Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Dual capillary tube / heat exchanger in combination with cycle priming for reducing charge migration

A refrigerator appliance including a multi-capacity compressor and a refrigerant circuit with two conduits and pressure reducing devices arranged in parallel between an evaporator and a condenser. Refrigerant can flow through one, both or none of the conduits and pressure reducing devices. The appliance also has a heat exchanger in contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system. The appliance also includes a controller for priming the compressor above a nominal capacity for a predetermined or calculated duration at the beginning of an ON-cycle.

42 ENGINEERING↗

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments on the Capillary Condensation/Evaporation Hysteresis of Pure Fluids and Binary Mixtures in Cylindrical Nanopores

Here, a new experimental method, i.e., isochoric cooling/heating cycle measurement using differential scanning calorimeter (DSC), is applied to investigate the hysteretic phenomenon of pure components and mixtures confined in two different types of cylindrical nanopores (SBA-15 and KIT-6). The capillary condensation/evaporation hysteresis end point (T he ) for a specific system is determined by performing a series of measurements with different densities by increasing initial temperature and pressure. We confirm that for a pure component, T he is lower when confined in smaller nanopores, whereas T he for CH 4 /CO 2 and CH 4 /C 2 H 6 mixtures at the specific composition investigated are higher than that of pure CO 2 and C 2 H 6 , respectively, when confined in the same nanopores. To the best of our knowledge, this is the first time that T he of fluid mixture is experimentally studied, which further demonstrates that binary mixtures behave similarly to pure fluids when confined in nanoporous media. At low temperatures where hysteresis is observed, the shape as well as the duration of the exothermic peak (due to capillary condensation) and endothermic peak (due to capillary evaporation) indicate that capillary condensation, rather than capillary evaporation, takes place at/near a thermodynamic equilibrium. Within the accuracy of the measurements, we find that the total heat of capillary condensation is identical to that of capillary evaporation for all systems examined, regardless of the presence of hysteresis. By comparing the heat per unit volume among different systems, we also find that the heat per unit volume of the phase transition of confined pure fluid is lower than that of bulk, which further demonstrates that the molar density of confined pure liquid is less than that of bulk pure liquid at saturation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supercritical CO 2 Water Displacements and CO 2 Capillary Trapping: Micromodel Experiment and Numerical Simulation

We report that the CO 2 capillary trapping is an important scientific issue in geological carbon sequestration, but few researches focus on the trapping mechanism at pore scale under supercritical CO 2 condition. In this study, based on the high-pressure fluids-microscopy-micromodel experimental system, we performed drainage experiment, i.e. supercritical CO 2 displacing water, and imbibition experiment, i.e. water displacing CO 2 , under the conditions of 45°C and 8.5 MPa. The DSLR camera was used to capture pictures of CO 2 -water two-phase immiscible flow and the microscopy was used to capture the capillary trapping behavior for the supercritical CO 2 at the pore scale. The computational fluid dynamic method was adopted to simulate the two-phase fluid flow processes. The numerical results are generally in agree ment with the experimental observations, and further provide three-dimensional geometries on the interface during the drainage-imbibition processes and the trapped supercritical CO 2 droplet/cluster. Lastly, the capillary trapping curve, i.e. the relationship between the initial CO 2 saturation and the residual saturation, was obtained from the numerical results, and we made an assessment of the three capillary trapping models, i.e. Land's, Jurauld's and Spiteri's trapping models. A comparison of the models performance indicates that Jurauld's model behaves slightly better than Land's model, whereas Spiteri's model behaves poorly. However, given that Land's model only contains one parameter of clear physical meaning, it is recommended for practical use.

58 GEOSCIENCES↗

Recovery of Iron/Iron Oxide Nanoparticles from Solution: Comparison of Methods and their Effects

Most methods currently being used to recover Fe0-core/oxide-shell nanoparticles from solutions (including the solvents they are synthesized or stored in) are potentially problematic because they may alter the particle composition (e.g., depositing salts formed from solutes) or leave the particles prone to transformations during subsequent storage and handling (e.g., due to residual moisture). In this study, several methods for recovery of nanoparticles from aqueous solution were studied to determine how they affect the structure and reactivity of the recovered materials. Simple washing of the nanoparticles during vacuum filtration (i.e., “flash drying”) can leave up to ~17 weight percent residual moisture. Modeling calculations suggest this moisture is mostly capillary or matric water held between particles and particle aggregates, which can be removed by drying for short periods at relative vapor pressures below 0.9. Flash drying followed by vacuum drying, all under N2, leaves no detectable residue from precipitation of solutes (detectable by X-ray photoelectron spectroscopy, XPS), no significant changes in overall particle composition or structure (determined by transmission electron microscopy, TEM), and negligible residual moisture (by thermogravimetric analysis, TGA). While this improved flash-drying protocol may be the preferred method for recovering nanoparticles for many purposes, we found that Fe0-core/oxide-shell nanoparticles still exhibit gradual aging during storage when characterized electrochemically with voltammetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of Transient Heat Pipe Operation

The major goal of this project is to develop mathematical models of heat pipes which can be used to predict transient behavior under normal and adverse conditions. The models and solution techniques are to be formulated so that they can be incorporated into existing NASA structural design codes. The major parameters of interest are heat flux distribution, temperature distribution, working fluid pressure distribution, fluid and containment thermal and mechanical properties and geometry. Normal transient operation is taken to be operating conditions where the capillary structure remains fully wetted. Adverse transient operation occurs when drying, re-wetting, choking, non-continuum flow, thawing, freezing, etc., occur in the internal heat pipe working fluid.

Colwell, G. T.↗

A study of metal-ceramic wettability in SiC-Al using dynamic melt infiltration of SiC

Pressure-assisted infiltration with a 2014 Al alloy of plain and Cu-coated single crystal platelets of alpha silicon carbide was used to study particulate wettability under dynamic conditions relevant to pressure casting of metal-matrix composites. The total penetration length of infiltrant metal in porous compacts was measured at the conclusion of solidification as a function of pressure, infiltration time, and SiC size for both plain and Cu-coated SiC. The experimental data were analyzed to obtain a threshold pressure for the effect of melt intrusion through SiC compacts. The threshold pressure was taken either directly as a measure of wettability or converted to an effective wetting angle using the Young-Laplace capillary equation. Cu coating resulted in partial but beneficial improvements in wettability as a result of its dissolution in the melt, compared to uncoated SiC.

Asthana, R.↗

The behavior of a liquid drop levitated and drastically flattened by an intense sound field

The deformation and break-up are studied of a liquid drop in levitation through the radiation pressure. Using high-speed photography ripples are observed on the central membrane of the drop, atomization of the membrane by emission of satellite drops from its unstable ripples, and shattering of the drop after upward buckling like an umbrella, or after horizontal expansion like a sheet. These effects are captured on video. The ripples are theorized to be capillary waves generated by the Faraday instability excited by the sound vibration. Atomization occurs whenever the membrane becomes so thin that the vibration is sufficiently intense. The vibration leads to a destabilizing Bernoulli correction in the static pressure. Buckling occurs when an existent equilibrium is unstable to a radial (i.e., tangential) motion of the membrane because of the Bernoulli effect. Besides, the radiation stress at the rim of the drop is a suction stress which can make equilibrium impossible, leading to the horizontal expansion and the subsequent break-up.

Lee, C. P.↗

Computing Thermodynamic Properties of Fluids Augmented by Nanoconfinement: Application to Pressurized Methane

Nanoconfined fluids exhibit remarkably different thermodynamic behavior compared to the bulk phase. These confinement effects render predictions of thermodynamic quantities of nanoconfined fluids challenging. In particular, confinement creates a spatially varying density profile near the wall that is primarily responsible for adsorption and capillary condensation behavior. Significant fluctuations in thermodynamic quantities, inherent in such nanoscale systems, coupled to strong fluid–wall interactions give rise to this near-wall density profile. Empirical models have been proposed to explain and model these effects, yet no first-principles based formulation has been developed. We present a statistical mechanics framework that embeds such a coupling to describe the effect of the fluid–wall interaction in amplifying the near-wall density behavior for compressible gases at elevated pressures such as pressurized methane in confinement. We show that the proposed theory predicts accurately the adsorbed layer thickness as obtained with small-angle neutron scattering measurements. Furthermore, the predictions of density under confinement from the proposed theory are shown to be in excellent agreement with available experimental and atomistic simulations data for a range of temperatures for nanoconfined methane. While the framework is presented for evaluating the near-wall density, owing to its rigorous foundation in statistical mechanics, the proposed theory can also be generalized for predicting phase-transition and nonequilibrium transport of nanoconfined fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Thermal Control and Enhancement of Heat Transport Capacity of Two-Phase Loops With Electrohydrodynamic Conduction Pumping

There are three kinds of electrohydrodynamics (EHD) pumping based on Coulomb force: induction pumping, ion-drag pumping, and pure conduction pumping. EHD induction pumping relies on the generation of induced charges. This charge induction in the presence of an electric field takes place due to a non-uniformity in the electrical conductivity of the fluid which can be caused by a non-uniform temperature distribution and/or an inhomogeneity of the fluid (e.g. a two-phase fluid). Therefore, induction pumping cannot be utilized in an isothermal homogeneous liquid. In order to generate Coulomb force, a space charge must be generated. There are two main mechanisms for generating a space charge in an isothermal liquid. The first one is associated with the ion injection at a metal/liquid interface and the related pumping is referred to as ion-drag pumping. Ion-drag pumping is not desirable because it can deteriorate the electrical properties of the working fluid. The second space charge generation mechanism is associated with the heterocharge layers of finite thickness in the vicinity of the electrodes. Heterocharge layers result from dissociation of the neutral electrolytic species and recombination of the generated ions. This type of pumping is referred to as pure conduction pumping. This project investigates the EHD pumping through pure conduction phenomenon. Very limited work has been conducted in this field and the majority of the published papers in this area have mistakenly assumed that the electrostriction force was responsible for the net flow generated in an isothermal liquid. The main motivation behind this study is to investigate an EHD conduction pump for a two-phase loop to be operated in the microgravity environment. The pump is installed in the liquid return passage (isothermal liquid) from the condenser section to the evaporator section. Unique high voltage and ground electrodes have been designed that generate sufficient pressure heads with very low electric power requirements making the EHD conduction pumping attractive to applications such as two-phase systems (e.g. capillary pumped loops and heat pipes). Currently, the EHD conduction pump performance is being tested on a two-phase loop under various operating conditions in the laboratory environment. The simple non-mechanical and lightweight design of the EHD pump combined with the rapid control of performance by varying the applied electric field, low power consumption, and reliability offer significant advantages over other pumping mechanisms; particularly in reduced gravity applications.

Seyed-Yagoobi, J.↗

Low-Dead-Volume Inlet for Vacuum Chamber

Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

Naylor, Guy↗

Low-Dead-Volume Inlet for Vacuum Chamber

Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead-volume. As a result, a high-vacuum gas inlet was developed with low dead-volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

Naylor, Guy↗

Critical heat flux on micro-structured zircaloy surfaces for flow boiling of water at low pressures

The influence of surface structure on critical heat flux for flow boiling of water was investigated for Zircaloy tubes in a vertical annular test section. The objectives were to find suitable surface modification processes for Zircaloy tubes and to test their critical heat flux performance in comparison to the smooth tube. Surface structures with micro-channels, porous layer, oxidized layer, and elevations in micro- and nano-scale were produced on a section of a Zircaloy cladding tube. These modified tubes were tested in an internally heated vertical annulus with a heated length of 326 mm and an inner and outer diameter of 9.5 and 18 mm. The experiments were performed with mass fluxes of 250 and 400 kg/(m{sup 2}s), outlet pressures between 120 and 300 kPa, and constant inlet subcooling enthalpy of 167 kJ/kg. Only a small influence of modified surface structures on critical heat flux was observed for the pressure of 120 kPa in the present test section geometry. However, with increasing pressure the critical heat flux could increase up to 29% using the surface structured tubes with micro-channels, porous and oxidized layers. Capillary effects and increased nucleation site density are assumed to improve the critical heat flux performance. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Gravity of Giraffe Physiology

By virtue of its tallness and terrestrial environment, the giraffe is a uniquely sensitive African animal to investigate tissue adaptations to gravitational stress. One decade ago, we studied transcapillary fluid balance and local tissue adaptations to high cardiovascular and musculoskeletal loads in adult and fetal giraffes. Previous studies by Goetz, Pattersson, Van Citters, Warren and their colleagues revealed that arterial pressure near the giraffe heart is about twice that in humans, to provide more normal blood pressure and perfusion to the brain. Another important question is how giraffes avoid pooling of blood and tissue fluid (edema) in dependent tissue of the extremities. As monitored by radiotelemetry, the blood and tissue fluid pressures that govern transcapillary exchange vary greatly with exercise. These pressures, combined with a tight skin layer, move fluid upward against gravity. Other mechanisms that prevent edema include precapillary vasoconstriction and low permeability of capillaries to plasma proteins. Other anatomical adaptations in dependent tissues of giraffes represent developmental adjustments to high and variable gravitational forces. These include vascular wall hypertrophy, thickened capillary basement membrane and other connective tissue adaptations. Our results in giraffe suggest avenues of future gravitational research in other animals including humans.

Hargens, Alan R.↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Relative permeabilities for two-phase flow through wellbore cement fractures

Multiple fluids are likely to exist in fractures and flow paths associated with leaky wellbores, including liquids (e.g., crude oil) and gases (e.g., gas exsolved from liquid). These fluids occupy and move through different portions of the pore spaces within the fractures depending on many factors, including fluid properties, fracture size, and the amount of the different fluids. Upward leakage of any phase, through the fracture, can contaminate water-bearing formations, create hazardous surface conditions, and compromise the functionality of the wellbore. Early signs of wellbore leaks may be expressed by anomalous pressure behavior at surface monitoring points on cavern storage wells. These pressure anomalies are difficult to interpret, necessitating knowledge of the factors that affect the multiphase flow in fractures and porous media. These parameters are critical to modeling multiphase flow in fractures. This insight can guide further diagnosis and maximize leak remediation. Here, our study focuses on the relationship of the liquid–gas relative permeabilities for representative variable-aperture wellbore cement fracture. To obtain the relative permeability of each phase, two-phase flow tests were conducted where both fluids were flowing simultaneously through a fractured wellbore cement specimen under a range of factors, namely (1) aperture size, (2) capillary numbers, and (3) viscosity ratio. The flow experiments were conducted under a range of confining stresses and flow velocities, using nitrogen gas and silicone oils (of different viscosities) in a specially designed pressure vessel. The sum of gas and oil relative permeabilities were found to be less than one under all conditions, which indicates that the presence of one phase affects the permeability of the other phase, and vice versa. Since the gas phase flow conditions include a significant inertial flow component in addition to viscous flow, the inertial flow coefficients at different saturation states are presented. The factors affecting the relationship between the relative permeabilities are discussed in detail. A new mathematical model for estimating the relative permeability of wellbore cement fracture is presented and experimentally validated.

58 GEOSCIENCES↗