Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLADDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Next-Generation Tumbleweed Rover

A document describes a next-generation tumbleweed rover that involves a split balloon system that is made up of two half-spherical air bladders with a disc between them. This disc contains all the electronics and instruments. By deflating only the bottom balloon, the rover can sit, bringing the surface probe into contact with the ground. The bottom balloon has a channel passing through it, allowing the surface probe to reach the surface through the balloon. Once the sample has been gathered and analyzed, the rover can re-inflate the lower air bladder and continue rolling. The rover will use a small set of instruments and electronics situated at the center of its inflatable spherical hull. The current version is a large beach-ball-like construction, about 1.8 m in diameter and weighing roughly 15 kg. The rover comprises two major parts, an outer spherical hull (split in half at the central disc) and an inner, disc-shaped cylindrical section. The balloons are attached to the bottom and top of the disc. Inside the disc, there are temperature and pressure sensors to keep track of the inner and outer conditions of the rover. A system of pumps and valves is responsible for independently inflating and deflating the balloons as necessary. There are also accelerometers to record the movement, together with a GPS receiver. The data are then sent through a modem to a control station. This work builds upon the project Tumbleweed rover for planetary exploration, described in the Technical Support Package.

Nosanov, Jeffrey P.↗

Continued Water-Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full‐scale, Orion sized water‐based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research and experimentation to the full scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Design and construction of these HX's led to successful testing of both PCM HX's.

Hansen, Scott↗

Locomotion of Amorphous Surface Robots

An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

Bradley, Arthur T.↗

Continued Water-Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to meet the full heat rejection demands. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HX's do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full-scale, Orion sized water-based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research on freeze front propagation to a full-scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Two units, Units A and B, were constructed and differed only in their midplate design. Both units failed multiple times during testing. This report highlights learning outcomes from these tests and are applied to a final sub-scale PCM HX which is slated to be tested on the ISS in early 2017.

Hansen, Scott W.↗

Locomotion of Amorphous Surface Robots

An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

Bradley, Arthur T.↗

Development Requirements for Spacesuit Elbow Joint

Functional Requirements for spacesuit elbow joint:1) The system is a conformal, single-axis spacesuit pressurized joint that encloses the elbow joint of the suited user and uses a defined interface to connect to the suit systems on either side of the joint.2) The system shall be designed to bear the loads incurred from the internal pressure of the system, as well as the expected loads induced by the user while enabling the user move the joint through the required range of motion. The joint torque of the system experienced by the user shall remain at or below the required specification for the entire range of motion.3) The design shall be constructed, at a minimum, as a two-layer system. The internal, air-tight layer shall be referred to as the bladder, and the layer on the unpressurized side of the bladder shall be referred to as the restraint. The design of the system may include additional features or layers, such as axial webbing, to meet the overall requirements of the design.

Peters, Benjamin↗

Locomotion of Amorphous Surface Robots

An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

Bradley, Arthur T.↗

Inflatable Softgoods Testing Capability Development for Habitation

The Habitation Systems Development Office (HP40) at NASA Marshall Space Flight Center supports systems engineering, integration, and project management for next generation space habitats. The office is responsible for formulation activities for Lunar Surface Habitat and Mars Transit Habitat. HP40 also manages commercial partnerships for exploration habitat development. The Lunar Surface Habitat is intended to initially support a minimum of two crew on the lunar surface for an approximately 30-day mission, with the ability to accommodate four crew for short durations. The Mars Transit Habitat will transport four crew to and from Mars orbit on a potentially 1,200 day mission. Both concepts are envisioned to leverage inflatable softgoods as the primary structural material for the habitation portion of the architecture. Inflatable softgoods are a complex, multi-material system consisting of multiple layers which perform specific functions. A bladder layer (polymer) contains the habitat’s atmosphere. The bladder is indexed to a woven restraint layer, usually Kevlar or Vectran, which serves as the structural layer. The remaining outer layers are for micro-meteoroid orbital debris (MMOD) shielding, protection from atomic Oxygen (if the material system is to be deployed in low earth orbit), and thermal insulation. The primary advantage of inflatable softgoods is that they can offer a larger volume per unit mass relative to a rigid metal structure. Inflatable softgoods have a strong development heritage within NASA, beginning with work in the 1960s in partnership with Goodyear Aerospace and continuing with Johnson Space Center’s TransHab project in the 1990s . Some development efforts subsequently transitioned into the private sector to mature the material technology for flight applications, including human habitation. In August 2022, NASA published its guidelines for certification of crewed inflatable softgoods structures (JSC-67721). This document outlines a series of tests which will be needed to certify inflatable softgoods material systems for use in crewed mission applications. It includes burst testing at the subscale and full-scale to determine the ultimate burst pressure of the softgoods architecture. Creep (long term deformation of the material under stress) is a key failure mode which must be characterized. Creep testing at the component and module levels is also recommended to generate time to failure curves and verify that the inflatable system has a predicted operational life which exceeds mission parameters. ET (Test Engineering) at MSFC and HP40 have worked together to establish softgoods testing capabilities for the center. This includes the ability to conduct module level burst tests and creep tests. The poster will highlight these capabilities and provide examples of testing which has been performed to date by ET. NASA MSFC anticipates that these test capabilities will continue to offer critical support for companies pursuing inflatable softgoods for exploration applications (lunar surface habitation, Mars transit) as well as commercial low earth orbit platforms.

habitation↗

Prosthesis Socket Pressure Tools v. 1.0

Renders, saves, and analyzes pressure from several sensors in a prosthesis™ socket. The program receives pressure data from 64 manometers and parses the pressure for each individual sensor. The program can then display those pressures as number in a table. The program also interpolates pressures between manometers to create a larger set of data. This larger set of data is displayed as a simple contour plot. That same contour plot can also be placed on a three-dimensional surface in the shape of a prosthesis.This program allows for easy identification of high pressure areas in a prosthesis to reduce the user™s discomfort. The program parses the sensor pressures into a human-readable numeric format. The data may also be used to actively adjust bladders within the prosthesis to spread out pressure in real time, according to changing demands placed on the prosthesis. Interpolation of the pressures to create a larger data set makes it even easier for a human to identify particular areas of the prosthesis that are under high pressure. After identifying pressure points, a prosthetician can then redesign the prosthesis and/or command the bladders in the prosthesis to attempt to maintain constant pressures.

Janik, Gregory↗

Hybrid compressed air/water energy storage system and method

A hybrid compressed air/water energy storage system is described. The system includes a series of water containers and a plurality of inflatable bladders held within each container. An air compression facility is used to inflate the bladders upon which water is forced out of the containers to a water storage facility at a higher potential energy. The system includes a water powered turbine and an expansion turbine. Thus, the system can produce power from both the water powered turbine (e.g., as a component of a hydroelectric plant) and from the expansion turbine (e.g., as a component of a CAES plant). The system can be utilized in a subsurface land-based system or a submerged water-based system.

13 HYDRO ENERGY↗

Remediation of Uranium Impacted Sediments in a Watercourse - 12486

In 2009, remediation was initiated for a non-operational fuel cycle facility previously used for government contract work. Between 2009 and the spring of 2011, remediation efforts were focused on demolition of contaminated buildings and removal of contaminated soil. In the late spring of 2011, the last phase of remediation commenced involving the removal of contaminated sediments from portions of a 1,200 meter long gaining stream. Planning and preparation for remediation of the stream began in 2009 with submittal of permit applications to undertake construction activities in a wetland area. The permitting process was lengthy and involved securing permits from multiple agencies. However, early and frequent communication with stakeholders played an integral role in efficiently obtaining the permit approvals. Frequent communication with stakeholders throughout the planning and remediation process also proved to be a key factor in timely completion of the project. The remediation of the stream involved the use of temporary bladder berms to divert surface water flow, water diversion piping, a sediment vacuum removal system, excavation of sediments using small front-end loaders, sediment dewatering, and waste packaging, transportation and disposal. Many safeguards were employed to protect several species of concern in the work area, water management during project activities, challenges encountered during the project, methods of Final Status Survey, and stream restoration. The planning and permitting effort for the Site Brook remediation began in May 2009 and permits were approved and in place by February 2011. The remediation and restoration of the Site Brook began in April 2011 and was completed in November 2011. The remediation of the Site Brook involved the use of temporary bladder berms to divert surface water flow, water diversion piping, a sediment vacuum removal system, excavation of sediments using small front-end loaders, sediment dewatering, and waste packaging, transportation, disposal, FSS, and restoration. Early and frequent communications with stakeholders proved to be a key factor in timely completion of the project. Challenges encountered during the remediation effort were overcome by proper planning and having preparedness procedures in place prior to executing the work. With the remediation and restoration successfully completed, the only remaining task is to monitor/maintain the restoration for 10 years. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Morphology and composition of Goldeye (Hiodontidae; Hiodon alosoides) otoliths

In this work, we provide up-todate morphological and compositional data on otoliths of the osteoglossomorph Goldeye (Hiodon alosoides). Using computed tomography (CT) X-ray, we documented the location of each of the three pairs of otoliths (lapilli, sagittae, and asterisci) in relation to the swim bladder, which extended forward in close proximity to the sagittae and asterisci. The lappili were the largest otoliths in terms of surface area and volume, but the sagittae were highly modified, appearing spiral in shape when viewed dorsally, with a surface area to volume ratio more than double that of the lapilli. Using scanning electron microscopy, the surface of each otolith was viewable in great detail, and small otoconia (~10.5 μm diameter) were observed on each, but were most numerous on the sagittae. Additionally, on scanning electron micrographs, the sagittae appeared to be bi-lobed, with asymmetrical lobes each oriented in the same general direction. Using neutron and X-ray diffraction methods, we found three polymorphs of calcium carbonate crystals (aragonite, vaterite, and calcite), sometimes all within the same otolith. However, in general, lapilli and sagittae were composed predominately of aragonite whereas asterisci were composed chiefly of vaterite. With these results, we provide information on a unique species, whose inclusion in future studies would benefit our understanding of fish hearing, fish evolution, and fisheries ecology.

59 BASIC BIOLOGICAL SCIENCES↗

Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary diversions: a primer of the surgical techniques and imaging findings

Objective: The article attempts to describe the indications, classification, and surgical anatomy of the commonly performed urinary diversion procedures, followed by the imaging protocol and radiological appearances of the normal postoperative anatomy and complications related to these procedures. Contents: Diversion procedures are used to reroute urine after cystectomy and in patients with refractory neurogenic or outlet obstruction of the urinary bladder. Broadly, these can be classified as continent and incontinent diversions. Patients with urinary diversions frequently undergo radiological investigations for the detection of complications. Commonly, a loopogram or pouchogram is performed few weeks after the surgery to look for leak, whereas CT or MRI is used for long-term follow-up. Postoperative complications can be early (within 30 days of the surgery) or delayed and include leaks, collections, strictures, calculi, parastomal hernia, small bowel obstruction, and oncologic recurrence. Conclusion: A variety of urinary diversion procedures are commonly performed and interpretation of the postsurgical anatomy can be overwhelming for the general radiologist. This article provides a basic understanding of the normal anatomy as well as a thorough discussion on the imaging protocol and radiological appearances of the potential complications associated with these procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Safe is Bilateral Internal Iliac Artery Embolization Prior to EVAR?

Purpose. To assess the outcomes of patients after bilateral internal iliac artery (IIA) embolization prior to endovascular aneurysm repair (EVAR). Methods. Thirty-nine patients (age range 55-88 years, mean 72.5 years; 2 women) underwent IIA embolization/occlusion before EVAR. There were 28 patients with aorto-biiliac aneurysms and 6 with bilateral common iliac artery (CIA) aneurysms. Five patients with unilateral CIA aneurysms had previous surgical ligation of the contralateral IIA or inadvertent covering by the stent-graft of the contralateral IIA origin. Outcomes were assessed by clinical follow-up. Results. Severe ischemic complications were limited to spinal cord ischemia in 1 patient (3%) who developed paraparesis following EVAR. No other severe ischemic complications such as buttock necrosis, or bowel or bladder ischemia, occurred. Buttock and/or thigh claudication occurred in 12 patients (31%) and persisted beyond 1 year in 3 patients (9%). Sexual dysfunction occurred in 2 patients (5%). Patients who underwent simultaneous embolization had a 25% (3/12) ischemic complication rate versus 41% (11/27) in those with sequential embolization (p = 0.48). Embolization limited to the main trunk of the IIA resulted in a significantly reduced ischemic complication rate of 16% (3/19) versus 55% (11/20) of patients who had a more distal embolization of the IIA (p = 0.019, Fisher's exact test). Conclusion. Severe complications after bilateral IIA embolization are uncommon. Although buttock/thigh claudication occurs in around 30% of patients soon after the procedure, this resolves in the majority after 1 year. There is no obvious benefit for sequential versus simultaneous IIA embolization in our series. Occlusion of the proximal IIA trunk is associated with reduced complications compared with occlusion of the distal IIA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Preoperative Superselective Embolization of the Isthmus in a Patient with Upper Urinary Tract Urothelial Carcinoma and Horseshoe Kidney

Standard treatment for upper urinary tract urothelial carcinoma (UUTUC) implies the radical removal of all urothelium-lined tissue, which requires nephroureterectomy with bladder cuff removal. We report on a patient with a rare coincidence of UUTUC and horseshoe kidney in whom a preoperative angiography helped to identify and subsequently embolize an abberant isthmic feeding artery, which was located in between both collecting systems. Ischemic discoloration of the isthmus area facilitated resection and no major blood loss occurred. Preoperative superselective embolization of the isthmus as the renal split area can be an effective tool to facilitate nephroureterectomy in the case of a horseshoe kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intramural Dissection of the Renal Collecting System During Percutaneous Nephrostomy: Computed Tomography Findings of a Rare Complication

Intramural dissection of the renal collecting system during percutaneous nephrostomy (PCN) is a rare complication that can be challenging to diagnose. In this report, we describe the computed tomography (CT) and fluoroscopic findings of urothelial dissection during CT-guided PCN in a 65-year old patient with an obstructed congenital solitary left kidney due to an urinary bladder carcinoma. To our knowledge, CT findings of urothelial dissection have not yet been described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical, Laboratorial, and Urodynamic Findings of Prostatic Artery Embolization for the Treatment of Urinary Retention Related to Benign Prostatic Hyperplasia. A Prospective Single-Center Pilot Study

PurposeThis study was designed to describe the clinical, laboratorial, and urodynamic findings of prostatic artery embolization (PAE) in patients with urinary retention due to benign prostatic hyperplasia (BPH).MethodsA prospective study of 11 patients with urinary retention due to BPH was conducted. Patients underwent physical examination, prostate specific antigen (PSA) measurement, transrectal ultrasound, and magnetic resonance imaging. International prostate symptom score (IPSS), quality of life (QoL), and urodynamic testing were used to assess the outcome before and after 1 year.ResultsClinical success was 91 % (10/11 patients) with a mean follow-up of 22.3 months (range, 12-41 months). At the first year follow-up, the mean IPSS score was 2.8 points (p = 0.04), mean QoL was 0.4 points (p = 0.001), mean PSA decreased from 10.1 to 4.3 ng/mL (p = 0.003), maximum urinary flow (Qmax) improved from 4.2 to 10.8 mL/sec (p = 0.009), and detrusor pressure (Pdet) decreased from 85.7 to 51.5 cm H{sub 2}O (p = 0.007). Before PAE, Bladder Outlet Obstruction Index (BOOI) showed values >40 in 100 % of patients. After PAE, 30 % of patients were >40 (obstructed), 40 % were between 20 and 40 (undetermined), and 30 % were <20 (unobstructed). Patients with a BOOI <20 had higher PSA values at 1-day after PAE.ConclusionsClinical and urodynamic parameters improved significantly after PAE in patients with acute urinary retention due to BPH. Total PSA at day 1 after PAE was higher in patients with unobstructed values in pressure flow studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗