Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

West Valley Demonstration Project Annual Site Environmental Report (ASER) for Calendar Year 2015

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2015. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2015. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2015 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source [Slides]

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of io n source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

EMP Attachment 3 Dose Assessment Guidance

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for individual receptor and collective dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL Richland Campus and Marine Sciences Laboratory (Sequim, Washington). The application of Richland Campus ambient external dose results is also briefly discussed. The methods used to perform the biota dose assessment reported in the Site Environmental Report are discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

EMP, Attachment 3: Dose Assessment Guidance

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for dose to an individual member of the public receptor, collective dose, and biota dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL Richland Campus and PNNL Sequim Campus. Dose determinations from Richland Campus surveillance of ambient external dose and ambient air particulates is also briefly discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

Comparison of VIIRS Prelaunch RVS Among Independent Studies

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the NPOESS (National Polar-orbiting Operational Environmental Satellite System), upgraded and developed recently from heritage instruments including AVHRR, OLS, MODIS, and SeaWiFS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and will be used on-orbit to characterize the response for the all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed and their results were compared and validated. This document provides RVS results from three groups: the NPP Instrument Calibration Support Team (NICST), Raytheon, and the Aerospace Corporation. A comparison of the RVS results obtained using a 2nd order polynomial fit to measurement data is conducted for each band, detector, and half angle mirror (HAM) side. The associated RVS fitting residuals are examined and compared with the relative differences in RVS found between independent studies. Results show that the agreement is within 0.1% and comparable with fitting residuals for all bands except for RSB band M9, where a difference of 0.2% results from the application of the atmospheric water vapor correction for laboratory conditions during the test by Raytheon. NICST has slightly larger RSB RVS uncertainties but still well within the 0.3% total uncertainty allowed for the RVS characterization defined in the Performance Verification Plan.

Wu, Aisheng↗

Assessment of the NPP VIIRS RVS for the Thermal Emissive Bands Using the First Pitch Maneuver Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) (launched in October 2011). VIIRS sensor design draws on heritage instruments including AVHRR, OLS, SeaWiFS and MODIS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first three months of intensive Cal/Val. The NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of scan angles, which can be used to characterize the TEB RVS. This study will provide our analysis of the pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab tests will be conducted for each band, detector, and half angle mirror (HAM) side

Wu, A.↗

Determination of the NOAA-20 VIIRS TEB RVS from Emissive Radiation Measurements During the Pitch Maneuver

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the newly launched (November 18, 2017) Joint Polar Satellite System-1 (JPSS-1), now transitioned to NOAA-20, and the Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its on-board calibration components include a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft level pitch maneuver was scheduled during the initial intensive Cal/Val testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire scan angle range, which can be used to characterize the TEB RVS. This study provides our analysis of the NOAA-20 pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half angle mirror.

VIIRS↗

Determination of Response Versus Scan Angle for the NOAA-20 Visible Infrared Imaging Radiometer Suite Thermal Emissive Bands from Emissive Radiation Measurements During the Pitch Maneuver

The visible infrared imaging radiometer suite (VIIRS) is a key sensor onboard the newly launched (November 18, 2017) NOAA-20 satellite and the early launched Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its onboard calibration components include a solar diffuser (SD) and a SD stability monitor for the reflective solar bands, a V-grooved blackbody for the thermal emissive bands (TEBs),and a space view port for background subtraction. These onboard calibrators are located at fixed scan angles. The response versus scan angle (RVS) of the VIIRS scan mirror was characterized prelaunch in lab-ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft-level pitch maneuver was scheduled during the initial intensive calibration and validation testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of the scan angle, which can be used to characterize the TEBRVS. We analyze the NOAA-20 pitch maneuver data and assess the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half-angle mirror.

Wu, Aisheng↗

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

First Measurements of Ambient PM2.5 in Kinshasa, Democratic Republic of Congo and Brazzaville, Republic of Congo Using Field-calibrated Low-cost Sensors

Estimates of air pollution mortality in sub-Saharan Africa are limited by a lack of surface observations of fine particulate matter (PM2.5). Despite being large metropolises, Kinshasa, Democratic Republic of the Congo (DRC), population 14.3 million, and Brazzaville, Republic of the Congo (ROC), population 2.4 million, have no reference air pollution monitors at the time of writing. Recently, a few reference monitors have been deployed in other parts of sub-Saharan Africa, including Kampala, Uganda. A low-cost PurpleAir PM2.5 monitor was collocated next to the Kampala US Embassy BAM-1020 (Met One Beta Attenuation Monitor) starting in August 2019. Raw PurpleAir data are strongly correlated with the BAM (r(exp 2) = 0.88), but have a mean absolute error of approximately 14 μg/cu.m. Two calibration models, multiple linear regression and a random forest approach, decrease mean absolute error (MAE) from 14.3 μg/cu.m to 3.4 µg/cu.m or less and improve the the r(exp 2) from 0.88 to 0.96. Given )the similarity in climate and emissions in Kampala, we apply the collocated field correction factors to four PurpleAir sensors in Kinshasa, DRC and one in neighboring Brazzaville, ROC deployed beginning April 2018. Annual average PM2.5 for 2019 in Kinshasa is estimated at 43.5 µg/cu.m, more than 4 times higher than WHO Interim Target 1 of 10 µg/cu.m. Surface PM2.5 and aerosol optical depth were each about 40% lower during the 2020 COVID19 lockdown period compared to the same time period in 2019, which cannot be explained by changes in meteorology or wildfire emissions alone. Our results highlight the need for clean air solutions implementation in the Congo.

Celeste McFarlane↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. The system comprises any number of transmitting units and a single receiving unit (see figure). Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal- conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient-temperature sensor that is in addition to the external thermocouples. The control module is a "system-on-chip" embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display.

Solano, Wanda↗

The Lusi seismic experiment: An initial study to understand the effect of seismic activity to Lusi

The spectacular Lumpur Sidoarjo (Lusi) eruption started in northeast Java on the 29 of May 2006 following a M6.3 earthquake striking the island [1,2]. Initially, several gas and mud eruption sites appeared along the reactivated strike-slip Watukosek fault system [3] and within weeks several villages were submerged by boiling mud. The most prominent eruption site was named Lusi. The Lusi seismic experiment is a project aims to begin a detailed study of seismicity around the Lusi area. In this initial phase we deploy 30 seismometers strategically distributed in the area around Lusi and along the Watukosek fault zone that stretches between Lusi and the Arjuno Welirang (AW) complex. The purpose of the initial monitoring is to conduct a preliminary seismic campaign aiming to identify the occurrence and the location of local seismic events in east Java particularly beneath Lusi.This network will locate small event that may not be captured by the existing BMKG network. It will be crucial to design the second phase of the seismic experiment that will consist of a local earthquake tomography of the Lusi-AW region and spatial and temporal variations of vp/vs ratios. The goal of this study is to understand how the seismicity occurring along the Sunda subduction zone affects to the behavior of the Lusi eruption. Our study will also provide a large dataset for a qualitative analysis of earthquake triggering studies, earthquake-volcano and earthquake-earthquake interactions. In this study, we will extract Green’s functions from ambient seismic noise data in order to image the shallow subsurface structure beneath LUSI area. The waveform cross-correlation technique will be apply to all of recordings of ambient seismic noise at 30 seismographic stations around the LUSI area. We use the dispersive behaviour of the retrieved Rayleigh waves to infer velocity structures in the shallow subsurface.

58 GEOSCIENCES↗

Investigations on the Origin of Topotactic Phase Transition of LaCoO 3 Thin Films with In Situ XRD and Ambient Pressure Hard X-ray Photoelectron Spectroscopy

With the applications of in situ X-ray diffraction (XRD), electrical I–V measurement, and ambient pressure hard X-ray photoelectron spectroscopy (AP-HAXPES), the characteristics of the topotactic phase transition of LaCoO 3 (LCO) thin films are examined. XRD measurements show clear evidence of structural phase transition (SPT) of the LCO thin films from the perovskite (PV) LaCoO 3 to the brownmillerite (BM) La 2 Co 2 O 5 phases through the intermediate La 3 Co 3 O 8 phase at a temperature of 350 °C under high-vacuum conditions, ~10 –5 mbar. The reverse SPT from BM to PV phases is also found under ambient pressure (>100 mbar) of air near 100 °C. Both observed SPTs in XRD are also identified in the electrical I–V measurements, i.e., the metallic PV phase to the insulating BM phase and vice versa. During the onset of SPTs, the bulk chemical and electronic states of LCO thin films are monitored with AP-HAXPES. The oxidation states in Co 2p spectra indicate that the oxygen vacancies are closely related to the SPT of LCO thin films. Also, the presence of enlarged band gap is observed as the SPT from PV to BM phases takes place, revealing the modified electronic properties of LCO due to the creation of oxygen vacancies. In conclusion, the analysis of valence band structures is further compared to the I–V measurements.

36 MATERIALS SCIENCE↗

Distributed Acoustic Sensing Using Dark Fiber for Near-Surface Characterization and Broadband Seismic Event Detection

We present one of the first case studies demonstrating the use of distributed acoustic sensing deployed on regional unlit fiber-optic telecommunication infrastructure (dark fiber) for broadband seismic monitoring of both near-surface soil properties and earthquake seismology. We recorded 7 months of passive seismic data on a 27 km section of dark fiber stretching from West Sacramento, CA to Woodland, CA, densely sampled at 2 m spacing. This dataset was processed to extract surface wave velocity information using ambient noise interferometry techniques; the resulting VS profiles were used to map both shallow structural profiles and groundwater depth, thus demonstrating that basin-scale variations in hydrological state could be resolved using this technique. The same array was utilized for detection of regional and teleseismic earthquakes and evaluated for long period response using records from the M8.1 Chiapas, Mexico 2017, Sep 8th event. The combination of these two sets of observations conclusively demonstrates that regionally extensive fiber-optic networks can effectively be utilized for a host of geoscience observation tasks at a combination of scale and resolution previously inaccessible.

58 GEOSCIENCES↗

Infrared monitoring of the Space Station environment

The measurement and monitoring of infrared emission in the environment of the Space Station has a twofold importance - for the study of the phenomena itself and as an aid in planning and interpreting Station based infrared experiments. Spectral measurements of the infrared component of the spacecraft glow will, along with measurements in other spectral regions, provide data necessary to fully understand and model the physical and chemical processes producing these emissions. The monitoring of the intensity of these emissions will provide background limits for Space Station based infrared experiments and permit the determination of optimum instrument placement and pointing direction. Continuous monitoring of temporal changes in the background radiation (glow) will also permit better interpretation of Station-based infrared earth sensing and astronomical observations. The primary processes producing infrared emissions in the Space Station environment are: (1) Gas phase excitations of Station generated molecules ( e.g., CO2, H2O, organics...) by collisions with the ambient flux of mainly O and N2. Molecular excitations and generation of new species by collisions of ambient molecules with Station surfaces. They provide a list of resulting species, transition energies, excitation cross sections and relevant time constants. The modeled spectrum of the excited species occurs primarily at wavelengths shorter than 8 micrometer. Emissions at longer wavelengths may become important during rocket firing or in the presence of dust.

Kostiuk, Theodor↗

Measuring the Aerosol Collection Efficiency and Detector Face Deposition of the Bladewerx KatanaGBM™ (Glove Box Monitor) Continuous Air Monitor

To assist Bladewerx LLC (the Requestor) in testing their new CAM (continuous air monitor) sampler model Bladewerx™ KatanaGBM™ (Glove Box Monitor), the Laboratory (LANL, i.e. Los Alamos National Laboratory) measured the aerosol particle collection efficiency and detector face deposition for several experimental test conditions. Bladewerx LLC provided a prototype KatanaGBM with a set of requested tests. According to these parameters, LANL designed and performed a series of experiments to (A.) Measure the aerosol particle collection efficiency and detector face deposition of the KatanaGBM at three air flow rates of 5, 42, and 70 ALPM (ambient liters per minute), (B.) Measure the collection efficiency and detector face deposition using two sizes of oil droplet particles: 3±1 and 10±1 µm (micron) AED (aerodynamic equivalent diameter), and (C.) Test the KatanaGBM for aerosol collection efficiency and detector face deposition with the wind tunnel’s air flow at three different angles 0°, 45° and 90° (compared to the KatanaGBM’s filter face).

61 RADIATION PROTECTION AND DOSIMETRY↗

A Bayesian Machine Learning Model for Estimating Building Occupancy from Open Source Data

Understanding building occupancy is critical to a wide array of applications including natural hazards loss analysis, green building technologies, and population distribution modeling. Due to the expense of directly monitoring buildings, scientists rely in addition on a wide and disparate array of ancillary and open source information including subject matter expertise, survey data, and remote sensing information. These data are fused using data harmonization methods which refer to a loose collection of formal and informal techniques for fusing data together to create viable content for building occupancy estimation. In this paper, we add to the current state of the art by introducing the Population Data Tables (PDT), a Bayesian based informatics system for systematically arranging data and harmonization techniques into a consistent, transparent, knowledge learning framework that retains in the final estimation uncertainty emerging from data, expert judgment, and model parameterization. PDT probabilistically estimates ambient occupancy in units of people/1000ft2 for over 50 building types at the national and sub-national level with the goal of providing global coverage. The challenge of global coverage led to the development of an interdisciplinary geospatial informatics system tool that provides the framework for capturing, storing, and managing open source data, handling subject matter expertise, carrying out Bayesian analytics as well as visualizing and exporting occupancy estimation results. We present the PDT project, situate the work within the larger community, and report on the progress of this multi-year project.Understanding building occupancy is critical to a wide array of applications including natural hazards loss analysis, green building technologies, and population distribution modeling. Due to the expense of directly monitoring buildings, scientists rely in addition on a wide and disparate array of ancillary and open source information including subject matter expertise, survey data, and remote sensing information. These data are fused using data harmonization methods which refer to a loose collection of formal and informal techniques for fusing data together to create viable content for building occupancy estimation. In this paper, we add to the current state of the art by introducing the Population Data Tables (PDT), a Bayesian model and informatics system for systematically arranging data and harmonization techniques into a consistent, transparent, knowledge learning framework that retains in the final estimation uncertainty emerging from data, expert judgment, and model parameterization. PDT probabilistically estimates ambient occupancy in units of people/1000 ft 2 for over 50 building types at the national and sub-national level with the goal of providing global coverage. The challenge of global coverage led to the development of an interdisciplinary geospatial informatics system tool that provides the framework for capturing, storing, and managing open source data, handling subject matter expertise, carrying out Bayesian analytics as well as visualizing and exporting occupancy estimation results. We present the PDT project, situate the work within the larger community, and report on the progress of this multi-year project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗