Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BASE PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

Effects of external stream flow and afterbody variations on the performance of a plug nozzle

The off-design operation of an isentropic plug nozzle designed for a jet pressure ratio of 15 was investigated experimentally at subsonic Mach numbers up to 0.9 and jet pressure ratios up to 5. When installed in a cylindrical nacelle with a sharp turn at the nozzle lip, the interaction of the jet and the external stream produced low pressures on the base formed by the high lip angle. These low pressures increased the nacelle drag and caused an overexpansion of the jet, which resulted in lower pressures on the plug and, hence, reduced thrust. With a boattail ahead of the plug nozzle, the base pressures were increased and the jet overexpansion significantly reduced.

Salmi, R J↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Note: A portable, light-emitting diode-based ruby fluorescence spectrometer for high-pressure calibration

Ruby (Al{sub 2}O{sub 3}, with {approx}0.5 wt. % Cr doping) is one of the most widely used manometers at the giga-Pascal scale. Traditionally, its fluorescence is excited with intense laser sources. Here, I present a simple, robust, and portable design that employs light-emitting diodes (LEDs) instead. This LED-based system is safer in comparison with laser-based ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile semi-batch apparatus for manometric measurement of gas–solid reaction rates

In this study, we describe the design, construction, operation, and performance of a simple and versatile semi-batch reactor that is especially useful for measurement of gas/solid reaction rates at pressures in the range of 1 mTorr to 1500 Torr. The reactor operates by repeatedly imposing small AC modulations of reactant gas pressure on top of a much larger DC pressure background. Based on the rate of pressure relaxation following each AC pulse, the reaction rate is determined. Our design is characterized by modular construction from off-the-shelf, ultra-high-vacuum-compatible components, which facilitate easy retrofitting and adaptation to a range of experimental conditions. Automated experiment control and data acquisition is accomplished via a custom National Instruments © LabView virtual instrument. Data analysis is automated using a custom series of Mathworks © Matlab scripts. We demonstrate reactor performance through measurements of hydrogenation kinetics for a composite H 2 getter material consisting of 1,4-bis(phenylethynyl)benzene mixed with a palladium/carbon catalyst.

47 OTHER INSTRUMENTATION↗

Magnetic Fluid Friction and Wear Behavior

The friction and wear properties of two groups of magnetic fluids, one developed at NASA Lewis Research Center and a commercial fluid, were evaluated for boundary lubrication. Friction and wear measurements were made using a pin-on-disk apparatus. Three different ball materials were evaluated, (1) 440C, (2) Al2O3, and (3) Si3N4 against 440C disks. The first class of magnetic fluids have a low vapor pressure hydrocarbon base oil and are suitable for space application. Four variations of this fluid were evaluated: (1) the base oil, (2) base oil with anti-wear additives, (3) a 100 Gauss strength magnetic fluid, and (4) a 400 gauss magnetic fluid. The commercial fluid base oil and four different magnetic particle concentration levels have been evaluated. A space qualified fluorinated lubricant was tested for base line comparison. Hardness, optical microscopy, surface profilometry, and surface analysis were used to characterize the test specimens. Friction was unaffected by the concentration of magnetic particles. Wear rates for magnetic fluids were slightly higher than the base oil. The low vapor pressure magnetic fluid has better wear characteristics than the space qualified fluorinated lubricant.

Keith, Theo G., Jr.↗

Benchmark Comparisons of Lattice Physics Calculations for Thorium-Based Fuels in Pressure-Tube Heavy Water Reactors

Thorium is a fertile nuclear fuel resource that is nearly three times as abundant as uranium in the earth's crust and that can be exploited and used to extend uranium resources. The pressure tube heavy water reactor (PTHWR) is an excellent existing technology for utilizing thorium-based fuels, due to its high neutron economy achieved by using heavy water as a moderator and coolant, the ability to perform online refueling, and its flexibility in fuel management. Reactor physics studies are underway at the Canadian Nuclear Laboratories (CNL) to evaluate several types of thorium-based fuels that could be implemented in PT-HWRs in the near-term and intermediate future, building upon past experience. For preliminary, conceptual studies, deterministic lattice physics and core physics codes such as WIMS-AECL and RFSP are used to provide quick and more approximate estimates of performance and safety characteristics. The objective of this study was to perform 2D lattice physics benchmark comparisons between WIMS-AECL and MCNP5 for several types of thorium-based fuel bundle lattices for potential use in PT-HWRs. Benchmark comparisons will help confirm the validity of deterministic calculation results, and provide estimates of the potential magnitude of calculation errors and uncertainties. Areas for potential improvements in the WIMS-AECL calculations may also be identified. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real time measurement of shock pressure

A fiber-based optical pressure-sensor, made using semiconductor nanocrystal quantum dots (NQDs) as the active transducing material, provides response time fast enough for shock wave measurements. For NQDs, the shift in band gap as a result of applied pressure can be observed as a shift of the photoluminescence (PL) peak. Further, the shift of the principal absorbance feature allows pressure measurements faster than those obtainable by following the PL peak.

Sander, Robert K.↗

Characterization of pore structure in cement-based materials using pressurization-depressurization cycling mercury intrusion porosimetry (PDC-MIP)

Numerous mercury intrusion porosimetry (MIP) studies have been carried out to investigate the pore structure in cement-based materials. However, the standard MIP often results in an underestimation of large pores and an overestimation of small pores because of its intrinsic limitation. In this paper, an innovative MIP method is developed in order to provide a more accurate estimation of pore size distribution. The new MIP measurements are conducted following a unique mercury intrusion procedure, in which the applied pressure is increased from the minimum to the maximum by repeating pressurization-depressurization cycles instead of a continuous pressurization followed by a continuous depressurization. Accordingly, this method is called pressurization-depressurization cycling MIP (PDC-MIP). By following the PDC-MIP testing sequence, the volumes of the throat pores and the corresponding ink-bottle pores can be determined at every pore size. These values are used to calculate pore size distribution by using the newly developed analysis method. This paper presents an application of PDC-MIP on the investigation of the pore size distribution in cement-based materials. The experimental results of PDC-MIP are compared with those measured by standard MIP. The PDC-MIP is further validated with the other experimental methods and numerical tool, including nitrogen sorption, backscanning electron (BSE) image analysis, Wood's metal intrusion porosimetry (WMIP) and the numerical simulation by the cement hydration model HYMOSTRUC3D.

36 MATERIALS SCIENCE↗

Simple Fabry-Perot based Instrument for Surface Pressure Sensing from Space

Mitchel and O'Brien observed in 1989 that a passive satellite measurement using the oxygen A band could exhibit a precision of better than 1% when used to make a surface pressure measurement. I will present a design and performance simulation for a Fabry-Perot interferometer based instrument which should exceed this level of performance. The design is small, inexpensive, and rugged. Preliminary results from a laboratory prototype of the instrument will be presented.

Heaps, William S.↗

High-pressure sensor using piezoelectric bending resonators

A novel design of pressure sensor based on piezoelectric bending resonator is described in this paper. The resonator is isolated from and mechanically coupled to the surrounding fluid using a sealed enclosure. The pressure applied to the enclosure induces a compressive stress to the resonator and reduces its resonance frequency. In principle the mechanism allows for achieving large resonance frequency shifts close to 100% of the resonance frequency. A high-pressure sensor based on the mechanism was designed for down-hole pressure monitoring in oil wells. The sensor is potentially remotely-readable via the transmission of an electromagnetic signal down a waveguide formed by the pipes in the oil well. The details of the pressure sensor design and verification by FE analysis and initial test results of a preliminary prototype are presented in this paper.

Takano, Nobuyuki↗

Graphene-elastomer nanocomposites based flexible piezoresistive sensors for strain and pressure detection

Highlights: • Fabricating flexible piezoresistive sensors based on PDMS/GNPs nanocomposites. • Positive strain sensitive capacity occurs during increasing pressure-loading process but before the threshold of forces loading. • Tunable strain and pressure sensitivity are achieved by controlling GNPs incorporation, and improved to 140 and 260 at 5 wt% GNPs respectively. • Superior dynamic correspondence with applied pressure and relatively high repeatability. • Application of the GNPs/PDMS piezoresistive sensors as detecting the finger motions. - Abstract: Strain and pressure sensitive flexible piezoresistive sensors have been fabricated based on nanocomposites of graphene nanoplatelets (GNPs) and Polydimethylsiloxane (PDMS) elastomer. The strain detective sensors show positive piezoresistive characteristic under diverse levels of static strain up to 20% due to the flexibility and stretchability of PDMS elastomer. Tunable strain sensitivity of GNPs/PDMS piezoresistive sensors can be achieved by controlling GNPs incorporation into PDMS elastomer, which will be improved to 140 at 5 wt% GNPs concentration. In addition, pressure sensitive response, which exists when the pressure loading is less than threshold pressure, also can be observed in GNPs/PDMS piezoresistive sensors. The GNPs network-elastomer nanocomposite based pressure sensors show tunable piezoresistivity in the ranges of ∼260 under increasingly higher GNPs concentrations. During the cyclic pressure loading, the pressure sensitive behavior of GNPs/PDMS nanocomposites manifests a superior dynamic correspondence with applied pressure while the resistance response can retain at a relatively high level under multiple loading-unloading cycles. Since the GNPs/PDMS piezoresistive sensors can not only respond to subtle bending but also distinguish them accurately for detecting the finger motions, it will make the GNPs/PDMS nanocomposite a good candidate for artificial skin and wearable sensor applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Flow Control and Measurement in Electric Propulsion Systems: Towards an AIAA Reference Standard

Accurate control and measurement of propellant flow to a thruster is one of the most basic and fundamental requirements for operation of electric propulsion systems, whether they be in the laboratory or on flight spacecraft. Hence, it is important for the electric propulsion community to have a common understanding of typical methods for flow control and measurement. This paper addresses the topic of propellant flow primarily for the gaseous propellant systems which have dominated laboratory research and flight application over the last few decades, although other types of systems are also briefly discussed. While most flight systems have employed a type of pressure-fed flow restrictor for flow control, both thermal-based and pressure-based mass flow controllers are routinely used in laboratories. Fundamentals and theory of operation of these types of controllers are presented, along with sources of uncertainty associated with their use. Methods of calibration and recommendations for calibration processes are presented. Finally, details of uncertainty calculations are presented for some common calibration methods and for the linear fits to calibration data that are commonly used.

thrust measurement↗

Pressure-induced anomalous valence crossover in cubic YbCu5-based compounds

A pressure-induced anomalous valence crossover without structural phase transition is observed in archetypal cubic YbCu5 based heavy Fermion systems. The Yb valence is found to decrease with increasing pressure, indicating a pressure-induced crossover from a localized 4f13 state to the valence fluctuation regime, which is not expected for Yb systems with conventional c–f hybridization. This result further highlights the remarkable singularity of the valence behavior in compressed YbCu5- based compounds. The intermetallics Yb2Pd2Sn, which shows two quantum critical points (QCP) under pressure and has been proposed as a potential candidate for a reentrant Yb2+ state at high pressure, was also studied for comparison. In this compound, the Yb valence monotonically increases with pressure, disproving a scenario of a reentrant non-magnetic Yb2+ state at the second QCP.

36 MATERIALS SCIENCE↗

Microstructure-based modeling of inner oxygen pressure in solid oxide electrolysis cells: Analysis of electrode delamination and mitigation

One major degradation mechanism during long-term operation of solid oxide electrolysis cells (SOECs) is delamination of oxygen electrodes (OEs). The driving force for the electrode delamination could be the generated high inner oxygen pressure near the electrode-electrolyte interface during operation. However, the effects of transport properties and electrode thickness on the inner oxygen partial pressure are not well understood. Here a microstructure-based electrochemical model, which includes the conduction of electrons and oxygen ions coupled with Butler-Volmer-type chemical reactions at triple-phase-boundaries (TPBs), is employed to investigate the oxygen pressure in lanthanum strontium manganate (LSM)-based SOECs. The model is applied to both two-dimensional (2D) prototype microstructures and three-dimensional (3D) realistic microstructures, and the oxygen pressure is analyzed as a function of transport properties and electrode thickness under both potentiostatic and galvanostatic operations. The simulation results suggest strategies to suppress electrode delamination. The simulation results are compared to an analytical solution, and the discrepancies are attributed to the Butler-Volmer-type kinetics included in the microstructure-based model.

25 ENERGY STORAGE↗

Linking pore-scale interfacial curvature to column-scale capillary pressure

Synchrotron-based tomographic datasets of oil-water drainage and imbibition cycles have been analyzed to quantify phase saturations and interfacial curvature as well as connected and disconnected fluid configurations. This allows for close observation of the drainage and imbibition processes, assessment of equilibrium states, and studying the effects of fluid phase disconnection and reconnection on the resulting capillary pressures and interfacial curvatures. Based on this analysis estimates of capillary pressure calculated from interfacial curvature can be compared to capillary pressure measured externally with a transducer. Results show good agreement between curvature-based and transducer-based measurements when connected phase interfaces are considered. Curvature measurements show a strong dependence on whether an interface is formed by connected or disconnected fluid and the time allowed for equilibration. The favorable agreement between curvature-based and transducer-based capillary pressure measurements shows promise for the use of image-based estimates of capillary pressure for interfaces that cannot be probed with external transducers as well as opportunities for a detailed assessment of interfacial curvature during drainage and imbibition.

02 PETROLEUM↗