, 0.20% CH4, 0.096% H2, and 0.023% CO with an average recovery of 95 14% of the injected gas volume.

54 ENVIRONMENTAL SCIENCES↗

SAS 3 observations of Cygnus X-1 - The intensity dips

In general, the dips are observed to occur near superior conjunctions of the X-ray source, but one pair of 2-minute dips occurs when the X-ray source is closer to the observer than is the supergiant companion. The dips are analyzed spectrally with the aid of seven energy channels in the range 1.2-50 keV. Essentially, there is no change in the spectral index during the dips. Reductions in the count rates are observed at energies exceeding 6 keV for some of the dips, but the dip amplitude is always significantly greater in the 1.2-3 keV band. It is believed that absorption by partially ionized gas may best explain these results, since the observations of Pravdo et al. (1980) rule out absorption by unionized material. Estimates for the intervening gas density, extent, and distance from the X-ray source are presented. Attention is also given to the problems confronting the models for the injection of gas through the line of sight, believed to be inclined by approximately 30 deg from the binary pole.

Remillard, R. A.↗

Method for using a hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. A hydrocyclone is provided with one or more nozzles on the wall of the hydrocyclone. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the hydrocyclone through the one or more nozzles. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through the vortex finder while the vapor-enriched cryogenic liquid is drawn through the apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

42 ENGINEERING↗

Hydrogen rich gas generator

A process and apparatus is described for producing a hydrogen rich gas by injecting air and hydrocarbon fuel at one end of a cylindrically shaped chamber to form a mixture and igniting the mixture to provide hot combustion gases by partial oxidation of the hydrocarbon fuel. The combustion gases move away from the ignition region to another region where water is injected to be turned into steam by the hot combustion gases. The steam which is formed mixes with the hot gases to yield a uniform hot gas whereby a steam reforming reaction with the hydrocarbon fuel takes place to produce a hydrogen rich gas.

Houseman, J.↗

Method for using an air-sparged hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. An air-sparged hydrocyclone is provided with a porous sparger covered by an outer gas plenum. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the cyclone. The carrier gas is injected into the air-sparged hydrocyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through a vortex finder while the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Sensitivity and history match analysis of a carbon dioxide “huff-and-puff” injection test in a horizontal shale gas well in Tennessee

Due to improvements in well development, shale gas production has gained importance recently, especially in the United States. To improve gas production and develop a better understanding of shale reservoirs, researchers are conducting field tests to monitor CO 2 storage and enhanced gas recovery. Reservoir simulations can then utilize these field results for sensitivity studies, uncertainty analysis, history matching, gas production forecasts, and CO 2 storage capacity estimations. One such field test was performed for the Chattanooga Shale formation in Morgan County, Tennessee. Approximately 463 tonnes (510 tons) of CO 2 was successfully injected into a hydraulically fractured horizontal well over a thirteen-day period in March 2014. The injection test was achieved in four steps: pre-injection, injection, soaking, and flowback. In this paper, those steps were modeled with a reservoir simulator to match the historic production and injection rates with gas component compositions and forecast the production for five years. The reservoir fluid was modeled as a multi-component gas, including CH 4 , C 2 H 6 , C 3 H 8 , N 2 , and CO 2 . Langmuir constants, reservoir pressure, and fracture network volume were adjusted to match simulation results with observed production rates and gas composition. Results showed that, under the same reservoir conditions, each gas component behaves differently by way of compositional changes in production. CH4 behaves like N2, while CO 2 behaves like heavier hydrocarbons such as C 2 H 6 and C 3 H 8 . CO 2 plume results showed that, after injection, the produced CO 2 is mostly derived from fractured limestone (i.e., Fort Payne Formation) because the injected CO 2 is not adsorbed in limestone but rather by shale formations.

03 NATURAL GAS↗

Modeling of Immiscible, Two-Phase Flows in a Natural Rock Fracture

One potential method of geologically sequestering carbon dioxide (CO2) is to inject the gas into brine-filled, subsurface formations. Within these low-permeability rocks, fractures exist that can act as natural fluid conduits. Understanding how a less viscous fluid moves when injected into an initially saturated rock fracture is important for the prediction of CO2 transport within fractured rocks. Our study examined experimentally and numerically the motion of immiscible fluids as they were transported through models of a fracture in Berea sandstone. The natural fracture geometry was initially scanned using micro-computerized tomography (CT) at a fine volume-pixel (voxel) resolution by Karpyn et al. [1]. This CT scanned fracture was converted into a numerical mesh for two-phase flow calculations using the finite-volume solver FLUENT® and the volume-of-fluid method. Additionally, a translucent experimental model was constructed using stereolithography. The numerical model was shown to agree well with experiments for the case of a constant rate injection of air into the initially water-saturated fracture. The invading air moved intermittently, quickly invading large-aperture regions of the fracture. Relative permeability curves were developed to describe the fluid motion. These permeability curves can be used in reservoir-scale discrete fracture models for predictions of fluid motion within fractured geological formations. The numerical model was then changed to better mimic the subsurface conditions at which CO2 will move into brine saturated fractures. The different fluid properties of the modeled subsurface fluids were shown to increase the amount of volume the less-viscous invading gas would occupy while traversing the fracture.

54 ENVIRONMENTAL SCIENCES↗

DICE-gas turbine compound reheat combined cycle

Coal-fired Direct Injection Carbon Engine – Gas Turbine (DICE-GT) Compound-Reheat Combined Cycle (CRCC), is a combined cycle power plant comprising a multiplicity of coal-fired reciprocating internal combustion engines (RICE), which is commonly referred to by the acronym DICE (Direct Injection Carbon Engine); a natural gas-fired gas turbine (turbine and combustor); a heat recovery steam generator (HRSG); a steam turbine generator; and an integrally geared and intercooled centrifugal air compressor. Finally, the concept uses coal-water slurry/fluid in the DICE and natural gas (or hydrogen) in the gas turbine for unmatched efficiency (well above 50% net LHV) and modularity (block sizes of 120, 240 and 360 MW) with easy adaptability to carbon capture and sequestration with minimal additional cost, complexity and performance hit.

42 ENGINEERING↗

Measuring Trace Hydrocarbons in Silanes

Technique rapid and uses standard analytical equipment. Silane gas containing traces of hydrocarbons injected into carrier gas of moist nitrogen having about 0.2 percent water vapor. Carrier, water and silane pass through short column packed with powdered sodium hydroxide which combines moisture and silane to form nonvolatile sodium silicate. Carrier gas free of silane but containing nonreactive hydrocarbons, pass to silica-gel column where chromatographic separation takes place. Hydrocarbons measured by FID.

Lesser, L. A.↗

A multicomponent, two-phase-flow model for CO{sub 2} storage and enhanced coalbed-methane recovery

Injection of CO{sub 2} into deep unminable coal seams is an option for geological storage of CO{sub 2} and may enhance the recovery of CH{sub 4} in these systems, making coal reservoirs interesting candidates for sequestration. New analytical solutions are presented for two-phase, three- and four-component flow with volume change on mixing in adsorbing systems. We analyze the simultaneous flow of water and gas containing multiple adsorbing components. The displacement problem is solved by the method of characteristics. Mixtures of N{sub 2}, CH{sub 4}, CO{sub 2}, and H{sub 2}O are used to represent enhanced coalbed-methane (ECBM) recovery processes. The displacement behavior is demonstrated to be strongly dependent on the relative adsorption strength of the gas components. In ternary systems, two types of solutions result. When a gas rich in CO{sub 2} displaces a less strongly adsorbing gas (such as CH{sub 4}), a shock solution is obtained. As the injected gas propagates through the system, CO{sub 2} is removed from the mobile phase by adsorption, while desorbed gas propagates ahead of the CO{sub 2} front. The adsorption of CO{sub 2} reduces the flow velocity of the injected gas, delaying breakthrough and allowing for more CO{sub 2} to be sequestered per volume of CH{sub 4} produced. For injection gases rich in N{sub 2}, a decrease in partial pressure is required to displace the preferentially adsorbed CH{sub 4} and a rarefaction solution results. In quaternary displacements with injection-gas mixtures of CO{sub 2} and N{sub 2}, the relative adsorption strength of the components results in solutions that exhibit features of both the N{sub 2}-rich and CO{sub 2}-rich ternary displacements. Analytical solutions for ECBM recovery processes provide insight into the complex interplay of adsorption, phase behavior, and convection.

01 COAL, LIGNITE, AND PEAT↗

Effect of surface derived hydrocarbon impurities on Ar plasma properties

The authors report on Langmuir probe measurements that show that hydrocarbon surfaces in contact with Ar plasma cause changes of electron energy distribution functions due to the flux of hydrogen and carbon atoms released by the surfaces. The authors compare the impact on plasma properties of hydrocarbon species gasified from an etching hydrocarbon surface with injection of gaseous hydrocarbons into Ar plasma. They find that both kinds of hydrocarbon injections decrease electron density and slightly increase electron temperatures of low pressure Ar plasma. For low percentages of impurities (∼1% impurity in Ar plasma explored here), surface-derived hydrocarbon species and gas phase injected hydrocarbon molecules cause similar changes of plasma properties for the same number of hydrocarbon molecules injected into Ar with a decrease in electron density of ∼4%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma-Bubble Imaging and Spectroscopy (Final Report)

The aim of this research was to capture time- and space-resolved behavior of breakdown initiation and development in water with gas bubbles injected between the electrodes when excited with microsecond voltage pulses. The results were directly compared to our previous results from a PCRF collaboration on the development of an electrical discharge in a gas bubble immersed in liquids with different conductivities when excited by nanosecond voltage pulses. For nanosecond regimes, cavitation seems to play a major role in plasma breakdown for low conductivities and discharge initiates at an electrode. On microsecond timescales, where cavitation does not play a role, it has been hypothesized that breakdown in water occurs first in bubbles on or near the electrodes, pre-existing or formed thermally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Factors influencing helium measurements for detection of control rod failures in BWR

Much effort has been made to minimize the number and consequences of fuel failures at nuclear power plants. The consequences of control rod failures have also gained an increased attention. In this paper we introduce a system for on-line surveillance of control rod integrity which has several advantages comparing to the surveillance methods available today in boiling water reactors (BWRs). This system measures the helium released from failed control rods containing boron carbide (B4C). However, there are a number of factors that might influence measurements, which have to be taken into consideration when evaluating the measured data. These factors can be separated into two groups: 1) local adjustments, made on the sampling line connecting the detector to the off-gas system, and 2) plant operational parameters. The adjustments of the sample line conditions include variation of gas flow rate and gas pressure in the line. Plant operational factors that may influence helium measurements can vary from plant to plant. The factors studied at Leibstadt nuclear power plant (KKL) were helium impurities in injected hydrogen gas, variation of the total off-gas flow and regular water refill. In this paper we discuss these factors and their significance and present experimental results of measurements at KKL. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗