Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Customer interface document for the Molten Salt Test Loop (MSTL) system

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate 'solar salt' and can circulate the salt at pressure up to 600psi, temperature to 585 C, and flow rate of 400-600GPM depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

14 SOLAR ENERGY↗

Molten Salt Test Loop (MSTL) system customer interface document.

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate %E2%80%9Csolar salt%E2%80%9D and can circulate the salt at pressure up to 40 bar (600psi), temperature to 585%C2%B0C, and flow rate of 44-50kg/s(400-600GPM) depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

Gill, David Dennis↗

AMORE Mo-99 Spike Test Results

With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solution is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project. There are two separate pumps and flow paths for the acid and base operations. The system contains three sample ladders with eight sample loops per ladder for target mixing; column loading, including acid and water washes; and column stripping, including the final water wash.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation and analysis of a supercritical CO2 Brayton cycle.

Sandia National Laboratories is investigating advanced Brayton cycles using supercritical working fluids for use with solar, nuclear or fossil heat sources. The focus of this work has been on the supercritical CO{sub 2} cycle (S-CO2) which has the potential for high efficiency in the temperature range of interest for these heat sources, and is also very compact, with the potential for lower capital costs. The first step in the development of these advanced cycles was the construction of a small scale Brayton cycle loop, funded by the Laboratory Directed Research & Development program, to study the key issue of compression near the critical point of CO{sub 2}. This document outlines the design of the small scale loop, describes the major components, presents models of system performance, including losses, leakage, windage, compressor performance, and flow map predictions, and finally describes the experimental results that have been generated.

42 ENGINEERING↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

Development of a Thin Film Primary Surface Heat Exchanger for Advanced Power Cycles

This project objective is to develop a high-temperature design upgrade for an existing primary surface heat exchanger so that the redesigned hardware is capable of operation in CO 2 at temperatures up to 1,510°F (821°C) and pressure differentials up to 130 psi (9 bar). The heat exchanger is proposed for use as a recuperator in an advanced low-pressure oxy-fuel Brayton cycle that is predicted to achieve over 50% thermodynamic efficiency, although the heat exchanger could also be used in other high-temperature, low-differential pressure cycles. This report describes the progress to date, which includes continuing work performed to select and test new candidate materials for the recuperator redesign, final mechanical and thermal performance analysis results of various redesign concepts, and the preliminary design of a test loop for the redesigned recuperator including a budgetary estimate for detailed test loop design, procurement, and test operation. A materials search was performed in order to investigate high-temperature properties of many candidate materials, including high-temperature strength and nickel content. These properties were used to rank the candidate materials, resulting in a reduced list of nine materials for corrosion testing. Multiple test rigs were considered and analyzed for short-term corrosion testing and Thermal Gravimetric Analysis (TGA) was selected as the most cost-effective option for evaluating corrosion resistance of the candidate materials. In addition, tantalum, niobium, and chromium coatings were identified as potential options for increased corrosion resistance. The test results show that many materials exhibit relatively low weight gain rates, and that niobium and tantalum coatings may improve corrosion resistance for many materials, while chromium coatings appear to oxidize and debond quickly. Metallurgical analysis of alloys was also performed, showing evidence of intergranular attack in 282 that may cause long-term reliability problems in CO 2 service at these temperatures. However, long-term testing in a flowing environment is recommended in order to understand accurately the severity of the attack. Detailed economic modeling of the existing air cycle recuperator and CO 2 cycle recuperator options was also completed, including costs for material, fabrication, fuel, maintenance, and operation. The analysis results show that the increased capital cost for high-temperature materials may be offset by higher cycle efficiencies, decreasing the overall lifetime cost of the system. The economic analysis also examines costs associated with increased pressure drop and material changes for two redesign options. These results show that, even with slightly reduced performance and/or higher material costs, the lifetime cost per energy production may still be reduced by over 12%. The existing recuperator design information was provided by Solar Turbines, Inc. via several models, drawings, and design handoff meetings. Multiple fluid/thermal and structural models were created in order to analyze critical recuperator performance and mechanical strength in critical areas throughout the redesign process. These models were analyzed for a baseline condition (consistent with current Mercury 50 operation) for validation purposes. Results are presented for heat transfer coefficients and pressure drops, matching well with the existing operational data. Simulation of higher-temperature CO 2 conditions was also performed, showing a slight expected increase in both heat transfer and pressure drop. Mechanical analysis results for critical areas on the cross-flow and counter-flow sheets have also been obtained for air and CO 2 cases. These results show similar stresses in both cases but significantly reduced safety factors for the CO 2 case due to reduced yield and creep rupture strengths of alloy 625 at the higher temperatures. A concept brainstorm session and initial down-selection were completed in order to identify promising redesign options for further analysis. Detailed analysis of all promising redesign options was performed via finite element and computational fluid dynamic simulations in order to characterize mechanical and thermal-fluid performance of each option. These options included material change, various sheet thickness configurations, pitch and phasing of cross-flow and counter-flow sheets, and separator sheets. The analysis results have identified two viable redesign options that maintain existing safety margins optimally through a material change to Haynes 282 and (A) sheet thickness increases of 40% on the counter-flow sheet and 75% on the hot side cross-flow corrugation sheet or (B) addition of a separator sheet in the counter-flow section while maintaining the original counter-flow sheet thickness and increasing the cross-flow corrugation sheet thickness by 90% to account for the increase in cell height. While both options satisfy mechanical stress constraints, the separator sheet design has a higher part count, slightly reduced heat transfer, and slightly higher pressure drop than the first option and is not preferred. Finally, several test loop concepts have been developed for different full-scale and reduced-scale recuperator testing options. For each option, various loop components, such as heat exchangers, valves, heaters, and compressors, were evaluated in an effort to maximize utilization of existing resources. All concepts utilize an existing 3-MW CO 2 compressor, heater, and loop coolers, but the concepts vary by incorporating different amounts of new equipment for achieving various flow rates (all concepts operate at design pressure and temperature). The third concept achieves a 1 kg/s test without purchasing any costly equipment (coolers, heaters, blowers, etc.). Since the stacked cell design of the recuperator results in the same flow conditions at each core cell (even for a reduced-scale test). Thus, test loop Concept #3 was selected for the preliminary design. This loop design is detailed within the report, culminating in a budgetary estimate of $1,013,000.00 for the detailed design, construction, commissioning, and operation of a high-temperature recuperator test loop.

03 NATURAL GAS↗

Development and Validation of Multidimensional Models of Supercritical CO 2 Energy Conversion Systems for Nuclear Power Reactors

A general objective of this project was to develop, verify and validate mechanistic multidimensional models of local flow and heat transfer in supercritical carbon dioxide (S-CO 2 ) devices and systems, and to demonstrate the application of the new models to selected components of S-CO 2 nuclear energy transport systems. Both steady-state and time-dependent operating conditions have been investigated. The overall workscope consisted of the following three major parts: Development, testing and validation of a mechanistic model of forced-convection heat transfer in heated channels cooled using S-CO 2 at slightly supercritical pressures; Development, testing and verification/validation of a new model of the dynamics of closed- loop S-CO 2 heat transport systems; and, Formulation, testing and verification of a mechanistic model for the analysis of flow and pressure distribution in S-CO 2 compressors. The results of the work performed for the project have been documented in several publications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compatibility of V/Y2O3/V-4Cr-4Ti Coatings with Liquid Flowing Li

Characterization was performed on two-layer V/Y2O3 coatings deposited on V-4Cr-4Ti and exposed to Li in a thermal convection loop at 400 -700 C for 2,350h. The coatings exposed at lower temperatures ( 504 C) showed adequate electrical resistivity at 500 C in vacuum after exposure and the morphology of the Y2O3 layer was unchanged. XPS and EELS analysis showed no indication of Li penetration to the oxide layer after exposure at 437 C. However, coatings exposed at higher temperatures ( 565 C) showed higher conductivity after exposure and a change in the Y2O3 grain morphology was apparent using TEM. At the highest temperature, a continuous layer of recrystallized oxide grains was observed adjacent to the substrate suggesting that a reaction occurred between Y2O3 and V-4Cr-4Ti rather than Li infiltration. However, no layer formed during a 2,350h anneal at 700 C of an unexposed coating.

36 MATERIALS SCIENCE↗

NETL - Chemical Looping Reactor

NETL's Chemical Looping Reactor unit is a high-temperature integrated CLC process with extensive instrumentation to improve computational simulations. A non-reacting test unit is also used to study solids flow at ambient temperature. The CLR unit circulates approximately 1,000 pounds per hour at temperatures around 1,800 degrees Fahrenheit.

20 FOSSIL-FUELED POWER PLANTS↗

DOE-GENIORS Dynamic Irradiation Testing

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolytic resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process, and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate the organic and aqueous phases together, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analyzed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or radioactive tracer extraction, and HPLC-MS to identify and quantify the degradation compounds. Despite some differences between the three-irradiation facilities, this inter-institutional study shows that these three comparative tools provide similar trends in the radiolytic stability of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Thermal Hydraulic Characteristics of Fuel Defects in Plate Type Nuclear Research Reactors

Turbulent flow coupled with heat transfer is investigated for a High Flux Isotope Reactor (HFIR) fuel plate. The Reynolds Averaged Navier-Stokes Models are used for fluid dynamics and the transfer of heat from a thermal nuclear fuel plate using the Multi-physics code COMSOL. Simulation outcomes are compared with experimental data from the Advanced Neutron Source Reactor Thermal Hydraulic Test Loop. The computational results for the High Flux Isotope Reactor core system provide a more physically accurate simulation of this system by modeling the turbulent flow field in conjunction with the diffusion of thermal energy within the solid and fluid phases of the model domain. Recommendations are made regarding Nusselt number correlations and material properties for future thermal hydraulic modeling efforts

COMSOL LEU HFIR↗

Interinstitutional Study of the New EURO-GANEX Process Resistance by Gamma Irradiation Test Loops

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. However, EURO-GANEX also has various drawbacks that are being addressed. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolysis resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate together the organic and aqueous phases, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analysed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or tracers extraction, and HPLC-MS to quantify the degradation and evaluate the degradation compounds. Additionally, in spite of some differences between the three-irradiation facilities, this inter-institutional study shows that they are three comparative tools, which provide results on the stability towards radiolysis of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of extreme ultraviolet imaging spectrometer observations of solar coronal loops with Alfvén wave turbulence models

The observed non-thermal widths of coronal emission lines could be due to Alfvén wave turbulence. To test this idea, we examine and analyze the dynamics of an active region observed on 2012 September 7. We use spectral line profiles of Fe XII, Fe XIII, Fe XV, and Fe XVI obtained by the Extreme-ultraviolet Imaging Spectrometer on the it Hinode spacecraft. The observations show non-thermal velocities, Doppler outflows, and intensities for loops in this active region. The observed non-thermal velocities are compared with predictions from models for Alfvén wave turbulence in the observed coronal loops. This modeling takes into account the relationship between the width of the coronal emission lines and the orientation of the coronal loops with respect to the line-of-sight direction. We find that in order to produce the observed line widths we need to introduce a random parallel-flow component in addition to the perpendicular velocity due to Alfvén waves. The observed widths are consistent with photospheric footpoint velocities in the range 0.3-1.5 km s{sup –1}. We conclude that the Alfvén wave turbulence model is a strong candidate for explaining how the observed loops are heated.

79 ASTRONOMY AND ASTROPHYSICS↗

A multi-dimensional dataset for two-phase instability in low pressure natural circulation based on direct transient local measurement

Thermal hydraulic instability can challenge the control and the safety of nuclear reactors. This experimental research captures and investigates the instability in a low-pressure (1–10 atmospheres) natural circulation loop with an adiabatic chimney installed above the heated section. Direct transient local measurement of two-phase flow is performed at multiple axial locations along the flow channel with thermocouples and conductivity probes traversed by customized high-precision mechanisms. Based on the periodicity of oscillations, a post-processing method is proposed to align the data captured non-simultaneously to reconstruct the instability behavior in one representative period. The averaging operation over multiple oscillation cycles is performed to reduce the random errors. Cyclic phenomena are clearly demonstrated by the post-processed data, and rapid void fraction change induced by the flashing is observed to be significant in the driving mechanism for low pressure oscillations. Parametric effects of inlet subcooling, heat flux, inlet flow restriction and system pressure are studied within the experiment range, and qualitative results are explained and compared with existing literature. The ratio between the oscillation period and the travelling time of the fluid particle through the test section is compared with the theoretical value for the density wave oscillation. The new dataset contains directly measured transient multi-dimensional two-phase data along the flow channel for natural circulation under density wave oscillations. The generated dataset is valuable for the validation of system analysis codes and CFD codes in the simulation of natural circulation phenomena and dynamic two-phase flow.

42 ENGINEERING↗

Magnetic properties of electrospun non-woven superconducting fabrics

Non-woven superconducting fabrics were prepared by the electrospinning technique, consisting of Bi{sub 2}Sr{sub 2}CaCuO{sub 8} (Bi-2212) nanowires. The individual nanowires have a diameter of ∼150-200 nm and lengths of up to 100 μm. A non-woven fabric forming a network with a large number of interconnects results, which enables the flow of transport currents through the entire network. We present here magnetization data [M(T) and M(H)-loops] of this new class of superconducting material. The magnetic properties of these nanowire networks are discussed including the irreversibility line and effects of different field sweep rates, regarding the microstructure of the nanowire networks investigated by electron microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CURRENT SHEET ENERGETICS, FLARE EMISSIONS, AND ENERGY PARTITION IN A SIMULATED SOLAR ERUPTION

We investigate coronal energy flow during a simulated coronal mass ejection (CME). We model the CME in the context of the global corona using a 2.5D numerical MHD code in spherical coordinates that includes coronal heating, thermal conduction, and radiative cooling in the energy equation. The simulation domain extends from 1 to 20 R{sub s} . To our knowledge, this is the first attempt to apply detailed energy diagnostics in a flare/CME simulation when these important terms are considered in the context of the MHD equations. We find that the energy conservation properties of the code are quite good, conserving energy to within 4% for the entire simulation (more than 6 days of real time). We examine the energy release in the current sheet as the eruption takes place, and find, as expected, that the Poynting flux is the dominant carrier of energy into the current sheet. However, there is a significant flow of energy out of the sides of the current sheet into the upstream region due to thermal conduction along field lines and viscous drag. This energy outflow is spatially partitioned into three separate components, namely, the energy flux flowing out the sides of the current sheet, the energy flowing out the lower tip of the current sheet, and the energy flowing out the upper tip of the current sheet. The energy flow through the lower tip of the current sheet is the energy available for heating of the flare loops. We examine the simulated flare emissions and energetics due to the modeled CME and find reasonable agreement with flare loop morphologies and energy partitioning in observed solar eruptions. The simulation also provides an explanation for coronal dimming during eruptions and predicts that the structures surrounding the current sheet are visible in X-ray observations.

79 ASTRONOMY AND ASTROPHYSICS↗

PHASE-RESOLVED X-RAY SPECTRA OF MAGNETARS AND THE CORONAL OUTFLOW MODEL

We test a model recently proposed for the persistent hard X-ray emission from magnetars. In the model, hard X-rays are produced by a decelerating electron-positron flow in the closed magnetosphere. The flow decelerates as it radiates its energy away via resonant scattering of soft X-rays, then it reaches the top of the magnetic loop and annihilates there. We test the model against observations of three magnetars: 4U 0142+61, 1RXS J1708-4009, and 1E 1841-045. We find that the model successfully fits the observed phase-resolved spectra. We derive constraints on the angle between the rotational and magnetic axes of the neutron star, the object inclination to the line of sight, and the size of the active twisted region filled with the plasma flow. Using the fit of the hard X-ray component of the magnetar spectrum, we revisit the remaining soft X-ray component. We find that it can be explained by a modified two-temperature blackbody model. The hotter blackbody is consistent with a hot spot covering 1%-10% of the neutron star surface. Such a hot spot is expected at the base of the magnetospheric e {sup ±} outflow, as some particles created in the e {sup ±} discharge flow back and bombard the stellar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗