Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

An overview of the thematic mapper geometric correction system

Geometric accuracy specifications for LANDSAT 4 are reviewed and the processing concepts which form the basis of NASA's thematic mapper geometric correction system are summarized for both the flight and ground segments. The flight segment includes the thematic mapper instrument, attitude measurement devices, attitude control, and ephemeris processing. For geometric correction the ground segment uses mirror scan correction data, payload correction data, and control point information to determine where TM detector samples fall on output map projection systems. Then the raw imagery is reformatted and resampled to produce image samples on a selected output projection grid system.

Beyer, E. P.↗

A Scanning Hartmann Focus Test for the EUVI Telescopes aboard STEREO

The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA s Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena like coronal mass ejections. STEREO consists of two nearly identical satellites, each carrying a suite of instruments that provide, among other data, simultaneous images of the Sun. One of these telescopes is the Extreme Ultraviolet Instrument (EUVI). There are two EUVI telescopes, one on each STEREO satellite (EUVI-A and EUVI-B). EUVI is a normal incidence, 98mm diameter, Ritchey-Chretien telescope designed to obtain wide field of view (approx.1deg) images of the Sun at short wavelengths (approx.20nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light from the Sun during an observation. The EUVI is thus four co-aligned, off-axis telescopes. Each off-axis segment on the primary and secondary mirrors has a different extreme ultraviolet coating stack. Furthermore, the aperture select mechanism is synchronized with a filter wheel mechanism near the CCD detector. The EUVI contains no focus mechanism. Models predict that the difference in on-orbit operating temperature and ambient clean room conditions yield a "best focus" difference between integration and operation of approx. 0.2mm.

Ohl, R.↗

Spectral Response and Effective Area Functions of the Hitomi Imaging Instruments

We describe the tools and the underlying methods and principles for generating the spectral response functions for the four imaging instruments that were flown on the Hitomi x-ray astronomy satellite [Soft X-ray Spectrometer, or SXS; Soft X-ray Imager, or SXI, and two Hard X-ray Imagers, or HXI]. In essence, the spectral response function is a temporally and spatially averaged effective area and line-spread-function. For model-fittingx-ray spectra from an instrument, the spectral response function encapsulates the end-to-end physics of the entire system from telescope to detector, and also includes satellite attitude drift, exposure corrections, and in the case of the HXIs, drift in the telescope/detector alignment system. Accuracy in the construction of the spectral response functions is, therefore, critical to maximize the science return from the data.

Yaqoob, Tahir↗

JWST NIRCam Defocused Imaging Photometric Stability Performance and How It Can Sense Mirror Tilts

We use JWST NIRCam short-wavelength photometry to capture a transit lightcurve of the exoplanet HAT-P-14 b to assess performance as part of instrument commissioning. The short-wavelength precision is 152 ppm per 27 s integration as measured over the full time series compared to a theoretical limit of 107 ppm, after corrections to spatially correlated 1/f noise. Persistence effects from charge trapping are well fit by an exponential function with short characteristic timescales, settling on the order of 5–15 minutes. The short-wavelength defocused photometry is also uniquely well suited to measure the real-time wave-front error of JWST. Analysis of the images and reconstructed wave-front maps indicates that two different hexagonal primary mirror segments exhibited “tilt events,” where they changed orientation rapidly in less than ∼1.4 s. In some cases, the magnitude and timing of the flux jumps caused by tilt events can be accurately predicted with a telescope model. These tilt events can be sensed by simultaneous longer-wavelength NIRCam grism spectral images alone in the form of changes to the point-spread function, diagnosed from the full width at half maximum. They can also be sensed with the fine guidance sensor instrument from difference images. Tilt events possibly from sudden releases of stress in the backplane structure behind the mirrors were expected during the commissioning period because they were found in ground-based testing. Tilt events have shown signs of decreasing in frequency but have not disappeared completely. The detectors exhibit some minor (less than 1%) deviations from linear behavior in the first few groups of each integration, potentially impacting absolute fluxes and transit depths on bright targets, where only a handful of groups are possible. Overall, the noise is within 50% of the theoretical photon noise and read noise. This bodes well for high-precision measurements of transiting exoplanets and other time variable targets.

Everett Schlawin↗

Compact Midwave Imaging System: Results from an Airborne Demonstration

The Compact Midwave Imaging System (CMIS) is a wide field of view, multi-angle, multi-spectral push frame imager that relies on the forward motion of the satellite to create a two-dimensional (2D) image swath. An airborne demonstration of CMIS was successfully completed in January-February 2021 on the NASA Langley Research Center Gulfstream III. The primary objective of the four-flight campaign was to demonstrate the capability of this unique instrument to perform stereo observations of clouds and other particulates (e.g. smoke) in the atmosphere. It is shown that the midwave infrared (MWIR) spectral bands of CMIS provide a unique 24/7 capability with high resolution for accurate stereo sensing.The instrument relies on new focal plane array (FPA) technology, which provides excellent sensitivity at much warmer detector temperatures than traditional technologies. This capability enabled a compact, low-cost design that can provide atmospheric motion vectors and cloud heights to support requirements for atmospheric winds in the 2017-2027 Earth Science Decadal Survey. Applications include day/night observations of the planetary boundary layer, severe weather, and wildfires. A comparison with current space-based earth science instruments demonstrates that the SWIR/MWIR multi-spectral capability of CMIS is competitive with larger, more expensive instrumentation. Imagery obtained over a controlled burn and operating nuclear power plant demonstrated the sensitivity of the instrument to temperature variations. The system relies on a mature stereoscopic imaging technique applied to the same scene from two independent platforms to unambiguously retrieve atmospheric motion vectors (AMVs) with accurate height assignment.This capability has been successfully applied to geostationary and low-earth orbit satellites to achieve excellent accuracy. When applied to a ground-point validation case, the accuracy for the CMIS aircraft observations was 20 m and 0.3 m/s for cloud heights and motion vectors, respectively. This result was confirmed by a detailed error analysis with analytical and covariance models. The results for CMIS cases with under flights of Aeolus, CALIPSO and Aqua provided a good validation of expected accuracies. The paper also showed the feasibility of accommodating CMIS on CubeSats to enable multiple instruments to be flown in a leader-follower mode.

stereo winds↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Quantum-enhanced Imaging and Spectroscopy and their Relevance to International Safeguards

As a follow-up to our previous report on quantum sensing for safeguards, here we delve deeper into quantum-enhanced imaging & spectroscopy and address their relevance to international safeguards. Much of the approaches rely on entangled photons, a quantum phenomenon not possible with classical physics, although just correlated photons will work for some applications, such as ghost imaging. We provide a comprehensive survey of quantum approaches, including multiple entangled photon ghost imaging and spectroscopy techniques. Entangled photons for noise reduction are also described, as well as Non-Line-Of-Sight imaging, compressive techniques, and squeezed light. Of particular interest is the generation of entangled photons with large wavelength separation, such as infrared/visible entangled photon pairs. Such entangled pairs would allow interaction with objects in the IR, such as in the molecular “fingerprint” wavelength region, while the recording device captures the visible photons, thus leveraging the high efficiency and lower cost of visible detectors. Unfortunately, entangled x-ray photons are not practical, which would have been useful for safeguards to interrogate shielded materials. Entangled gamma rays are even further beyond reason. We provide our assessment for application of quantum-enhanced imaging & spectroscopy for international safeguards, including suggested improvements to existing IAEA instruments and destructive assay measurements that are done at IAEA lab facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multispectral discrimination of possible Martian surface constituents.

In the 1970s attempts will be made to soft-land scientific instruments on the surface of Mars. The question of the employment of several spectral bands to improve discrimination is investigated. The studies conducted are concerned with the development of a technique for selecting color bands for a lander imaging system. Other study objects include the investigation of certain solid state detectors and the determination of the feasibility of minimizing the total number of telemetry bits from the lander by various means.

Klemas, V.↗

Performance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy

Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.

Dietz, K. L.↗

High Resolution Chemical Study of ALH84001

We have studied the chemistry of a sample of the SNC meteorite ALH84001 using an environmental scanning electron microscope (ESEM) with an energy dispersive chemical analytical detector and a focused ion beam secondary ion mass spectrometer (FIB-SIMS). Here we present the chemical data, both spectra and images, from two techniques that do not require sample preparation with a conductive coating, thus eliminating the possibility of preparation-induced textural artifacts. The FIB-SIMS instrument includes a column optimized for SEM with a quadrupole type mass spectrometer. Its spatial and spectral resolution are 20 nm and 0.4 AMU, respectively. The spatial resolution of the ESEM for chemical analysis is about 100 nm. Limits of detection for both instruments are mass dependent. Both the ESEM and the FIB-SIMS instrument revealed contrasting surficial features; crumbled, weathered appearance of the matrix in some regions as well as a rather ubiquitous presence of euhedral halite crystals, often associated with cracks or holes in the surface of the rock. Other halogen elements present in the vicinity of the NaCl crystals include K and Br. In this report, elemental inventories are shown as mass spectra and as X-ray maps.

Conrad, Pamela G.↗

High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

New Techniques for High-Contrast Imaging with ADI: The ACORNS-ADI SEEDS Data Reduction Pipeline

We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the Strategic Exploration of Exoplanets and Disks (SEEDS) survey. We implement seyeral new algorithms, includbg a method to centroid saturated images, a trimmed mean for combining an image sequence that reduces noise by up to approx 20%, and a robust and computationally fast method to compute the sensitivitv of a high-contrast obsen-ation everywhere on the field-of-view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI is freely available for download at www.github.com/t-brandt/acorns_-adi under a BSD license

Brandt, Timothy D.↗

A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes

Solid-state radiation detectors, using crystalline semiconductors to convert radiation photons to electrical charges, outperform other technologies with high detectivity and sensitivity. Here, we demonstrate a thin-film x-ray detector comprised with highly crystalline two-dimensional Ruddlesden-Popper phase layered perovskites fabricated in a fully depleted p-i-n architecture. It shows high diode resistivity of 10 12 ohm·cm in reverse-bias regime leading to a high x-ray detecting sensitivity up to 0.276 C Gy air –1 cm –3 . Such high signal is collected by the built-in potential underpinning operation of primary photocurrent device with robust operation. The detectors generate substantial x-ray photon–induced open-circuit voltages that offer an alternative detecting mechanism. Furthermore, our findings suggest a new generation of x-ray detectors based on low-cost layered perovskite thin films for future x-ray imaging technologies.

47 OTHER INSTRUMENTATION↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

The Advanced Energetic Pair Telescope (AdEPT}: A Future Medium-Energy Gamma-Ray Balloon (and Explorer?) Mission

Gamma-ray astrophysics probes the highest energy, exotic phenomena in astrophysics. In the medium-energy regime, 0.1-200 MeV, many astrophysical objects exhibit unique and transitory behavior such as the transition from electron dominated to hadron dominated processes, spectral breaks, bursts, and flares. Medium-energy gamma-ray imaging however, continues to be a major challenge particularly because of high background, low effective area, and low source intensities. The sensitivity and angular resolution required to address these challenges requires a leap in technology. The Advance Energetic Pair Telescope (AdEPT) being developed at GSFC is designed to image gamma rays above 5 MeV via pair production with angular resolution of 1-10 deg. In addition AdEPT will, for the first time, provide high polarization sensitivity in this energy range. This performance is achieved by reducing the effective area in favor of enhanced angular resolution through the use of a low-density gaseous conversion medium. AdEPT is based on the Three-Dimensional Track Imager (3-DTI) technology that combines a large volume Negative Ion Time Projection Chamber (NITPC) with 2-D Micro-Well Detector (MWD) readout. I will review the major science topics addressable with medium-energy gamma-rays and discuss the current status of the AdEPT technology, a proposed balloon instrument, and the design of a future satellite mission.

Hunter, Stanley D.↗

Design and Performance of the PALM-3000 3.5 kHz Upgrade

PALM-3000 (P3K), the second-generation adaptive optics (AO) instrument for the 5.1 meter Hale telescope atPalomar Observatory, was released as a facility class instrument in October 2011 and has since been used on-skyfor over 600 nights as a workhorse science instrument and testbed for coronagraph and detector development.In late 2019 P3K underwent a significant upgrade to its wavefront sensor (WFS) arm and real-time control(RTC) system to reinforce its position as a state-of-the-art AO facility and extend its faint-end capability forhigh-resolution imaging and precision radial velocity follow-up of Kepler and TESS targets. The main featuresof this upgrade include an EM-CCD WFS camera capable of 3.5 kHz framerates, and an advanced Digital SignalProcessor (DSP) based RTC system to replace the aging GPU based system. Similar to the pre-upgrade system,the Shack-Hartmann wavefront sensor supports multiple pupil sampling modes using a motorized lenslet stage.The default sampling mode with 64×64 subapertures has been re-commissioned on-sky in late 2019, witha successful return to science observations in November 2019. In 64×mode the upgraded system is alreadyachieving K-band Strehl ratios up to 85% on-sky and can lock on natural guide stars as faint as mV=16. A16×16 subaperture mode is scheduled for on-sky commissioning in Fall 2020 and will extend the system’s faintlimit even further. Here we present the design and on-sky re-commissioning results of the upgraded system,dubbed P3K-II.

Vasisht, Gautam↗