Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

NuSTAR observations of X-ray bursts from the magnetar 1E 1048.1–5937

We report the detection of eight bright X-ray bursts from the 6.5 s magnetar 1E 1048.1–5937, during a 2013 July observation campaign with the Nuclear Spectroscopic Telescope Array. We study the morphological and spectral properties of these bursts and their evolution with time. The bursts resulted in count rate increases by orders of magnitude, sometimes limited by the detector dead time, and showed blackbody spectra with kT ∼ 6-8 keV in the T{sub 90} duration of 1-4 s, similar to earlier bursts detected from the source. We find that the spectra during the tail of the bursts can be modeled with an absorbed blackbody with temperature decreasing with flux. The burst flux decays followed a power law of index 0.8-0.9. In the burst tail spectra, we detect a ∼13 keV emission feature, similar to those reported in previous bursts from this source as well as from other magnetars observed with the Rossi X-ray Timing Explorer. We explore possible origins of the spectral feature such as proton cyclotron emission, which implies a magnetic field strength of B ∼ 2 × 10{sup 15} G in the emission region. However, the consistency of the energy of the feature in different objects requires further explanation.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CYCLES OF {alpha} CENTAURI

The main AB pair of the nearby {alpha} Centauri triple system has one of the most extensive X-ray records of any cosmic object, stretching over 30 years. The primary, {alpha} Cen A (G2 V), is a near twin of the Sun, with a similarly soft (1-2 MK) corona. The secondary, {alpha} Cen B (K1 V), is more active than the Sun, with a generally harder coronal spectrum. Here, more than a decade of spatially resolved measurements from ROSAT, XMM-Newton, and Chandra are compared on a common basis, with careful attention to conversion factors that translate count rates of the different instruments into absolute energy fluxes. For the latter purpose, two epochs of Chandra transmission grating spectra, which fully resolve the binary, were modeled using a differential emission measure formalism. The aggregate time series suggests that {alpha} Cen B was near X-ray maximum in the mid-1990s, minimum in the late-1990s, then peaked again in 2004-2005, and more recently has been declining toward another minimum. Meanwhile, {alpha} Cen A showed minimal variability 1995-2000, and like the secondary presently is mired in an activity lull (in fact, as seen by XMM-Newton, the primary 'fainted' from view in the 2005 time frame). Comparisons between X-ray luminosities in the 0.2-2 keV (6-60 A) ROSAT 'WGACAT' band and a softer counterpart 0.06-1.2 keV (10-200 A) reinforce the idea that cycle depth is strongly dependent on the energy span of the measurement, and that much of the coronal luminosity of cool-corona objects like the Sun falls at longer wavelengths than are recorded efficiently by contemporary instruments. Consequently, one must be careful in discussing X-ray cycles, their amplitudes, and coronal heating requirements unless one can demonstrate good control over the out-of-band component.

79 ASTRONOMY AND ASTROPHYSICS↗

Deadtime Calculations of Liquid Scintillator Neutron Detector Using Attenuation Law

Scientists have been working on deadtime problems for radiation detectors since 1940's. In detector systems, a minimum time must separate two different events before they can be measured individually. That minimum time interval is called to be deadtime of detector system. There are two commonly deadtime models: the paralyzing and the non-paralyzing models. Paralyzing model assumes that each event during the deadtime will reset the deadtime and deadtime extension will depend on the count rate. According to the non-paralyzing model, deadtime is fixed after each detected event and all events occurring during deadtime are lost. In this study, deadtime measurements have been obtained for an N-Probe fast neutron (NE-213 Liquid Scintillation) detector manufactured by BTI (Bubble Technology Industries) using a combination of the attenuation law and the assumption of ideal paralyzing and non-paralyzing method. Bubble Technology Industries (BTI) has manufactured a portable neutron scintillation spectrometer (N-Probe) with potential applications at nuclear reactor facilities, waste processing operations, and spent fuel storage areas. The deadtime of the N-Probe detector is not provided by the manufacturer; BTI, and there is no other study published on the N-Probe detector' deadtime. Since the detector will be used in future nuclear fuel investigations, it is important to determine the detector' deadtime for accurate nuclear fuel analysis. The deadtime of the BTI N-Probe was examined using different thicknesses of Plexiglas at the Missouri University of Science and Technology Reactor (MSTR) using attenuation law and average macroscopic cross-section of Plexiglas defined by both paralyzing and non-paralyzing model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A SURVEY OF HIGH-CONTRAST STELLAR FLARES OBSERVED BY CHANDRA

The X-ray light curves of pre-main-sequence (PMS) stars can show variability in the form of flares altering a baseline characteristic activity level; the largest X-ray flares are characterized by a rapid rise to more than 10 times the characteristic count rate, followed by a slower quasi-exponential decay. Analysis of these high-contrast X-ray flares enables the study of the innermost magnetic fields of PMS stars. We have scanned the ANCHORS database of Chandra observations of star-forming regions to extend the study of flare events on PMS stars both in sky coverage and in volume. We developed a sample of 30 high-contrast flares out of the 14,000 stars of various ages and masses available in ANCHORS at the start of our study. Applying methods of time-resolved spectral analysis, we obtain the temperatures, confining magnetic field strengths, and loop lengths of these bright, energetic flares. The results of the flare analysis are compared to the Two Micron All Sky Survey and Spitzer data available for the stars in our sample. We find that the longest flare loop lengths (of order several stellar radii) are only seen on stars whose IR data indicates the presence of disks. This suggests that the longest flares may stretch all the way to the disk. Such long flares tend to be more tenuous than the other large flares studied. A wide range of loop lengths are observed, indicating that different types of flares may occur on disked young stellar objects.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY FLARING ACTIVITY OF MRK 421 IN THE FIRST HALF OF 2013

We present the results of the Swift and NuSTAR observations of the nearby BL Lac object Mrk 421 during 2013 January–June. The source exhibited a strong long-term variability in the 0.3–10 keV and 3–79 keV bands with the maximum-to-minimum daily-binned flux ratios of 22 and 95, respectively, in about 3 months, mainly due to unprecedented strong X-ray outbursts by more than an order of magnitude in both bands within 2 weeks in 2013 April when the 0.3–10 keV count rate exceeded the level of 200 cts s{sup −1} for the first time, and Mrk 421 became one of the brightest sources in the X-ray sky. The source was also very active on intra-day timescales, and it showed flux doubling and halving timescales of 1.16–7.20 hr and 1.04–3.54 hr, respectively. On some occasions, the flux varied by 4%–23% within 300–840 s. During this period, the source also exhibited some of the most extreme X-ray spectral variability ever reported for BL Lacs—the location of the synchrotron spectral energy distribution peak shifted from a few eV to ∼10 keV, and the photon index at 1 keV and curvature parameter varied on timescales from a few weeks down to intervals shorter than 1 ks. MAGIC and First G-APD Cherenkov Telescope observations also revealed a very strong very high energy (VHE) flare during April 11–17. The UV and HE γ -ray flares were much weaker compared to their X-ray counterparts, and they generally showed significantly stronger correlation with each other than with the X-ray fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

LOW-FREQUENCY OSCILLATIONS IN XTE J1550-564

We present the results of a timing analysis of the low-frequency quasi-periodic oscillation (QPO) in the Rossi X-Ray Timing Explorer data of the black hole binary XTE J1550-564 during its 1998 outburst. The QPO frequency is observed to vary on timescales between {approx}100 s and days, correlated with the count rate contribution from the optically thick accretion disk: we studied this correlation and discuss its influence on the QPO width. In all observations, the quality factors ({nu}{sub 0}/FWHM) of the fundamental and second harmonic peaks were observed to be consistent, suggesting that the quasi-periodic nature of the oscillation is due to frequency modulation. In addition to the QPO and its harmonic peaks, a new 1.5{nu} component was detected in the power spectra. This component is broad, with a quality factor of {approx}0.6. From this, we argue that the peak observed at half the QPO frequency, usually referred to as 'sub-harmonic', could be the fundamental frequency, leading to the sequence 1:2:3:4. We also studied the energy dependence of the timing features and conclude that the two continuum components observed in the power spectrum, although both more intense at high energies, show a different dependence on energy. At low energies, the lowest-frequency component dominates, while at high energies the higher-frequency one has a higher fractional rms. An interplay between these two components was also observed as a function of their characteristic frequency. In this source, the transition between the low/hard state and the hard-intermediate state appears to be a smooth process.

79 ASTRONOMY AND ASTROPHYSICS↗

SWIFT X-RAY OBSERVATIONS OF CLASSICAL NOVAE. II. THE SUPER SOFT SOURCE SAMPLE

The Swift gamma-ray burst satellite is an excellent facility for studying novae. Its rapid response time and sensitive X-ray detector provides an unparalleled opportunity to investigate the previously poorly sampled evolution of novae in the X-ray regime. This paper presents Swift observations of 52 Galactic/Magellanic Cloud novae. We included the X-Ray Telescope (0.3-10 keV) instrument count rates and the UltraViolet and Optical Telescope (1700-8000 A) filter photometry. Also included in the analysis are the publicly available pointed observations of 10 additional novae the X-ray archives. This is the largest X-ray sample of Galactic/Magellanic Cloud novae yet assembled and consists of 26 novae with Super Soft X-ray emission, 19 from Swift observations. The data set shows that the faster novae have an early hard X-ray phase that is usually missing in slower novae. The Super Soft X-ray phase occurs earlier and does not last as long in fast novae compared to slower novae. All the Swift novae with sufficient observations show that novae are highly variable with rapid variability and different periodicities. In the majority of cases, nuclear burning ceases less than three years after the outburst begins. Previous relationships, such as the nuclear burning duration versus t{sub 2} or the expansion velocity of the eject and nuclear burning duration versus the orbital period, are shown to be poorly correlated with the full sample indicating that additional factors beyond the white dwarf mass and binary separation play important roles in the evolution of a nova outburst. Finally, we confirm two optical phenomena that are correlated with strong, soft X-ray emission which can be used to further increase the efficiency of X-ray campaigns.

79 ASTRONOMY AND ASTROPHYSICS↗

A VARIABLE BLACK HOLE X-RAY SOURCE IN AN NGC 1399 GLOBULAR CLUSTER

We have discovered an accreting black hole (BH) in a spectroscopically confirmed globular cluster (GC) in NGC 1399 through the monitoring of its X-ray activity. The source, with a peak luminosity of L{sub X} {approx_equal} 2 x 10{sup 39} erg s{sup -1}, reveals an order of magnitude change in the count rate within {approx_equal}10 ks in a Chandra observation. The BH resides in a metal-rich [Fe/H] {approx_equal} 0.2 GC. After RZ 2109 in NGC 4472 this is only the second BH X-ray source in a GC confirmed via rapid X-ray variability. Unlike RZ 2109, the X-ray spectrum of this BH source did not change during the period of rapid variability. In addition to the short-term variability the source also exhibits long-term variability. After being bright for at least a decade since 1993, within a span of two years it became progressively fainter, and eventually undetectable, or marginally detectable, in deep Chandra and XMM-Newton observations. The source also became harder as it faded. The characteristics of the long-term variability in itself provide sufficient evidence to identify the source as a BH. The long-term decline in the luminosity of this object was likely not recognized in previous studies because the rapid variability within the bright epoch suppressed the average luminosity in that integration. The hardening of the spectrum accompanying the fading would also make this BH source indistinguishable from an accreting neutron star in some epochs. Therefore, some low-mass X-ray binaries identified as neutron-star accretors in snapshot studies of nearby galaxies may also be BHs. Thus, the discovery of the second confirmed BH in an extragalactic GC through rapid variability at the very least suggests that accreting BHs in GCs are not exceedingly rare occurrences.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of target-to-background ratio, target size, emission scan duration, and activity on physical figures of merit for a 3D LSO-based whole body PET/CT scanner

The aim of our work is to describe the way in which physical figures of merit such as contrast-to-noise ratio (CNR) behave when varying acquisition parameters such as emission scan duration (ESD) or activity at the start of acquisition (A{sub acq}) that in clinical practice can be selected by the user, or object properties such as target dimensions or target-to-background (T/B) ratio, which depend uniquely on the intrinsic characteristics of the object being imaged. Figures of merit, used to characterize image quality and quantitative accuracy for a 3D-LSO based PET/CT scanner, were studied as a function of ESD and A{sub acq} for different target sizes and T/B ratios using a multivariate approach in a wide range of conditions approaching the ones that can be encountered in clinical practice. An annular ring of water bags of 3 cm thickness was fitted over an IEC phantom in order to obtain counting rates similar to those found in average patients. The average scatter fraction (SF) of the modified IEC phantom was similar to the mean SF measured on patients with a similar scanner. A supplemental set of micro-hollow spheres was positioned inside the phantom. The NEMA NU 2-2001 scatter phantom was positioned at the end of the IEC phantom to approximate the clinical situation of having activity that extends beyond the scanner. The phantoms were filled with a solution of water and {sup 18}F (12 kBq/mL) and the spheres with various T/B ratios of 22.5, 10.3, and 3.6. Sequential imaging was performed to acquire PET images with varying background activity concentrations of about 12, 9, 6.4, 5.3, and 3.1 kBq/mL, positioned on the linear portion of the phantom's NECR curve, well below peak NECR of 61.2 kcps that is reached at 31.8 kBq/mL. The ESD was set to 1, 2, 3, and 4 min/bed. With T/B ratios of 3.6, 10.3, and 22.5, the 13.0, 8.1, and 6.5 mm spheres were detectable for the whole ranges of background activity concentration and ESD, respectively. The ESD resulted as the most significant predictor of CNR variance, followed by T/B ratio and the cross sectional area of the given sphere. Only last comes A{sub acq} with a weight more than halved with respect to ESD. Thus, raising ESD seems to be much more effective than raising A{sub acq} in order to obtain higher CNR, which is the physical figure of merit closely related with target detectability, at least in the simple task of the signal known exactly background known exactly model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of the performance of {sup 3}He alternative detectors with MCNPX

This paper describes the techniques that are available to calculate the performance of {sup 3}He alternative detectors using MCNPX. Calculations of the performance of safeguards detectors that use {sup 3}He have been successfully carried out for many years. In the case of coincidence or multiplicity counting, specific tallies have been implemented to calculate the Singles, Doubles and Triples counting rates. The implementation of the method was done in such a way that it equates every capture in some nuclide in the detection zone with the production of an electronic pulse from the detector. This is a very good approximation for {sup 3}He detectors and BF{sub 3} detectors. However it is not appropriate for detectors such as boron-lined proportional counters, in which the fraction of capture events leading to an electronic pulse above threshold is very dependent on the geometric arrangement, in particular the thickness and composition of the boron-containing layer. This paper gives calculations of the ideal pulse height distributions to be expected from different detector types and gives values for the probability, as a function of detector energy threshold, that a neutron capture reaction will cause an electronic pulse from the detector. This is termed the electronic efficiency. This electronic detection efficiency depends very little on the energy of the captured neutron, which in most practical cases are heavily weighted towards thermal energies. It does not depend on the position of the source neutron or moderation in the sample. For cases of interest to nuclear safeguards, measurement of uranium and plutonium in specially designed detectors, the spectrum of detected neutrons is fairly constant and thus the electronic detection efficiency becomes a detector constant. The paper discusses how the electronic detection efficiency needs to be included in the calculation of Singles, Doubles and Triples, and describes proposals to improve the tallying capability of MCNPX for such cases. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuSTAR J163433-4738.7: A fast X-ray transient in the galactic plane

During hard X-ray observations of the Norma spiral arm region by the Nuclear Spectroscopic Telescope Array (NuSTAR) in 2013 February, a new transient source, NuSTAR J163433-4738.7, was detected at a significance level of 8σ in the 3-10 keV bandpass. The source is consistent with having a constant NuSTAR count rate over a period of 40 ks and is also detected simultaneously by Swift at lower significance. The source is not significantly detected by NuSTAR, Swift, or Chandra in the days before or weeks after the discovery of the transient, indicating that the strong X-ray activity lasted between ∼0.5 and 1.5 days. Near-infrared imaging observations were carried out before and after the X-ray activity, but we are not able to identify the counterpart. The combined NuSTAR and Swift energy spectrum is consistent with a power law with a photon index of Γ=4.1{sub −1.0}{sup +1.5} (90% confidence errors), a blackbody with kT = 1.2 ± 0.3 keV, or a Bremsstrahlung model with kT=3.0{sub −1.2}{sup +2.1} keV. The reduced-χ{sup 2} values for the three models are not significantly different, ranging from 1.23 to 1.44 for 8 degrees of freedom. The spectrum is strongly absorbed with N{sub H}=(2.8{sub −1.4}{sup +2.3})×10{sup 23} cm{sup –2}, (9{sub −7}{sup +15})×10{sup 22} cm{sup –2}, and (1.7{sub −0.9}{sup +1.7})×10{sup 23} cm{sup –2}, for the power-law, blackbody, and Bremsstrahlung models, respectively. Although the high column density could be due to material local to the source, it is consistent with absorption from interstellar material along the line of sight at a distance of 11 kpc, which would indicate an X-ray luminosity >10{sup 34} erg s{sup –1}. Although we do not reach a definitive determination of the nature of NuSTAR J163433-4738.7, we suggest that it may be an unusually bright active binary or a magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

NORM Concentration Determination in Common Materials in an Urban Environment

The United States government performs searches for illicit radiation sources before and during large special events, such as State of the Union addresses, presidential inaugurations, or the recent papal visit. Clear detection of sources is difficult due to natural background radiation, which can vary greatly throughout a given search area. Background radiation is mostly a function of the materials used in roadways, sidewalks, and building exteriors. A team of scientists from Oak Ridge National Laboratory (ORNL), Lawrence Livermore National Laboratory (LLNL), the Remote Sensing Laboratory (RSL), and Lawrence Berkeley National Laboratory (LBNL) is exploring the nature and variability of background count rates in order to improve the performance of searches in urban areas. A series of background measurements have been and will continue to be taken at a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site replicates a small town with asphalt roads, concrete intersections, buildings, sidewalks, curbs, and gravel parking areas. Unlike an actual urban area, traffic and pedestrian access can be easily controlled to avoid interference with measurements. This paper documents the efforts focused on characterizing the various concentrations of radioactive material found in these materials at the site. The NORM concentrations determined from this work will be incorporated in to a large-scale simulation (a 'virtual test-bed') that can be used to investigate various search techniques and algorithms, detector suite configurations, and to produce representative synthetic data for future work. A combination of measurement and simulation was used to determine the concentration of {sup 40}K and the radioactive nuclides in the uranium series and the thorium series in several materials at the FTIG MOUT site. The predicted concentrations are consistent with other published results, and they matched favorably with synthetic data generated with MCNP6 models using the determined NORM concentrations and estimates of the FTIG environment as described by available construction plans and using standard material assumptions. Future measurements will incorporate lessons learned from this study. More measurements will be made of the concrete intersections at the site. The methodology explained in this report will also be carried out on building materials in an effort to characterize NORM concentrations in these background sources. Other modeling and simulation work that should be conducted includes a robust sensitivity analysis in which the effects of small changes to the model (and measurement) system can be characterized to help bound the uncertainty on the final NORM concentration predictions. (authors)

54 ENVIRONMENTAL SCIENCES↗

REVISITING THE SHORT-TERM X-RAY SPECTRAL VARIABILITY OF NGC 4151 WITH CHANDRA

We present new X-ray spectral data for the Seyfert 1 nucleus in NGC 4151 observed with Chandra for {approx}200 ks. A significant ACIS pileup is present, resulting in a nonlinear count rate variation during the observation. With pileup corrected spectral fitting, we are able to recover the spectral parameters and find consistency with those derived from unpiled events in the ACIS readout streak and outer region from the bright nucleus. The absorption corrected 2-10 keV flux of the nucleus varied between 6 x 10{sup -11} erg s{sup -1} cm{sup -2} and 10{sup -10} erg s{sup -1} cm{sup -2} (L{sub 2-10{sub keV}} {approx} 1.3-2.1 x 10{sup 42} erg s{sup -1}). Similar to earlier Chandra studies of NGC 4151 at a historical low state, the photon indices derived from the same absorbed power-law model are {Gamma} {approx} 0.7-0.9. However, we show that {Gamma} is highly dependent on the adopted spectral models. Fitting the power-law continuum with a Compton reflection component gives {Gamma} {approx} 1.1. By including passage of non-uniform X-ray obscuring clouds, we can reproduce the apparent flat spectral states with {Gamma} {approx} 1.7, typical for Seyfert 1 active galactic nuclei. The same model also fits the hard spectra from previous ASCA 'long look' observation of NGC 4151 in the lowest flux state. The spectral variability during our observation can be interpreted as variations in intrinsic soft continuum flux relative to a Compton reflection component that is from distant cold material and constant on short timescale, or variations of partially covering absorber in the line of sight toward the nucleus. An ionized absorber model with ionization parameter log {xi} {approx} 0.8-1.1 can also fit the low-resolution ACIS spectra. If the partial covering model is correct, adopting a black hole mass M{sub BH{approx}}4.6x10{sup 7} M{sub sun} we constrain the distance of the obscuring cloud from the central black hole to be r {approx_lt} 9 lt-day, consistent with the size of the broad emission line region of NGC 4151 from optical reverberation mapping.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of Strong Resonant Behavior in the Inverse Photoelectron Spectroscopy of Ce Oxide

X-ray Emission Spectroscopy (XES) and Resonant Inverse Photoelectron Spectroscopy (RIPES) have been used to investigate the photon emission associated with the Ce3d5/2 and Ce3d3/2 thresholds. Strong resonant behavior has been observed in the RIPES of Ce Oxide near the 5/2 and 3/2 edges. Inverse Photoelectron Spectroscopy (IPES) and its high energy variant, Bremstrahlung Isochromat Spectroscopy (BIS), are powerful techniques that permit a direct interrogation of the low-lying unoccupied electronic structure of a variety of materials. Despite being handicapped by counting rates that are approximately four orders of magnitude less that the corresponding electron spectroscopies (Photoelectron Spectroscopy, PES, and X-ray Photoelectron Spectroscopy, XPS) both IPES and BIS have a long history of important contributions. Over time, an additional variant of this technique has appeared, where the kinetic energy (KE) of the incoming electron and photon energy (hv) of the emitted electron are roughly the same magnitude as the binding energy of a core level of the material in question. Under these circumstances and in analogy to Resonant Photoelectron Spectroscopy, a cross section resonance can occur, giving rise to Resonant Inverse Photoelectron Spectroscopy or RIPES. Here, we report the observation of RIPES in an f electron system, specifically the at the 3d{sub 5/2} and 3d{sub 3/2} thresholds of Ce Oxide. The resonant behavior of the Ce4f structure at the 3d thresholds has been addressed before, including studies of the utilization of the technique as a probe of electron correlation in a variety of Ce compounds. Interestingly, the first RIPES work on rare earths dates back to 1974, although under conditions which left the state of the surface and near surface regions undefined. Although they did not use the more modern terminology of 'RIPES,' it is clear that RIPES was actually first performed in 1974 by Liefeld, Burr and Chamberlain on both La and Ce based materials. In these experiments, the La and Ce metallic samples were attached to the anode of an x-ray tube and the x-ray emission characteristics were measured using a two crystal monochromator. The pressure in the x-ray tube was quoted as being below 2 x 10{sup -8} Torr. They did indeed observed resonant behavior at the M{alpha} (3d{sub 5/2}) and M{beta} (3d{sub 3/2}) thresholds. In fact, our results here will confirm the measurements made upon the Ce based sample used in by Liefeld et al. However, the state of the Ce sample surface and near surface regions are quite undefined in the study in Ref 9. For example, the authors suggest that they are probing Ce metal, since they cannot see any evidence of an OK{alpha} (1s) XES line. However, they do report the observation of FK{alpha} (1s) line, possibly due to the utilization of cerium fluoride in the sample preparation. Later, they tried to address these issues in a new ultrahigh vacuum system. Based upon our results, it is clear that their original sample surface was oxidized, using the word here in its more general context as in having lost electrons to the oxidizing agent, although whether the structure is an oxide or fluoride remains unclear. In any case, the primacy of Liefeld and coworkers in these measurements should be noted. Cerium and cerium oxide have been studied with a variety of spectroscopic techniques under UHV conditions. This includes Bremstrahlung Isochromat Spectroscopy or BIS, Photoelectron Spectroscopy, X-ray Absorption Spectroscopy, Electron Energy Loss Spectroscopy and Resonant XES, to name just a few. We will compare our results to those of other spectroscopies.

36 MATERIALS SCIENCE↗

Feasibility of Amorphous Selenium Based Photon Counting Detectors for Digital Breast Tomosynthesis

Amorphous selenium (a-Se) has been incorporated successfully in direct conversion flat panel x-ray detectors, and has demonstrated superior image quality in screening mammography and digital breast tomosynthesis (DBT) under energy integration mode. The present work explores the potential of a-Se for photon counting detectors in DBT. We investigated major factors contributing to the variation in the charge collected by a pixel upon absorption of each x-ray photon. These factors included x-ray photon interaction, detector geometry, charge transport, and the pulse shaping and noise properties of the photon counting readout circuit. Experimental measurements were performed on a linear array test structure constructed by evaporating an a-Se layer onto an array of 100 {mu}m pitch strip electrodes, which are connected to a 32 channel low noise photon counting integrated circuit. The measured pulse height spectrum (PHS) under polychromatic xray exposure was interpreted quantitatively using the factors identified. Based on the understanding of a-Se photon counting performance, design parameters were proposed for a 2D detector with high quantum efficiency and count rate that could meet the requirements of photon counting detector for DBT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

DISCOVERY OF X-RAY EMISSION IN THE OLD CLASSICAL NOVA DK LACERTAE

We report the discovery of X-ray emission at the position of the old classical nova DK Lacertae using the Swift satellite. Three observations were conducted using the X-Ray Telescope 62 years after the discovery of the nova, yielding 46 source signals in an exposure time of 4.8 ks. A background-subtracted count rate was 9 {+-} 2 Multiplication-Sign 10{sup -3} counts s{sup -1}, corresponding to a detection significance level of 5{sigma}. The X-ray spectrum was characterized by a continuum extending up to about 7 keV, which can be modeled by a power-law component with a photon index of 1.4-5.6, or by a thermal bremsstrahlung component with a temperature of 0.7-13.3 keV, convolved with interstellar absorption with an equivalent hydrogen column density of 0.3-2.4 Multiplication-Sign 10{sup 22} cm{sup -2}. Assuming a distance of 3900 pc to the source, the luminosity was 10{sup 32}-10{sup 34} erg s{sup -1} in the 0.3-10 keV energy band. The origin of X-rays is considered to be either mass accretion on the white dwarf or adiabatic shocks in nova ejecta, with the former appearing much more likely. In either case, DK Lacertae represents a rare addition to the exclusive club of X-ray emitting old novae.

79 ASTRONOMY AND ASTROPHYSICS↗

The Explorer XVI Micrometeoroid Satellite: Description and Preliminary Results for the Period December 16, 1962 Through January 13, 1963

Explorer XVI (1962 Beta Chi l) data that have been analyzed for the period between December 16, 1962 (launch date), and January 13, 1963, indicate that the orbit achieved was close to the predicted orbit. Ten punctures of annealed 0.001-inch-thick beryllium-copper have been used to determine a puncture rate of 0.035 per square foot per day in this material. One puncture of a 0.002-inch-thick sample has also occurred in this period. A tentative evaluation of the puncture rate for the 0.001-inch beryllium-copper in terms of the rate for an equivalent thickness of aluminum has been attempted, and the result has been compared with two different puncture rate estimates. The three micrometeoroid impact detecting systems are operating. Counting rates for the high- and low-sensitivity systems were close to anticipated values near the end of one week. Two of the 0.001-inch-steel-covered grid detectors have been punctured, but none of the 0.003- or 0.006-inch-steel-covered grid detectors have indicated punctures. One of the cadmium sulfide cells indicates three punctures of the 0.00025-inch Mylar cover. None of the 0.002- or 0.003-inch-copper-wire cards have indicated a break in the period covered. Telemetry temperatures were initially higher than expected although they remained well within operating limits. Sensor temperatures have remained within the expected bounds.

Micrometeoroid↗