Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Case Study: Seattle Waterfront Networked Microgrid Evaluation - Case Study for Port Electrification Handbook

Many ports and waterfronts are evaluating alternative electrification efforts, including electrification of passenger and vehicle ferries. In Seattle, the Washington State Department of Transportation, in conjunction with Seattle City Light (the local utility) and the Port of Seattle, are working to deploy a hybrid electric ferry and provide charging at Seattle’s Colman dock. As part of this ferry electrification effort, Seattle City Light is considering including a large battery energy storage system (BESS) to help “buffer” the ferry charging. The “buffer” provides energy arbitrage and spreads out the large amount of power needed to recharge the ferry to times when the ferry is out of the dock – rather than one very large peak for 15 minutes, the battery storage allows it to be a smaller power value over a longer duration. This initial BESS concept served as the jumping off point to explore an expanded microgrid concept via a notional test system that incorporates additional distributed energy resources (DER) and infrastructure upgrades to the local distribution infrastructure at the Seattle Waterfront and neighboring Port of Seattle properties. This case study examined the potential for secondary use of the BESS within a networked microgrid during the scenario of a large-scale power outage, such as a natural disaster.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From material properties to multiscale modeling to improve lithium-ion energy storage safety

Energy storage using lithium-ion cells dominates consumer electronics and is rapidly becoming predominant in electric vehicles and grid-scale energy storage, but the high energy densities attained lead to the potential for release of this stored chemical energy. This article introduces some of the paths by which this energy might be unintentionally released, relating cell material properties to the physical processes associated with this potential release. The selected paths focus on the anode–electrolyte and cathode–electrolyte interactions that are of typical concern for current and near-future systems. Relevant material processes include bulk phase transformations, bulk diffusion, surface reactions, transport limitations across insulating passivation layers, and the potential for more complex material structures to enhance safety. We also discuss the development, parameterization, and application of predictive models for this energy release and give examples of the application of these models to gain further insight into the development of safer energy storage systems.

25 ENERGY STORAGE↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Cost Analysis of Heavy-Duty Vehicle Proton Exchange Membrane Fuel Cell Stationary Power Plants

Heavy-duty PEM fuel cells could be a low-cost, low emission alternative to combustion turbines for re-electrifying hydrogen if used as part of a long duration grid energy storage systems. Many studies expect heavy duty PEM fuel cell production costs to reduce as manufacturing volumes ramp up and their expected durability of 25,000-30,000 hours aligns well with a 30-year life for hydrogen seasonal energy storage plants that would likely operate less than 10% of the year. The labor, material, and equipment costs associated with installing PEM fuel cells and their required balance of plant for stationary applications have not been thoroughly explored, however. This study performs a detailed design and cost analysis of a 100 MW stationary PEM fuel cell power plant, capturing costs such as cooling, power electronics, pipes, valves, fittings, cabling, conduit, concrete foundations, buildings, and land. It employs methods consistent with NLR's solar PV benchmarking cost analysis and annual technology baseline to derive the total installed costs of stationary PEM fuel cell plants that utilize heavy duty PEM fuel cells.

08 HYDROGEN↗

Dataset For: A Guide to Residential Energy Storage and Rooftop Solar: State Net Metering Policies and Utility Rate Tariff Structures

Federal and state decarbonization goals have led to numerous financial incentives and policies designed to increase access and adoption of renewable energy systems. In combination with the declining cost of both solar photovoltaic and battery energy storage systems and rising electric utility rates, residential renewable adoption has become more favorable than ever. However, not all states provide the same opportunity for cost recovery, and the complicated and changing policy and utility landscape can make it difficult for households to make an informed decision on whether to install a renewable system. This paper is intended to provide a guide to households considering renewable adoption by introducing relevant factors that influence renewable system performance and payback, summarized in a state lookup table for quick reference. Five states are chosen as case studies to perform economic optimizations based on net metering policy, utility rate structure, and average electric utility price; these states are selected to be representative of the possible combinations of factors to aid in the decision-making process for customers in all states. The results of this analysis highlight the dual importance of both state support for renewables and price signals, as the benefits of residential renewable systems are best realized in states with net metering policies facing the challenge of above-average electric utility rates. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit. Suggested modifications include: location, household load profile, rate tariff structure, and renewable energy system design.

14 SOLAR ENERGY↗

Backup Power Performance of Solar-plus-Storage Systems during Routine Power Interruptions: A Case Study Application of Berkeley Lab’s PRESTO Model

This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.

14 SOLAR ENERGY↗

An innovative heterogeneous transfer learning framework to enhance the scalability of deep reinforcement learning controllers in buildings with integrated energy systems

Deep Reinforcement Learning (DRL)-based control shows enhanced performance in the management of integrated energy systems when compared with Rule-Based Controllers (RBCs), but it still lacks scalability and generalisation due to the necessity of using tailored models for the training process. Transfer Learning (TL) is a potential solution to address this limitation. However, existing TL applications in building control have been mostly tested among buildings with similar features, not addressing the need to scale up advanced control in real-world scenarios with diverse energy systems. This paper assesses the performance of an online heterogeneous TL strategy, comparing it with RBC and offline and online DRL controllers in a simulation setup using EnergyPlus and Python. The study tests the transfer in both transductive and inductive settings of a DRL policy designed to manage a chiller coupled with a Thermal Energy Storage (TES). The control policy is pre-trained on a source building and transferred to various target buildings characterised by an integrated energy system including photovoltaic and battery energy storage systems, different building envelope features, occupancy schedule and boundary conditions (e.g., weather and price signal). The TL approach incorporates model slicing, imitation learning and fine-tuning to handle diverse state spaces and reward functions between source and target buildings. Results show that the proposed methodology leads to a reduction of 10% in electricity cost and between 10% and 40% in the mean value of the daily average temperature violation rate compared to RBC and online DRL controllers. Moreover, online TL maximises self-sufficiency and self-consumption by 9% and 11% with respect to RBC. Conversely, online TL achieves worse performance compared to offline DRL in either transductive or inductive settings. However, offline Deep Reinforcement Learning (DRL) agents should be trained at least for 15 episodes to reach the same level of performance as the online TL. Therefore, the proposed online TL methodology is effective, completely model-free and it can be directly implemented in real buildings with satisfying performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive Battery Lifetime Modeling at NREL [Slides]

Battery lifetime models are used to extrapolate data from accelerated aging tests to simulate degradation in real-world applications such as electric vehicles and battery energy storage systems. Methods developed at NREL utilize both expert domain-knowledge and machine-learning to identify models, using statistical methods such as cross-validation and bootstrap resampling to interrogate model performance and quantify uncertainty. These models can be utilized in systems level simulations to predict battery performance or technoeconomic models to estimate the lifetime cost of battery systems.

25 ENERGY STORAGE↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

High temperature thermochemical energy storage materials

Disclosed are thermal energy storage systems and methods that utilize metal carbonate eutectics that can undergo high temperature reversible reactions to form mixtures of metal oxides. The metal oxides undergo an exothermic reaction with carbon dioxide to form the molten metal carbonate eutectics, and the molten metal carbonate eutectics undergo an endothermic decarbonization reaction to form the metal oxides and carbon dioxide. By carrying out the reversible reactions at a temperature above the melting point of the carbonate eutectic, the systems provide high thermal conductivity and reversible stability for thermal energy storage.

25 ENERGY STORAGE↗

Ferromagnetic Atomic d ‐ p Orbital Hybridization for Promoting Al‐S Batteries

Rechargeable aluminum‐sulfur batteries (Al‐S) are emerging as a promising alternative energy storage system beyond lithium‐ion batteries due to their high energy density, abundant material resources, and economic efficiency. However, their practical application remains challenged by sluggish conversion kinetics, polysulfide shuttling, and low sulfur cathode utilization. While extensive studies have focused on enhancing polysulfide adsorption through catalytic strategies, the roles of electronic structure in dictating catalytic performance remain underexplored. Here, this work unveils the critical effect of unpaired electronic structure on the catalytic performance of single atom ferromagnetic transition metals through a systematic evaluation of three typical atomically dispersed ferromagnetic single atoms—Fe, Co, and Ni—supported on porous carbon (denoted as PC‐SAFAs). Comprehensive characterizations and density functional theory (DFT) calculations reveal that the PC‐SAFe catalysts, exhibiting the highest spin polarization arising from unpaired electrons, demonstrate the strongest interactions with polysulfide, thereby facilitating rapid and reversible polysulfide conversion reactions. Consequently, Al‐S batteries incorporating the optimized PC‐SAFe cathode achieve an impressive specific capacity of 508.8 mAh g −1 at 1.0 A g −1 after 500 cycles, along with much improved rate capability. In conclusion, this work provides a deeper understanding of the role of electronic structure in catalytic chemistry, and offers new insights for developing high‐performance Al‐S batteries.

36 MATERIALS SCIENCE↗

Implications of Local Cathode Structure in Solid-State Batteries

Solid-state batteries (SSBs) are promising candidates for energy storage systems—specifically for automotive applications—owing to their higher energy density and supreme safety. SSBs currently must improve area-specific cathode loadings as well as the electro-chemo-mechanical stability at high voltages. Composite cathodes in SSBs are comprised of active material, ion and electronic conductors, binders, and electronic conducting materials. In addition to experimental limitations with engineering thick cathode architectures, low utilization and chemomechanical degradation of the cathodes limit the performance of composite cathodes. Composite cathodes must optimize several parameters simultaneously to achieve high performances that include loading, electrochemically active surface area, mechanical resilience, and porosity. This chapter summarizes the current state-of-the-art applications with regard to composite cathodes for SSBs and provides insights into cathode architectures using geometric packing models. Tailoring ion and electron transport pathways within the electrode while mitigating operational stresses is crucial for achieving energy-dense cathode structres for SSBs.

Dixit, Marm↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

Federal Aviation Administration Vertiport Electrical Infrastructure Study

In this detailed analysis, the authors assess the charging infrastructure needed for the deployment of advanced air mobility involving electrified vertical take-off and landing technologies. The report covers four research areas: (1) Identifying charging infrastructure requirements for existing facilities based on flight operational parameters, potential use cases, charging strategy, and other constraints. (2) Assessing sites on power availability to meet charging demand, the impact on grid infrastructure, potential hazards, and cybersecurity needs, and using technoeconomic analysis to identify opportunities for onsite distributed energy resources, primarily solar photovoltaics and battery energy storage systems. (3) Calculating greenhouse gas emission based on total energy consumption attributable to each site. (4) Analyzing the job and economic development impact for sites adopting new infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic and Responsive Distributed Energy Resource Education Solutions for Building, Fire, and Safety Department Officials (Final Technical Report)

From April 2021 through March 2024, the Interstate Renewable Energy Council (IREC) led a collaborative project to develop a free online clearinghouse of educational resources about solar photovoltaics (PV), energy storage systems (ESS), electric vehicle supply equipment (EVSE), and grid-interactive efficient building (GEB) technologies. Two websites—the Clean Energy Clearinghouse and CleanEnergyTraining.org—housed over 70 educational resources. Over the course of the three-year project, 154,272 unique visitors accessed the learning materials. Learner feedback was overwhelmingly positive. Even through the end of the project, there was sustained demand for education and communication. A primary innovation of the project was to drive multiple complementary audiences to the same place. Building owners, designers, installation contractors and developers, authorities having jurisdiction (AHJs), and fire service personnel all benefit from a shared understanding of clean energy technologies, including safety and code-related requirements. When considering the impact on the target audience, the project team worked with partners and advisors to inform resource creation and delivery in such a way as to address key motivational factors of the target audience and compel each user to seek additional information on the topic and return to the Clean Energy Clearinghouse website as their central location for more information. Resources were intentionally developed to be concise—five to 15 minutes—and accessible, meaning not overly technical. Providing basic information demystified the technologies and invited the professional to explore additional learning opportunities. Awardee and partner collaboration was key to project success. IREC facilitated collaboration among the other Topic 2 awardees, Southface and New Buildings Institute (NBI). The three awardees shared relevant information gained through discovery and validation questionnaires that informed product development and reduced duplication of effort by coordinating the development of complementary, and not competing, educational resources. Inspired by this collaboration, IREC brought on additional partners even in the final year of the project. Five regional energy efficiency organizations were part of the project, which expanded the connection between efficiency and distributed energy resources. We also included resources on the Clearinghouse that were developed through other federally funded projects, such as the Buildings Energy Efficiency Frontiers & Innovation Technologies (BENEFIT) program. The website was developed with the learner in mind, and not solely the funding source. Feedback from stakeholders throughout the project, and especially in its final year, indicated the need for continued education and facilitated communication among stakeholders to further the safe and widespread adoption of clean energy.

14 SOLAR ENERGY↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase change materials for thermal energy storage: A perspective on linking phonon physics to performance

Thermal energy storage is being actively investigated for grid, industrial, and building applications for realizing an all-renewable energy world. Phase change materials (PCMs), which are commonly used in thermal energy storage applications, are difficult to design because they require excellent energy density and thermal transport, both of which are difficult to predict from simple physics-based models. In this Perspective, we describe recent advances in the understanding of the equilibrium and transport properties of PCM materials that can help accelerate technology development. We then emphasize how the microscopic phonon picture of both liquids and solids enables a better understanding of novel PCM systems and their predictive power. Here, we then show how this microscopic picture can be used to understand kinetic processes, such as supercooling, and how it can impact the thermal power output in thermal energy storage systems.

25 ENERGY STORAGE↗