Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its 'dialed in' value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

43 PARTICLE ACCELERATORS↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its “dialed in” value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Average subentropy, coherence and entanglement of random mixed quantum states

Compact expressions for the average subentropy and coherence are obtained for random mixed states that are generated via various probability measures. Surprisingly, our results show that the average subentropy of random mixed states approaches the maximum value of the subentropy which is attained for the maximally mixed state as we increase the dimension. In the special case of the random mixed states sampled from the induced measure via partial tracing of random bipartite pure states, we establish the typicality of the relative entropy of coherence for random mixed states invoking the concentration of measure phenomenon. Our results also indicate that mixed quantum states are less useful compared to pure quantum states in higher dimension when we extract quantum coherence as a resource. This is because of the fact that average coherence of random mixed states is bounded uniformly, however, the average coherence of random pure states increases with the increasing dimension. As an important application, we establish the typicality of relative entropy of entanglement and distillable entanglement for a specific class of random bipartite mixed states. In particular, most of the random states in this specific class have relative entropy of entanglement and distillable entanglement equal to some fixed number (to within an arbitrary small error), thereby hugely reducing the complexity of computation of these entanglement measures for this specific class of mixed states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new coherent demodulation technique for land-mobile satellite communications

An advanced coherent demodulation technique is described for land mobile satellite (LMS) communications. The proposed technique features a combined narrow/wind band dual open loop carrier phase estimator, which is effectively able to compensate the fast carrier phase fluctuation by fading with sacrificing a phase slip rate. Also included is the realization of quick carrier and clock reacquisition after shadowing by taking open loop structure. Its bit error rate (BER) performance is superior to that of existing detection schemes, showing a BER of 1 x 10(exp -2) at 6.3 dB E sub b/N sub o over the Rician channel with 10 dB C/M and 200 Hz (1/16 modulation rate) fading pitch f sub d for QPSK. The proposed scheme consists of a fast response carrier recovery and a quick bit timing recovery with an interpolation. An experimental terminal model was developed to evaluate its performance at fading conditions. The results are quite satisfactory, giving prospects for future LMS applications.

Yoshida, Shousei↗

Aligning Arrays of Lenses and Single-Mode Optical Fibers

A procedure now under development is intended to enable the precise alignment of sheet arrays of microscopic lenses with the end faces of a coherent bundle of as many as 1,000 single-mode optical fibers packed closely in a regular array (see Figure 1). In the original application that prompted this development, the precise assembly of lenses and optical fibers serves as a single-mode spatial filter for a visible-light nulling interferometer. The precision of alignment must be sufficient to limit any remaining wavefront error to a root-mean-square value of less than 1/10 of a wavelength of light. This wavefront-error limit translates to requirements to (1) ensure uniformity of both the lens and fiber arrays, (2) ensure that the lateral distance from the central axis of each lens and the corresponding optical fiber is no more than a fraction of a micron, (3) angularly align the lens-sheet planes and the fiber-bundle end faces to within a few arc seconds, and (4) axially align the lenses and the fiber-bundle end faces to within tens of microns of the focal distance. Figure 2 depicts the apparatus used in the alignment procedure. The beam of light from a Zygo (or equivalent) interferometer is first compressed by a ratio of 20:1 so that upon its return to the interferometer, the beam will be magnified enough to enable measurement of wavefront quality. The apparatus includes relay lenses that enable imaging of the arrays of microscopic lenses in a charge-coupled-device (CCD) camera that is part of the interferometer. One of the arrays of microscopic lenses is mounted on a 6-axis stage, in proximity to the front face of the bundle of optical fibers. The bundle is mounted on a separate stage. A mirror is attached to the back face of the bundle of optical fibers for retroreflection of light. When a microscopic lens and a fiber are aligned with each other, the affected portion of the light is reflected back by the mirror, recollimated by the microscopic lens, transmitted through the relay lenses and the beam compressor/expander, then split so that half goes to a detector and half to the interferometer. The output of the detector is used as a feedback control signal for the six-axis stage to effect alignment.

Liu, Duncan↗

Laser Frequency Stabilization for Coherent Lidar Applications using Novel All-Fiber Gas Reference Cell Fabrication Technique

Compact hollow-core photonic crystal fiber (HC-PCF)gas frequency reference cell was constructed using a novel packaging technique that relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers. The use of this gas cell for laser frequency stabilization was demonstrated by locking a tunable diode laser to the center of the P9 line from the (nu)1+(nu)3 band of acetylene with RMS frequency error of 2.06 MHz over 2 hours. This effort was performed in support of a task to miniaturize the laser frequency stabilization subsystem of JPL/LMCT Laser Absorption Spectrometer (LAS) instrument.

Laser Absorption Spectrometer (LAS)↗

Earth Observation from Space - The Issue of Environmental Sustainability

Remote sensing scientists work under assumptions that should not be taken for granted and should, therefore, be challenged. These assumptions include the following: 1. Space, especially Low Earth Orbit (LEO), will always be available to governmental and commercial space entities that launch Earth remote sensing missions. 2. Space launches are benign with respect to environmental impacts. 3. Minimization of Type 1 error, which provides increased confidence in the experimental outcome, is the best way to assess the significance of environmental change. 4. Large-area remote sensing investigations, i.e. national, continental, global studies, are best done from space. 5. National space missions should trump international, cooperative space missions to ensure national control and distribution of the data products. At best, all of these points are arguable, and in some cases, they're wrong. Development of observational space systems that are compatible with sustainability principles should be a primary concern when Earth remote sensing space systems are envisioned, designed, and launched. The discussion is based on the hypothesis that reducing the environmental impacts of thedata acquisition step,which is at the very beginning of the information streamleading to decision and action, will enhance coherence in the information streamand strengthen the capacity of measurement processes to meet their stated functional goal, i.e. sustainable management of Earth resources. We suggest that unconventional points of view should be adopted and when appropriate, remedial measures considered that could help to reduce the environmental footprint of space remote sensing and of Earth observation and monitoring systems in general. This article discusses these five assumptions inthe contextof sustainablemanagementof Earth's resources. Takingeachassumptioninturn,we find the following: (1) Space debris may limit access to Low Earth Orbit over the next decades. (2) Relatively speaking, given that they're rare event, space launches may be benign, but study is merited on upper stratospheric and exospheric layers given the chemical activity associated with rocket combustion by-products. (3) Minimization of Type II error should be considered in situations where minimization of Type I error greatly hampers or precludes our ability to correct the environmental condition being studied. (4) In certain situations, airborne collects may be less expensive and more environmentally benign, and comparative studies should be done to determine which path is wisest. (5) International cooperation and data sharing will reduce instrument and launch costs and mission redundancy. Given fiscal concerns of most of the major space agencies e e.g. NASA, ESA, CNES e it seems prudent to combine resources.

Earth observation systems↗

Absorber height effects on SWA restrictions and 'Shadow' LER

As extreme-ultraviolet lithography (EUVL) approaches introduction at the 22-nm half-pitch node, several key aspects of absorber height effects remain unexplored. In particular, sidewall angle (SWA) restrictions based on the height of the mask absorber has not yet been clearly defined. In addition, the effects of absorber height on line-edge roughness (LER) from shadowing has not been examined. We make an initial investigation into how tight SWA constraints are and the extent to which shadow LER alters basic LER. Our approach to SWA aims to find SWA restrictions based on 10% of the total CD error budget (10% of CD). Thus, we allot the SWA budget a {+-}0.2nm tolerance for 22nm half-pitch. New with EUVL is the off-axis illumination system. One potential pitfall that must be carefully monitored is the effect of mask absorber height blocking light from reaching, and therefore, correctly detecting, the base edge position of a feature. While mask features can correctly compensate sizing to target at the wafer, the effects of this shadowing on LER have not yet been investigated. Specifically, shadow LER may exacerbate or mitigate the inherent LER on the mask. Shadowing may also cause a difference in the observed LER on the right and left side of the features. We carefully probe this issue for a range of spatial frequencies. We do rigorous aerial image modeling of mask features with a nominal SWA of 80 degrees and correctly sized to target 22nm features measured at the top, 70nm TaN absorber on a 40 bilayer ML mirror with a 2.5nm Ru cap. Simulations were on a 4X system with an ideal pupil of NA = 0.32, illumination wavelength 13.4nm at 6{sup o} off-axis, and disk source shape with partial coherence factor of {sigma} = 0.50. We first implement a defocus offset to the aerial image so that best focus lies at a nominal zero defocus value. We then calculate the depth of focus (DOF) for which the image-log-slope (ILS) delivers a contrast is greater than 50%, an arbitrary standard for a good quality photoresist to print. Using this DOF, we optimize the process window and adjust the intensity threshold from it's nominal value to a new optimal value. From this optimized intensity threshold, we calculated the aerial image CD through focus for a range of angles around the nominal SWA value. From this, we can find out how much the SWA needs to be constrained by in order to keep the {+-}10% CD error budget tolerance required. For SWA of 80 degrees, we found the nominal SWA is tightly constrained by 0.5 degrees. We repeated these calculations for other nominal values of SWA 85 and 88 degrees, and found that CD sensitivity to nominal SWA is relatively independent. In examining shadow LER, we use FDTD simulations to obtain a rigorous solution for the source intensity immediately after the patterned TaN mask absorber pattern on a 2.5nm Ru capped 40 bilayer ML mirror. The optical system was comprised of an ideal pupil map, NA = 0.32, 13.4nm light at 4{sup o} off-axis, and annular source shape with partial coherence factor of {sigma} = 0.35-0.55. We assumed a 90{sup o} SWA. For the basic 2D shape of the mask that we exactly replicated through height, we created mask LER by generating a sine wave of full amplitude 4nm, equivalent to 4nm LER, (wafer dim.), confined along it's length to precisely CD=22nm, for sine waves with spatial frequencies (full period) of 25, 50, 75, 100, 125, 150, 175, and 200nm (wafer dim.), and illuminated at both {phi}=0{sup o} (perpendicular, shadowing) and {phi}=90{sup o} (parallel, no shadowing). Results show that even off-axis illumination perpendicular to the lines and spaces gives minimal difference between the left and right LER to at most 0.1nm difference at best focus. We followed up this study by repeating the data for a mask designed with 2nm LER with similar results. A plot of the transfer functions for LER of both 2nm and 4nm compared to the contrast of simple 50% duty cycle lines and spaces shows that LER has a unique transfer function as well as a linear response to LER amplitude. In the course of our investigation of SWA, we found that the nominal angle has no effect on process window size, and neither does sensitivity on changing angle alter as a function of nominal angle. For nominal 80{sup o}, 85{sup o}, 88{sup o} SWA, the amount of angle tolerance for 0.2nm change in CD was in total 0.5{sup o}. For shadow LER, we found minimal difference between left and right LER when illuminated perpendicularly to the pattern, to at most 0.1nm LER at best focus. CTFs confirm the uniqueness and linearity of an LER transfer function as opposed to the traditional MTF, as shown in a previous study. In the future we wish to expand our work on shadow LER into the regime where the k{sub 1}-factor of the optic is stressed. In particular, 16nm lines and spaces on an NA = 0.32 optic with off-axis illumination.

36 MATERIALS SCIENCE↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Niobium coaxial cavities with internal quality factors exceeding 1.4 × 10 9 for circuit quantum electrodynamics

Group-V materials such as niobium and tantalum have become popular choices for extending the performance of circuit quantum electrodynamics (cQED) platforms, allowing for quantum processors and memories with reduced error rates and more modes. The complex surface chemistry of niobium, however, makes identifying the main modes of decoherence difficult at millikelvin temperatures and single-photon powers. We use niobium coaxial quarter-wave cavities to study the impact of etch chemistry, prolonged atmospheric exposure, and the significance of cavity conditions prior to and during cooldown—in particular, niobium hydride evolution—on single-photon coherence. We demonstrate cavities with quality factors Q int ≳ 1.4 × 10 9 in the single-photon regime, a 15-fold improvement over aluminum cavities of the same geometry. We rigorously quantify the sensitivity of our fabrication process to various loss mechanisms and demonstrate a two- to fourfold reduction in the two-level system loss tangent and a three- to fivefold improvement in the residual resistance over traditional buffered chemical polishing etching techniques. Finally, we demonstrate transmon integration and coherent cavity control while maintaining a cavity coherence of 11.3 ms. The accessibility of our method, which can be easily replicated in academic laboratory settings, together with the demonstration of its performance, mark an advancement in three-dimensional cQED.

Oriani, Andrew E. [Chicago U., EFI; Chicago U.] (O↗

Entangled coherent states versus entangled photon pairs for practical quantum-information processing

We compare effects of decoherence and detection inefficiency on entangled coherent states (ECSs) and entangled photon pairs (EPPs), both of which are known to be particularly useful for quantum-information processing (QIP). When decoherence effects caused by photon losses are heavy, the ECSs outperform the EPPs as quantum channels for teleportation both in fidelities and in success probabilities. On the other hand, when inefficient detectors are used, the teleportation scheme using the ECSs suffers undetected errors that result in the degradation of fidelity, while this is not the case for the teleportation scheme using the EPPs. Our study reveals the merits and demerits of the two types of entangled states in realizing practical QIP under realistic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study to investigate and evaluate means of optimizing the radar function for the space shuttle

Results are discussed of a study to define a radar and antenna system which best suits the space shuttle rendezvous requirements. Topics considered include antenna characteristics and antenna size tradeoffs, fundamental sources of measurement errors inherent in the target itself, backscattering crosssection models of the target and three basic candidate radar types. Antennas up to 1.5 meters in diameter are within specified installation constraints, however, a 1 meter diameter paraboloid and a folding, four slot backfeed on a two gimbal mount implemented for a spiral acquisition scan is recommended. The candidate radar types discussed are: (1) noncoherent pulse radar (2) coherent pulse radar and (3) pulse Doppler radar with linear FM ranging. The radar type recommended is a pulse Doppler with linear FM ranging. Block diagrams of each radar system are shown.

Source record↗

Limits on preserving quantum coherence using multipulse control

We explore the physical limits of pulsed dynamical decoupling methods for decoherence control as determined by finite timing resources. By focusing on a decohering qubit controlled by arbitrary sequences of {pi} pulses, we establish a nonperturbative quantitative upper bound to the achievable coherence for specified maximum pulsing rate and noise spectral bandwidth. We introduce numerically optimized control ''bandwidth-adapted'' sequences that saturate the performance bound and show how they outperform existing sequences in a realistic excitonic-qubit system where timing constraints are significant. As a by-product, our analysis reinforces the impossibility of fault-tolerance accuracy thresholds for generic open quantum systems under purely reversible error control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EdgeAI: Machine learning via direct attached accelerator for streaming data processing at high shot rate x-ray free-electron lasers

We present a case for low batch-size inference with the potential for adaptive training of a lean encoder model. We do so in the context of a paradigmatic example of machine learning as applied in data acquisition at high data velocity scientific user facilities such as the Linac Coherent Light Source-II x-ray Free-Electron Laser. We discuss how a low-latency inference model operating at the data acquisition edge can capitalize on the naturally stochastic nature of such sources. We simulate the method of attosecond angular streaking to produce representative results whereby simulated input data reproduce high-resolution ground truth probability distributions. By minimizing the mean-squared error between the decoded output of the latent representation and the ground truth distributions, we ensure that the encoding layers and resulting latent representation maintains full fidelity for any downstream task, be it classification or regression. We present throughput results for data-parallel inference of various batch sizes, some with throughput exceeding 100 k images per second. We also show in situ training below 10 s per epoch for the full encoder–decoder model as would be relevant for streaming and adaptive real-time data production at our nation’s scientific light sources.

97 MATHEMATICS AND COMPUTING↗

Electron scattering from argon: Data evaluation and consistency

The demand for coherent scattering data for modeling electron transport in matter has increased in recent years. While much effort has been devoted to the improvement of models describing electron transport and scattering, the updating of fundamental data sets on the basis of recent experimental results has often been neglected. The use of a well-validated set of electron cross sections ensures accurate calculations of transport parameters and ionization yields, with typical applications in material analysis, detector response studies, plasma diagnostics, physics of the atmosphere, and radiotherapy. Data consistency can be verified on the basis of various theoretical requirements, and systematic errors can be minimized by cross-checking results obtained from independent experiments. For example, the oscillator strength distribution of an atom can be obtained both from photoabsorption experiments and from zero-angle electron-atom collisions at high energy, on the basis of the Bethe theory. A considerable number of all electron-scattering experiments are concerned with light noble gases, in particular with argon. This gas is a dominant constituent of noble-gas discharge plasmas and plays an important role in rare-gas halide lasers and proportional scintillator counters. This work reviews electron-scattering cross sections and optical data for the argon atom, discusses the progress made in the field of electron scattering and photoabsorption, and focuses on the most appropriate criteria for verifying data consistency.

74 ATOMIC AND MOLECULAR PHYSICS↗

Global micro-tearing modes in the wide pedestal of an NSTX plasma

Global linear electromagnetic gyrokinetic simulations of micro-tearing modes (MTMs) growing in the wide pedestal of the ELM-free NSTX discharge #132 588 are reported. Two micro-tearing branches growing near the surfaces of safety factor q = 4 (pedestal top) and q=5–6 (pedestal) are simulated. The frequencies of these MTMs with low toroidal mode number (n ranging from 3 to 6) are in agreement with the ones of quasi-coherent fluctuations present on the magnetic spectrogram. No kinetic ballooning mode (KBM) is observed at experimental values of β; instead, the experimental plasma lies 20% below the critical global KBM threshold. This confirms local simulation results stating that experimental NSTX profiles lie in the KBM stability region. Carbon impurities, which are abundant in this plasma, were found to play a significant role. Neglecting them leads to a ∼50% error in the growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗