Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Characterization of the Los Alamos IPG YLR-6000 fiber laser using multiple optical paths and laser focusing optics

Fiber laser technology has been identified as the replacement power source for the existing Los Alamos TA-55 production laser welding system. An IPG YLR-6000 fiber laser was purchased, installed at SM-66 R3, and accepted in February 2008. No characterization of the laser and no welding was performed in the Feb 2008 to May 2009 interval. T. Lienert and J. Bernal (Ref. 1, July 2009) determined the existing 200 mm Rofin collimator and focus heads used with the Rofin diode pumped lasers were inadequate for use with the IPG laser due to clipping of the IPG laser beam. Further efforts in testing of the IPG laser with Optoskand fiber delivery optics and a Rofin 120 mm collimator proved problematic due to optical fiber damage. As a result, IPG design optical fibers were purchased as replacements for subsequent testing. Within the same interval, an IPG fiber-to-fiber (F2F) connector, custom built for LANL, (J. Milewski, S. Gravener, Ref.2) was demonstrated and accepted at IPG Oxford, MA in August 2009. An IPG service person was contracted to come to LANL to assist in the installation, training, troubleshooting and characterization of the multiple beam paths and help perform laser head optics characterization. The statement of work is provided below: In summary the laser system, optical fibers, F2F connector, Precitec head, and a modified Rofin type (w/120mm Optoskand collimator) IWindowIBoot system focus head (Figure 1) were shown to perform well at powers up to 6 kW CW. Power measurements, laser spot size measurements, and other characterization data and lessons learned are contained within this report. In addition, a number of issues were identified that will require future resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Directions in Focused Ion Beam Induced Deposition for the Nanoprinting of Functional 3D Heterostructures

The focused ion beam (FIB) microscope is well established as a high-resolution machining instrument capable of site-selectively removing material down to the nanoscale. Beyond subtractive processing, however, the FIB can also add material via a technique known as focused ion beam induced deposition (FIBID). Using FIBID, the FIB can thus be employed for the direct-write of complex nanostructures. This work explores new directions in three-dimensional FIBID nanoprinting, harnessing unique features of helium and neon FIBs. In particular, the superior spatial resolution of these novel FIBs is leveraged to fabricate precise multimaterial architectures, an isotope effect is used to create satellite deposits, and dose-controlled implantation of the gaseous ions is used to engineer internal voids. In the context of voids, the fabrication of hollow nanopillars by helium-FIBID due to concurrent milling (as shown previously by others) is revisited. Insight into the chemical and structural composition of the nanostructures is obtained using advanced electron microscopy, accurately revealing buried interfaces, crystallite distributions, chemical compositions, and material transformations. Next-generation devices and technologies that could be enabled by the novel heterostructures demonstrated here are discussed, setting the stage for the potential evolution of FIBID into a versatile platform for functional nanomaterials design and fabrication.

FIBID↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

Material Changes in Electrocatalysis: An In Situ/Operando Focus on the Dynamics of Cobalt‐Based Oxygen Reduction and Evolution Catalysts

Abstract The shift towards cheaper, non‐platinum group metal electrocatalyst materials for clean energy technologies is coupled with challenges in maintaining long‐term performance. For practical purposes, electrocatalytic stability typically focuses on catalyst electrochemical performance over time. However, a deeper understanding of catalyst material property changes during operation is needed to enable material‐specific design strategies for long‐term stabilization. In the last several decades, improvements in material characterization techniques have made it possible to probe the composition, structure, and degradation products of catalysts in situ/operando. Herein we review the current understanding of in situ/operando material stability of Co‐based electrocatalysts for the oxygen evolution (OER) and reduction reactions (ORR) in acidic and alkaline environments. We focus on in situ/operando materials characterization of three categories of Co‐based OER/ORR catalysts: oxides and (oxy)hydroxides, mixed‐metal catalysts, and non‐oxide materials. This review aims to compile and compare the results from multiple studies and techniques to provide insight into the role that the starting material, pH, and applied potential have on the active surface and stability of Co‐based materials. We conclude by highlighting directions that have been underexplored with opportunities for continued research including improving in situ/operando characterization, methods to probe long‐term material changes, and the development of operando studies on full‐scale devices. Using Co‐based materials as a case study, this review shows the vital role that in situ/operando characterization must play in the future of improving electrocatalyst stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using the Human Systems Simulation Laboratory at Idaho National Laboratory for Safety Focused Research

Under the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program, researchers at Idaho National Laboratory (INL) have been using the Human Systems Simulation Laboratory (HSSL) to conduct critical safety focused Human Factors research and development (R&D) for the nuclear industry. The LWRS program has the overall objective to develop the scientific basis to extend existing nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure their long-term reliability, productivity, safety, and security. One focus area for LWRS is the NPP main control room (MCR), because many of the instrumentation and control (I&C) system technologies installed in the MCR, while highly reliable and safe, are now difficult to replace and are therefore limiting the operating life of the NPP. This paper describes how INL researchers use the HSSL to conduct Human Factors R&D on modernizing or upgrading these I&C systems in a step-wise manner, and how the HSSL has addressed a significant gap in how to upgrade systems and technologies that are built to last, and therefore require careful integration of analog and new advanced digital technologies.

99 GENERAL AND MISCELLANEOUS↗

Kinematic focus point method for particle mass measurements in missing energy events

We investigate the solvability of the event kinematics in missing energy events at hadron colliders, as a function of the particle mass ansatz. To be specific, we reconstruct the neutrino momenta in dilepton tt¯-like events, without assuming any prior knowledge of the mass spectrum. We identify a class of events, which we call extreme events, with the property that the kinematic boundary of their allowed region in mass parameter space passes through the true mass point. We develop techniques for recognizing extreme events in the data and demonstrate that they are abundant in a realistic data sample, due to expected singularities in phase space. We propose a new method for mass measurement whereby we obtain the true values of the mass parameters as the focus point of the kinematic boundaries for all events in the data sample. Since the masses are determined from a relatively sharp peak structure (the density of kinematic boundary curves), the method avoids some of the systematic errors associated with other techniques. We show that this new approach is complementary to previously considered methods in the literature where one studies the solvability of the kinematic constraints throughout the mass parameter space. In particular, we identify a problematic direction in mass space of nearly 100% solvability, and then show that the focus point method is effective in lifting the degeneracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

Magnetic resonance imaging-guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Principles of Ion Selection, Alignment, and Focusing in Tandem Ion Mobility Implemented Using Structures for Lossless Ion Manipulations (SLIM)

Tandem ion mobility (IM) enables the characterization of subpopulations of ions from larger ensembles, including differences that cannot be resolved in a single dimension of IM. Tandem IM consists of at least two IM regions that are each separated by an ion selection region. In many implementations of tandem IM, ions eluting from a dimension of separation are filtered and immediately transferred to the subsequent dimension of separation (selection-only experiments). We recently reported a mode of operation in which ions eluting from a dimension are trapped prior to the subsequent dimension (selection-trapping experiments), which was implemented on an instrument constructed using the structures for lossless ion manipulations (SLIM) architecture. Here, we use a combination of experiments and trajectory simulations to characterize aspects of the selection, trapping, and separation processes underlying these modes of operation. For example, the actual temporal profile of filtered ions can be very similar to the width of the waveforms used for selection, but depending on experimental parameters, can differ by up to ± 500 μs. Experiments and simulations indicate that ions in selection-trapping experiments can be spatially focused between dimensions, which removes the broadening that occurred during the preceding dimension. During focusing, individual ions are thermalized, which aligns and establishes common initial conditions for the subsequent dimension. Therefore, selection-trapping experiments appear to offer significant advantages relative to selection-only experiments, which we anticipate will become more pronounced in future experiments that make use of longer IM separations, additional dimensions of analysis, and the outcomes of this study. .

74 ATOMIC AND MOLECULAR PHYSICS↗

An experimental study of ovarian cancer imaging and therapy by paclitaxel-loaded phase-transformation lipid nanoparticles combined with low-intensity focused ultrasound

Highlights: • PTX-anti-LHRHR-PTNPs is expected to become a new type of ultrasound contrast agent. • LIFU can enhance the efficiency of PTX-anti-LHRHR-PTNPs. • For ovarian cancer, PTX-anti-LHRHR-PTNPs has a good therapeutic effect. Drug-loaded phase-transformation lipid nanoparticles (NPs) combined with low-intensity focused ultrasound (LIFU) for ultrasound molecular imaging and therapy, which is a very promising drug carrier and can provide both physical and chemical therapeutics, simultaneously. We successfully prepared the paclitaxel (PTX) loaded anti-LHRHR targeted phase-transformation lipid nanoparticles (PTX-anti-LHRHR-PTNPs) for ovarian cancer in this study combined with LIFU has the following characteristics: On the one hand, it showed smaller size and greater stability than blood cells, which significantly prolonged its half-life in the body, and can actively target ovarian cancer OVCAR-3 cells, and smoothly penetrate the endothelial gap into the tumor site for specifically killing the ovarian cancer cells. Thereby, the special drug carrier improved the therapeutic effect and reduced toxic and side effects, maximized the protection of normal tissues and minimized adverse reactions. On the other hand, PTX-anti-LHRHR-PTNPs can be targeted to focus after being injected intravenously and remain in the tumor target tissue for a long time. At the same time, liquid-gas phase-transformation can occur under LIFU triggering, resulting in more ideal and sustained ultrasound imaging effects. Then acoustic contrast agent is used to develop the molecular level of ultrasound scattering, so as to evaluate the diseased tissue from the molecular level.

60 APPLIED LIFE SCIENCES↗

FOCUS: A full-orbit CUDA solver for particle simulations in magnetized plasmas

A Full-Orbit CUDA Solver for particle simulations in plasmas, FOCUS, has been developed. The code follows exact particle trajectories by solving Newton’s equations with the Lorentz force. The code can use fields calculated analytically or numerically and it is also possible to use the information provided by equilibrium reconstruction and transport codes. FOCUS has an elastic collisions module which covers the whole particle energy range in magnetic fusion devices. Moreover, an atomic collision module was also included to simulate the interaction of the test particles with neutral or partially ionized species. Regarding performance, the main feature is that the code runs on GPUs, allowing the simulation of a large number of particles using moderate computational resources. Different versions of the code have been used in several papers. Here we present a complete description of its capabilities, the basis physics included and detailed information about the numerical algorithms employed. Finally, some examples are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE↗

The application of focused ion beam microscopy in the material sciences

This paper describes the application of focused ion beam microscopy in the characterisation of materials. The paper is of a tutorial nature whose aim is to assist the novice user in acquiring high quality, artefact-free data. The design of FIBs is described, together with a brief background on the interactions which occur between the incident ion beam and the specimen. The use of focused ion beam microscopy in a wide range of materials science applications, including specimen preparation methods and in the generation of 3D visualisation is described.

36 MATERIALS SCIENCE↗

Multiscale microstructural characterization of Sn-rich alloys by three dimensional (3D) X-ray synchrotron tomography and focused ion beam (FIB) tomography

Sn-rich (Pb-free) alloys serve as electrical and mechanical interconnects in electronic packaging. It is critical to quantify the microstructures of Sn-rich alloys to obtain a fundamental understanding of their properties. In this work, the intermetallic precipitates in Sn-3.5Ag and Sn-0.7Cu, and globular lamellae in Sn-37Pb solder joints were visualized and quantified using 3D X-ray synchrotron tomography and focused ion beam (FIB) tomography. 3D reconstructions were analyzed to extract statistics on particle size and spatial distribution. In the Sn-Pb alloy the interconnectivity of Sn-rich and Pb-rich constituents was quantified. It will be shown that multiscale characterization using 3D X-ray and FIB tomography enabled the characterization of the complex morphology, distribution, and statistics of precipitates and contiguous phases over a range of length scales. - Highlights: Black-Right-Pointing-Pointer Multiscale characterization by X-ray synchrotron and focused ion beam tomography. Black-Right-Pointing-Pointer Characterized microstructural features in several Sn-based alloys. Black-Right-Pointing-Pointer Quantified size, fraction, and clustering of microstructural features.

36 MATERIALS SCIENCE↗

The Milky Way, coming into focus: Precision astrometry probes its evolution and its dark matter

The growing trove of precision astrometric observations from the Gaia space telescope and other surveys is revealing the structure and dynamics of the Milky Way in ever more exquisite detail. We summarize the current status of our understanding of the structure and the characteristics of the Milky Way, and we review the emerging picture: the Milky Way is evolving through interactions with the massive satellite galaxies that stud its volume, with evidence pointing to a cataclysmic past. It is also woven with stellar streams, and observations of streams, satellites, and field stars offer new constraints on its dark matter, both on its spatial distribution and its fundamental nature. The recent years have brought much focus to the study of dwarf galaxies found within our Galaxy’s halo and their internal matter distributions. In this review, we focus on the predictions of the cold dark matter paradigm at small mass scales through precision astrometric measurements, and we summarize the modern consensus on the extent to which small-scale probes are consistent with this paradigm. We note the discovery prospects of these studies, and also how they intertwine with probes of the dynamics and evolution of the Milky Way in various and distinct ways.

79 ASTRONOMY AND ASTROPHYSICS↗

Depth profile of a time-reversal focus in an elastic solid

The out-of-plane velocity component is focused on the flat surface of an isotropic solid sample using the principle of time reversal. This experiment is often reproduced in the context of nondestructive testing for imaging features near the surface of the sample. However, it is not clear how deep the focus extends into the bulk of the sample and what its profile is. In this paper, this question is answered using both numerical simulations and experimental data. The profiles of the foci are expressed in terms of the wavelengths of the dominant waves, based on the interpretation of the Lamb’s problem and the use of the diffraction limit.

36 MATERIALS SCIENCE↗