Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

Face crack reduction strategy for particulate filters

A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and at least one portion. A control module initiates combustion of PM in the PM filter using a heater and selectively adjusts oxygen levels of the exhaust gas to adjust a temperature of combustion adjacent to the at least one portion of the PM filter. A method comprises providing a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and at least one portion; initiating combustion of PM in the PM filter using a heater; selectively adjusting oxygen levels of the exhaust gas to adjust a temperature of combustion adjacent to the at least one portion of the PM filter.

42 ENGINEERING↗

METAL MEDIA FILTERS, AG-1 SECTION FI

One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures, media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.

42 ENGINEERING↗

Variable bandwidth filter

A variable bandwidth filter is described herein, wherein a bandwidth of a passband of the variable bandwidth filter is dynamically tunable. The variable bandwidth tuner is implemented on a CMOS chip, and acts to filter analog signals. The variable bandwidth filter comprises a plurality of finite impulse response (FIR) filters, wherein each FIR filter comprises a plurality of tunable transconductors. The tunable transconductors are tunable in their gain.

Rodenbeck, Christopher T.↗

Method for concentrating solids and removing solids from a filter medium

Disclosed are methods for concentrating solids and removing solids from a filter medium. The method includes the step of concentrating first particles of a first solid by removing a fluid stream through a filter medium in a filter. At least some of the first particles become blocking particles that block pores of the filter medium. The method also includes the step of inserting second particles of a second solid into the filter. These second particles scrape, vibrate, agglomerate, or a combination thereof along the filter medium, thus dislodging at least a portion of the blocking particles.

Frankman, David↗

Hydrophobic Filter Material for Nuclear Material Transportation and Storage Containers - 17518

Los Alamos National Laboratory has begun development of hydrophobic or super-hydrophobic inorganic filter materials that resist water ingress after exposure to radiation and/or elevated temperature. Filters that are currently available depend on carbon composites and/or organic polymers for their water resistant/hydrophobic properties to minimize water ingress. However, facility and transportation accident scenarios often include fire, impact and subsequent water spray or flooding conditions. A purely inorganic hydrophobic filter material could have enhanced resistance to fire and radiation damage, and continue to minimize water ingress after such an accident. Such filters could broaden the use of filtered containers in the transportation and storage of nuclear materials, and could have broader implications in other industrial applications. The goal is to create a porous inorganic material with hydrophobic properties that maintains or exceeds the current performance criteria for particulate filtration efficiency, pressure differential, air flow and hydrogen diffusion. The materials developed in this project show promise in evaluations for use as enhancements to the SAVY 4000 nuclear storage container that is becoming widely used around the DOE complex. Preliminary results indicate that the treated filters provide resistance to a water column pressure test and have filtration efficiencies and air flow pressure drops that meet the current performance criteria. There are various treatment options being tested to help determine the best path forward. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of High Strength HEPA Filters for Use in Demanding Air and Gas Streams - 17644

High-efficiency particulate air (HEPA) filters are used in a wide variety of applications, including the removal of radioactive particulate from process off-gas streams and the venting of waste storage containers. Porvair Filtration Group, specializing in the design and manufacture of robust filters in numerous industries, has worked to develop HEPA filter designs for use in such high-demand nuclear process-gas and air streams. Using the requirements of section FK of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment (ASME AG-1) as a guide, Porvair Filtration Group has designed filters which can withstand upset conditions to include elevated temperatures, high relative humidity, high particle-loading, and an unconventionally high differential pressure across the filter media; while maintaining excellent removal efficiencies. The process by which Porvair Filtration Group has reached optimized designs was based upon an extended test and development program. Design, manufacture, and testing of flat sheet media samples, geometrically equivalent model filters, and full-scale prototypes was performed at several Porvair Filtration Group facilities located in the United States and the United Kingdom. The methods and results of this development program are outlined in the following paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanomaterial-Treated Filters for the Uptake of Heavy Metals from Water Sources

We describe the synthesis and properties of ligand-modified gold nanoparticles (AuNPs) grown on stainless steel wool filters. Their selectivity and efficiency with regards to heavy metal uptake from groundwater and other sources of drinking water found at or near DOE facilities were also investigated. The nanomaterial-treated filters are advantageous because they serve as inactive supports that allow for efficient flow of the contaminated water, and can be easily replaced after heavy metal uptake. They are also comparable to nanomaterials free in solution with regards to the effectiveness of remediation of drinking water. Environmental stewardship is at the forefront of core competencies at SRNS. This includes treatment and remediation of contaminated groundwater. Among contaminants present in water resources, hazardous heavy metals and radioactive contaminants are the main concerns in the DOE complex. With the advent of nanotechnology, new remediation technologies have emerged. AuNPs have unique optical properties and enormous surface areas, making them good candidates for water remediation. They can be functionalized with ligands, e.g. citrate and L-cysteine, allowing them to serve as an excellent platform for environmental stewardship applications. Objectives: 1. Nanomaterial development and characterization Ligand-modified AuNPs: (a) in solution and (b) on stainless steel wool filters 2. Nanomaterial evaluation for efficiency and selectivity of heavy metal uptake, including Cu{sup 2+} and Zn{sup 2+}. Materials and Methods: Chloroauric acid (HAuCl{sub 4}), sodium citrate (reducing and capping agent); Stainless steel wool (SSW) was used as a support and filter; L-cysteine- ligand for surface functionalization; Zinc acetate and copper nitrate: heavy metal ions contaminants. Au NPs were prepared by wet chemistry methods. They were characterized by UV-Vis, Zeta sizer and potential, SEM, EDS and EDS mapping to understand their physico-chemical properties. Results and Discussions: Surface modification of AuNPs with surfactants changes their optical properties. Citrate capped AuNPs demonstrate high loading capacity for both heavy metals. L-cysteine capped AuNPs demonstrate high loading capacity for Zn{sup 2+}. Citrate capped AuNPs have excellent sensitivity towards heavy metal ions (0.05 mM can be detected). L-cysteine capped AuNPs can detect heavy metal ions at low concentrations, making them useful for sensing. Conclusions: AuNPs in solution and on SSW were successfully synthesized and characterized. Two functional sensing and remediation technologies - colorimetric sensor and AuNP-treated filters - were developed through wet chemistry methods. AuNP SSW filters exhibit different characteristics (size, shape, etc.) than AuNPs in solution and are efficient at the uptake of heavy metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Tiny Median Filter: A Small Size, Flexible Arbitrary Percentile Finder Scheme Suitable for FPGA Implementation

This document reports the design, implementation and testing of a small silicon resource usage, very flexible arbitrary percentile finding scheme called the Tiny Median Filter. It can be used not only as a median filter in image processing with square filtering windows, but also for applications of any percentile filter or maximum or minimum finder with any size of data set as long as the number of bits of the data is finite. It opens possibilities for image processing tasks with non-square or irregular filter windows. In this scheme, data swapping or data bit manipulating are avoided and high functional efficiency of the logic components is applied to save silicon resources. Some logic functions are absorbed into other functions to further reduce the complexity. The combinational logic paths are designed to be sufficiently short so that the firmware can be compiled to the maximum operating frequency allowed by the block memories of the FPGA devices. The Tiny Median Filter receives, processes and output data in non-stop manner with no irregular timing which helps to simplify design of surrounding stages.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗

Performance of a New Composite Single-Crystal Filtered Thermal Neutron Beam for Neutron Capture Therapy Research at the University of Missouri

The University of Missouri (MU) Institute for Nano and Molecular Medicine, the Idaho National Laboratory (INL) and the University of Missouri Research Reactor (MURR) have undertaken a new collaborative research initiative to further the development of improved boron delivery agents for BNCT. The first step of this effort has involved the design and construction of a new thermal neutron beam irradiation facility for cell and small-animal radiobological research at the MURR. In this paper we present the beamline design with the results of pertinent neutronic design calculations. Results of neutronic performance measurements, initiated in February 2008, will also be available for inclusion in the final paper. The new beam will be located in an existing 152.4 mm (6’) diameter MURR beam tube extending from the core to the right in Figure 1. The neutron beam that emanates from the berylium reflector around the reactor is filtered with single-crystal silicon and single-crystal bismuth segments to remove high energy, fission spectrum neutrons and reactor gamma ray contamination. The irradiation chamber is downstream of the bismuth filter section, and approximately 3.95 m from the central axis of the reactor. There is sufficient neutron flux available from the MURR at its rated power of 10 MW to avoid the need for cryogenic cooling of the crystals. The MURR operates on average 150 hours per week, 52 weeks a year. In order to take advantage of 7800 hours of operation time per year the small animal BNCT facility will incorparate a shutter constucuted of boral, lead, steel and polyethylene that will allow experimenters to access the irradiation chamber a few minutes after irradiation. Independent deterministic and stochastic models of the coupled reactor core and beamline were developed using the DORT two-dimensional radiation transport code and the MCNP-5 Monte Carlo code, respectively. The BUGLE-80 47-neutron, 20-gamma group cross section library was employed for the DORT computations, in keeping with previous practice for analysis of a number of other NCT neutron facilities worldwide. The standard ENDF/B Version 6.8 cross section libraries were used with MCNP, except that special calculated cross section sets for the single-crystal bismuth and silicon filters in the MCNP calculations were provided to MU and INL specifically for this study by the Korean Atomic Energy Research Institute and, independently, by North Carolina State University. Cross sections for the amorphous bismuth and silicon files on the BUGLE-80 library used with DORT were modified to account for the single-crystal form of these materials using correction factors computed using MCNP. A number of parameter studies were conducted, independently varying the thicknesses of the silicon and bismuth filter sections to find an optimum that maximizes the thermal neutron flux while maintaining the fast-neutron and gamma components of the beam within acceptable ranges. Both the DORT and MCNP beamline optimization computations led to the conclusion that the silicon filtering section should be approximately 55 cm in thickness and the bismuth section should be 8 cm in thickness. The total estimated thermal neutron flux delivered to the irradiation location by the filtered beam, integrated to 0.414 eV, is approximately 9.0 x 108 neutrons/cm2-s. The calculations also yielded an epithermal and fast-neutron kerma of approximately 1.0 x 10-11 cGy-cm2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method and apparatus for selective filtering of ions

An adjustable, low mass-to-charge (m/z) filter is disclosed employing electrospray ionization to block ions associated with unwanted low m/z species from entering the mass spectrometer and contributing their space charge to down-stream ion accumulation steps. The low-mass filter is made by using an adjustable potential energy barrier from the conductance limiting terminal electrode of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from being transmitted. The filter provides a linear voltage adjustment of low-mass filtering from m/z values from about 50 to about 500. Mass filtering above m/z 500 can also be performed; however, higher m/z species are attenuated. The mass filter was evaluated with a liquid chromatography-mass spectrometry analysis of an albumin tryptic digest and resulted in the ability to block low-mass, "background" ions which account for 40-70% of the total ion current from the ESI source during peak elution.

47 OTHER INSTRUMENTATION↗

Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level alpha/beta Counter

Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr{sup 90}, Pu{sup 239}, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level alpha/beta Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aalpha = (0.19+-0.01) Bq/filter and Aalpha(IAEA) = (0.17+-0.009) Bq/filter; A{sub b}eta = (0.33+-0.009) Bq/filter and A{sub b}eta (IAEA) = (0.29+-0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

54 ENVIRONMENTAL SCIENCES↗

OPTICAL CROSS-CORRELATION FILTERS: AN ECONOMICAL APPROACH FOR IDENTIFYING SNe Ia AND ESTIMATING THEIR REDSHIFTS

Large photometric surveys of transient phenomena, such as Panoramic Survey Telescope and Rapid Response System and Large Synoptic Survey Telescope, will locate thousands to millions of Type Ia supernova (SN Ia) candidates per year, a rate prohibitive for acquiring spectroscopy to determine each candidate's type and redshift. In response, we have developed an economical approach to identifying SNe Ia and their redshifts using an uncommon type of optical filter which has multiple, discontinuous passbands on a single substrate. Observation of a supernova through a specially designed pair of these 'cross-correlation filters' measures the approximate amplitude and phase of the cross-correlation between the spectrum and a SN Ia template, a quantity typically used to determine the redshift and type of a high-redshift SN Ia. Simulating the use of these filters, we obtain a sample of SNe Ia which is approx98% pure with individual redshifts measured to sigma{sub z} = 0.01 precision. The advantages of this approach over standard broadband photometric methods are that it is insensitive to reddening, independent of the color data used for subsequent distance determinations which reduce selection or interpretation bias, and because it makes use of the spectral features its reliability is greater. A great advantage over long-slit spectroscopy comes from increased throughput, enhanced multiplexing, and reduced setup time resulting in a net gain in speed of up to approx30 times. This approach is also insensitive to host galaxy contamination. Prototype filters were built and successfully used on Magellan with LDSS-3 to characterize three SuperNova Legacy Survey candidates. We discuss how these filters can provide critical information for the upcoming photometric supernova surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Consistent boundary conditions for PDE filter regularization in topology optimization

Abstract Design variables in density-based topology optimization are typically regularized using filtering techniques. In many cases, such as stress optimization, where details at the boundaries are crucially important, the filtering in the vicinity of the design domain boundary needs special attention. One well-known technique, often referred to as “padding,” is to extend the design domain with extra layers of elements to mitigate artificial boundary effects. We discuss an alternative to the padding procedure in the context of PDE filtering. To motivate this augmented PDE filter, we make use of the potential form of the PDE filter which allows us to add penalty terms with a clear physical interpretation. The major advantages of the proposed augmentation compared with the conventional padding is the simplicity of the implementation and the possibility to tune the boundary properties using a scalar parameter. Analytical results in 1D and numerical results in 2D and 3D confirm the suitability of this approach for large-scale topology optimization.

42 ENGINEERING↗

Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success

Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11-95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients had an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of an IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗