Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

The MANX Muon Cooling Experiment Detection System

The MANX experiment is being proposed to demonstrate the reduction of 6D muon phase space emittance, using a continuous liquid absorber to provide ionization cooling in a helical solenoid magnetic channel. The experiment involves the construction of a two-period-long helical cooling channel (HCC) to reduce the muon invariant emittance by a factor of two. The HCC would replace the current cooling section of the MICE experiment now being set up at the Rutherford Appleton Laboratory. The MANX experiment would use the existing MICE spectrometers and muon beam line. We discuss the placement of detection planes to optimize the muon track resolution.

43 PARTICLE ACCELERATORS↗

Status of the International Design Study of the Neutrino Factory

The International Design Study for the Neutrino Factory (the IDS-NF) has been established by the Neutrino Factory community to deliver the Reference Design Report (RDR) for the facility by 2012. The baseline design for the facility, developed from that defined in the International Scoping Study of a future Neutrino Factory and super-beam facility (the ISS), will provide 10{sup 21} muon decays per year from 25 GeV stored muon beams. The facility will serve two neutrino detectors; one situated at source-detector distance of between 3000-5000 km, the second at 7000-8000 km. The baseline design for the facility will be described and the status of the IDS-NF effort will be summarised.

43 PARTICLE ACCELERATORS↗

Abel transform analysis of ion storage ring imaging data

In this paper a new approach to analyze dissociative recombination product distance distributions measured at ion storage rings is presented. This approach is based on an Abel transform and the validity is demonstrated for the imaging data obtained from the CRYRING experiments on the dissociative recombination of H{sub 2}{sup +} and CO{sup +}. The reported method is generally valid for the data analysis of high resolution merged beams experiments such as DESIREE where isotropic fragment distributions can be expected.

43 PARTICLE ACCELERATORS↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Nanoradian angular stabilization of x-ray optical components

An x-ray free-electron laser oscillator (XFELO) has been recently proposed [K. Kim et al., Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate for the instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko, Phys. Rev. ST Accel. Beams 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high-energy-resolution x-ray monochromator ({Delta}E/E{approx_equal}4x10{sup -8}, E=23.7 keV) and a high-heat-load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.

43 PARTICLE ACCELERATORS↗

A compact, sample-in-atmospheric-pressure soft x-ray microscope developed at Pohang Light Source

A full-field transmission soft x-ray microscope (TXM) was developed at the Pohang Light Source. With a 2 mm diameter condenser zone plate and a 40 nm outermost-zone-width objective zone plate, the TXM's achieved spatial resolution is better than 50 nm at the photon energy of 500 eV (wavelength: 2.49 nm). The TXM is portable and mounted in tandem with a 7B1 spectroscopy end station. The sample position is outside the vacuum, allowing for quick sample changes and enhanced in situ experimental capability. In addition, the TXM is pinhole-free and easy to align, having commercial mounts located outside the vacuum components.

43 PARTICLE ACCELERATORS↗

A simple double-focusing electrostatic ion beam deflector

We have developed an electrostatic, double-focusing 90 deg. deflector for fast ion beams consisting of concentric cylindrical plates of differing heights. In contrast to standard cylindrical deflectors, our design allows for focusing of an incoming parallel beam not only in the plane of deflection but also in the orthogonal direction. The optical properties of our design resemble those of a spherical capacitor deflector while it is much easier and more cost effective to manufacture.

43 PARTICLE ACCELERATORS↗

Automated high pressure cell for pressure jump x-ray diffraction

A high pressure cell for small and wide-angle x-ray diffraction measurements of soft condensed matter samples has been developed, incorporating a fully automated pressure generating network. The system allows both static and pressure jump measurements in the range of 0.1-500 MPa. Pressure jumps can be performed as quickly as 5 ms, both with increasing and decreasing pressures. Pressure is generated by a motorized high pressure pump, and the system is controlled remotely via a graphical user interface to allow operation by a broad user base, many of whom may have little previous experience of high pressure technology. Samples are loaded through a dedicated port allowing the x-ray windows to remain in place throughout an experiment; this facilitates accurate subtraction of background scattering. The system has been designed specifically for use at beamline I22 at the Diamond Light Source, United Kingdom, and has been fully integrated with the I22 beamline control systems.

43 PARTICLE ACCELERATORS↗

Note: New design of a cryogenic linear radio frequency multipole trap

A new design of a cryogenic linear 22-pole ion trap has been constructed and tested. It is essentially a copper housing to which opposite inner walls two electrode sets are attached via sapphire insulators. These stainless steel electrodes are electroformed in one piece to guarantee good heat conduction. Connected to an external coil, they form an LC-circuit of about 19 MHz resonance frequency. This circuit is excited with a rf power supply made of a commercial digital synthesizer followed by a 10 W amplifier. Buffer gas-cooled H{sub 2}D{sup +} ions have been stored in this trap at a nominal trap temperature of 14 K. Spectroscopy of the ions confirmed that the kinetic (Doppler) temperature is in reasonable agreement with this value.

43 PARTICLE ACCELERATORS↗

Study on the Effect of Energy Parameter of Electron on the Percentage Depth Dose of Electron Beam Using Monte Carlo Method

In medical linear accelerator, the energy parameter of electron plays important role to produce electron beam. The percentage depth dose of electron beams takes account not only on the value of electron's energy, but also on the type of electron's energy. The aims of this work are to carry on the effect of energy parameter of electron on the percentage depth dose of electron beam. Monte Carlo method is chosen in this project, due to the superior of this method for simulating the random process such as the transport particle in matter. The DOSXYZnrc usercode was used to simulate the electron transport in water phantom. Two aspects of electron's energy parameter were investigated using Monte Carlo simulations. In the first aspect, electron energy's value was varied also its spectrum. In the second aspect, the geometry of electron's energy was taken account on. The parallel beam and the point source were chosen as the geometry of The measurements of percentage depth dose were conducted to compare with its simulation. The ionization chamber was used in these measurements. Presentation of the results of this work is given not only based on the shape of the percentage depth dose from the simulation and measurement, but also on the other aspect in its curve. The result of comparison between the simulation and its measurement shows that the shape of its curve depends on the energy value of electron and the type of its energy. The energy value of electron affected the depth maximum of dose.

07 ISOTOPE AND RADIATION SOURCES↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Measurement of the Magnet Blocks for SSRF Insertion Devices

Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm{sub 2}Co{sub 17} magnet blocks and the dimension of blocks is 65 Wx25 Hx9 D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35 Wx35 Hx25 D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum angle deviation are less than {+-}1.0% and 1.1 deg. respectively both for Sm{sub 2}Co{sub 17} blocks and NdFeB blocks and satisfy the specifications of undulators.

43 PARTICLE ACCELERATORS↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

Design and Technical Aspects of a New in Vacuum Transfocator at ESRF Beamline ID11

A tunable X-Ray focusing apparatus based on compound refractive lenses (CRL), referred to as a transfocator, has been installed for monochromatic beam (IAT in air transfocator) two years ago in the second optics hutch at ID11 at the ESRF. By varying the number of lenses in the beam, the energy focused and the focal length can be varied continuously throughout a large range of energies and distances.Based the success of the IAT, an in-vacuum transfocator (IVT) has now been built and installed at ID11.The aim of this poster is to describe and show the mechanical and technical solutions used to design and manufacture this new IVT.The IVT was installed last January in the first optics hutch at ID11. The IVT consists of nine water cooled cartridges containing 1, 2, 4, 8, 16, 32 Be lenses, and 32 and 64 Al lenses, and a protective aperture of Oe 900 {mu}m. The mechanical design is based on a system of pneumatically actuated cartridges with an auto positioning on two stainless steel rods. The vacuum vessel has translations and rotations perpendicular to the beam direction in order to align the axis of the cartridges with the x-ray beam.

43 PARTICLE ACCELERATORS↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗