Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Visible to Near Infrared Emission Spectra of Electron-Excited H2

The electron-impact induced fluorescence spectrum of H2 at 100 eV from 700 nm to 950 nm at a spectral resolution of between 0.2 nm to 0.3 nm has been measured. The laboratory spectrum has been compared with our theoretical simulated spectrum obtained by calculating the lines emission cross sections from the upper states of g symmetry (EF, GK, HH, P, O ; I, R, J, S ) towards the states of u symmetry (B, C, B', D) of H2. The nine above Born-Openheimer g-upper states have been coupled together as well as the four above Born-Openheimer u-lower states. The comparison seems adequate with few minor discrepancies.

Aguilar, A.↗

Experimental electron energy-loss spectra and cross sections for the 4/2/S - 4/2/P transition in Zn II

Electron energy-loss spectra and differential cross sections are reported for inelastic scattering from Zn II. Measurements were carried out in a crossed electron beam-ion beam apparatus, at incident electron energies of 30, 40, 50, 60, 75, 85, and 100 eV, and at a scattering angle of 14 deg. The present results are the first reported measurements of inelastic electron scattering from an ion.

Chutjian, A.↗

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

Time-of-flight electron spectrometer for a broad range of kinetic energies

A newly constructed time-of-flight electron spectrometer of the magnetic bottle type is characterized for electron detection in a broad range of kinetic energies. The instrument is designed to measure the energy spectra of electrons generated from liquids excited by strong laser fields and photons in the range of extreme ultra violet and soft X-rays. Argon inner shell electrons were recorded to calibrate the spectrometer and investigate its characteristics, such as energy resolution and collection efficiency. Its energy resolution {Delta}E/E of 1.6% allows resolving the Ar 2p spin orbit structure at kinetic energies higher than 100 eV. The collection efficiency is determined and compared to that of the spectrometer in its field-free configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface-electronic-state effects in electron emission from the Be(0001) surface

We study the electron emission produced by swift protons impinging grazingly on a Be(0001) surface. The process is described within a collisional formalism using the band-structure-based (BSB) approximation to represent the electron-surface interaction. The BSB model provides an accurate description of the electronic band structure of the solid and the surface-induced potential. Within this approach we derive both bulk and surface electronic states, with these latter characterized by a strong localization at the crystal surface. We found that such surface electronic states play an important role in double-differential energy- and angle-resolved electron emission probabilities, producing noticeable structures in the electron emission spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement and interpretation of moments in inclusive semileptonic decays B{yields}X{sub c}l{sup -{nu}}

We present results for the moments of observed spectra in inclusive semileptonic B-meson decays to charm hadrons B{yields}X{sub c}l{sup -{nu}}. Moments of the hadronic-mass and the combined mass-and-energy spectra for different minimum electron or muon momenta between 0.8 and 1.9 GeV/c are obtained from a sample of 232x10{sup 6} {Upsilon}(4S){yields}BB events, collected with the BABAR detector at the PEP-II asymmetric-energy B-meson factory at SLAC. We also present a reevaluation of the moments of electron-energy spectra and partial decay fractions B(B{yields}X{sub c}e{sup -{nu}}) for minimum electron momenta between 0.6 and 1.5 GeV/c based on a sample of 51x10{sup 6} {Upsilon}(4S){yields}BB events. The measurements are used for the extraction of the total decay fraction, the Cabibbo-Kobayashi-Maskawa (CKM) matrix element |V{sub cb}|, the quark masses m{sub b} and m{sub c}, and four heavy-quark QCD parameters in the framework of a Heavy-Quark Expansion (HQE). We find B(B{yields}X{sub c}l{sup -{nu}})=(10.64{+-}0.17{+-}0.06)% and |V{sub cb}|=(42.05{+-}0.45{+-}0.70)x10{sup -3}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid Water as phantom material for dosimetry of electron backscatter using low-energy electron beams: A Monte Carlo evaluation

This study evaluated the dosimetry of electron backscatter when Solid Water is used to substitute water as phantom in electron radiotherapy. Monte Carlo simulation (EGSnrc-based code) was employed to predict electron energy spectra and depth doses for the 0.5 and 1 cm of Solid Water and water slabs above 3 mm of lead (Pb) layers using electron beams with energies of 4 and 6 MeV. For comparison, Monte Carlo simulations were repeated with Pb layers taken out from the phantoms using the same experimental configuration. Analyses on electron energy spectra for the 4 and 6 MeV electron beams showed that deviations of electron energy distributions between the Solid Water and water phantom were more significant in the high-energy range (i.e., close to the maximal electron energy) than the lower range corresponding to the electron backscatter. These deviations of electron energy spectra varied with depth and were mainly due to the electron fluence or beam attenuation. Dosimetry results from Monte Carlo simulations showed that the Solid Water phantom had lower depth dose compared to water with the same experimental setup. For the 4 MeV electron beams with 0.5 cm of Solid Water, depth doses were 1.8%-3.9% and 2.3%-4.4% lower than those in water, with and without the Pb layer underneath, respectively. Thicker Solid Water of 1 cm resulted in different decreases in depth doses of 1.8%-4.6% (with Pb) and 2.3%-4.4% (without Pb) compared to water. For higher nominal electron beam energy of 6 MeV with 0.5 cm of Solid Water, depth doses decreased 1.7%-2.9% (with Pb) and 1.6%-2.1% (without Pb) compared to water. These decreases in depth doses changed to 1.7%-3.7% (with Pb) and 1.7%-3% (without Pb) when the thickness of Solid Water was increased to 1 cm. The dosimetry data in this study are useful in determining the correction factor when using Solid Water to substitute water for the electron backscatter measurement in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy distribution of runaway electrons generated by a nanosecond discharge in atmospheric-pressure air

The spectra of an ultrashort avalanche electron beam generated by a nanosecond discharge in atmospheric-pressure air were investigated. The temporal characteristics of the beam current pulses, gap voltage, and discharge current in a gas diode were measured with a time resolution of {approx}0.1 ns. A simple technique was developed for recovering electron spectra from the curves of beam attenuation by aluminum foils. The effect of the cathode design, electrode gap length, and generator parameters on the electron spectra were studied using seven setups. It is shown that generation of electrons with anomalously high energies requires the use of cathodes with increased curvature radius.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Depth dependence of electron backscatter: An energy spectral and dosimetry study using Monte Carlo simulation

This study investigated the depth dependence of electron backscatter from a layer of lead (Pb) for clinical electron beams. The change in the electron backscatter with variation in the water depth above the Pb was determined. Electron energy spectra and relative depth doses as a function of depth in water over the Pb layer were calculated using a Monte Carlo simulation and studied. Phase-space files for 4 and 9 MeV electron beams (10x10 cm{sup 2} applicator and cutout) based on the Varian 21 EX linear accelerator were generated using the EGSnrc-based BEAMNRC code. 3 mm of Pb, at depths of 0.5 and 1 cm in water, was irradiated with electrons. The source-to-surface distance is equal to 100 cm. Electron energy spectra and relative depth doses with and without the presence of the Pb layer at different depths in water were determined using the BEAMNRC code. For the 4 MeV electron energy spectra at a depth of 0.5 cm in water, electron backscatter was found to originate at the Pb-water interface and extend to 0.5 cm above the Pb insert. However, at a depth of 1 cm in water, electron backscatter almost disappeared at 0.5 and 1 cm above th ePb insert. This is due to the increased attenuation of the incident 4 MeV electron beam in a thicker layer of water as well as increased attenuation of the electron backscatter above the Pb. This resulted in a 23% decrease in relative dose at a measurement point of 0.5 cm depth, when the depth of the Pb insert was changed from 1 to 0.5 cm. For the electron energy spectra of the 9 MeV beams with a 0.5 cm depth of water, only a small amount of electron backscatter was observed. However, more electron backscatter was found when the water depth was increased to 1 cm. This is because the electron beam energy was decreased more due to the increase in attenuation from the increased depth of water compared to 0.5 cm. Since the electron energy spectrum and relative depth dose above the Pb layer vary with depth of water on top of the Pb, the electron backscatter depends significantly on the thickness of water, or water equivalent bolus, or critical tissue over the Pb shield in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Estimates of trapped radiation encountered on low-thrust trajectories through the Van Allen belts

Estimates were made of the number of trapped protons and electrons encountered by vehicles on low-thrust trajectories through the Van Allen belts. The estimates serve as a first step in assessing whether these radiations present a problem to on-board sensitive components and payload. The integrated proton spectra and electron spectra are presented for the case of a trajectory described by a vehicle with a constant-thrust acceleration A sub c equal to 0.001 meter/sq sec. This value of acceleration corresponds to a trip time of about 54 days from low earth orbit to synchronous orbit. It is shown that the time spent in the belts and hence the radiation encountered vary nearly inversely with the value of thrust acceleration. Thus, the integrated spectral values presented for the case of A sub c = 0.001 meter/sq sec can be generalized for any other value of thrust acceleration by multiplying them by the factor 0.001/A sub c.

Karp, I. M.↗

Measurement and Interpretation of Moments in Inclusive Semileptonic Decays B-bar to X_c ell^-

We present results for the moments of observed spectra in inclusive semileptonic B-meson decays to charm hadrons {bar B} {yields} X{sub c} {ell}{sup -}{bar {nu}}. Moments of the hadronic-mass and the combined mass-and-energy spectra for different minimum electron or muon momenta between 0.8 and 1.9 GeV/c are obtained from a sample of 232 x 10{sup 6} {Gamma}(4S) {yields} B{bar B} events, collected with the BABAR detector at the PEP-II asymmetric-energy B-meson factory at SLAC. We also present a reevaluation of the moments of electron-energy spectra and partial decay fractions B({bar B} {yields} X{sub c}e{sup -}{bar {nu}}) for minimum electron momenta between 0.6 and 1.5 GeV/c based on a sample of 51 x 10{sup 6} {Gamma}(4S) {yields} B{bar B} events. The measurements are used for the extraction of the total decay fraction, the Cabibbo-Kobayashi-Maskawa (CKM) matrix element |V{sub cb}|, the quark masses m{sub b} and m{sub c}, and four heavy-quark QCD parameters in the framework of a Heavy-Quark Expansion (HQE). We find B({bar B} {yields} X{sub c}{ell}{sup -}{bar {nu}}) = (10.64 {+-} 0.17 {+-} 0.06)% and |V{sub cb}| = (42.05 {+-} 0.45 {+-} 0.70) x 10{sup -3}.

43 PARTICLE ACCELERATORS↗

Measuring mass of neutrinos with {beta}-decays of tritium and rhenium

Already long time ago the shape of the electron spectrum in {beta}-decays of {sup 3}H and {sup 187}Re has been recognized as an important tool for understanding of neutrino masses. The sensitivity of KATRIN (in preparation, tritium {beta}-decay) and the MARE (under consideration, {sup 187}Re{beta}-decay) experiments to neutrino mass will reach the sub eV domain. In view of this experimental progress there is a request for a highly accurate theoretical description of the electron endpoint spectra. By taking the advantage of the elementary particle treatment of {sup 3}H and {sup 3}He the relativistic form for {beta}-decay endpoint spectrum of tritium is obtained by taking into account also the effect of nuclear recoil. Further, the currently unknown shape of the electron spectrum for the {beta}-decay of {sup 187}Re is presented. It is found that the first forbidden {sup 187}Re(5/2{sup +}){yields}{sup 187}Os(1/2{sup -}){beta}-decay transition is accompanied with emission of mostly p{sub 3/2}-state electrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic Simulations of Solar Type II Radio Burst Emission Processes

Using our kinetic Particle-in-Cell simulation code, we have examined the behavior of different plasma modes in the environment close to a CME shock front, with special focus on the modes that may contribute to the formation of type II radio bursts. Apart from electron velocity spectra, numerical dispersion plots obtained from simulation data allow for analysis of wave modes in the simulated plasma, especially showing growth and damping of these modes over time. These plots reveal features at 2omega{sub p} which are not predicted by linear wave theory, that may be results of nonlinear three wave interaction processes as theoretically predicted for type II emission processes.

79 ASTRONOMY AND ASTROPHYSICS↗