Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DRIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Ionospheric drifts

Program to measure horizontal drifts in lower and upper ionospheres

UPPER IONOSPHERE↗

Amplifier drift tester

Automatic measurement of gain and zero drift characteristics of dc amplifier

TEST EQUIPMENT↗

Ground Calibration of the Silicon Drift Detectors for NICER

The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the e ort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either 55Fe, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors.

Silicon Drift Detectors↗

Calibrating ground‐based microwave radiometers: Uncertainty and drifts

Abstract The quality of microwave radiometer (MWR) calibrations, including both the absolute radiometric accuracy and the spectral consistency, determines the accuracy of geophysical retrievals. The Microwave Radiometer Calibration Experiment (MiRaCalE) was conducted to evaluate the performance of MWR calibration techniques, especially of the so‐called Tipping Curve Calibrations (TCC) and Liquid Nitrogen Calibrations (LN2cal), by repeatedly calibrating a fourth‐generation Humidity and Temperature Profiler (HATPRO‐G4) that measures downwelling radiance between 20 GHz and 60 GHz. MiRaCalE revealed two major points to improve MWR calibrations: (i) the necessary repetition frequency for MWR calibration techniques to correct drifts, which ensures stable long‐term measurements; and (ii) the spectral consistency of control measurements of a well known reference is useful to estimate calibration accuracy. Besides, we determined the accuracy of the HATPRO's liquid nitrogen‐cooled blackbody's temperature. TCCs and LN2cals were found to agree within 0.5 K when observing the liquid nitrogen‐cooled blackbody with a physical temperature of 77 K. This agreement of two different calibration techniques suggests that the brightness temperature of the LN2 cooled blackbody is accurate within at least 0.5 K, which is a significant reduction of the uncertainties that have been assumed to vary between 0.6 K and 1.5 K when calibrating the HATPRO‐G4. The error propagation of both techniques was found to behave almost linearly, leading to maximum uncertainties of 0.7 K when observing a scene that is associated with a brightness temperature of 15 K.

Küchler, N.↗

Incorporating Electrochemical Halide Oxidation into Drift-Diffusion Models to Explain Performance Losses in Perovskite Solar Cells under Prolonged Reverse Bias

Partial shading of a solar module can induce a set of cells within the module to operate under reverse bias. Studies have shown that metal halide perovskite solar cells with a wide variety of compositions and contacts exhibit interesting behavior in reverse bias that includes both reversible performance loss and non-reversible degradation. In this paper, an advanced drift-diffusion approach incorporating an electrochemical term to explain the short-circuit, open circuit and fill factor losses that are experimentally measured after prolonged reverse bias is used. It is shown that holes can tunnel into the perovskite due to sharp band bending near the contact, accumulate within the bulk of the perovskite absorber, and trigger the oxidation of halides to form neutral halogens. The density of neutral halogens is much higher in reverse bias because there are hardly any electrons available to reduce the iodine. The resulting halogens act as bulk recombination centers. While the interstitial halogen density does decay when the cell is operated in forward bias, permanent degradation can occur if the iodine diffuses out of the perovskite layer. Finally, the ways in which changing parameters such as the mobile ion density or the series resistance at the contact can influence device performance and stability are discussed.

degradation↗