Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon loss rates from betatron resonances at the Muon g – 2 Storage Ring at Fermilab

The Muon g–2 Experiment at Fermilab (E989) is directed toward measuring the muon magnetic anomaly, a μ = (g–2)/2, with total statistical and systematic errors of 0.14 ppm. Here, this new measurement will serve as strong probe of effects of as yet undiscovered particles beyond the Standard Model (SM), and perhaps validate or disprove other theoretical models beyond the SM. Of special interest is the reduction of muon losses from the storage ring to achieve the precision needed at the Muon g–2 Experiment.

43 PARTICLE ACCELERATORS↗

Experience with crystals at Fermilab accelerators

Crystals were used at Fermilab accelerators for slow extraction and halo collimation in the Tevatron collider, and for channeling radiation generation experiments at the FAST electron linac facility. In this paper we overview past experience and major outcomes of these studies and discuss opportunities for new crystal acceleration R&D program.

43 PARTICLE ACCELERATORS↗

Fermilab Phoebus

The Fermilab Phoebus code contains FNAL site-specific code to customize the Control Systems Studio Phoebus application. Phoebus is a tool used to create and present graphical displays based on current real-time and historic values of sensors, gauges, alarms, and many other devices in accelerators and physics experiments here and at other laboratories around the world.

Velarde, Mariana González [Fermi National Accelera↗

An Energy-Integrated Analysis for Measuring the Anomalous Precession Frequenzc for the Muon g - 2 Experiment at Fermilab

In the search for physics beyond the Standard Model, the Muon g - 2 Experiment at Fermilab (E989) will make the most precise measurement of the anomalous magnetic moment of the muon, a μ . Improvements in precision come from both increased statistics and new techniques to significantly reduce previous systematic uncertainties. The muon a μ is determined by extracting both the anomalous spin precession frequency, ω a , and the average magnetic field sampled by the muons, B. Traditionally an energy threshold analysis method which requires reconstruction of decay positrons from the muon decay, μ + → e + ν e ν μ has been used to extract ω a . This thesis will describe a novel, energy-integrated analysis method for ωa extraction that does not require full reconstruction of positron hits and lowers the energy threshold therefore sampling more of the stored muons. This new technique has different sensitivities to effects like gain fluctuations and positron pulse pile-up. The analysis results will focus on data taken in 2019, the second year of running the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser calibration system for the Muon g-2 Experiment at Fermilab

Muon g-2 experiment at Fermilab is going to measure the anomalous magnetic moment of the muon with a precision of 0.14 ppm like never before. This fourfold precision goal compared to the previous g-2 experiment at BNL required improvements in all fronts, a big part of which will come from the gain correction of the SiPM-based calorimeters using a complex laser calibration system developed by INFN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Muon $g - 2$ experiment: Current status

The Muon $g$ - 2 experiment at Fermilab (E989) is currently measuring the muon magnetic anomaly with a goal precision of 140 part per billion, which will be a fourfold precision improvement over the current best measurement by the previous Muon $g$ -2 experiment at the Brookhaven Laboratory (BNL). The BNL-measured value of the muon magnetic anomaly and the corresponding Standard Model (SM) best estimate differ by more than three standard deviation which inspired the current measurement as well as a theoretical drive for a significantly more precise calculation of the muon magnetic anomaly to rule out (or establish) statistical fluctuation as the origin of such a huge discrepancy. Stable central values along with 4-fold precision improvements in both theoretical (SM) and experimental fronts, would imply a ~ 7σ discrepancy and that will be a clear hint of the physics beyond the Standard Model. Such an unprecedented precision demands state-of-the-art technological improvements in all involved components to keep the systematic uncertainty below 70 ppb. This paper reports the current status of the E989 experiment after two years of data acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon g - 2 experiment at Fermilab

The muon magnetic anomaly aµ = (gµ - 2)/2 is a low-energy observable,which can be both measured and computed to high precision, making ita sensitive test of the Standard Model (SM). In April 2021, the E989 Collaborationat Fermilab National Accelerator Laboratory (FNAL) published the first resultbased on the first year of data taking (Run-1), and in August 2023 a new resultwas published based on two more years of data taking (Run-2 and Run-3). Thenew result was in agreement with the first one and with the previous experimentat Brookhaven National Laboratory (BNL), and the combination of these resultsbrought the uncertainty on the experimental measurement of aµ to the unprecedentedvalue of 0.19 parts per million (ppm). This paper will present details aboutthe improvements and upgrades since the 2021 result, and it will describe the finalstatistical and systematic sources of uncertainty on .a in the 2023 result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modelling Curvilinear Beamline Effects on Beam- and Spin-Dynamics in the Fermilab Muon g-2 Storage Ring.

A model of the Fermilab Muon g-2 Experiment storage ring is developed with the BMAD simulation library for beam- and spin-dynamics studies. Particular focus is given to the electrostatic quadrupoles, the plates of which follow the curvature of the particle design trajectory of the magnetically uniform storage ring. To model these, standard electric multipoles and a novel method based on cylindrical harmonics are investigated and found to accurately match the electric field maps produced for the bulk and fringe regions of the curved quadrupoles respectively, despite these methods being specifically for straight beamlines. The toroidal multipole description is then developed, to include curvature and longitudinal field variations (to model the fringe field regions). Various combinations of the different descriptions (including use of the field maps) are used for the bulk and fringe fields of the quadrupoles, and the toroidal multipoles are found to provide the best agreement with the measured tunes of the storage ring. Two integrators are also developed, based on the method of Wu, Forest and Robin. The first of these describes motion in a uniform magnetic dipole field with arbitrary electric field, and produces results comparable to those of the adaptive-step fourth-order Runge–Kutta integrator implemented in BMAD, suitable for tracking over thousands of turns. The second is a generalisation of the first to arbitrary magnetic vector potentials superimposed on that of the uniform dipole, with arbitrary electric fields, and was also found to agree with the Runge–Kutta integrator. Simulations of antimuon storage for 2000 turns of the storage ring were performed, where losses were studied along with the evolution of beam polarisation. The storage losses, important for reducing the systematic error in the measurement of the muon g-2, were found to be largely due to collimator shape. The correlation between momentum and spin precession frequency reflect the effects expected from the electric field correction in the T-BMT equation, on the order of 10 -6 . Particle injection was also studied, for various injection angles, quadrupole strengths and strengths of injection kick, and in the cases where experimental data was provided, the model was found to be consistent with the experiment.

43 PARTICLE ACCELERATORS↗

Muon-neutrino disappearance with multiple liquid argon time projection chambers in the Fermilab Booster neutrino beam

The Short Baseline Neutrino (SBN) program consists of three liquid argon time projection chamber (LArTPC) experiments: SBND, MicroBooNE and ICARUS, with 110 m, 470 m and 600 m baselines respectively. The detectors are located in the Booster Neutrino Beam (BNB) at Fermilab which has a peak energy around 0.7 GeV and contains predominantly muon neutrinos. The baseline and energy range of the SBN program is conducive to measuring neutrino oscillation parameters under various sterile neutrino hypotheses. Sterile neutrinos have been proposed as a possible solution to the numerous short baseline anomalies. The proposed particles must be sterile in nature such that they do not interact via the weak force, however they may undergo oscillations with the active neutrino flavours. Their existence may consequently be confirmed through measurements of the appearance and disappearance of the active flavours. The analyses presented in this thesis aimed to calculate and understand the sensitivity of the SBN program to measuring the ?µ disappearance parameters under the (3+1) sterile neutrino oscillation hypothesis. The sensitivity of SBN to measuring the ?µ disappearance sterile oscillation parameters, sin2 2?µµ, ?m2 41, was calculated through semi-exclusive joint fits of the ?µ CC 0p and ?µ CC Other reconstructed neutrino energy spectra. The first iteration used truth-level Monte Carlo (MC) events, and determined that the 5s SBN sensitivity is comparable to the 90% MINOS/MINOS+ confidence level and supersedes the 90% MiniBooNE confidence level across entire phase space. Semi-exclusive joint fits of the aforementioned sample spectra were performed between the MC and multiple mock data sets in SBND. This analysis assessed the accuracy with which the near detector can disentangle systematic from physics effects in the oscillation analysis. The result was a 5.49% discrepancy between the ICARUS Monte Carlo and mock data event rates, when the systematic constraints from the near detector fit were extrapolated to the far detector. The second iteration of the SBN sensitivity analysis involved the application of an event selection procedure developed in SBND, following the full reconstruction chain. ?µ CC 0p events were selected from sample of neutrinos with 84.5% efficiency and 84.3% purity. The sterile neutrino sensitivity was determined once more at the near detector with these samples, and was shown to be consistent with the truth-level studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Design, Construction and Testing of the Straw Tracking Detectors for the E989 Muon g-2 Experiment at Fermilab.

The requirement of science, to stretch the boundaries and our understanding of the standard model,is the driving force for the continuous development of our knowledge of the building blocks of theUniverse. Experiments are designed, built and tested to support the theories of the mathematiciansof the physics community and the theorists help interpret the experimental results, looking foravenues of new physics. However, as is known in both science and human nature, nothing is everperfect - there is always room for improvement.The E989 Muon g-2 Collaboration experiment at Fermi National Accelerator Laboratory (otherwiseknown as Fermilab), aims to quantify the muon anomalous magnetic moment to unprecedentedprecision and looks to increase the accuracy of the measurement by fourfold of the predecessorexperiment - E821 at Brookhaven. The discrepancy between the theoretical prediction of theanomalous magnetic moment of the muon and the experimental results, has given tantalisingindication of new physics, prompting an ”upgrade” for systematic accuracy on the E821.The particular focus of this thesis details the design, construction and quality testing of the strawtracking modules for the E989 experiment. The author was one of the dedicated technicians whobuilt and tested the tracker modules at the University of Liverpool High Energy Physics (HEP)department, she built and quality tested the modules, wrote the procedural document for the buildand subsequently was involved in the Run I startup, shut down and data taking shifts (for Run Iand Run II) which contributed to the recent release of the first unblinded data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Cascaded Longitudinal-Space-Charge Amplifier at the Fermilab Accelerator Science & Technology (Fast) Facility

Cascaded Longitudinal Space Charge Amplifiers (LSCA) have been proposed as a mechanism to generate density modulation over a board spectral range. The scheme has been recently demonstrated in the optical regime and has confirmed the production of broadband optical radiation. In this paper we investigate, via numerical simulations, the performance of a cascaded LSCA beamline at the Fermilab Accelerator Science & Technology (FAST) facility to produce broadband ultraviolet radiation. Our studies are carried out using elegant with included tree-based grid-less space charge algorithm.

43 PARTICLE ACCELERATORS↗

High Spectral Density Compton Back-Scattered Gamma-Ray Sources at Fermilab

A ~1 MeV gamma-ray source is planned to be built at Fermilab following the completion of the ~300 MeV superconducting linac. The high-energy photons are back-scattered from the interactions between electrons and high-intensity IR laser pulses. In this contribution, we discuss some of the experiment design challenges and evaluate the performances of the gamma-ray source. We expect the peak brilliance to be of the order of 10²² photons/s-(mm-mrad)²-0.1\% BW and the spectral density of the radiation in excess of 3x10⁵ photons/s/eV.

43 PARTICLE ACCELERATORS↗

Fermilab - The Proton Improvement Plan (PIP)

The Fermilab Proton Source is composed of three machines: an injector line, a normal conducting Linac and a Booster synchrotron. The proton improvement plan was proposed in 2012 to address the necessary accelerator upgrades and hardware modification to allow an increase in proton throughput, while maintaining acceptable activation levels, ensuring viable operation of the proton source to sustain the laboratory HEP program. A summary of work performed and respective results will be presented.

43 PARTICLE ACCELERATORS↗

Measurement of Stability Diagram at IOTA at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders by means of Landau Damping, through the tune spread which is introduced. We propose an experiment at Fermilab’s Integrable Optics Test Accelerator (IOTA) to investigate the influence of nonlinear focusing elements on the transverse stability of the beam. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper, we can examine the impact of the nonlinear focusing element on the beam’s transverse stability. The stability diagram, a tool used to determine the system’s stability, will be measured using a recently demonstrated method at the LHC. This measurement is carried out experimentally by selecting specific threshold gains and measuring them for a range of phases. The stability diagram is represented by gei¿ on the complex plane. The experiment at IOTA adds insight towards the stability diagram measurement method by supplying a reduced machine impedance, to investigate the impedance’s effect on the stability diagram, as well as a larger range of phase measurements.

43 PARTICLE ACCELERATORS↗

Investigation of Tail-dominated Instability in the Fermilab Recycler Ring

In our recent operational run, a single bunch, tail-dominated instability was observed in the Fermilab Recycler ring. This instability exclusively occurs in the vertical plane when the chromaticity is close to zero. In this study, we conduct a detailed analysis of this instability under different operational parameters. We investigate the impact of space charge on the head-tail motion and propose potential interpretations of the underlying mechanism of the instability. Moreover, we explore methods to mitigate this instability in the future.

43 PARTICLE ACCELERATORS↗