Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Ab initio calculation of electron–phonon coupling in monoclinic β-Ga{sub 2}O{sub 3} crystal

The interaction between electrons and vibrational modes in monoclinic β-Ga{sub 2}O{sub 3} is theoretically investigated using ab-initio calculations. The large primitive cell of β-Ga{sub 2}O{sub 3} gives rise to 30 phonon modes all of which are taken into account in transport calculation. The electron-phonon interaction is calculated under density functional perturbation theory and then interpolated using Wannier–Fourier interpolation. The long-range interaction elements between electrons and polar optical phonon (POP) modes are calculated separately using the Born effective charge tensor. The direction dependence of the long-range POP coupling in a monoclinic crystal is explored and is included in the transport calculations. Scattering rate calculations are done using the Fermi golden rule followed by solving the Boltzmann transport equation using the Rode's method to estimate low field mobility. A room temperature mobility of 115 cm{sup 2}/V s is observed. Comparison with recent experimentally reported mobility is done for a wide range of temperatures (30 K–650 K). It is also found that the POP interaction dominates the electron mobility under low electric field conditions. The relative contribution of the different POP modes is analyzed and the mode 21 meV POP is found to have the highest impact on low field electron mobility at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio quantum scattering calculations for the CO–O 2 system and a new CO–O 2 potential energy surface: O 2 and air broadening of the R(0) line in CO

We present ab initio calculations of the collisional broadening of the R(0) pure rotational line in CO (at 115 GHz) perturbed by O 2 . Our calculations are done in a fully quantum way by solving close-coupling quantum-scattering equations without any approximations. We also report a new, highly accurate CO–O 2 potential energy surface on which we did the quantum-scattering calculations. The calculated collisional broadening agrees with the available experimental data in a wide temperature range. The calculated collisional shift is negligible compared to the broadening, which is also consistent with the experimental data. We combine this result with our previous calculations for the same line in CO perturbed by N 2 [Józwiak et al., J. Chem. Phys. 154, 054314 (2021)]; the obtained air-perturbed broadening of the R(0) pure rotational line in CO and its temperature dependence perfectly agree with the HITRAN database. This result constitutes an important step toward developing a methodology for providing accurate ab initio reference data on spectroscopic collisional line-shape parameters for molecular systems relevant to the Earth’s atmosphere and for populating spectroscopic line-by-line databases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy dependent calculations of fission product, prompt, and delayed neutron yields for neutron induced fission on 235 U, 238 U, and 239 Pu

In this article, we perform energy-dependent calculations of independent and cumulative fission product yields for 235 U, 238 U, and 239 Pu in the first chance fission region. Starting with the primary fission fragment distributions taken from available experimental data and analytical functions based on assumptions for the excitation energy and spin-parity distributions, the Hauser-Feshbach statistical decay treatment for fission fragment de-excitation is applied to more than 1,000 fission fragments for the incident neutron energies up to 5 MeV. The calculated independent yields are then used as an input of β-decay calculations to produce the cumulative yield, and summation calculations are performed. Model parameters in these procedures are adjusted by applying the Bayesian technique at the thermal energy for 235 U and 239 Pu and in the fast energy range for 238 U. The calculated fission observable quantities, such as the energy-dependent cumulative yields, and prompt and delayed neutron yields, are compared with available experimental data. We also study the possible impact of the second chance fission opening on the energy dependence of the delayed neutron yield by on the opening of second chance fission on the energy dependence calculation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of state-interaction and spinor-representation calculations of spin-orbit coupling within exact two-component coupled-cluster theories

Here a benchmark study of state-interaction and spinor-representation calculations of spin-orbit coupling using the exact two-component Hamiltonians with atomic mean-field integrals (the X2CAMF schemes) at the equation-of-motion coupled-cluster singles and doubles level is reported. We adopt a version of the X2CAMF scheme with spin-orbit integrals correct to first order for the state-interaction calculations and a version correct to infinite order for the spinor-representation calculations. The differences between the state-interaction calculations with minimum active spaces to account for (quasi-)degeneracy and the spinor-representation calculations thus correspond to higher-order spin-orbit contributions. This state-interaction approach with scalar-relativistic effects accurately included in the reference functions and in the spin-orbit integrals is shown to exhibit robust performance for elements across the periodic table. On the other hand, the more rigorous spinor representation shows more rapid convergence with respect to the number of correlated electrons and is the preferred choice for accurate calculations for heavy elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DeepMC: a deep learning method for efficient Monte Carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy

Abstract Emerging magnetic resonance (MR) guided radiotherapy affords significantly improved anatomy visualization and, subsequently, more effective personalized treatment. The new therapy paradigm imposes significant demands on radiation dose calculation quality and speed, creating an unmet need for the acceleration of Monte Carlo (MC) dose calculation. Existing deep learning approaches to denoise the final plan MC dose fail to achieve the accuracy and speed requirements of large-scale beamlet dose calculation in the presence of a strong magnetic field for online adaptive radiotherapy planning. Our deep learning dose calculation method, DeepMC, addresses these needs by predicting low-noise dose from extremely noisy (but fast) MC-simulated dose and anatomical inputs, thus enabling significant acceleration. DeepMC simultaneously reduces MC sampling noise and predicts corrupted dose buildup at tissue-air material interfaces resulting from MR-field induced electron return effects. Here we demonstrate our model’s ability to accelerate dose calculation for daily treatment planning by a factor of 38 over traditional low-noise MC simulation with clinically meaningful accuracy in deliverable dose and treatment delivery parameters. As a post-processing approach, DeepMC provides compounded acceleration of large-scale dose calculation when used alongside established MC acceleration techniques in variance reduction and graphics processing unit-based MC simulation.

Engineering↗

All-order perturbation calculation of energies, hyperfine constants, multipole polarizabilities, and blackbody radiation shift in {sup 87}Sr{sup +}

Excitation energies of the [Kr]ns{sub 1/2}, [Kr]np{sub j}, [Kr]nd{sub j}, and [Kr]nf{sub j} (n{<=}9 and [Kr]=(1s{sup 2}2s{sup 2}2p{sup 6}3s{sup 2}3p{sup 6}3d{sup 10}4s{sup 2}4p{sup 6}) in Sr ii are evaluated. First-order, second-order, third-order, and all-order Coulomb energies and first-order and second-order Coulomb-Breit energies are calculated. Reduced matrix elements, oscillator strengths, transition rates, and lifetimes are determined for the levels up to n=7. Electric-dipole (5s{sub 1/2}-np{sub j}, n=5-26), electric-quadrupole (5s{sub 1/2}-nd{sub j}, n=4-26), and electric-octupole (5s{sub 1/2}-nf{sub j}, n=4-26) matrix elements are calculated to obtain the ground-state E1, E2, and E3 static polarizabilities. Scalar and tensor polarizabilities for the 5p{sub j}-9p{sub j} and 4d{sub j}-8d{sub j} excited states in Sr ii are also calculated. All the above-mentioned matrix elements are determined using the all-order method. We also investigate the hyperfine structure in {sup 87}Sr{sup +}. The hyperfine A values and B values are determined for the first low-lying levels up to n=7. The quadratic Stark effect on hyperfine-structure levels of the {sup 87}Sr{sup +} ground state is investigated. The calculated shift for the (F=5,M=0){r_reversible}(F=4,M=0) transition is found to be 0.120(1) Hz/(kV/cm){sup 2}. These calculations provide a theoretical benchmark for comparison with the experiment and theory. A careful study of uncertainty of our calculations is carried out for the transition-matrix elements, line strengths, transition rates, lifetimes, polarizabilities, and the Stark shift coefficient.

74 ATOMIC AND MOLECULAR PHYSICS↗

Level-resolved R-matrix calculations for the electron-impact excitation of Ne{sup 3+} and Ne{sup 6+}

Large-scale R-matrix calculations are carried out for the electron-impact excitation of Ne{sup 3+} and Ne{sup 6+}. For Ne{sup 3+}, a 581-LSJ-level R-matrix intermediate coupling frame transformation calculation is made for excitations up to the n=4 shell. For some transitions, large effective collision strength differences are found with current 23-jKJ-level Breit-Pauli R-matrix and earlier 22-LSJ-level R-matrix jj omega (JAJOM) calculations. For Ne{sup 6+}, a 171-jKJ-level Breit-Pauli R-matrix calculation is made for excitations up to the n=5 shell. For some transitions, large effective collision strength differences are found with current 46-jKJ-level Breit-Pauli R-matrix and earlier 46-LSJ-level R-matrix JAJOM calculations. Together with existing R-matrix calculations for other ion stages, high-quality excitation data are now available for astrophysical and laboratory plasma modeling along the entire Ne isonuclear sequence.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quasiparticle random-phase approximation calculations for M 1 transitions with the noniterative finite-amplitude method and application to neutron radiative capture cross sections

Here, we derive the equations of quasiparticle random-phase approximation (QRPA) based on the finite amplitude method with the Hartree-Fock+Bardeen–Cooper–Schrieffer (HF+BCS) single-particle states, and calculate the magnetic dipole (M⁢1) transition for deformed gadolinium isotopes. Our QRPA calculation shows both large spin-flip transitions in the 5 to 10 MeV excitation energy and the low energy orbital transition that would correspond to the M⁢1 scissors mode observed in nuclear experiments. Then, we calculate neutron capture reactions based on the statistical Hauser-Feshbach theory with the photoabsorption cross sections of even-even nuclei given by QRPA. We find that the capture cross section is enhanced due to the contribution from the low energy M⁢1 transition although the calculated capture cross section still underestimates the experimental data. This issue in the calculated capture cross section could be improved by uncertainties of the low energy E⁢1 transition neglected in our QRPA calculation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variational Monte Carlo calculations of n + H 3 scattering

A paramount goal in nuclear physics is to unify ab initio treatments of bound and unbound states. The position-space quantum Monte Carlo (QMC) methods have a long history of successful bound-state calculations in light systems but have seen minimal implementation in unbound systems. Here, we introduce a numerical method to improve the efficiency and accuracy of unbound-state calculations in QMC. As an initial application, we compute scattering observables for the smallest system available to probe three-body forces, the neutron-triton system, using variational Monte Carlo (VMC) wave functions. The method involves inferring long-range amplitudes in the wave function from integrals over the short-range region where all the particles interact. This approach using integral relations is well established in the literature; here, we develop it for the QMC framework. We validate our approach with a consistency check between short-range spectroscopic overlap functions computed from direct evaluation and from the integral relations; scattering amplitudes are long-range asymptotics of those overlaps. Comparison against published benchmark calculations using the same potential demonstrates that when applied to the current VMC wave functions, the integral method produces more accurate scattering observables than direct evaluation from the same variational wave function. However, it still differs noticeably from the exact results. Using additional interactions, we then present phase shifts and mixing parameters for the n + 3 H system. In particular, we present one of the first applications of the Norfolk family of local coordinate-space chiral potentials in unbound systems of A > 2. The Norfolk results accurately describe s-wave scattering but predict p-wave cross sections too large. Compared with previous QMC scattering calculations, the integral method avoids difficulties associated with the precise computation of energy differences and with convergence outside the interaction region, which is particularly severe in the variational calculation. Application of the integral method here paves the way for its use in Green's function Monte Carlo (GFMC) calculations. In GFMC, the wave functions are more accurate, but the high-precision convergence of their tails is slow, and there are additional difficulties in reading out amplitudes. Here, the integral methods will address both of those remaining problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of nuclear reaction cross sections on excited nuclei with the coupled-channels method

We calculate nuclear cross sections on excited nuclei in the fast neutron energy range. We partition the whole process into two contributions: the direct reaction part and the compound nuclear reactions. A coupled-channels method is used for calculating the direct transition of the nucleus from the initial excited state, which is a member of the ground-state rotational band, to the final ground and excited low-lying levels. This process is strongly affected by the channel coupling. The compound nuclear reactions on the excited state are calculated with the statistical Hauser-Feshbach model, with the transmission coefficients obtained from the coupled-channels calculation. The calculations are performed for a strongly deformed nucleus {sup 169}Tm, and selected cross sections for the ground and first excited states are compared. The calculation is also made for actinides to investigate possible modification to the fission cross section when the target is excited. It is shown that both the level coupling for the entrance channel, and the different target spin, change the fission cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exact and fast calculation of the X-ray pair distribution function

A fast and exact algorithm to calculate the powder pair distribution function (PDF) for the case of periodic structures is presented. The new algorithm calculates the PDF by a detour via reciprocal space. The calculated normalized total powder diffraction pattern is transferred into the PDF via the sine Fourier transform. The calculation of the PDF via the powder pattern avoids the conventional simplification of X-ray and electron atomic form factors. It is thus exact for these types of radiation, as is the conventional calculation for the case of neutron diffraction. The new algorithm further improves the calculation speed. Additional advantages are the improved detection of errors in the primary data, the handling of preferred orientation, the ease of treatment of magnetic scattering and a large improvement to accommodate more complex instrumental resolution functions.

36 MATERIALS SCIENCE↗

THERMAL SAFETY MARGIN CALCULATION OF THE MP-2 EXPERIMENT IN THE ADVANCED TEST REACTOR

The Mini-Plate 2 (MP-2) irradiation test is a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). The experiment is a drop-in test where small aluminum-clad fuel plate samples (mini plates) are cooled directly by the ATR Primary Coolant System (PCS) water. The MP-2 fuel plate experiment will be irradiated in several different irradiation locations of the ATR. This fueled experiment contains aluminum-clad fuel mini plates consisting of monolithic U-Mo. Four different types of fuel plates with fuel meat thickness and cladding are part of the MP-2 test. A thermal analysis has been performed on the MP-2 experiment. A method for calculating Departure from Nucleate Boiling Ratio (DNBR) and Flow Instability Ratio (FIR) during a reactivity transient using the commercial finite element and heat transfer code ABAQUS is discussed. At the start of an ATR cycle the heat generation rate of the fueled experiment is high and the heat rate multiplier from the outer shim control cylinders is low, while the reverse is true at the end of the ATR cycle. Thermal analyses at 10 day increments during the cycle calculate the DNBR and FIR during a reactivity transient. This technique calculates DNBR for the fuel plate surfaces and FIR for all water components for each finite element surface and node at various times during the ATR cycle. Heat rates vary with time during the transient calculation that are provided by a detailed physics analysis. Oxide growth on the fuel plates is also incorporated Results from the transient calculations are displayed with the ABAQUS post processor. By calculating these parameters at each location in the finite element model, conservatism is replaced with accuracy. This allows for a greater margin for the thermal hydraulic safety parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A procedure for calculation of monitor units for passively scattered proton radiotherapy beams

The purpose of this study is to validate a monitor unit (MU) calculation procedure for passively scattered proton therapy beams. The output dose per MU (d/MU) of a therapeutic radiation beam is traditionally calibrated under specific reference conditions. These conditions include beam energy, field size, suitable depth in water or water equivalent phantom in a low dose gradient region with known relative depth dose, and source to point of calibration distance. Treatment field settings usually differ from these reference conditions leading to a different d/MU that needs to be determined for delivering the prescribed dose. For passively scattered proton beams, the proton specific parameters, which need to be defined, are related to the energy, lateral scatterers, range modulating wheel, spread out Bragg peak (SOBP) width, thickness of any range shifter, the depth dose value relative to the normalization point in the SOBP, and scatter both from the range compensator and inhomogeneity in the patient. Following the custom for photons or electrons, a set of proton dosimetry factors, representing the changes in the d/MU relative to a reference condition, can be defined as the relative output factor (ROF), SOBP factor (SOBPF), range shifter factor (RSF), SOBP off-center factor (SOBPOCF), off-center ratio (OCR), inverse square factor (ISF), field size factor (FSF), and compensator and patient scatter factor (CPSF). The ROF, SOBPF, and RSF are the major contributors to the d/MU and were measured using an ion chamber in water tank during the clinical commissioning of each beam to create a dosimetry beam data table to be used for calculating the monitor units. The following simple formula is found to provide an independent method to determine the d/MU at the point of interest (POI) in the patient, namely, (d/MU)=ROF{center_dot}SOBPF{center_dot}RSF{center_dot}SOBPOCF{center_dot}OCR{center_dot}FSF{center_dot}ISF{center_dot}CPSF. The monitor units for delivering the intended dose (D) to the POI can be obtained from MU=D divide (d/MU). The accuracy and robustness of the above formula were validated by calculating the d/MU in water for many different combinations of beam parameters and comparing it with the corresponding measured d/MU by an ion chamber in a water or water/plastic phantom. This procedure has been in use for MU calculation for patient treatment fields at our facility since May 2006. The differences in the calculated and measured values of the d/MU for 623 distinct fields used for patient treatment during the period of May 2006 to February 2007 are within 2% for 99% of these fields. The authors conclude that an intuitive formula similar to the one used for monitor unit calculation of therapeutic photon beams can be used to compute the monitor units of passively scattered proton therapy beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

A correction-based dose calculation algorithm for kilovoltage x rays

Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. Imaging guidance procedures are necessary due to their potential benefits, but the additional incremental dose per treatment fraction may exceed an individual organ tolerance. Hence it is important to manage and account for this additional dose from imaging for radiotherapy patients. Currently available model-based dose calculation methods in radiation treatment planning (RTP) systems are not suitable for low-energy x rays, and new and fast calculation algorithms are needed for a RTP system for kilovoltage dose computations. This study presents a new dose calculation algorithm, referred to as the medium-dependent-correction (MDC) algorithm, for accurate patient dose calculation resulting from kilovoltage x rays. The accuracy of the new algorithm is validated against Monte Carlo calculations. The new algorithm overcomes the deficiency of existing density correction based algorithms in dose calculations for inhomogeneous media, especially for CT-based human volumetric images used in radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc

Purpose: The commercial release of volumetric modulated arc therapy techniques using a conventional linear accelerator and the growing number of helical tomotherapy users have triggered renewed interest in dose verification methods, and also in tools for exploring the impact of machine tolerance and patient motion on dose distributions without the need to approximate time-varying parameters such as gantry position, MLC leaf motion, or patient motion. To this end we have developed a Monte Carlo-based calculation method capable of simulating a wide variety of treatment techniques without the need to resort to discretization approximations. Methods: The ability to perform complete position-probability-sampled Monte Carlo dose calculations was implemented in the BEAMnrc/DOSXZYnrc user codes of EGSnrc. The method includes full accelerator head simulations of our tomotherapy and Elekta linacs, and a realistic representation of continous motion via the sampling of a time variable. The functionality of this algorithm was tested via comparisons with both measurements and treatment planning dose distributions for four types of treatment techniques: 3D conformal, step-shoot intensity modulated radiation therapy, helical tomotherapy, and volumetric modulated arc therapy. Results: For static fields, the absolute dose agreement between the EGSnrc Monte Carlo calculations and measurements is within 2%/1 mm. Absolute dose agreement between Monte Carlo calculations and treatment planning system for the four different treatment techniques is within 3%/3 mm. Discrepancies with the tomotherapy TPS on the order of 10%/5 mm were observed for the extreme example of a small target located 15 cm off-axis and planned with a low modulation factor. The increase in simulation time associated with using position-probability sampling, as opposed to the discretization approach, was less than 2% in most cases. Conclusions: A single Monte Carlo simulation method can be used to calculate patient dose distribution for various types of treatment techniques delivered with either tomotherapy or a conventional linac. The method simplifies the simulation process, improves dose calculation accuracy, and involves an acceptably small change in computation time.

60 APPLIED LIFE SCIENCES↗

Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a synchrotron radiotherapy technique that explores the limits of the dose-volume effect. Preclinical studies have shown that MRT irradiations (arrays of 25-75-{mu}m-wide microbeams spaced by 200-400 {mu}m) are able to eradicate highly aggressive animal tumor models while healthy tissue is preserved. These promising results have provided the basis for the forthcoming clinical trials at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). The first step includes irradiation of pets (cats and dogs) as a milestone before treatment of human patients. Within this context, accurate dose calculations are required. The distinct features of both beam generation and irradiation geometry in MRT with respect to conventional techniques require the development of a specific MRT treatment planning system (TPS). In particular, a Monte Carlo (MC)-based calculation engine for the MRT TPS has been developed in this work. Experimental verification in heterogeneous phantoms and optimization of the computation time have also been performed. Methods: The penelope/penEasy MC code was used to compute dose distributions from a realistic beam source model. Experimental verification was carried out by means of radiochromic films placed within heterogeneous slab-phantoms. Once validation was completed, dose computations in a virtual model of a patient, reconstructed from computed tomography (CT) images, were performed. To this end, decoupling of the CT image voxel grid (a few cubic millimeter volume) to the dose bin grid, which has micrometer dimensions in the transversal direction of the microbeams, was performed. Optimization of the simulation parameters, the use of variance-reduction (VR) techniques, and other methods, such as the parallelization of the simulations, were applied in order to speed up the dose computation. Results: Good agreement between MC simulations and experimental results was achieved, even at the interfaces between two different media. Optimization of the simulation parameters and the use of VR techniques saved a significant amount of computation time. Finally, parallelization of the simulations improved even further the calculation time, which reached 1 day for a typical irradiation case envisaged in the forthcoming clinical trials in MRT. An example of MRT treatment in a dog's head is presented, showing the performance of the calculation engine. Conclusions: The development of the first MC-based calculation engine for the future TPS devoted to MRT has been accomplished. This will constitute an essential tool for the future clinical trials on pets at the ESRF. The MC engine is able to calculate dose distributions in micrometer-sized bins in complex voxelized CT structures in a reasonable amount of time. Minimization of the computation time by using several approaches has led to timings that are adequate for pet radiotherapy at synchrotron facilities. The next step will consist in its integration into a user-friendly graphical front-end.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose calculation for electron therapy using an improved LBR method

Purpose: To calculate the percentage depth dose (PDD) of any irregularly shaped electron beam using a modified lateral build-up ratio (LBR) method.Methods: Percentage depth dose curves were measured using 6, 9, 12, and 15 MeV electron beam energies for applicator cone sizes of 6 Multiplication-Sign 6, 10 Multiplication-Sign 10, 14 Multiplication-Sign 14, and 20 Multiplication-Sign 20 cm{sup 2}. Circular cutouts for each cone were prepared from 2.0 cm diameter to the maximum possible size for each cone. In addition, three irregular cutouts were prepared.Results: The LBR for each circular cutout was calculated from the measured PDD curve using the open field of the 14 Multiplication-Sign 14 cm{sup 2} cone as the reference field. Using the LBR values and the radius of the circular cutouts, the corresponding lateral spread parameter [{sigma}{sub R}(z)] of the electron shower was calculated. Unlike the commonly accepted assumption that {sigma}{sub R}(z) is independent of cutout size, it is shown that its value increases linearly with circular cutout size (R). Using this characteristic of the lateral spread parameter, the PDD curves of irregularly shaped cutouts were calculated. Finally, the calculated PDD curves were compared with measured PDD curves.Conclusions: In this research, it is shown that the lateral spread parameter {sigma}{sub R}(z) increases with cutout size. For radii of circular cutout sizes up to the equilibrium range of the electron beam, the increase of {sigma}{sub R}(z) with the cutout size is linear. The percentage difference of the calculated PDD curve from the measured PDD data for irregularly shaped cutouts was under 1.0% in the region between the surface and therapeutic range of the electron beam. Similar results were obtained for four electron beam energies (6, 9, 12, and 15 MeV)

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret{sub eq} for scan modes involving table translation and the midpoint dose D{sub L}(0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret{sub eq} was calculated from CTDI{sub 100} and ε(CTDI{sub 100}) (CTDI{sub 100} efficiency), and D{sub L}(0) was calculated from D-caret{sub eq} and the approach to equilibrium function H(L) =D{sub L}(0)/D{sub eq}, where D{sub eq} was the equilibrium dose. CTDI{sub 100} may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI{sub Vol} using the central to peripheral CTDI{sub 100} ratio (R{sub 100}). The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R{sub 100} was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D{sub L}(0) and D{sub L}(0)/D{sub eq} in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret{sub eq} and D{sub L}(0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers. R{sub 100} is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D{sub eq} ratio is about 1.50 and 1.12 times of R{sub 100} for the 32- and 16-cm diameter PMMA phantom, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗