Choroidal vasculature characteristics based choroid segmentation for enhanced depth imaging optical coherence tomography images

Purpose: In clinical research, it is important to measure choroidal thickness when eyes are affected by various diseases. The main purpose is to automatically segment choroid for enhanced depth imaging optical coherence tomography (EDI-OCT) images with five B-scans averaging. Methods: The authors present an automated choroid segmentation method based on choroidal vasculature characteristics for EDI-OCT images with five B-scans averaging. By considering the large vascular of the Haller’s layer neighbor with the choroid-sclera junction (CSJ), the authors measured the intensity ascending distance and a maximum intensity image in the axial direction from a smoothed and normalized EDI-OCT image. Then, based on generated choroidal vessel image, the authors constructed the CSJ cost and constrain the CSJ search neighborhood. Finally, graph search with smooth constraints was utilized to obtain the CSJ boundary. Results: Experimental results with 49 images from 10 eyes in 8 normal persons and 270 images from 57 eyes in 44 patients with several stages of diabetic retinopathy and age-related macular degeneration demonstrate that the proposed method can accurately segment the choroid of EDI-OCT images with five B-scans averaging. The mean choroid thickness difference and overlap ratio between the authors’ proposed method and manual segmentation drawn by experts were −11.43 μm and 86.29%, respectively. Conclusions: Good performance was achieved for normal and pathologic eyes, which proves that the authors’ method is effective for the automated choroid segmentation of the EDI-OCT images with five B-scans averaging.

60 APPLIED LIFE SCIENCES↗

SU-F-E-19: A Novel Method for TrueBeam Jaw Calibration

Purpose: A simple jaw calibration method is proposed for Varian TrueBeam using an EPID-Encoder combination that gives accurate fields sizes and a homogeneous junction dose. This benefits clinical applications such as mono-isocentric half-beam block breast cancer or head and neck cancer treatment with junction/field matching. Methods: We use EPID imager with pixel size 0.392 mm × 0.392 mm to determine the radiation jaw position as measured from radio-opaque markers aligned with the crosshair. We acquire two images with different symmetric field sizes and record each individual jaw encoder values. A linear relationship between each jaw’s position and its encoder value is established, from which we predict the encoder values that produce the jaw positions required by TrueBeam’s calibration procedure. During TrueBeam’s jaw calibration procedure, we move the jaw with the pendant to set the jaw into position using the predicted encoder value. The overall accuracy is under 0.1 mm. Results: Our in-house software analyses images and provides sub-pixel accuracy to determine field centre and radiation edges (50% dose of the profile). We verified the TrueBeam encoder provides a reliable linear relationship for each individual jaw position (R{sup 2}>0.9999) from which the encoder values necessary to set jaw calibration points (1 cm and 19 cm) are predicted. Junction matching dose inhomogeneities were improved from >±20% to <±6% using this new calibration protocol. However, one technical challenge exists for junction matching, if the collimator walkout is large. Conclusion: Our new TrueBeam jaw calibration method can systematically calibrate the jaws to crosshair within sub-pixel accuracy and provides both good junction doses and field sizes. This method does not compensate for a larger collimator walkout, but can be used as the underlying foundation for addressing the walkout issue.

60 APPLIED LIFE SCIENCES↗

SU-F-E-20: A Mathematical Model of Linac Jaw Calibration Integrated with Collimator Walkout

Purpose: Accurate jaw calibration is possible, but it does not necessarily achieve good junctions because of collimator rotation walkout. We developed a mathematical model seeking to pick an origin for calibration that minimizes the collimator walkout effect. Methods: We use radioopaque markers aligned with crosshair on the EPID to determine the collimator walkout at collimator angles 0°, 90° and 270°. We can accurately calibrate jaws to any arbitrary origin near the radiation field centre. While the absolute position of an origin moves with the collimator walkout, its relative location to the crosshair is an invariant. We studied two approaches to select an optimal origin. One approach seeks to bring all three origin locations (0°–90°–270°) as close as possible by minimizing the perimeter of the triangle formed by these points. The other approach focuses on the gap for 0°–90° junctions. Results: Our perimeter cost function has two variables and non-linear behaviour. Generally, it does not have zero-perimeter-length solution which leads to perfect jaw matches. The zero solution can only be achieved, if the collimator rotates about a single fixed axis. In the second approach, we can always get perfect 0°–0° and 0°–90° junctions, because we ignore the 0°–270° situation. For our TrueBeams, both techniques for selecting an origin improved junction dose inhomogeneities to less than ±6%. Conclusion: Our model considers the general jaw matching with collimator rotations and proposes two potential solutions. One solution optimizes the junction gaps by considering all three collimator angles while the other only considers 0°–90°. The first solution will not give perfect matching, but can be clinically acceptable with minimized collimator walkout effect, while the second can have perfect junctions at the expense of the 0°–270° junctions. Different clinics might choose between these two methods basing on their clinical practices.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-11: Implications for Online Adaptive and Non-Adaptive Radiotherapy of Gastic and Gastroesophageal Junction Cancers Using MRI-Guided Radiotherapy

Purpose: Radiotherapy for gastric and gastroesophageal junction (GEJ) tumors commonly requires large margins due to deformation, motion and variable changes of the stomach anatomy, at the risk of increased normal tissue toxicities. This work quantifies the interfraction variation of stomach deformation from daily MRI-guided radiotherapy to allow for a more targeted determination of margin expansion in the treatment of gastric and GEJ tumors. Methods: Five patients treated for gastric (n=3) and gastroesophageal junction (n=2) cancers with conventionally fractionated radiotherapy underwent daily MR imaging on a clinical MR-IGRT system. Treatment planning and contours were performed based on the MR simulation. The stomach was re-contoured on each daily volumetric setup MR. Dice similarity coefficients (DSC) of the daily stomach were computed to evaluate the stomach interfraction deformation. To evaluate the stomach margin, the maximum Hausdorff distance (HD) between the initial and fractional stomach surface was measured for each fraction. The margin expansion, needed to encompass all fractions, was evaluated from the union of all fractional stomachs. Results: In total, 94 fractions with daily stomach contours were evaluated. For the interfraction stomach differences, the average DSC was 0.67±0.1 for gastric and 0.62±0.1 for GEJ cases. The maximum HD of each fraction was 3.5±2.0cm (n=94) with mean HD of 0.8±0.4cm (across all surface voxels for all fractions). The margin expansion required to encompass all individual fractions (averaged across 5 patients) was 1.4 cm(superior), 2.3 cm(inferior), 2.5 cm(right), 3.2 cm(left), 3.7 cm(anterior), 3.4 cm(posterior). Maximum observed difference for margin expansion was 8.7cm(posterior) among one patient. Conclusion: We observed a notable interfractional change in daily stomach shape (i.e., mean DSC of 0.67, p<0.0001) in both gastric and GEJ patients, for which adaptive radiotherapy is indicated. A minimum PTV margin of 3 cm is indicated to account for interfraction stomach changes when adaptive radiotherapy is not available. M. Bassetti: Travel funding from ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Josephson junction with two superconducting current components

The properties of a Josephson junction with the 2π- and 4π-periodic superconducting current component have been analyzed. In the range of low voltages, such a junction exhibits the 4π periodicity of the phase difference for the Majorana current amplitude much smaller than the Josephson current, which makes it possible to observe Josephson current oscillations with a fractional period for small dissipation β < 1 in the hysteresis region. The effect the 4π-periodic Majorana current component is also manifested in a change in the sequence of steps in the ladder structure emerging on the current–voltage (I–V) characteristic of the junction. We have determined the interval of external electromagnetic radiation amplitudes, in which the manifestation of the fractional Josephson effect on the I–V characteristic is most significant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Origin of discrepancies in the experimental values of the barrier height at metal–semiconductor junctions

A possible explanation is suggested for discrepancies between experimental values obtained by different authors for the barrier height at the same metal–semiconductor junction. It is supposed that the problem is caused primarily by the structural inhomogeneity of the metal. As a result, the junction behaves as an assembly of a large number of subjunctions connected in parallel. To determine the effect of metal inhomogeneity on the properties of a junction, the dependence of the barrier height in a Schottky diode on the junction area is investigated under the assumption that, with an increase in the area of a junction between a singlecrystal semiconductor and a polycrystalline metal, the degree of inhomogeneity and, thus, the number of subjunctions, increases.

36 MATERIALS SCIENCE↗

High-power nano- and picosecond optoelectronic switches based on high-voltage silicon structures with p–n junctions: II. Energy efficiency

The energy efficiency of optoelectronic switches based on high-voltage silicon photodiodes, phototransistors, and photothyristors controlled by picosecond laser pulses during the formation of voltage pulses on resistive load R{sub L} is studied for the first time. It is shown that at the given values of the resistive load R{sub L}, pulse amplitude U{sub R} and duration t{sub R}, there exist optimum device areas, energies, and absorbances of control radiation providing a maximum total switch efficiency of ~0.92. All three switch types feature almost the same efficiency at short t{sub R}; at longer t{sub R}, photothyristors have a noticeable advantage.

36 MATERIALS SCIENCE↗

Formation of the Excess Free Volume in Triple Junctions during Nickel Crystallization

The formation of an excess free volume in triple junctions during crystallization has been studied by the molecular dynamics model using nickel as an example. It is shown that an excess free volume that forms during nickel crystallization in triple junctions predominantly forms as a result of the fixation of the liquid phase volume when contacting three crystallization fronts that contains, after crystallization, a high fraction of the free volume. In some cases, as the free volume is concentrated in triple junctions, a comparatively small crystalline subgrain (from one to several nanometers in diameter) forms, and the subgrain has the orientation different from those of contacting grains and exists in the extended state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Slot Lens Antenna Based on Thin Nb Films for the Wideband Josephson Terahertz Oscillator

Abstract—An oscillator based on the distributed tunnel superconductor-insulator-superconductor junction with an ultrawide operating bandwidth of up to 100% of the central frequency seems to be a promising type of directional source of continuous electromagnetic radiation in the terahertz frequency range. In this paper, we propose a scheme of a terahertz oscillator integrated on a single microchip with a transmitting lens antenna with the slot structure in a 200-nm Nb film to radiate the signal into the open space. We also proposed and numerically simulated several designs of a planar slot antenna matched (in the input) with a Josephson oscillator and (in the output) with a silicon elliptical lens. The obtained results of the matching of the oscillator output power with the antenna of various designs operating in four frequency ranges: 250–410, 330–570, 380–520, and 420–700 GHz are presented. The antenna beam patterns and impedances are calculated as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic-Force Microscopy of Resistive Nonstationary Signal Switching in ZrO{sub 2}(Y) Films

Local resistive switching by complex nonstationary signals in zirconium-dioxide-stabilized films on conducting substrates has been studied by atomic-force microscopy with a conducting probe. Film resistance was switched by triangular voltage pulses on which a high-frequency sinusoidal signal was superimposed. It is found that the ratio of currents through the junction between the probe and film surface in high-resistance and low-resistance states increases after the superposition of a sinusoidal signal (as compared to switching by simple triangular pulses). An increase in the temporal stability of the current strength in these states was also found when switching with a sinusoidal signal. This effect is associated with resonant activation of oxygen ion migration over vacancies in an external ac electric field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Functional Magnon Network Blocks Based on Structures with Translational Symmetry Violation

We have studied the properties of spin-wave excitations in a structure that is a junction of two regular magnon waveguides. The proposed structure enables the transmission of spin-wave signals in an irregular structure in the propagation mode of a surface magnetostatic wave. Using the method of micromagnetic simulation, the characteristics of the wave process have been calculated when changing the structure parameters, magnitude and direction of a magnetization field. It is shown that a system with translational symmetry violation can be used to transmit a signal in three-dimensional configurations of magnon networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generation of Terahertz Radiation in Magnetic Junctions Based on Nanowires

A system of spin-injection emitters employing magnetic junctions based on an array of parallel nanodimensional wires has been studied. Manufacturing technology and possible variants of the nanowire structure are discussed. Conditions of the formation of a new type of spin-injection emitters of terahertz radiation on this basis are considered. The design of the experimental setup is described, and the results of experiments are analyzed. It is established that signals in a 16–18 THz range can be generated by passing high-density current through the proposed nanowire array.

42 ENGINEERING↗

Development and Manufacture of Cost-Effective Composite Drill Pipe

Advanced Composite Products and Technology, Inc. (ACPT) has developed composite drill pipe (CDP) that matches the structural and strength properties of steel drill pipe, but weighs less than 50 percent of its steel counterpart. Funding for the multiyear research and development of CDP was provided by the U.S. Department of Energy Office of Fossil Energy through the Natural Gas and Oil Projects Management Division at the National Energy Technology Laboratory (NETL).

03 NATURAL GAS↗

RELAP-7 Progress Report: A Mathematical Model for 1-D Compressible, Single-Phase Flow Through a Branching Junction

In the literature, the abundance of pipe network junction models, as well as inclusion of dissipative losses between connected pipes with loss coefficients, has been treated using the incompressible flow assumption of constant density. This approach is fundamentally, physically wrong for compressible flow with density change. This report introduces a mathematical modeling approach for general junctions in piping network systems for which the transient flows are compressible and single-phase. The junction could be as simple as a 1-pipe input and 1-pipe output with differing pipe cross-sectional areas for which a dissipative loss is necessary, or it could include an active component, between an inlet pipe and an outlet pipe, such as a pump or turbine. In this report, discussion will be limited to the former. A more general branching junction connecting an arbitrary number of pipes with transient, 1-D compressible single-phase flows is also presented. These models will be developed in a manner consistent with the use of a general equation of state like, for example, the recent Spline-Based Table Look-up method [1] for incorporating the IAPWS-95 formulation [2] to give accurate and efficient calculations for properties for water and steam with RELAP-7 [3].

42 ENGINEERING↗

Electrical Components for Marine Renewable Energy Arrays: A Techno-Economic Review

This paper presents a review of the main electrical components that are expected to be present in marine renewable energy arrays. The review is put in context by appraising the current needs of the industry and identifying the key components required in both device and array-scale developments. For each component, electrical, mechanical and cost considerations are discussed; with quantitative data collected during the review made freely available for use by the community via an open access online repository. Here, this data collection updates previous research and addresses gaps specific to emerging offshore technologies, such as marine and floating wind, and provides a comprehensive resource for the techno-economic assessment of offshore energy arrays.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interaction of Two Active Region Filaments Observed by NVST and SDO

Using high spatial and temporal resolution H α data from the New Vacuum Solar Telescope (NVST) and simultaneous observations from the Solar Dynamics Observatory , we present the rare event of the interaction between two filaments (F1 and F2) in AR 11967 on 2014 January 31. The adjacent two filaments were almost perpendicular to each other. Their interaction was driven by the movement of F1 and started when the two filaments collided with each other. During the interaction, the threads of F1 continuously slipped from the northeast to the southwest, and were accompanied by the brightenings at the junction of two filaments and the northeast footpoint of F2. Part of F1 and the main body of F2 became invisible in H α wavelength due to the heating and the motion of F2. At the same time, bright material initiated from the junction of two filaments were observed to move along F1. The magnetic connectivities of F1 were found to be changed after their interaction. These observations suggest that magnetic reconnection was involved in the interaction of two filaments and resulted in the eruption of one filament.

79 ASTRONOMY AND ASTROPHYSICS↗

Entrepreneur Grows Microswitch Company

Todd Christenson took advantage of Sandia National Laboratories’ Entrepreneurial Separation to Transfer Technology (ESTT) program to start HT MicroAnalytical (HT Micro) in 2003 in order to apply his specialized expertise in high aspect ratio microfabrication (HARM) technology gained while at Sandia to the creation of the world’s smallest electromechanical switches.

42 ENGINEERING↗