Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The high-power helicon program at DIII-D: gearing up for first experiments

Helicon current drive, also called fast wave current drive in the lower hybrid range of frequencies, has long been regarded as a promising current drive tool for reactor grade plasmas. A newly installed MW-level system at DIII-D will be the first test of this technology in reactor-relevant plasmas, in the sense that full single-pass absorption is expected. A 30-module traveling wave antenna has been installed and optimized in-vessel in early 2020. The linear electromagnetic characteristics of the unloaded module array have been extensively tested both on the bench and in the vessel at instrumentation power levels. Excellent performance has been achieved, ~2% reflected power and ~1.5% dissipated power per module in air, in a 10 MHz band around 476 MHz. Stripline feeds on both ends of the antenna allow either co or counter current drive. The installation of a 1.2 MW klystron and associated high-power electronics was completed in Fall 2020. Commissioning of the antenna is ongoing. An important goal of this experiment is to validate the helicon current drive physics basis using an extensive set of new and upgraded diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SUPERNOVA 2009kf: AN ULTRAVIOLET BRIGHT TYPE IIP SUPERNOVA DISCOVERED WITH PAN-STARRS 1 AND GALEX

We present photometric and spectroscopic observations of a luminous Type IIP Supernova (SN) 2009kf discovered by the Pan-STARRS 1 (PS1) survey and also detected by the Galaxy Evolution Explorer. The SN shows a plateau in its optical and bolometric light curves, lasting approximately 70 days in the rest frame, with an absolute magnitude of M{sub V} = -18.4 mag. The P-Cygni profiles of hydrogen indicate expansion velocities of 9000 km s{sup -1} at 61 days after discovery which is extremely high for a Type IIP SN. SN 2009kf is also remarkably bright in the near-ultraviolet (NUV) and shows a slow evolution 10-20 days after optical discovery. The NUV and optical luminosity at these epochs can be modeled with a blackbody with a hot effective temperature (T {approx} 16,000 K) and a large radius (R {approx} 1 x 10{sup 15} cm). The bright bolometric and NUV luminosity, the light curve peak and plateau duration, the high velocities, and temperatures suggest that 2009kf is a Type IIP SN powered by a larger than normal explosion energy. Recently discovered high-z SNe (0.7 < z < 2.3) have been assumed to be IIn SNe, with the bright UV luminosities due to the interaction of SN ejecta with a dense circumstellar medium. UV-bright SNe similar to SN 2009kf could also account for these high-z events, and its absolute magnitude M{sub NUV} = -21.5 {+-} 0.5 mag suggests such SNe could be discovered out to z {approx} 2.5 in the PS1 survey.

79 ASTRONOMY AND ASTROPHYSICS↗

OBSERVATIONS OF FIVE-MINUTE SOLAR OSCILLATIONS IN THE CORONA USING THE EXTREME ULTRAVIOLET SPECTROPHOTOMETER (ESP) ON BOARD THE SOLAR DYNAMICS OBSERVATORY EXTREME ULTRAVIOLET VARIABILITY EXPERIMENT (SDO/EVE)

We report on the detection of oscillations in the corona in the frequency range corresponding to five-minute acoustic modes of the Sun. The oscillations have been observed using soft X-ray measurements from the Extreme Ultraviolet Spectrophotometer (ESP) of the Extreme Ultraviolet Variability Experiment on board the Solar Dynamics Observatory. The ESP zeroth-order channel observes the Sun as a star without spatial resolution in the wavelength range of 0.1-7.0 nm (the energy range is 0.18-12.4 keV). The amplitude spectrum of the oscillations calculated from six-day time series shows a significant increase in the frequency range of 2-4 mHz. We interpret this increase as a response of the corona to solar acoustic (p) modes and attempt to identify p-mode frequencies among the strongest peaks. Due to strong variability of the amplitudes and frequencies of the five-minute oscillations in the corona, we study how the spectrum from two adjacent six-day time series combined together affects the number of peaks associated with the p-mode frequencies and their amplitudes. This study shows that five-minute oscillations of the Sun can be observed in the corona in variations of the soft X-ray emission. Further investigations of these oscillations may improve our understanding of the interaction of the oscillation modes with the solar atmosphere, and the interior-corona coupling, in general.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation of tunable and broadband far-infrared laser pulses during two-color filamentation

Tunable far-infrared laser pulses were generated efficiently during two-color filamentation in air. Understanding the creation of few-cycle far-infrared laser pulses is important since it is at the frontier between two possible generation mechanisms. The first one is the four-wave mixing generation, associated to the generation of wavelengths from ultraviolet up to mid-infrared laser pulses. The second process is the formation of transient photocurrent, which was recently used to describe the generation of submillimetric (terahertz) waves. Comparison between experiments and simulations revealed that the four-wave mixing mechanism is dominant for the far-infrared generation during two-color filamentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Galileo plasma wave investigation

The purpose of the Galileo plasma wave investigation is to study plasma waves and radio emissions in the magnetosphere of Jupiter. The plasma wave instrument uses an electric dipole antenna to detect electric fields, and two search coil magnetic antennas to detect magnetic fields. The frequency range covered is 5 Hz to 5.6 MHz for electric fields and 5 Hz to 160 kHz for magnetic fields. Low time-resolution survey spectrums are provided by three on-board spectrum analyzers. In the normal mode of operation the frequency resolution is about 10 percent, and the time resolution for a complete set of electric and magnetic field measurements is 37.33 s. High time-resolution spectrums are provided by a wideband receiver. The wideband receiver provides waveform measurements over bandwidths of 1, 10, and 80 kHz. Compared to previous measurements at Jupiter this instrument has several new capabilities. These new capabilities include (1) both electric and magnetic field measurements to distinguish electrostatic and electromagnetic waves, (2) direction finding measurements to determine source locations, and (3) increased bandwidth for the wideband measurements.

Gurnett, D. A.↗

Experimental results of Hooper's gravity-electromagnetic coupling concept

Experiments were conducted to test assertions from Patent 3,610,971, by W.J. Hooper that self-canceling electromagnetic coils can reduce the weight of objects placed underneath. No weight changes were observed within the detectability of the instrumentation. More careful examination of the patent and other reports from Hooper led to the conclusion that Hooper may have misinterpreted thermal effects as his 'Motional Field' effects. There is a possibility that the claimed effects are below the detection thresholds of the instrumentation used for these tests.

Millis, Marc G.↗

Advances in Inner Magnetosphere Passive and Active Wave Research

This review identifies a number of the principal research advancements that have occurred over the last five years in the study of electromagnetic (EM) waves in the Earth's inner magnetosphere. The observations used in this study are from the plasma wave instruments and radio sounders on Cluster, IMAGE, Geotail, Wind, Polar, Interball, and others. The data from passive plasma wave instruments have led to a number of advances such as: determining the origin and importance of whistler mode waves in the plasmasphere, discovery of the source of kilometric continuum radiation, mapping AKR source regions with "pinpoint" accuracy, and correlating the AKR source location with dipole tilt angle. Active magnetospheric wave experiments have shown that long range ducted and direct echoes can be used to obtain the density distribution of electrons in the polar cap and along plasmaspheric field lines, providing key information on plasmaspheric filling rates and polar cap outflows.

Green, James L.↗

Electromagnetic Scattering Analysis of Large Size Asteroids/Comets for Reflection/Transmission Tomography (RTT)

A precise knowledge of the interior structure of asteroids, comets, and Near Earth Objects (NEO) is important to assess the consequences of their impacts with the Earth and develop efficient mitigation strategies. Knowledge of their interior structure also provides opportunities for extraction of raw materials for future space activities. Low frequency radio sounding is often proposed for investigating interior structures of asteroids and NEOs. For designing and optimizing radio sounding instrument it is advantageous to have an accurate and efficient numerical simulation model of radio reflection and transmission through large size bodies of asteroid shapes. In this presentation we will present electromagnetic (EM) scattering analysis of electrically large size asteroids using (1) a weak form formulation and (2) also a more accurate hybrid finite element method/method of moments (FEM/MOM) to help estimate their internal structures. Assuming the internal structure with known electrical properties of a sample asteroid, we first develop its forward EM scattering model. From the knowledge of EM scattering as a function of frequency and look angle we will then present the inverse scattering procedure to extract its interior structure image. Validity of the inverse scattering procedure will be presented through few simulation examples.

Deshpande, Manohar↗

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FABRY-PEROT VERSUS SLIT SPECTROPOLARIMETRY OF PORES AND ACTIVE NETWORK: ANALYSIS OF IBIS AND HINODE DATA

We discuss spectropolarimetric measurements of photospheric (Fe I 630.25 nm) and chromospheric (Ca II 854.21 nm) spectral lines in and around small magnetic flux concentrations, including a pore. Our long-term goal is to diagnose properties of the magnetic field near the base of the corona. We compare ground-based two-dimensional spectropolarimetric measurem ents with (almost) simultaneous space-based slit spectropolarimetry. We address the question of noise and crosstalk in the measurements and attempt to determine the suitability of Ca II measurements with imaging spectropolarimeters for the determination of chromospheric magnetic fields. The ground-based observations were obtained 2008 May 20, with the Interferometric Bidimensional Spectrometer (IBIS) in spectropolarimetric mode operated at the Dunn Solar Telescope at Sunspot, NM. The space observations were obtained with the Spectro-Polarimeter of the Solar Optical Telescope aboard the Japanese Hinode satellite. The agreement between the near-simultaneous co-spatial IBIS and Hinode Stokes-V profiles at 630.25 nm is excellent, with V/I amplitudes compatible to within 1%. The IBIS QU measurements are affected by residual crosstalk from V, arising from calibration inaccuracies, not from any inherent limitation of imaging spectroscopy. We use a Principal Component Analysis to quantify the detected crosstalk. QU profiles with V crosstalk subtracted are in good agreement with the Hinode measurements, but are noisier owing to fewer collected photons. Chromospheric magnetic fields are notoriously difficult to constrain by polarization of Ca II lines alone. However, we demonstrate that high cadence, high angular resolution monochromatic images of fibrils in Ca II and Halpha, seen clearly in IBIS observations, can be used to improve the magnetic field constraints, under conditions of high electrical conductivity. Such work is possible only with time series data sets from two-dimensional spectroscopic instruments such as IBIS, under conditions of good seeing.

79 ASTRONOMY AND ASTROPHYSICS↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASTRO-2 Spacelab Instrument Pointing System mission performance

This paper reports the performance of the Instrument Pointing System (IPS) that flew on the National Aeronautics and Space Administration (NASA) ASTRO-2 Spacelab mission aboard the Space Shuttle Endeavour in March 1995. The IPS provides a stabilizing platform for the ASTRO-2 instrument payload complement that consists of three main experiments (telescopes). The telescopes observe stellar targets in the universe within the ultraviolet portion of the electromagnetic spectrum that must be observed from beyond the earth's atmospheric filtering effects. The three main experiments for observation are the Hopkins Ultraviolet Telescope (HUT), the Ultraviolet Imaging Telescope (UIT), and the Wisconsin Ultraviolet Photo-Polarimetry Experiment (WUPPE). The HUT uses spectroscopy to obtain the structure and chemical makeup of ultraviolet targets. UIT is responsible for wide field photographing to capture the hidden view of the ultraviolet universe. The WUPPE gathers data on the polarization of the ultraviolet electromagnetic energy coming from the astronomical targets. The capability of IPS enables the experiments to 'see' faint celestial objects. A brief explanation of the IPS is given followed by a review of engineering efforts to improve IPS performance over the ASTRO-1 mission. The main focus of improvements was on enhancing the star acquisition capability through improved guide star selection, lab simulations, computer upgrades, data display systems improvements, and software modifications. A star simulator was developed in the lab to enable IPS to be simulated on the ground pre-mission with flight hardware and software in the loop. The paper concludes with results from the ASTRO-2 mission. The number of targets acquired and the IPS pointing accuracy/stability is reported along with recommendations for the future use of the Instrument Pointing System.

Wessling, Francis C., III↗

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tokyo Axion Helioscope

The idea of a magnetic axion helioscope was first proposed by Pierre Sikivie in 1983. Tokyo axion helioscope was built exploiting its detection principle with a dedicated cryogen-free superconducting magnet and PIN photodiodes for x-ray detectors. Solar axions, if exist, would be converted into x-ray photons in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. Its start up, search results so far and prospects are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of polytetrafluoroethylene for xenon scintillation light

Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region ({lambda}{approx_equal}175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗