Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient of performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Aerocapture Performance Analysis of A Venus Exploration Mission

A performance analysis of a Discovery Class Venus Exploration Mission in which aerocapture is used to capture a spacecraft into a 300km polar orbit for a two year science mission has been conducted to quantify its performance. A preliminary performance assessment determined that a high heritage 70 sphere-cone rigid aeroshell with a 0.25 lift to drag ratio has adequate control authority to provide an entry flight path angle corridor large enough for the mission s aerocapture maneuver. A 114 kilograms per square meter ballistic coefficient reference vehicle was developed from the science requirements and the preliminary assessment s heating indicators and deceleration loads. Performance analyses were conducted for the reference vehicle and for sensitivity studies on vehicle ballistic coefficient and maximum bank rate. The performance analyses used a high fidelity flight simulation within a Monte Carlo executive to define the aerocapture heating environment and deceleration loads and to determine mission success statistics. The simulation utilized the Program to Optimize Simulated Trajectories (POST) that was modified to include Venus specific atmospheric and planet models, aerodynamic characteristics, and interplanetary trajectory models. In addition to Venus specific models, an autonomous guidance system, HYPAS, and a pseudo flight controller were incorporated in the simulation. The Monte Carlo analyses incorporated a reference set of approach trajectory delivery errors, aerodynamic uncertainties, and atmospheric density variations. The reference performance analysis determined the reference vehicle achieves 100% successful capture and has a 99.87% probability of attaining the science orbit with a 90 meters per second delta V budget for post aerocapture orbital adjustments. A ballistic coefficient trade study conducted with reference uncertainties determined that the 0.25 L/D vehicle can achieve 100% successful capture with a ballistic coefficient of 228 kilograms per square meter and that the increased ballistic coefficient increases post aerocapture V budget to 134 meters per second for a 99.87% probability of attaining the science orbit. A trade study on vehicle bank rate determined that the 0.25 L/D vehicle can achieve 100% successful capture when the maximum bank rate is decreased from 30 deg/s to 20 deg/s. The decreased bank rate increases post aerocapture delta V budget to 102 meters per second for a 99.87% probability of attaining the science orbit.

Starr, Brett R.↗

Evaluation of the Event Driven Phenology Model Coupled with the VegET Evapotranspiration Model Through Comparisons with Reference Datasets in a Spatially Explicit Manner

A new model coupling scheme with remote sensing data assimilation was developed for estimation of daily actual evapotranspiration (ET). The scheme represents a mix of the VegET, a physically based model to estimate ET from a water balance, and an event driven phenology model (EDPM), where the EDPM is an empirically derived crop specific model capable of producing seasonal trajectories of canopy attributes. In this experiment, the scheme was deployed in a spatially explicit manner within the croplands of the Northern Great Plains. The evaluation was carried out using 2007-2009 land surface forcing data from the North American Land Data Assimilation System (NLDAS) and crop maps derived from remotely sensed data of NASA's Moderate Resolution Imaging Spectroradiometer (MODIS). We compared the canopy parameters produced by the phenology model with normalized difference vegetation index (NDVI) data derived from the MODIS nadir bi-directional reflectance distribution function (BRDF) adjusted reflectance (NBAR) product. The expectations of the EDPM performance in prognostic mode were met, producing determination coefficient (r2) of 0.8 +/-.0.15. Model estimates of NDVI yielded root mean square error (RMSE) of 0.1 +/-.0.035 for the entire study area. Retrospective correction of canopy dynamics with MODIS NDVI brought the errors down to just below 10% of observed data range. The ET estimates produced by the coupled scheme were compared with ones from the MODIS land product suite. The expected r2=0.7 +/-.15 and RMSE = 11.2 +/-.4 mm per 8 days were met and even exceeded by the coupling scheme0 functioning in both prognostic and retrospective modes. Minor setbacks of the EDPM and VegET performance (r2 about 0.5 and additional 30 % of RMSR) were found on the peripheries of the study area and attributed to the insufficient EDPM training and to spatially varying accuracy of crop maps. Overall the experiment provided sufficient evidence of soundness and robustness of the EDPM and VegET coupling scheme, assuring its potential for spatially explicit applications.

Kovalskyy, V.↗

Computational Analysis of the X-57 Maxwell Airplane at Unpowered Conditions (Preliminary Fuselage)

The X-57 Maxwell is an all-electric airplane that implements a distributed electric propulsion system to demonstrate that high-efficiency electric propulsion can be integrated with aerodynamics to increase the performance of an airplane. To this end, distributed electric fans were installed on the wing to provide increased flow over the wing at the low takeoff and landing speeds of the X-57. The low-speed lift augmentation allows for a reduction in wing area for cruise optimization. The X-57 wing area was reduced to 42 percent of the wing area of the baseline aircraft, a Tecnam P2006T. With this reduced wing area and the electric propulsion system, it is estimated that the X-57 will cruise on less than one-third the total energy compared to the baseline aircraft. To meet the cruise performance goal at a Mach number of 0.233 at an altitude of 8000 feet, the X-57 has a cruise lift coefficient of 0.7516 and needs to have a cruise drag coefficient of 0.05423 or less. The USM3D computational solver was used to investigate the X-57 performance, without the distributed electric propulsion high-lift system operating. The unpowered X-57 performance is of interest to quantify if the X-57 can meet the cruise drag performance goal, and to document the lift performance of the very small wing at takeoff and landing conditions. The primary configurations investigated in this paper include the cruise configuration with no flap deflection, a takeoff configuration with a 10◦ flap deflection, and a landing configuration with a 30◦ flap deflection. The conditions for the cruise configuration were a flight unit Reynolds number of 1.32E+06 per foot, an altitude of 8000 feet, a Mach number of 0.233, and angles of attack from −2° to 24° . At the cruise lift coefficient of 0.7516, the computed drag coefficient is 0.05275. This computed drag is less than the drag coefficient of 0.05423 that is required to meet the X-57 airplane performance goal. However, the computational airplane is a completely smooth geometry and does not account for protuberance drag, nor the drag from steps and gaps in the actual X-57 airplane. Therefore, based upon the CFD drag calculation there is a 10-percent margin to account for some of the differences between the as-built metal fuselage and empennage construction, and the smooth computational geometry. The computed cruise drag also does not account for an induced drag reduction due to the wing-tip propellers and a drag reduction due to laminar flow achieved on the wing. The computed lift to drag ratio is 14.14 at the cruise lift coefficient of 0.7516, and the maximum computed lift to drag ratio is 15.8. The maximum lift coefficient for the cruise configuration was 2.13 at an angle of attack of 15°. The conditions for the takeoff configuration with a 10° flap deflection were a flight unit Reynolds number of 0.986E+06 per foot, an altitude of 2500 feet, a Mach number of 0.149, and angles of attack from −2° to 22°. The maximum lift coefficient for the takeoff configuration was 2.21 at an angle of attack of 16°. The conditions for the landing configuration with a 30° flap deflection were a flight unit Reynolds number of 0.922E+06 per foot, an altitude of 2500 feet, a Mach number of 0.139, and angles of attack from −2° to 24°. The maximum lift coefficient for the landing configuration was 2.58 and occurred at two angles of attack, 10° and 14°. Based on the unpowered maximum lift coefficient of 2.58 for the 30° flap deflection, along with computations of the distributed electric propulsion lift augmentation (not shown in this paper), the X-57 Maxwell is estimated to meet its powered landing goal of a maximum lift coefficient of 4.0.

X-57 Maxwell Airplane↗

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

Cavitation in liquid cryogens. 4: Combined correlations for venturi, hydrofoil, ogives, and pumps

The results of a series of experimental and analytical cavitation studies are presented. Cross-correlation is performed of the developed cavity data for a venturi, a hydrofoil and three scaled ogives. The new correlating parameter, MTWO, improves data correlation for these stationary bodies and for pumping equipment. Existing techniques for predicting the cavitating performance of pumping machinery were extended to include variations in flow coefficient, cavitation parameter, and equipment geometry. The new predictive formulations hold promise as a design tool and universal method for correlating pumping machinery performance. Application of these predictive formulas requires prescribed cavitation test data or an independent method of estimating the cavitation parameter for each pump. The latter would permit prediction of performance without testing; potential methods for evaluating the cavitation parameter prior to testing are suggested.

Hord, J.↗

Effects of Encapsulant Properties on the Thermo-Mechanical Reliability of Double-Side Cooled Power Modules for Traction Inverters

Double-side cooled power modules are being developed for next-generation traction inverters due to their better heat extraction, lower profile, and lower parasitic inductances. However, due to their rigid structure, they cause reliability concerns arising from high thermo-mechanical stresses at the interconnection joints in the module. In this work, a materials-based approach using rigid encapsulants is presented for reducing thermo-mechanical fatigue. Finite-element thermo- mechanical simulations were performed to examine the effects of the elastic modulus and coefficient of thermal expansion of epoxy- based encapsulants on the bond deformation inside a double-side cooled power module. It was found that a rigid encapsulant with a high modulus of 6.0 GPa or above and a coefficient of thermal expansion around 20 ppm/oC would improve the thermo- mechanical reliability of double-side cooled power modules by decreasing the permanent bond deformation inside the modules by 50-60%.

ADVANCED PROPULSION SYSTEMS↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

Measurement of heat-transfer coefficients in shock wave-turbulent boundary layer interaction regions with a multi-layered thin film heat transfer gauge

A thin film heat transfer gauge is applied to the measurement of heat transfer coefficients in the interaction regions of incident shock waves and fully developed turbulent boundary layers. It was developed to measure heat flux with high spatial resolution and fast response for wind tunnels with long flow duration. To measure the heat transfer coefficients in the interaction region in detail, experiments were performed under the conditions of Mach number = 4, total pressure = 1.2 MPa, 0.59 to approximately 0.65. Reynolds number = 1.3 to approximately 1.5 x 10 to the 7th power and incident shock angles from 17.8 to 22.8 degrees. The results show that the heat transfer coefficient changes complicatedly in the interaction region. At the beginning the interaction region, the heat transfer coefficient decreases at first, reaches its minimum value at the point where the pressure begins to increase, and then increases sharply. When the boundary layer begins to separate, even a small separation bubble causes significant changes in the heat transfer coefficient, while the pressure does not show any changes which suggests that the boundary layer begins to separate.

Hayashi, M.↗

Butterfly valve performance factors using the multiphysics object oriented simulation environment

Butterfly valves are typically used in nuclear reactors to control incompressible fluid flow with high inlet velocities. Performance factors for butterfly valves include the pressure drop across the valve and the loss coefficient from which hydrodynamic torque and flow coefficients can be computed. This work explores a computational fluid dynamics approach for butterfly valve performance factors using the open-source Multiphysics Object Oriented Simulation Environment (MOOSE) framework. While MOOSE is often used in the nuclear energy modeling and simulation community for simulations ranging from fuel characterization to heat pipe simulation, this work employs the MOOSE open-source Navier–Stokes solver capability for simulating butterfly valve performance factors and compares those to experimentally measured results from the Advanced Test Reactor at Idaho National Laboratory at Reynolds numbers in the order of 10 6 for the partially opened configuration. The MOOSE framework results are compared against experimentally measured butterfly valve performance factors across five valve opening angles using meshes with order 10 4 – 10 5 elements. This validation serves to enable MOOSE-based multiphysics simulations incorporating the open-source Navier–Stokes module.

97 - MATHEMATICS AND COMPUTING↗

Theory of a generalized Helmholtz resonator.

Based on the jet-flow model which is manifested in the nonlinearity of the orifice flow upon the passage of a high intensity wave, the theory of a generalized Helmholtz resonator has been developed. The results for some special devices, such as the conventional Helmholtz resonator and the quarter-wave tube, can be obtained through this general approach. The performance of the acoustic damper is characterized by a quantity known as the real part of the admittance coefficient. It is known that the conventional Helmholtz resonator has the lowest peak performance but the response is quite flat over a certain frequency range. On the other hand, a quarter-wave tube offers the largest peak in energy absorption with rather poor off-resonance behavior. Once the orifice length goes beyond the quarter-wave tube configuration, the performance of the so-called long damping device is even less attractive away from resonance.

Tang, P. K.↗

Machine learning-based optimization of air-cooled heat sinks

Machine learning-based models using Artificial Neural Network (ANN) and greedy search algorithm are used to optimize air-cooled parallel plate-finned heat sinks (PPFHSs) subjected to laminar flow over an extensive range of design parameters. Here, the thermal and hydraulic performances of PPFHSs are represented by heat transfer coefficient (h) and pressure drop (ΔP), respectively. Optimization objectives for PPFHS designs can vary from industry to industry depending on their design priorities. The present study proposes a novel and generalized optimization method that defines practical optimization objectives and provides an accurate optimization process to design effective PPFHSs for a wide range of industrial applications with different design requirements. Three optimization objectives are presented in this study: (i) the largest h PΔ, (ii) the largest h within a specified maximum allowed flow rate, and (iii) the lowest weight that maximizes h for operation within the maximum allowed flow rate. While the shortcoming of the first objective is demonstrated, the other two objectives are found to be suitable for designing effective heat sinks (HSs) across different applications. Results suggest a promising trend from the third objective to develop HSs with ~ 37-68% lower weight, 80-85% reduced ΔP, and negligible penalty in h compared with optimized HSs obtained from the second objective. However, since the third objective leads to HSs with thinner fins, structural analysis should be performed to ensure reliable operation of the HSs.

42 ENGINEERING↗

Development and Evaluation of Ensemble Learning-based Environmental Methane Detection and Intensity Prediction Models

The environmental impacts of global warming driven by methane (CH 4 ) emissions have catalyzed significant research initiatives in developing novel technologies that enable proactive and rapid detection of CH 4 . Several data-driven machine learning (ML) models were tested to determine how well they identified fugitive CH 4 and its related intensity in the affected areas. Various meteorological characteristics, including wind speed, temperature, pressure, relative humidity, water vapor, and heat flux, were included in the simulation. We used the ensemble learning method to determine the best-performing weighted ensemble ML models built upon several weaker lower-layer ML models to (i) detect the presence of CH 4 as a classification problem and (ii) predict the intensity of CH 4 as a regression problem. The classification model performance for CH 4 detection was evaluated using accuracy, F1 score, Matthew’s Correlation Coefficient (MCC), and the area under the receiver operating characteristic curve (AUC ROC), with the top-performing model being 97.2%, 0.972, 0.945 and 0.995, respectively. The R 2 score was used to evaluate the regression model performance for CH 4 intensity prediction, with the R 2 score of the best-performing model being 0.858. The ML models developed in this study for fugitive CH 4 detection and intensity prediction can be used with fixed environmental sensors deployed on the ground or with sensors mounted on unmanned aerial vehicles (UAVs) for mobile detection.

Majumder, Reek↗

Additively manufactured polymer composites for heat exchanger applications: evaluation of critical thermophysical properties

Polymeric heat exchangers (PHXs) have been used in applications involving weight restrictions, chemical compatibility, and fouling issues. Additive manufacturing (AM) or 3D printing provide new solutions to previously inaccessible combinations of properties and geometries. There are some advancements in the PHXs by AM; however, the process and the properties of materials still need further investigation to improve the overall performance. In this study, additively manufactured polyethylene terephthalate glycol (PETG) composites reinforced with graphite and pitch-based carbon fibers were evaluated for their potential application as PHXs. The thermal conductivity, volumetric heat capacity, coefficient of thermal expansion, creep behavior, and long-term performance were studied in detail. Our results reveal that the composites have an anisotropic thermal conductivity. The thermal conductivity along the printing direction is higher than the layer building direction due to the shear-induced alignment of the fillers. The printed composites achieve good thermal stability with 80% lower CTE at room temperature than neat PETG. Creep tests suggest the creep and creep recovery were highly temperature-dependent, and the deformation can be recovered when the temperature is below glass transition. These results suggest additive manufactured composites be potentially used for heat exchanger applications at low temperatures.

36 MATERIALS SCIENCE↗

Wall-modeled LES of Turbulent Flow Over a Two-dimensional Gaussian Bump

We perform wall-modeled large eddy simulations (WMLES) of turbulent flow over a nominally two-dimensional Gaussian-shaped bump geometry to assess its performance in the accelerating and separation regions of the flow. The flow conditions are based on high-fidelity numerical simulation of Uzun & Malik (AIAA Journal 2022). The oncoming flow Mach number is 0.2, with the bump length-based Reynolds number (ReL) of 2 million. In our previous study, while WMLES with the constant coefficient Vreman subgrid scale model and equilibrium wall model performed satisfactorily at lower ReL = 1 million, it failed to predict flow separation at the higher Re, contrary to the experimental observations. We investigate the sensitivity of WMLES to different subgrid scale models, wall models, and grid resolution and topology on flow separation by comparing with available data.

Computational Fluid Dynamics↗

Two-dimensional analytical and experimental performance comparison for a compressor stator section with D-factor of 0.47

Analytically computed flow parameters were compared to measured values for the midspan double-circular-arc section of a stator in subsonic flow. Analytical procedures included calculations for inviscid flow, blade surface boundary layers, and loss coefficients. Comparisons were made at three incidence angles. Methods for prescribing the exit fluid angle in inviscid flow calculations were investigated. Measured loss coefficients were compared to calculated values. Two methods for predicting performance involving iterative use of ideal flow and boundary layer calculations were investigated.

Sanger, N. L.↗

Analytical homogenization techniques applied to the Fickian diffusion: Effective diffusivity coefficient

For multiple applications in nuclear energy, the ability to accurately represent material behavior with a simplified model is important to facilitate practical engineering-scale simulations. In this work, we focus on the homogenized thermal response of a medium containing spherical inclusions, similar to a fuel form (compact or pebble) containing TRISO particles. An extensive survey on effective thermal conductivity modeling was performed in our previous study, considering a random distribution of mono-sized spherical inclusions in a continuous matrix. Using the analogy between heat conduction and the simplified Fickian diffusion (or fission product species conservation), we can use the same analytical homogenization methods to obtain ETC as for the effective diffusivity coefficient (EDC). We performed several numerical experiments at varying conditions to assess the validity of our hypothesis for EDC calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of the Performance of an Axial-Flow-Pump Stage Designed by the Blade-Element Theory: Blade-Element Data

An axial-flow-pump stage was designed by utilizing blade-element methods in conjunction with axial-flow-compressor blade-element theory. This report presents the blade-element data of the pump stage in both the noncavitating and cavitating conditions. The noncavitating blade- element performance is compared with design rules. The results indicated that some modification of the compressor design equations for computing minimum-loss incidence and deviation angles may be necessary for application to an axial-flow-pump design. Minimum values of observed rotor loss were slightly lower than anticipated from compressor results. At the design flow coefficient the rotor-blade elements were not operating at the reference incidence angles, and the experimental efficiency was lower than the design value. The observed head rise was very close to the design. An attempt was made to estimate the potential of this rotor by using the minimum measured values of loss coefficient and observed energy input at the design flow. Performance of the pump at a suction specific speed of approximately 13,000 (cavitation number k approximately equals 0.12) showed only a slight dropoff in performance in the cavitation inception region from the noncavitating results. The observed performance at a suction specific speed of approximately 16,000 (k approximately equals 0.09) is also presented for comparison.

Crouse, James E.↗