Reducing quantizer deadband with a range switching digital filter
Digital range switching filter for deadband of analog to digital converter for LSI realization
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Digital range switching filter for deadband of analog to digital converter for LSI realization
Vibration/acoustics environmental testing, discussing advantages of digital computer control system and digital noise generation techniques
Digital data acquisition system with ultrahigh sampling rate for Ames electric arc shock tunnel, describing analog to digital conversion, data storage, system performance, etc
Digital ranging system measures slant range /from 500 feet to 200 nautical miles/ and provides digital range readout during range tracking between any two airborne vehicles.
System combines and modulates subcarriers and pulse code modulation data entirely with digital logic, and phase modulates an RF carrier with a digital representation of the composite subcarrier signal. It permits programmed control and modification of the modulation indices.
Curve generator capable of producing precisely repeatable curve for any single-valued function of voltage versus time uses digital approach, implemented by means of clocked feedback shift register, large scale integrated circuit diode matrix comprising about 12,000 diodes, counter, and digital-to-analog converter.
Digital filters response errors due to signal amplitude quantization, resulting from analog-to- digital conversion and arithmetic operations
Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.
Coded or modulated digital data converts to nonreturn to zero /NRZ/ data. Technique includes logic implementation and pertinent timing diagrams. Demodulation to NRZ facilitates digital logic operations on incoming data. Phase-delay modulation has advantage of inherent self-timing not present in NRZ modulation.
Describing continuous analog to digital converter with parallel digital output and nonlinear feedback
Digital modulator for reshaping partially degraded digital waveforms
Analog inertial sensor digitizing methods, discussing pulse rebalancing and analog to digital conversion
Signal quantization induced low amplitude oscillations in digital control systems, discussing relationship to digital controller programming form
The development of a digital autopilot program for a transport aircraft and the evaluation of that system's performance on a transport aircraft simulator is discussed. The digital autopilot includes three axis attitude stabilization, automatic throttle control and flight path guidance functions with emphasis on the mode progression from descent into the terminal area through automatic landing. The study effort involved a sequence of tasks starting with the definition of detailed system block diagrams of control laws followed by a flow charting and programming phase and concluding with performance verification using the transport aircraft simulation. The autopilot control laws were programmed in FORTRAN 4 in order to isolate the design process from requirements peculiar to an individual computer.
Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.
A design for a solid-state parasitic speed controller using digital logic was analyzed. Parasitic speed controllers are used in space power electrical generating systems to control the speed of turbine-driven alternators within specified limits. The analysis included the performance characteristics of the speed controller and the generation of timing functions. The speed controller using digital logic applies step loads to the alternator. The step loads conduct for a full half wave starting at either zero or 180 electrical degrees.
An iterative procedure is presented for determining the acquisition behavior of discrete or digital implementations of a tracking loop. The technique is based on the theory of Markov chains and provides the cumulative probability of acquisition in the loop as a function of time in the presence of noise and a given set of initial condition probabilities. A digital second-order tracking loop to be used in the Viking command receiver for continuous tracking of the command subcarrier phase was analyzed using this technique, and the results agree closely with experimental data.
The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.