Coolant delivery via an independent cooling circuit

A coolant delivery system for a component of a gas turbine system includes: a plurality of independent circuits of cooling channels embedded within an exterior wall of the component, each independent circuit of cooling channels including a plurality of headers and a plurality of feed tubes fluidly coupling the plurality of headers to a supply of cooling fluid; and an impingement plate connected to the exterior wall of the component by the plurality of feed tubes of the independent circuits of cooling channels, wherein, in each of the plurality of independent circuits of cooling channels, the cooling fluid flows through the plurality of feed tubes and the plurality of headers into the circuit of cooling channels only in response to a formation of a breach in the exterior wall of the component that exposes at least one of the cooling channels of the circuit of cooling channels.

Hafner, Matthew Troy↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The characteristic of evaporative cooling magnet for ECRIS

Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm{sup 2}. On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermally Effective and Efficient Cooling Technologies for Advanced Gas Turbine Systems

This report presents the research which has been undertaken under DOE grant DE-FE-0011875 as part of NETL’s UTSR (University Turbine System Research) Program. The experimental portion of this work was undertaken at the University of North Dakota (UND) under the direction of Dr. Forrest Ames. The computational work was undertaken at LSU (Louisiana State University), UM (University of Memphis), and at IIT (Illinois Institute of Technology) under the direction of Dr. Sumanta Acharya. The research program was organized into a four phase program which included: 1) development of a FDA/FEA (finite difference analysis/finite element analysis) cooling model, 2) experimental/computational investigation of appropriate internal cooling methods, 3) experimental/computational investigation of external heat transfer and film cooling, 4) development of an enhanced FDA/FEA model along with the development of a warm cascade test for comparison purposes. The experimental work at UND included research on both internal cooling methods and external heat transfer. The internal cooling work included the design and testing of multiple variable hole-size “incremental impingement” configurations along with testing of two converging rounded diamond pedestal arrays for the trailing edge region. The external heat transfer work included the building of a large scale cascade facility to test a vane design with a large leading edge and an aft loaded suction surface. UND has acquired both midspan and full suction surface heat transfer measurements as well as prepared for film cooling measurements under the grant. LSU/UM/IIT has developed and conducted wall resolved LES computations for the incremental impingement geometries and provided rational understanding of the effect of hole sizes and their distributions. Additionally they have provided design correlations for the incremental impingement heat transfer coefficients. They have also developed LES methods to predict flow through film cooling plenums, which have pedestals along with the development of slot film cooling downstream from the plenums. Additionally, they have developed wall resolved LES to predict vane surface heat transfer including bypass transition without the use of a transition model. Through these simulations they provide understanding of the aerodynamic and surface heat transfer behavior under a range of influences such as freestream turbulence. The present study has produced some very useful research outcomes.

01 COAL, LIGNITE, AND PEAT↗

Challenges and Opportunities in Gen3 Embedded Cooling with High-Quality Microgap Flow

Gen3, Embedded Cooling, promises to revolutionize thermal management of advanced microelectronic systems by eliminating the sequential conductive and interfacial thermal resistances which dominate the present 'remote cooling' paradigm. Single-phase interchip microfluidic flow with high thermal conductivity chips and substrates has been used successfully to cool single transistors dissipating more than 40kW/sq cm, but efficient heat removal from transistor arrays, larger chips, and chip stacks operating at these prodigious heat fluxes would require the use of high vapor fraction (quality), two-phase cooling in intra- and inter-chip microgap channels. The motivation, as well as the challenges and opportunities associated with evaporative embedded cooling in realistic form factors, is the focus of this paper. The paper will begin with a brief review of the history of thermal packaging, reflecting the 70-year 'inward migration' of cooling technology from the computer-room, to the rack, and then to the single chip and multichip module with 'remote' or attached air- and liquid-cooled coldplates. Discussion of the limitations of this approach and recent results from single-phase embedded cooling will follow. This will set the stage for discussion of the development challenges associated with application of this Gen3 thermal management paradigm to commercial semiconductor hardware, including dealing with the effects of channel length, orientation, and manifold-driven centrifugal acceleration on the governing behavior.

microchannel↗

Coherent electron cooling

Cooling intense high-energy hadron beams remains a major challenge in modern accelerator physics. Synchrotron radiation is still too feeble, while the efficiency of two other cooling methods, stochastic and electron, falls rapidly either at high bunch intensities (i.e. stochastic of protons) or at high energies (e-cooling). In this talk a specific scheme of a unique cooling technique, Coherent Electron Cooling, will be discussed. The idea of coherent electron cooling using electron beam instabilities was suggested by Derbenev in the early 1980s, but the scheme presented in this talk, with cooling times under an hour for 7 TeV protons in the LHC, would be possible only with present-day accelerator technology. This talk will discuss the principles and the main limitations of the Coherent Electron Cooling process. The talk will describe the main system components, based on a high-gain free electron laser driven by an energy recovery linac, and will present some numerical examples for ions and protons in RHIC and the LHC and for electron-hadron options for these colliders. BNL plans a demonstration of the idea in the near future.

43 PARTICLE ACCELERATORS↗

Investigation of Effects of SiO{sub 2} Content and Cooling Rate on Crystallization in Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} System Using In Situ Confocal Laser Scanning Microscopy

The crystallization behaviors of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system in a non-equilibrium state with various chemical compositions and cooling rates were investigated by confocal laser scanning. Equilibrium samples were prepared in melt states and cooled at a rate of 1 K/min to produce samples in quasi-equilibrium states. The effect of SiO{sub 2} on the phase constitution was investigated using Image Analyzer, and the changes of the phase ratios were analyzed using activity values of Fe{sub 2}O{sub 3} calculated using FactSage 7.1. The Continuous cooling transformation diagram of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system was obtained for various cooling rates. The temperatures at which the primary phase formed for various SiO{sub 2} contents and cooling rates differed from the equilibrium temperatures, and the phase-formation temperature ranges varied with the cooling rate. In addition, the reduction degree of each sample was measured to determine the effect of SiO{sub 2} content and cooling rate on the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system. The reduction degree in the FeO{sub 3}-CaO-SiO{sub 2} system is dominantly influenced by the SiO{sub 2} bond-phase morphology (CF, C{sub 2}S, C{sub 3}S, or glass) rather than the cooling rate.

36 MATERIALS SCIENCE↗

Pressure effects on reactivity and extinction of n -dodecane diffusion cool flame

Low-temperature combustion at high pressure has gained increasing interest owing to the growing demand for clean and efficient propulsion and energy systems. In particular, cool flame structure, extinction limits, and fuel reactivities at high pressure are critical in affecting the engine performance at near-limit conditions. Here, this paper investigates the effects of pressure on the cool flame extinction limit, structure, radical index, reactivity, and oxygen concentration dependence by experiments, analysis, and modeling. A large n-alkane, namely n-dodecane (n C 12 H 26 ), is selected to study its diffusion cool flame dynamics and reactivity in a high-pressure counterflow burner up to 10 atm. The experimental results show that higher pressure increases the cool flame extinction strain rates, and that the pressure-weighted extinction strain rate (aP) is proportional to the square of pressure, P 2 . A scaling analysis explains the relationship between the dependence of flame structure, heat release rate, and pressure-weighted cool flame strain rate on pressure. Furthermore, radical indexes at different pressures are measured by isolating the thermal and transport effects from the chemical contribution to diffusion cool flame extinction. The radical index clearly shows that the low-temperature reactivity increases with pressure. In addition, due to the critical role of multiple oxygen addition reactions in low-temperature chemistry, the relationship between the cool flame extinction limit and the oxygen concentration is explored. It is found that the cool flame extinction limits are proportional to the n th power of the oxygen concentration, [O 2 ] n , and increasing pressure leads to stronger extinction limit dependence (larger n) on the oxygen concentration. The present experiment and detailed kinetic analysis show clearly that increasing pressure promotes the low-temperature chemistry including the oxygen addition reactions, while the scaling analysis explains well the experimental results.

33 ADVANCED PROPULSION SYSTEMS↗

Cooling load forecasting-based predictive optimisation for chiller plants

Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Rather than minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a topology analysis tool for fifth-generation district heating and cooling networks

Fifth generation district heating and cooling networks are characterized by supply temperatures in the ambient range of 15-25 degrees C, which not only reduces heat loss but also allows for integrating various kinds of low-temperature waste heat sources. The ability of these networks to absorb waste heat that is normally unrecoverable makes them an attractive solution for the future energy supply of urban areas. To enhance the adoption of these networks, this paper describes the development of a software tool to analyze the feasibility of fifth-generation of district heating and cooling systems in both new and existing districts. The research attempts to answer the question: 'Which buildings should be connected to a low-temperature hydraulic network given both the incremental benefits and costs relative to the scenario of decentralized (dedicated) heating and cooling systems for each building?' Therefore, all possible network layouts of the buildings are considered where the heating and cooling demands of each building are met by the fifth-generation of district heating and cooling network. For the heating and cooling load characterization of the buildings, reduced-order models are used while renewable energy and waste heat sources are included in the network. The focus of the research lies in the development of a hydraulic model for flexible use in the urban energy modeling and the optimization of the fifth-generation of district heating and cooling network topology for a given urban district. This research displays simulation results that quantify the performance of the fifth-generation of district heating and cooling network based on various output metrics, including primary energy usage, carbon dioxide emissions, and network implementation cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-time optimization of multi-cell industrial evaporative cooling towers using machine learning and particle swarm optimization

Existing electrical generating stations must operate with greater flexibility due to increasing renewable energy penetration on the electrical grid, and many coal-fired power stations have transitioned away from baseload operation to load-following operation to aid in grid stability. In cases where multiple independently controlled cooling tower cells are used in parallel for the cooling purposes of such stations, there is an opportunity to increase plant efficiency through data-driven optimization across their full load ranges. This work presents a novel application of real-time optimization using machine learning and particle swarm optimization on a multi-cell induced-draft cooling tower servicing a coal-fired power station under variable load. This is the first work to demonstrate simultaneous optimization of a multi-cell cooling tower, in addition to using machine learning for closed-loop control on a cooling tower. A novel control configuration is presented that ensures original control logic is not adversely affected and that the overall plant process is not disrupted using only existing hardware and operational data. To verify this methodology, the 12 independent cooling tower cells are simulated in parallel using historic operating data to demonstrate the effectiveness of real-time optimization compared to current practice. An artificial neural network is trained to predict overall cooling tower power consumption using only operational data and ambient conditions with an R2 value of greater than 0.96. The real-time optimization using particle swarm yields 6.7% annual energy usage savings compared to current practices, although the extent of the real-time savings varies greatly with both plant load and environmental conditions. This is particularly significant for a variable load situation because frequent ramping typically results in reduced overall efficiency. Furthermore, this proposed AI-based solution presents an opportunity to improve the overall heat rate of a load-following coal-fired power plant without the need to perform extensive first-principles modeling or add additional hardware to the cooling tower, resulting in more resources conserved and less overall emissions per unit of electricity generated.

42 ENGINEERING↗

Eco-friendly passive radiative cooling using recycled packaging plastics

Passive daytime radiative cooling, requiring zero external energy consumption, is a promising cooling strategy achieved by simultaneously reflecting solar irradiance and thermally radiating heat into the cold outer space (~3 K) through the atmospheric transparency window. However, current materials for passive radiative cooling face huge challenges, such as complicated fabrication approaches, expensive raw materials, and environmental requirements for practical applications. In line with the urgent need for plastic recycling to curb global environmental pollution, the recycled plastics are used to fabricate a passive radiative cooling material. Herein, the foam-paper composite (FPC) with excellent self-cooling capability is fabricated by a simple crushing-and-mixing procedure using recycled polystyrene (PS) foam and printer paper. The superhydrophobic PS foam particles not only protect the FPC from water damage for field applications but also reinforce its solar reflectivity via their porous structure. The cellulose fibers in printer paper can efficiently emit infrared thermal radiation into the cold outer space and bond dispersed PS foam particles together, further increasing its mechanical strength. The combination of highly diffusely reflective PS foam particles and fiber-based printer paper results in a reflectivity of 96% in the solar spectrum, a sub-ambient cooling performance of 8.4 degrees C, and a maximum radiative cooling power of 90 W/m2 during a 24-h cycle. Meanwhile, the FPC with high humidity can maintain its high solar reflectivity, which promotes its application in humid subtropical areas. Further, the low material cost and ease of fabrication will provide a path for effective daytime radiative cooling, especially in less developed areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative study of different solar cooling systems for buildings in subtropical city

In recent years, more and more attention has been paid on the application potential of solar cooling for buildings. Due to the fact that the efficiency of solar collectors is generally low at the time being, the effectiveness of solar cooling would be closely related to the availability of solar irradiation, climatic conditions and geographical location of a place. In this paper, five types of solar cooling systems were involved in a comparative study for subtropical city, which is commonly featured with long hot and humid summer. The solar cooling systems included the solar electric compression refrigeration, solar mechanical compression refrigeration, solar absorption refrigeration, solar adsorption refrigeration and solar solid desiccant cooling. Component-based simulation models of these systems were developed, and their performances were evaluated throughout a year. The key performance indicators are solar fraction, coefficient of performance, solar thermal gain, and primary energy consumption. In addition, different installation strategies and types of solar collectors were compared for each kind of solar cooling system. Through this comparative study, it was found that solar electric compression refrigeration and solar absorption refrigeration had the highest energy saving potential in the subtropical Hong Kong. The former is to make use of the solar electric gain, while the latter is to adopt the solar thermal gain. These two solar cooling systems would have even better performances through the continual advancement of the solar collectors. It will provide a promising application potential of solar cooling for buildings in the subtropical region. (author)

14 SOLAR ENERGY↗

Ice Thermal Storage Systems for Nuclear Power Plant Supplemental Cooling and Peak Power Shifting

Availability of cooling water has been one of the major issues for the nuclear power plant site selection. Cooling water issues have frequently disrupted the normal operation at some nuclear power plants during heat waves and long draught. One potential solution is to use ice thermal storage (ITS) systems that reduce cooling water requirements and boost the plant’s thermal efficiency in hot hours. ITS uses cheap off-peak electricity to make ice and uses the ice for supplemental cooling during peak demand time. ITS also provides a way to shift a large amount of electricity from off peak time to peak time. For once-through cooling plants near a limited water body, adding ITS can bring significant economic benefits and avoid forced derating and shutdown during extremely hot weather. For the new plants using dry cooling towers, adding the ITS systems can effectively reduce the efficiency loss during hot weather so that new plants could be considered in regions lack of cooling water. This paper will review light water reactor cooling issues and present the feasibility study results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cryogenic performance of a conduction-cooling splittable quadrupole magnet for ILC cryomodules

A conduction-cooled splittable superconducting quadrupole magnet was designed and fabricated at Fermilab for use in cryomodules of the International Linear Collider (ILC) type, in which the magnet was to be assembled around the beam tube to avoid contaminating the ultraclean superconducting radio frequency cavity volume. This quadrupole was first tested in a liquid helium bath environment at Fermilab, where its quench and magnetic properties were characterized. Because the device is to be cooled by conduction when installed in cryomodules, a separate test with a conduction-cooled configuration was planned at KEK and Fermilab. The magnet was converted to a conduction-cooled configuration by adding conduction-cooling passages made of high-purity aluminum. Efforts to convert and refabricate the magnet into a cryostat equipped with a double-stage pulse-tube-type cryocooler began in 2011, and a thermal performance test, including a magnet excitation test of up to 30 A, was conducted at KEK. In this test, the magnet with the conduction-cooled configuration was successfully cooled to 4 K within 190 h, with an acceptable heat load of less than 1 W at 4 K. It was also confirmed that the conduction-cooled splittable superconducting quadrupole magnet was practical for use in ILC-type cryomodules.

43 PARTICLE ACCELERATORS↗

Radiative sky cooling: Fundamental principles, materials, and applications

Radiative sky cooling cools an object on the earth by emitting thermal infrared radiation to the cold universe through the atmospheric window (8–13 μm). It consumes no electricity and has great potential to be explored for cooling of buildings, vehicles, solar cells, and even thermal power plants. Radiative sky cooling has been explored in the past few decades but limited to nighttime use only. Very recently, owing to the progress in nanophotonics and metamaterials, daytime radiative sky cooling to achieve subambient temperatures under direct sunlight has been experimentally demonstrated. More excitingly, the manufacturing of the daytime radiative sky cooling material by the roll-to-roll process makes large-scale deployment of the technology possible. This work reviews the fundamental principles of radiative sky cooling as well as the recent advances, from both materials and systems point of view. Potential applications in different scenarios are reviewed with special attention to technology viability and benefits. As the energy situation and environmental issues become more and more severe in the 21st century, we conclude radiative sky cooling can be explored for energy saving in buildings and vehicles, mitigating the urban heat island effect, resolving water and environmental issues, achieving more efficient power generation, and even fighting against the global warming problem.

Energy efficiency↗

THE EFFECT OF ENVIRONMENT ON THE FORMATION OF H{alpha} FILAMENTS AND COOL CORES IN GALAXY GROUPS AND CLUSTERS

We present the results of a combined X-ray and H{alpha} study of 10 galaxy groups and 17 galaxy clusters using the Chandra X-ray Observatory and the Maryland Magellan Tunable Filter. We find no difference in the morphology or detection frequency of H{alpha} filaments in groups versus clusters over the mass range 10{sup 13} < M{sub 500} < 10{sup 15} M{sub sun}. The detection frequency of H{alpha} emission is shown to be only weakly dependent on the total mass of the system at the 52% confidence level. In contrast, we find that the presence of H{alpha} filaments is strongly correlated with both the global (89% confidence level) and core (84%) intracluster medium (ICM) entropy, as well as the X-ray cooling rate (72%). The H{alpha} filaments are therefore an excellent proxy for the cooling ICM. The H{alpha} filaments are more strongly correlated with the cooling properties of the ICM than with the radio properties of the brightest cluster galaxy; this further supports the scenario where these filaments are directly associated with a thermally unstable, rapidly cooling ICM, rather than radio bubbles. The ICM cooling efficiency, defined as the X-ray cooling rate per unit gas mass, is shown to correlate with the total system mass, indicating that groups are more efficient at cooling than clusters. This result implies that, in systems with cool cores, active galactic nucleus feedback scales with the total mass of the system, in agreement with earlier suggestions.