Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Development of high concentration photovoltaics (HCPV) power plants in the US Southwest: Economic assessment and sensitivity analysis

High concentration photovoltaic (HCPV) technologies offer several advantages over typical PV systems. In this study, a detailed economic assessment and sensitivity analysis of deploying HCPV plants in the US southwest is performed. To do this, a 20 MWdc HCPV power plant is designed using the System Advisor Model (SAM) and is evaluated from both technical and financial aspects. The sensitivity analysis shows that reducing the installed cost per capacity of the HCPV system can significantly improve the economics and reduce the levelized cost of electricity (LCOE) and levelized power purchase agreement (LPPA). Also, providing proper incentives including both investment tax credits (ITC) and production tax credit (PTC), loan debt ratio, and interest rate are among the most influential parameters. The analysis shows that with the 30% ITC, the LCOE, and LPPA of the designed HCPV projects are between $65.4/MWh and $69.3/MWh and between $71.0/MWh and $75.2/MWh, respectively. The estimated LCOE and LPPA values are almost 50% higher than the utility-scale PV projects. If proper funding is provided to continue the support of the HCPV system, they would become more economical and competitive with PV plants. Federal and state government policies must also be established to advocate HCPV systems.

14 SOLAR ENERGY↗

Inequalities in global residential cooling energy use to 2050

Intersecting socio-demographic transformations and warming climates portend increasing worldwide heat exposures and health sequelae. Cooling adaptation via air conditioning (AC) is effective, but energy-intensive and constrained by household-level differences in income and adaptive capacity. Using statistical models trained on a large multi-country household survey dataset (n = 673,215), we project AC adoption and energy use to mid-century at fine spatial resolution worldwide. Globally, the share of households with residential AC could grow from 27% to 41% (range of scenarios assessed: 33-48%), implying up to a doubling of residential cooling electricity consumption, from 1220 to 1940 (scenarios range: 1590-2377) terawatt-hours yr. –1 , emitting between 590 and 1,365 million tons of carbon dioxide equivalent (MtCO 2 e). AC access and utilization will remain highly unequal within and across countries and income groups, with significant regressive impacts. Up to 4 billion people may lack air-conditioning in 2050. Our global gridded projections facilitate incorporation of AC’s vulnerability, health, and decarbonization effects into integrated assessments of climate change.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing the Contribution of ECa and NDVI in the Delineation of Management Zones in a Vineyard

Precision fertilization implies the need to identify the variability of soil fertility, which is costly and time-consuming. Remotely measured data can be a solution. Using this strategy, a study was conducted, in a vineyard, to delineate different management zones using two indicators: apparent soil electrical conductivity (ECa) and normalized difference vegetation index (NDVI). To understand the contribution of each indicator, three scenarios were used for zone definition: (1) using only NDVI, (2) only ECa, or (3) using a combination of the two. Then the differences in soil fertility between these zones were assessed using simple statistical methods. The results indicate that the most beneficial strategy is the combined use of the two indicators, as it allowed the definition of three distinct zones regarding important soil variables and crop nutrients, such as soil total nitrogen, Mg2+ cation, exchange acidity, and effective cation exchange capacity, and some relevant cation ratios. This strategy also allowed the identification of an ionic unbalance in the soil chemistry, due to an excess of Mg2+, that was harming crop health, as reported by NDVI. This also impacted ECa and NDVI relationship, which was negative in this study. Overall, the results demonstrate the advantages of using remotely sensed data, mainly more than one type of sensing data, and suggest a high potential for differential crop fertilization and soil management in the study area.

Esteves, Catarina (ORCID:0000000327205906)↗

Seawater Acidification and Bubble Plume Dispersion from Accidental Subsea CO 2 Pipeline Rupture: A Multiphase CFD Study

If a CO 2 reservoir or transmission pipeline were to leak, both the surrounding ecology and maritime traffic safety could be put at risk. To better understand and prepare for this risk, multiphase Computational Fluid Dynamics (CFD) models were built in ANSYS Fluent to capture the behavior of a leak once it enters the water. A 3D Eulerian–Eulerian model was used for validation, while a simplified 2D model was applied to simulate conditions at a 50-m depth. The models integrate bubble dynamics, gas holdup, CO 2 dissolution, dissolved species transport, and seawater acidification into a unified CFD framework. Mass transfer was calculated using the Hughmark correlation, and local seawater temperature and salinity were factored in to determine dissociation behavior and the relevant Henry’s Law constant. To confirm the 3D model’s accuracy, results were checked against two experimental datasets: the QICS field study and the Hauser Tank experiments. The team also modeled a hypothetical release scenario at the High Island 10L site and compared the results with earlier published work. The results show that at a depth of 50 m, the surrounding water column can completely absorb a CO 2 release at a rate of 35 kg/s, since the gas dissolves into the seawater as it rises toward the surface. Beyond confirming this mitigation capacity, the simulations shed light on how a leak would actually unfold in the environment, including the shape and movement of the rising bubble plume, how much CO 2 dissolves along the way, and the resulting shifts in seawater pH and pCO 2 . Together, this provides a practical framework for assessing how CO 2 leaks could affect marine environments in the Gulf of Mexico.

54 ENVIRONMENTAL SCIENCES↗

Zero-Emission Transit Bus Needs Assessment

The transition to zero-emissions vehicles (ZEVs) in public transit has gained traction due to significant federal investments from the Bipartisan Infrastructure Law (BIL) and the Inflation Reduction Act (IRA). This needs assessment, commissioned by the Joint Office of Energy and Transportation and conducted by researchers at the Idaho National Laboratory, explores the current state of electrification in transit agencies, identifying barriers to implementation, potential funding sources, and operational considerations necessary for a successful transition. The assessment involved qualitative interviews with representatives from 19 transit service providers across diverse geographic regions. Key findings highlight the challenges related to bus facilities and operations, which require careful planning for charging infrastructure and maintenance capabilities to accommodate battery electric buses (BEBs) and hydrogen fuel cell buses (HFCBs). Agencies reported operational hurdles due to the shorter range of BEBs compared to diesel buses, necessitating revised scheduling and routing strategies. Despite these challenges, many agencies expressed optimism about their capacity to adapt. Funding availability emerged as a critical factor influencing the transition to ZEVs. While agencies welcomed increased financial support, particularly from the Low or No Emission Grant Program (Lo-No), concerns about the sustainability of this funding and the ongoing operational costs were prevalent. The need for a comprehensive funding inventory was underscored to ensure transit agencies are aware of all available resources. Technological constraints were significant barriers to ZEV adoption. The limited range of BEBs was frequently cited as a concern, leading to operational challenges and reliability issues. Agencies reported difficulties in sourcing replacement parts, which exacerbated downtime and maintenance challenges. Workforce development and training were identified as pivotal for a successful transition. Many agencies rely heavily on manufacturers for technician training, highlighting the need for scalable training programs that equip staff with the necessary skills to maintain electric powertrains effectively. This assessment offers actionable recommendations for the Joint Office, including enhancing outreach to transit agencies, developing resources for effective utility partnerships, and facilitating comprehensive training programs. Establishing a zero-emission bus evaluation program to track performance metrics such as cost, range, and reliability could provide valuable insights for transit agencies. The needs assessment provides a detailed examination of the challenges and opportunities facing transit agencies in their transition to zero-emissions bus fleets. By addressing these issues through targeted support, stakeholders can collaboratively work towards a cleaner, more sustainable public transportation system that benefits all communities.

33 - ADVANCED PROPULSION SYSTEMS↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Introducing the GeoRePORT Resource Size Tool: Reporting on Geothermal Resource Size Estimations Using the Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT): Preprint

The Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT) was developed with funding from the U.S. Department of Energy Geothermal Technologies Office to assist in identifying and pursuing long-term investment strategies through the development of a resource reporting protocol. The assessment protocols used in GeoRePORT allow for comparison of project attributes across locations and geological settings to understand the feasibility of geothermal development. This work introduces the Resource Size Tool, a new feature within the GeoRePORT package that compiles two independent methods for estimating geothermal resource size in terms of energy capacity in MW. Energy production potential for twenty-three case studies was estimated with the Resource Size Tool in order to 1) generate a reasonable range of resource size estimates for a particular geothermal field; 2) illustrate the advantages and limitations of each methodology (such as data input requirements, estimate accuracy and precision, and the appropriate circumstances of use); and 3) test the ability of the resource size tool to provide useful and accurate information for geothermal stakeholders. The tool employs two methods widely used in the geothermal industry: (1) USGS Volumetric and (2) Power Density. Results from our case studies show general overlap between these two methods in terms of resource size estimates; however, they also reveal key differences between the two approaches that should be considered when using such estimates to drive development. First, the two methods rely on different input parameters and therefore one method may be more appropriate and/or accurate for a given project than the other. Second, the Power Density method was found to generate wider ranges of resource size predictions, more consistently aligning with actual power production of the field but with larger scales of error; whereas the USGS Volumetric method predicts narrower ranges but tends to overestimate when compared to current MW production. Future work will refine variables used in the methods with input data from other sections of GeoRePORT and modify uncertainty levels based on the particular datasets used for a given project.

geological↗

Identifying the Role of Magnesium Content in Assessing the Electrochemical Performance of (CoCuMgNiZn)O

High-entropy oxides (HEOs) featuring 5 or more metals in approximately equimolar ratios, such as the prototypical rock-salt-structured (CoCuMgNiZn)O, have attracted interest for their potential to display material properties superior to oxides with combinations of 4 or fewer of the component metals. In particular, (CoCuMgNiZn)O has shown promise as an anode for lithium-ion batteries with a high specific capacity retention over extended cycling. Previous studies have suggested that magnesium, despite being electrochemically inert, provides a crucial contribution to the favorable performance of this HEO by stabilizing the crystal structure through repeated charge–discharge cycles. This paper probes the extent and mechanism of the magnesium effect by using a facile microwave-assisted hydrothermal synthesis method to vary the level of Mg content. Moreover, we extensively characterized the product with techniques such as 4D-STEM and ICP-OES, which have not previously been applied in combination with this material, in order to elucidate the relationships among chemical composition, nanostructure, and performance. Here, we show that the level of Mg incorporation is positively correlated with long-term stability and negatively correlated with rate capacity, and that the latter effect yields a stronger influence upon the overall performance, with the best-performing sample possessing a Mg quantity equivalent to ∼1/5 that of an equimolar concentration. This finding demonstrates not only that the variation of individual elemental levels offers a promising and relatively unexplored avenue to optimize the electrochemical performance of HEO materials but also that it should not be assumed that equimolar compositions of constituent elements are necessarily the best.

36 MATERIALS SCIENCE↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic and life cycle assessment of standalone Single-Stream material recovery facilities in the United states

Material Recovery Facilities (MRFs) are crucial players in achieving a circular economy. MRFs receive complex waste streams and separate valuable recyclables from these mixtures. This study conducts techno-economic analysis (TEA) to estimate the net present value (NPV) and life cycle assessment (LCA) to estimate different environmental impacts of a commercial scale standalone, single-stream MRF to assess the economic feasibility and environmental impacts of recovering valuable recyclables from an MRF processing 120,000 tonnes per year (t/y). The TEA employs a discounted cash flow rate of return (DCFROR) analysis over a 20-year facility lifetime, along with a sensitivity analysis on the impact of different operating and economic parameters. Results show that the total fixed cost of building the MRF facility is $\$ $23 MM, and the operating cost is $\$ $45.48/tonne. Further the NPV of the MRF can vary from $\$ $3.57 MM to $\$ $60 MM, while 100-year global warming potential can range from 5.98 to 8.53 kg carbon dioxide equivalents (CO2-eq) per tonne of MSW. We have also found that MSW composition (arising from regional effects) significantly impacts costs, 100-year global warming potential, and other impact categories such as acidification potential, eutrophication potential, ecotoxicity, ozone depletion, photochemical oxidation, carcinogenic effects, and non-carcinogenic effects. Sensitivity and uncertainty analysis indicate that waste composition and market prices significantly impact the profitability of the MRF, and the waste composition mostly impacts global warming potential. Our analysis also indicates that facility capacity, fixed capital cost, and waste tipping fees are vital parameters that affect the economic viability of MRF operations.

36 MATERIALS SCIENCE↗

Economic feasibility of in-motion wireless power transfer in a high-density traffic corridor

Electricity is expected to become a dominant power source in the transportation sector, but under a stationary recharging model, electric powered vehicles still suffer some disadvantages relative to conventional vehicles. Recent developments in wireless power transfer (WPT) technology can enable an alternative vehicle recharging model wherein power is supplied to vehicles while they are moving, mitigating the need for charging stops and high-capacity on-board energy storage. One of the greatest concerns associated with dynamic WPT is that the required infrastructure costs would be prohibitively high; however, the life-cycle costs and benefits of such a system have been under-researched. Here in this work, we apply a systems-level assessment to a case study of a WPT charging system located on the densely trafficked I-710 corridor in Los Angeles, California. Detailed cost estimates for electronics and implementation, high-fidelity energy consumption modeling, and survey-derived adoption projections are applied to evaluate scenarios of economic feasibility and environmental impact. Results show that a “1st-of-a-kind” system can achieve a payback in 20 years while maintaining operating cost advantages relative to petroleum fueling. System economics are shown to improve substantially with “nth-of-a-kind” capital costs. Discussion focuses on the effect of uptake trajectory on economic viability and detailed economics outcomes for light duty and heavy duty vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Network upgrade exploiting multi band: S- or E-band?

Nowadays, the fiber spectrum is only partially exploited, i.e., mainly in the C-band and more recently in the C + L-band, where the fiber attenuation profile experiences the minimum. Thus, fiber communications technology—amplifiers, switching, transceivers, etc.—and networking solutions are mature for those spectrum bands. However, the continuous increase in traffic means that capacity saturation of the current infrastructure is looming. Taking advantage of the unused portions of the spectrum (e.g., the S- and E-bands) may be an efficient solution to accommodate an increase in traffic without installing new fibers. Research is thus investigating multi-band transmission and networking to evaluate and enable such network upgrades. Some issues need to be solved or taken into account, from the enabling technology (e.g., amplifiers in the S- or E-band are still under development) to physical layer effects previously neglected, such as stimulated Raman scattering (SRS). SRS affects wideband transmission, potentially degrading active channels. The contribution of this paper is the investigation of network upgrades for C + L-band systems. In particular, upgrades exploiting the E- and S-bands are compared taking into account each band capacity and the effects of SRS on both new and already deployed channels (in both the C- and L-bands). A detailed analysis of the physical layer is provided also in the presence of guard bands between previously exploited bands and the bands used for upgrade. By leveraging the physical layer assessment, a networking analysis is carried out to evaluate the supported traffic increase and also the signal quality degradation due to SRS on active channels. Overall, the results suggest that upgrades to the E- and S-bands support a comparable increase in traffic. However, the exploitation of the E-band with 14 THz of guard band between the C- and E-bands may avoid detrimental effects to already active channels in the C + L-band, suggesting this upgrade strategy can be the most effective of the two.

47 OTHER INSTRUMENTATION↗

University of Minnesota, Twin Cities Final Scientific/Technical Report Small Scale Ammonia Synthesis Using Stranded Wind Energy

Ammonia absorber columns offer an alternative separation unit to replace condensation in the Haber-Bosch synthesis loop. Metal halide salts can selectively separate ammonia from the reactor outlet gas mixture and incorporate it into their crystal lattice with remarkably high thermodynamic capacity. While the salts’ working capacity can be limited and unstable when they are in their pure form, the capacity is stable and can be high when using a porous ceramic support. In this project, we found optimal conditions for sorbent fabrication, we demonstrated benchmark levels of uptake and release of ammonia, and we fabricated and demonstrated a prototype at a scale of 1 kg/day ammonia. This task allowed us to assess improvement in the techno-economic prospects for this new separation approach, making viable more distributed production of green ammonia from geographically dispersed renewable energy sources.

08 HYDROGEN↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗