Upregulation of B23 promotes tumor cell proliferation and predicts poor prognosis in glioma

B23 (also known as Nucleophosmin, NPM, numatrin or NO38) is a ubiquitously expressed phosphoprotein belonging to the nucleoplasmin family of chaperones. In this study we intended to investigate the clinical significance of B23 expression in human glioma and its biological function in glioma cells. Western blot and immunohistochemistry analysis showed that B23 was overexpressed in glioma tissues and glioma cell lines. In addition, the expression level of B23 was positively correlated with glioma pathological grade and Ki-67 expression. Kaplan–Meier analysis revealed that a higher B23 expression in patients with glioma was associated with a poorer prognosis. In vitro, after the release of glioma cell lines from serum starvation, the expression of B23 was upregulated, as well as PCNA (Proliferating Cell Nuclear Antigen) and cyclin A. In addition, knockdown of B23 by small interfering RNA transfection diminished the expression of PCNA, cyclin D1 and arrested cell growth at G1 phase. Taken together, our results implied that B23 could be a candidate prognostic biomarker as well as a potential therapeutical target of glioma. - Highlights: • B23 expression increased as the malignant degree of glioma increased, which was consistent with Ki-67 expression. • High expression of B23 could be a strong determinant of poor prognosis in glioma. • B23 may be involved in the proliferation of glioma in a cell-cycle-dependent pathway. • Knockdown of B23 expression by siRNA could affect the progression of glioma. • B23 may be a potential prognosis biomarker and a possible therapeutic target for glioma.

60 APPLIED LIFE SCIENCES↗

Graphite Characterization: Baseline Variability Analysis Report

The Idaho National INL’s Baseline Material Property program provides many measurements of different material properties on a variety of nuclear graphite grades being investigated for irradiation-induced changes in material properties. The baseline material properties provide an unirradiated reference for comparison with measurements of those properties after irradiation. This study describes how uncertainty, or variance, in estimates of important material properties, like compressive strength, may depend on sample size, sample distribution and parameter estimation methods. Compressive strength data from two large collections of specimens from a billet of PCEA graphite (sample size = 230) and a billet of IG-110 graphite (sample size = 48) are used to illustrate these dependencies. The grades of graphite used represent approximate end members in terms of relative variability in strength measurements. Monte Carlo simulation and bootstrapping methods were used to examine variance in Weibull-parameter estimates as a function of sample size. Results were consistent with what previous statistical analyses have shown about the relationship between sample size and width of the confidence interval for maximum likelihood (ML) estimated parameters when samples are repeatedly drawn from a Weibull distribution. As a function of sample size, the precision of the modulus estimate increases faster than that of the characteristic strength. The modulus maximum likelihood estimates (MLEs) are biased for low sample sizes. The American Society for Testing and Materials document ASTM D7846-16 provides equations that describe the dependence of the variance of parameter MLEs on sample size. Using the same methodology, we show that the polynomials provided for variance dependence on sample size are inaccurate for sample sizes greater than ~120. We provide approximations to that relationship that illustrate relative constancy for sample size > ~10, in the logspace relationship of the modulus variance and the log transformed characteristic strength variance. Bootstrapping provided a means of comparing Weibull parameters obtained using ASME’s guidance for specimen collection to those obtained using different weighting in a case where strength is related to position in a billet and to grain orientation and a single distribution is used to characterize the billet. ASME specifies that samples be collected with equal representation in all locations and grain orientations. Parameter values obtained using ASME’s method were different from those obtained using random sampling of the complete data sets, and this was particularly true for the PCEA data. In addition, while the ASME approach yielded more conservative parameters for the PCEA data, the opposite was true for the IG-110 data. The difference observed for the PCEA data set likely reflects the larger number of against-grain specimens collected, which had generally higher strength than the with-grain specimens. This emphasizes the importance of the dependence of strength on location or grain orientation and suggests that it may be prudent to weight specimen collection toward the weaker subgroups if a conservative estimate as desired, as the equal weighting method recommended by ASME would will not always provide the most conservative Weibull parameters. Because spatial correlations commonly exist in certain grades of graphite, future work may involve developing a methodology for parameter inference that relaxes the assumption of independent specimens. ASTM and ASME codes recommend different parameter estimation methods and models of the Weibull distribution in different situations. Descriptions of the effects on parameter estimates for the example billets used in this study provide an example of how the method may affect the parameter estimate, and how—in this case—that compares to differences due to other factors, such as sample size and dependence on grain orientation or sample location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PowerGrid - A Computation Engine for Large-Scale Electric Networks

This Final Report discusses work on an approach for analog emulation of large scale power systems using Analog Behavioral Models (ABMs) and analog devices in PSpice design environment. ABMs are models based on sets of mathematical equations or transfer functions describing the behavior of a circuit element or an analog building block. The ABM concept provides an efficient strategy for feasibility analysis, quick insight of developing top-down design methodology of large systems and model verification prior to full structural design and implementation. Analog emulation in this report uses an electric circuit equivalent of mathematical equations and scaled relationships that describe the states and behavior of a real power system to create its solution trajectory. The speed of analog solutions is as quick as the responses of the circuit itself. Emulation therefore is the representation of desired physical characteristics of a real life object using an electric circuit equivalent. The circuit equivalent has within it, the model of a real system as well as the method of solution. This report presents a methodology of the core computation through development of ABMs for generators, transmission lines and loads. Results of ABMs used for the case of 3, 6, and 14 bus power systems are presented and compared with industrial grade numerical simulators for validation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure of a Myeloid cell leukemia-1 (Mcl-1) inhibitor bound to drug site 3 of Human Serum Albumin

Amplification of the gene encoding Myeloid cell leukemia-1 (Mcl-1) is one of the most common genetic aberrations in human cancer and is associated with high tumor grade and poor survival. Recently, we reported on the discovery of high affinity Mcl-1 inhibitors that elicit mechanism-based cell activity. These inhibitors are lipophilic and contain an acidic functionality which is a common chemical profile for compounds that bind to albumin in plasma. Indeed, these Mcl-1 inhibitors exhibited reduced in vitro cell activity in the presence of serum. Here we describe the structure of a lead Mcl-1 inhibitor when bound to Human Serum Albumin (HSA). Unlike many acidic lipophilic compounds that bind to drug site 1 or 2, we found that this Mcl-1 inhibitor binds predominantly to drug site 3. Site 3 of HSA may be able to accommodate larger, more rigid compounds that do not fit into the smaller drug site 1 or 2. In conclusion, structural studies of molecules that bind to this third site may provide insight into how some higher molecular weight compounds bind to albumin and could be used to aid in the design of compounds with reduced albumin binding.

59 BASIC BIOLOGICAL SCIENCES↗

External Beam Radiotherapy for Prostate Cancer: Urinary Outcomes for Men With High International Prostate Symptom Scores (IPSS)

Purpose: To report the urinary outcome of men treated for prostate cancer with external beam radiotherapy (EBRT) who have pretreatment obstructive urinary symptoms (International Prostate Symptom Score [IPSS] {>=}15). Methods and Materials: We treated 368 patients with EBRT for localized prostate cancer, and pre- and post-radiotherapy (RT) IPSSs were recorded. In total, 80 men had an IPSS {>=}15, 48% of whom were taking genitourinary (GU) medications before RT. The IPSS was followed over time and analyzed as a pretreatment factor against Radiation Therapy Oncology Group acute and late GU toxicity. Results: The median follow-up was 44 months. Among men with a pre-RT IPSS {>=}15, the median IPSS at baseline, first follow-up, and last follow-up was 18 (range, 15 to 34), 17 (range, 0 to 32), and 13 (range, 0 to 34), respectively. The mean patient declines in IPSS from baseline to first and last follow-up were -3.6 points (p < 0.0004) and -6.9 points (p < 0.0001), respectively. At last follow-up, 43 men (54%) took GU medications. Pre-RT IPSS {>=}15 vs. {<=}14 was associated with a higher incidence of Grade {>=}2 acute GU toxicity (64% vs. 42%, p = 0.0005), and 4-year freedom from Grade {>=}2 late GU toxicity was 38% vs. 64% (p < 0.0001). There was no greatly increased risk of Grade {>=}3 late GU toxicity for men with IPSS {>=}15 (4-year freedom from Grade {>=}3 late GU toxicity of 90% vs. 96%, p = 0.0964). Conclusions: Although the improvement is not immediate, men with moderate to severe obstructive GU symptoms can have improvement in urinary function after EBRT, without significant risk for severe morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Survival and Toxicity in Patients Treated With High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer

Purpose: To report long-term survival and toxicity outcomes with the use of high-dose intensity modulated radiation therapy (IMRT) to 86.4 Gy for patients with localized prostate cancer. Methods and Materials: Between August 1997 and December 2008, 1002 patients were treated to a dose of 86.4 Gy using a 5-7 field IMRT technique. Patients were stratified by prognostic risk group based on National Comprehensive Cancer Network risk classification criteria. A total of 587 patients (59%) were treated with neoadjuvant and concurrent androgen deprivation therapy. The median follow-up for the entire cohort was 5.5 years (range, 1-14 years). Results: For low-, intermediate-, and high-risk groups, 7-year biochemical relapse-free survival outcomes were 98.8%, 85.6%, and 67.9%, respectively (P<.001), and distant metastasis-free survival rates were 99.4%, 94.1%, and 82.0% (P<.001), respectively. On multivariate analysis, T stage (P<.001), Gleason score (P<.001), and >50% of initial biopsy positive core (P=.001) were predictive for distant mestastases. No prostate cancer-related deaths were observed in the low-risk group. The 7-year prostate cancer-specific mortality (PCSM) rates, using competing risk analysis for intermediate- and high-risk groups, were 3.3% and 8.1%, respectively (P=.008). On multivariate analysis, Gleason score (P=.004), percentage of biopsy core positivity (P=.003), and T-stage (P=.033) were predictive for PCSM. Actuarial 7-year grade 2 or higher late gastrointestinal and genitourinary toxicities were 4.4% and 21.1%, respectively. Late grade 3 gastrointestinal and genitourinary toxicity was experienced by 7 patients (0.7%) and 22 patients (2.2%), respectively. Of the 427 men with full potency at baseline, 317 men (74%) retained sexual function at time of last follow-up. Conclusions: This study represents the largest cohort of patients treated with high-dose radiation to 86.4 Gy, using IMRT for localized prostate cancer, with the longest follow-up to date. Our findings indicate that this treatment results in excellent clinical outcomes with acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modifying the strength and strain concentration profile within collagen scaffolds using customizable arrays of poly-lactic acid fibers

Here, the tendon-to-bone junction is a highly specialized tissue which dissipates stress concentrations between mechanically dissimilar tendon and bone. Upon injury, the local heterogeneities across this insertion are not regenerated, leading to poor functional outcomes such as formation of scar tissue at the insertion and re-failure rates exceeding 90%. Although current tissue engineering methods are moving towards the development of spatially-graded biomaterials to begin to address these injuries, significant opportunities remain to engineer the often complex local mechanical behavior of such biomaterials to enhance their bioactivity. Here, we describe the use of three-dimensional printing techniques to create customizable arrays of poly-lactic acid (PLA) fibers that can be incorporated into a collagen scaffold under development for tendon bone junction repair. Notably, we use additive manufacturing concepts to generate arrays of spatially-graded fibers from biodegradable PLA that are incorporated into collagen scaffolds to create a collagen-PLA composite. We demonstrate the ability to tune the mechanical performance of the fiber-scaffold composite at the bulk scale. We also demonstrate the incorporation of spatially-heterogeneous fiber designs to establish non-uniform local mechanical performance of the composite biomaterial under tensile load, a critical element in the design of multi-compartment biomaterials for tendon-to-bone regeneration applications. Together, this work highlights the capacity to use multi-scale composite biomaterials to control local and bulk mechanical properties, and provides key insights into design elements under consideration for mechanically competent, multi-tissue regeneration platforms.

3D printing↗

Hoop Tensile Failure Stress of 500 µm-Diameter Ceramic Spheres

The tensile failure stress of a brittle-material sphere is important to the survival of the sphere itself but is particularly relevant to systems that employ such spheres for applications in which the sphere exterior is subjected to tension during system fabrication or operation. That maximum hoop or tangential stress can be measured by diametrally compressing a C-sphere specimen directly machined from such spheres. This combination of specimen geometry and test method was conceived at Oak Ridge National Laboratory around 20 years ago. Although the C-sphere geometry has been tested with larger spheres, the ease and efficacy of its testing are unknown for submillimeter sphere diameters. To consider this, C-sphere specimens were machined from yttria-stabilized zirconia (YSZ) spheres of ∼500 µm diameter. The maximum (hoop or tangential) tensile stress was determined as a function of compressive failure force and specimen dimensions using finite element analysis. Companion effective area and volume as a function of Weibull modulus were computed. Hoop tensile failure stresses were then measured and fractography conducted to examine flaw type and location and to estimate the mirror constant of this YSZ grade. This novel study demonstrates that hoop tensile failure stress can be determined with sub-millimeter brittle-material spheres.

Delia, Daniel [ORNL] (ORCID:0000000209023239)↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

Development and evaluation of a method of calibrating medical displays based on fixed adaptation

Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.

60 APPLIED LIFE SCIENCES↗

CPT2 downregulation triggers stemness and oxaliplatin resistance in colorectal cancer via activating the ROS/Wnt/β-catenin-induced glycolytic metabolism

Highlights: • CPT2 was downregulated in CRC. • CPT2 suppressed the proliferation and glycolytic metabolism in CRC cells. • CPT2 inhibited cancer stem cell properties and oxaliplatin resistance in CRC. • CPT2 attenuated CRC tumor growth and enhanced oxaliplatin sensitivity in vivo. • CPT2 functioned via suppressing ROS/Wnt/β-catenin pathway in CRC. Carnitine palmitoyltransferase 2 (CPT2) has been demonstrated to act as a tumor promotor or suppressor in different types of cancers. However, little is known about the effect of CPT2 on colorectal cancer (CRC). In the present study, we analyzed CPT2 expression in CRC tissues and cells. CPT2 was overexpressed in CRC cell lines (SW480 and RKO), and its effects and molecular mechanism on the proliferation, glycolysis, stemness, and oxaliplatin sensitivity were investigated. The xenograft experiment was used to confirm the influence of CPT2 on CRC tumorigenesis in vivo. We found that CPT2 expression was significantly downregulated in CRC patients, and its lower expression was associated with the poor prognosis, large tumor size, advanced TNM stage, and poor histological grade differentiation of patients. Upregulation of CPT2 significantly inhibited the proliferation, glycolytic metabolism, cancer stem cell properties, and oxaliplatin resistance in CRC cells. Also, the increase of CPT2 inhibited tumorigenesis, stemness and glycolysis, while enhanced oxaliplatin sensitivity in mouse models. Mechanistically, CPT2 functioned via suppressing the activation of Wnt/β-catenin pathway through repressing ROS production. In conclusion, our results demonstrated that CPT2 was decreased in CRC, and CPT2 downregulation could trigger stemness and oxaliplatin resistance in CRC via activating the ROS/Wnt/β-catenin-induced glycolytic metabolism. This study indicates that CPT2 is a potential therapeutic target for CRC.

60 APPLIED LIFE SCIENCES↗

Long-Term Results of Conformal Radiotherapy for Progressive Airway Amyloidosis

Purpose: To evaluate the efficacy of conformal external beam radiotherapy (RT) for local control of progressive airway amyloidosis. Methods and Materials: We conducted a retrospective review of patients with biopsy-proven progressive airway amyloidosis treated with conformal RT between 2000 and 2006 at Boston Medical Center. The patients were evaluated for performance status and pulmonary function, with computed tomography and endoscopy after RT compared with the pretreatment studies. Local control was defined as the lack of progression of airway wall thickening on computed tomography imaging and stable endobronchial deposits by endoscopy. Results: A total of 10 symptomatic airway amyloidosis patients (3 laryngeal and 7 tracheobronchial) received RT to a median total dose of 20 Gy in 10 fractions within 2 weeks. At a median follow-up of 6.7 years (range, 1.5-10.3), 8 of the 10 patients had local control. The remaining 2 patients underwent repeat RT 6 and 8.4 months after initial RT, 1 for persistent bronchial obstruction and 1 for progression of subglottic amyloid disease with subsequent disease control. The Eastern Cooperative Oncology Group performance status improved at a median of 18 months after RT compared with the baseline values, from a median score of 2 to a median of 1 (p = .035). Airflow (forced expiratory volume in 1 second) measurements increased compared with the baseline values at each follow-up evaluation, reaching a 10.7% increase (p = .087) at the last testing (median duration, 64.8 months). Acute toxicity was limited to Grade 1-2 esophagitis, occurring in 40% of patients. No late toxicity was observed. Conclusions: RT prevented progressive amyloid deposition in 8 of 10 patients, resulting in a marginally increased forced expiratory volume in 1 second, and improved functional capacity, without late morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of sucrose and granulated cane sugar in the therapeutic dose range

Granulated cane sugar has been used as a dosimetric material to report dose in high dose accidental irradiations. The purpose of this study was to assess whether clinical dosimetry is also plausible with such a commonly available material. The behavior of cane sugar was explored with respect to therapeutically relevant radiation quantities (dose, dose rate) and qualities (energy, radiation type) as well as under different temperature conditions. The stability of the signal postirradiation was also measured. Absorbed dose was measured by spectrophotometric readout of a ferrous ammonium sulfate xylenol orange (FX)-sugar solution in 10 cm path length cells. A visible color change was produced as a function of dose when the irradiated sugar samples were dissolved in FX solution (10% dilution by mass). A comparison of the optical absorbance spectra and dose response of cane sugar with analytical grade sucrose was done to establish a benchmark standard from which subsequent dosimetry measurements can be validated. The response of the sugar dosimeter read at 590 nm was found to be linear over the dose range of 100-2000 cGy, independent of energy (6-18 MV) and of the average dose rate (100-500 cGy/min). The readout of sugar samples irradiated with mixed photon and electron fields was also shown to be independent of radiation type (photons and electrons). Sugar temperature (20-40 degree sign C) during irradiation did not affect dose estimates, making it a promising dosimeter for in vivo dosimetry, particularly in cases where the dosimeter must remain in contact with the patient for an extended period of time. Sugar can be used as an integrating dosimeter, since it exhibits no fractionation effects. Granulated cane sugar is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noninvasive and Curative Radiation Therapy for Sebaceous Carcinoma of the Eyelid

Purpose: Sebaceous carcinoma of the eyelid is a rare malignancy. Surgical excision remains the standard and most reliable curative treatment. However, surgery is sometimes not possible because many patients are elderly, and it frequently causes functional and cosmetic impairment of the eyelid. We therefore carried out a study to determine the role of radiation therapy in relation to sebaceous carcinoma of the eyelid. Methods and Materials: Thirteen patients with sebaceous carcinoma of the eyelid underwent radiation therapy with curative intent. There were 6 men and 7 women, and their ages at irradiation ranged from 60 to 85 years (median, 78 years). Only 1 patient had cervical lymph node metastasis, and none of the patients had distant metastasis. A total dose of 50 to 66.6 Gy (median, 60 Gy) was delivered to tumor sites in 22 to 37 fractions. Results: All irradiated tumors were controlled at a median follow-up period of 55 months. Only 1 patient had recurrence of cervical lymph node metastasis outside the radiation field, at 22 months after irradiation. The 5-year local progression-free and disease-free rates were 100% and 89%, respectively. The overall and disease-free survival rates at 5 years were 100% and 89%, respectively. Although acute and transient therapy-related reactions of Grade 2 or less were observed, there were no severe toxicities of Grade 3 or greater. Conclusions: Radiation therapy is a safe and effective treatment for patients with sebaceous carcinoma of the eyelid. It appears to contribute to prolonged survival as a result of good tumor control, and it also facilitates functional and cosmetic preservation of the eyelid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-Ray Diffraction of Slag-Based Sodium Salt Waste Forms - 15513

Cementitious materials are used to solidify and stabilize aqueous based radioactive waste containing sodium salts. The types and proportions of cementitious ingredients used to treat aqueous radioactive waste streams containing sodium salts depend on the performance objectives for the waste forms and the compositions of the waste streams. This paper documents sample preparation and x-ray diffraction results for a series of materials made with water or highly alkaline sodium salt simulated waste water and cementitious binders. The objective of this study was to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available. Characterization of the mineralogy is also important for understanding the buffering effects that the waste form has on infiltrating water / leachates. In summary, mixtures of Type II portland cement, Grade 100 ground granulated blast furnace slag (GGBFS) and carbon burn-out (CBO) Class F Fly ash which were hydrated with water contained hydrated phase assemblages typical of those reported in the literature. The calcium silicate hydrate phase assemblage in samples hydrated with the alkaline 4.4 M sodium salt simulated waste solution was found to be a function of the (CaO + MgO) / (SiO{sub 2} + Al{sub 2}O{sub 3}) ratio of the samples characterized. No significant differences were detected in samples cured 2 months and 14 months in sealed containers at ambient indoor temperatures. Slag and a blend of slag and cement hydrated with caustic 4.4 M Na salt solution resulted in the most crystalline matrix. In addition to poorly ordered C-S-H, these samples contained fairly well ordered C-S-H I (a precursor of 14A tobermorite) and 11 A Al-substituted tobermorite. These crystalline C-S-H phases did not form or were present in only trace amounts in slag blends containing about 45 to 62 mass percent fly ash. These slag-Class F fly ash blends had a higher silica plus alumina content relative to lime and magnesia than the blends that produced C-S-H I and Al-substituted tobermorite. The calcium silicate binder in the 10:45:45 mixture of cement: slag: fly ash was made up of poorly ordered C-S-H. The sample cured for 14 months may contain a small amount of the more crystalline calcium silicate hydrate phases. Layered double hydroxides in the hydrotalcite (magnesium-aluminum carbonate hydroxide) and hydrocalumite / AFm phases (calcium aluminum hydroxide) were present in mixtures containing slag. The specific phase(s) were not identified because these phases form solid solutions and have a considerable amount of overlap in their x-ray patterns. Sodium nitrate was the only sodium salt phase identified in x-ray diffraction patterns of the samples hydrated with salt solution. Drying during x-ray diffraction sample preparation may have resulted in precipitation of the sodium nitrate or it may have been present in the samples prior to x-ray sample preparation. Sodium sulfate, aluminate, and carbonate may have been incorporated in the structures of the layered double hydroxide (AFm) type phases. These mixed metal layered double hydroxides make up an important fraction of the matrix in the slag containing blends hydrated with caustic salt solution. They are among the few oxide-based phases that exhibit substantial, permanent anion exchange capacity [Kirkpatrick, et al. 1999, Plamer, et al., 2009, and Zhang and Reardon, 2003]. They also contribute to the structural properties of cementitious matrices [Taylor, 1997]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SQMBox: Interfacing a semiempirical integral library to modular ab initio electronic structure enables new semiempirical methods

Ab initio and semiempirical electronic structure methods are usually implemented in separate software packages or use entirely different code paths. As a result, it can be time-consuming to transfer an established ab initio electronic structure scheme to a semiempirical Hamiltonian. Here we present an approach to unify ab initio and semiempirical electronic structure code paths based on a separation of the wavefunction ansatz and the needed matrix representations of operators. With this separation, the Hamiltonian can refer to either an ab initio or semiempirical treatment of the resulting integrals. We built a semiempirical integral library and interfaced it to the GPU-accelerated electronic structure code TeraChem. Equivalency between ab initio and semiempirical tight-binding Hamiltonian terms is assigned according to their dependence on the one-electron density matrix. The new library provides semiempirical equivalents of the Hamiltonian matrix and gradient intermediates, corresponding to those provided by the ab initio integral library. This enables the straightforward combination of semiempirical Hamiltonians with the full pre-existing ground and excited state functionality of the ab initio electronic structure code. We demonstrate the capability of this approach by combining the extended tight-binding method GFN1-xTB with both spin-restricted ensemble-referenced Kohn–Sham and complete active space methods. We also present a highly efficient GPU implementation of the semiempirical Mulliken-approximated Fock exchange. The additional computational cost for this term becomes negligible even on consumer-grade GPUs, enabling Mulliken-approximated exchange in tight-binding methods for essentially no additional cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on the dynamic recrystallization model and mechanism of nuclear grade 316LN austenitic stainless steel

In this study, the dynamic recrystallization behaviors of a nuclear grade 316LN austenitic stainless steel were researched through hot compression experiment performed on a Gleeble-1500 simulator at temperatures of 900–1250 °C and strain rates of 0.01–1 s{sup −1}. By multiple linear regressions of the flow stress-strain data, the dynamic recrystallization mathematical models of this steel as functions of strain rate, strain and temperature were developed. Then these models were verified in a real experiment. Furthermore, the dynamic recrystallization mechanism of the steel was determined. The results indicated that the subgrains in this steel are formed through dislocations polygonization and then grow up through subgrain boundaries migration towards high density dislocation areas and subgrain coalescence mechanism. Dynamic recrystallization nucleation performs in grain boundary bulging mechanism and subgrain growth mechanism. The nuclei grow up through high angle grain boundaries migration. - Highlights: •Establish the DRX mathematical models of nuclear grade 316LN stainless steel •Determine the DRX mechanism of this steel •Subgrains are formed through dislocations polygonization. •Subgrains grow up through subgrain boundaries migration and coalescence mechanism. •DRX nucleation performs in grain boundary bulging mechanism and subgrain growth mechanism.

36 MATERIALS SCIENCE↗

Investigation of the hydrochlorination of SiCl4

A basic, experimental study on the hydrochlorination of silicon tetrachloride and metallurgical grade silicon with hydrogen gas to form trichlorosilane was carried out to greatly expand the range of reaction conditions. The equilibrium constant, K sub p, for the hydrochlorination reaction was measured as a function of temperature, pressure and concentration. The variation of the equilibrium constant as a function of temperature provided the measurement on the heat of reaction, delta H, by the Second Law Method. The value of delta H was measured to give 10.6 Kcal/mole. The equilibrium constant was also studied as a function of concentration. In agreement with the theory, the equilibrium constant remained constant with respect to the varying H2/SiCl4 feed ratios. On the other hand, the effect of pressure on the equilibrium constant was found to be more complex.

Mui, J. Y. P.↗