Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crossed hot-wire data acquisition and reduction system

The report describes a system for rapid computerized calibration acquisition, and processing of data from a crossed hot-wire anemometer is described. Advantages of the system are its speed, minimal use of analog electronics, and improved accuracy of the resulting data. Two components of mean velocity and turbulence statistics up to third order are provided by the data reduction. Details of the hardware, calibration procedures, response equations, software, and sample results from measurements in a turbulent plane mixing layer are presented.

Westphal, R. V.↗

The design and instrumentation of the Purdue annular cascade facility with initial data acquisition and analysis

Three dimensional aerodynamic data, required to validate and/or indicate necessary refinements to inviscid and viscous analyses of the flow through turbomachine blade rows, are discussed. Instrumentation and capabilities for pressure measurement, probe insertion and traversing, and flow visualization are reviewed. Advanced measurement techniques including Laser Doppler Anemometers, are considered. Data processing is reviewed. Predictions were correlated with the experimental data. A flow visualization technique using helium filled soap bubbles was demonstrated.

Stauter, R. C.↗

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

Seismic Data Acquisition at the FACT Site for the CASPAR Project

Since May 2010, we have been recording continuous seismic data at Sandia's FACT site. The collected signals provide us with a realistic archive for testing algorithms under development for local monitoring of explosive testing. Numerous small explosive tests are routinely conducted around Kirtland AFB by different organizations. Our goal is to identify effective methods for distinguishing these events from normal daily activity on and near the base, such as vehicles, aircraft, and storms. In this report, we describe the recording system, and present some observations of the varying ambient noise conditions at FACT. We present examples of various common, non-explosive, sources. Next we show signals from several small explosions, and discuss their characteristic features.

58 GEOSCIENCES↗

Data acquisition from high-speed rotating shafts

Data system, when used with a rotary transformer, results in increased life, negligible noise, and capability for a large number of data channels in testing rotating equipment. It is used to multiplex many channels of analog transducer output data and convert this signal to binary digital output.

Lesco, D. J.↗

High rate data acquisition from Spacelab/Shuttle

The need for high data rates from a variety of experiments on Spacelab/Shuttle produced the requirement for the Spacelab High Rate Multiplexer/Demultiplexer system. This system acquires serial digital data at asynchronous bit rates from up to sixteen experiments, two data buses, three voice links, two tape recorders, and a universal time channel. Experiment data rates may vary from 200 bps to 16 Mbps while recorded data rates range from 250 Kbps to 32 Mbps. The High Rate Multiplexer (HRM) accepts these data inputs and forms a serial PCM output at flexible rates up to 48 Mbps. This PCM output is transmitted to ground by a Ku-Band RF link via the Tracking and Data Relay Satellite System (TDRSS) or recorded on board for delayed transmission. A complementary ground based High Rate Demultiplexer (HRDM) accepts and demultiplexes the composite PCM data at ground processing locations.

Coffey, R.↗

Unified Ultrasonic/Eddy-Current Data Acquisition

Imaging station for detecting cracks and flaws in solid materials developed combining both ultrasonic C-scan and eddy-current imaging. Incorporation of both techniques into one system eliminates duplication of computers and of mechanical scanners; unifies acquisition, processing, and storage of data; reduces setup time for repetitious ultrasonic and eddy-current scans; and increases efficiency of system. Same mechanical scanner used to maneuver either ultrasonic or eddy-current probe over specimen and acquire point-by-point data. For ultrasonic scanning, probe linked to ultrasonic pulser/receiver circuit card, while, for eddy-current imaging, probe linked to impedance-analyzer circuit card. Both ultrasonic and eddy-current imaging subsystems share same desktop-computer controller, containing dedicated plug-in circuit boards for each.

Chern, E. James↗

Improving Image Quality and Reducing Drift Problems via Automated Data Acquisition and Averaging in Cs-corrected TEM

Image acquisition with a CCD camera is a single-press-button activity: after selecting exposure time and adjusting illumination, a button is pressed and the acquired image is perceived as the final, unmodified proof of what was seen in the microscope. Thus it is generally assumed that the image processing steps of e.g., 'dark-current correction' and 'gain normalization' do not alter the information content of the image, but rather eliminate unwanted artifacts. Image quality therefore is, among a long list of other parameters, defined by the dynamic range of the CCD camera as well as the maximum allowable exposure time depending on sample drift (ignoring sample damage). Despite the fact that most microscopists are satisfied with present, standard image quality we found that it is a relatively easy to improve on existing routines in at least two aspects: (1) Suppression of lateral image drift during acquisition by using significantly shorter exposure times with a plurality of exposures (3D-data set); and (2) Improvement in the Signal/Noise ratio by averaging over a given data set by exceeding the dynamic range of the camera.

99 GENERAL AND MISCELLANEOUS↗

Accelerating data acquisition with FPGA-based edge machine learning: a case study with LCLS-II

New scientific experiments and instruments generate vast amounts of data that need to be transferred for storage or further processing, often overwhelming traditional systems. Edge machine learning (EdgeML) addresses this challenge by integrating machine learning (ML) algorithms with edge computing, enabling real-time data processing directly at the point of data generation. EdgeML is particularly beneficial for environments where immediate decisions are required, or where bandwidth and storage are limited. In this paper, we demonstrate a high-speed configurable ML model in a fully customizable EdgeML system using a field programmable gate array (FPGA). Our demonstration focuses on an angular array of electron spectrometers, referred to as the ‘CookieBox,’ developed for the Linac Coherent Light Source II project. The EdgeML system captures 51.2 Gbps from a 6.4 GS s −1 analog to digital converter and is designed to integrate data pre-processing and ML inside an FPGA. Our implementation achieves an inference latency of 0.2 µs for the ML model, and a total latency of 0.4 µs for the complete EdgeML system, which includes pre-processing, data transmission, digitization, and ML inference. The modular design of the system allows it to be adapted for other instrumentation applications requiring low-latency data processing.

97 MATHEMATICS AND COMPUTING↗

Analog Input Data Acquisition Software

DAQ Master Software allows users to easily set up a system to monitor up to five analog input channels and save the data after acquisition. This program was written in LabVIEW 8.0, and requires the LabVIEW runtime engine 8.0 to run the executable.

Arens, Ellen↗

An assessment of LANDSAT data acquisition history on identification and area estimation of corn and soybeans

Multitemporally registered LANDSAT MSS data from four acquisitions during the 1978 growing season were used in classification of eight sample segments in Iowa and Indiana. The results illustrate that use of LANDSAT acquisition when corn has tasseled is critical, as this is the optimum time for separation of corn and soybeans. An early season acquisition when the summer crops appear as bare soil can be beneficial in reducing the confusion between these two crops and other cover types. A subset of one visible and one infrared band from each date was found to produce results not significantly different from the use of all bands. Selection of a subset of these bands may also be feasible for multitemporal analysis.

Hixson, M. M.↗