Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Successful Antibiotic Treatment of Severe Staphylococcal Infection of a Long Stent Graft in the Superficial Femoral Artery with Graft Preservation in the Long Term

Introduction: Bacterial infection of endovascular stent grafts is a serious condition, regularly leading to graft replacement by open bypass surgery.Case ReportWe describe the case of a staphylococcal infection of a 150-mm covered stent graft (Gore Viabahn), placed in the superficial femoral artery. Stent graft infection was successfully treated by oral administration of penicillinase-resistant flucloxacillin and the lipopeptide daptomycin with complete graft preservation, not requiring surgical treatment. During 1-year follow-up, the graft infection did not reappear. However, the patient developed restenosis at the proximal margin of the stent with recurrence of mild claudication, so far treated conservatively. Conclusion: With the increased use of covered stent grafts in the peripheral vasculature, the frequency of graft infection will increase. We demonstrate that with newly developed antibiotics, it is possible to treat this severe complication conservatively, with complete graft preservation and without the need for bypass surgery in selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Complex Renal Artery Aneurysms Using the Multilayer Stent

Since its approval as an innovative stent system for peripheral aneurysm management in May 2009, the Cardiatis Multilayer Stent (Cardiatis, Isnes, Belgium) has been applied in several clinical cases. The unique design of this multilayer stent decreases mean velocity and vorticity within the aneurysm sac immediate and causes thrombus to form, resulting in physiological exclusion of the aneurysm from the circulation, whereas branches and collaterals sprouting from the aneurysm remain patent. Here we present a case of a complex renal artery aneurysm successfully treated with a 6 Multiplication-Sign 30-mm Cardiatis Multilayer Stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Efficacy of the Embolic Agents Acrylamido Polyvinyl Alcohol Microspheres and Tris-Acryl Gelatin Microspheres for Uterine Artery Embolization for Leiomyomas: A Prospective Randomized Controlled Trial

Objective: To evaluate the efficacy of acrylamido polyvinyl alcohol microspheres (a-PVAM) as an embolic agent for uterine artery embolization (UAE) compared with Tris-acryl gelatin microspheres (TAGM).Design, Setting, ParticipantsProspective randomized double-blind noninferiority trial. Conducted at two sites both with regional UAE practices. Forty-six women with symptomatic leiomyomas.InterventionUAE procedure was performed with either of the two embolic agents. Either 700-900-{mu}m a-PVAM or 500-700-{mu}m TAGM was used.Main Outcome MeasuresChanges in leiomyoma perfusion, overall uterine volume, and dominant leiomyomas volume measured by contrast-enhanced magnetic resonance imaging at 1 week, 3 months, and 6 months after UAE by a reader blinded to the embolic agent used. Changes in Uterine Fibroid Symptoms and Quality of Life questionnaire scores were measured at 3, 6, and 12 months after UAE. Results: Forty-six patients were randomized and treated under the study protocol (a-PVAM n = 22, TAGM n = 24). There were no procedure-related complications. Two patients were excluded from analysis (one technical failure of the procedure, one withdrawal from study). Successful (>90%) leiomyoma devascularization was observed in 81% of subjects at 1 week after UAE, 97% at 3 months after UAE, and 95% at 6 months after UAE. No significant differences were observed in 14 of 15 outcome measurements, consistent with noninferiority. TAGM was slightly superior to a-PVAM on one comparison (overall quality of life at 3 months after UAE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of an Internal Iliac Artery Aneurysm after Image-Guided Direct Puncture

Objective: To evaluate the feasibility, safety, and efficacy of embolization of internal iliac artery aneurysm (IIAA) after percutaneous direct puncture under (cone-beam) computed tomography (CT) guidance. Methods: A retrospective case series of three patients, in whom IIAA not accessible by way of the transarterial route, was reviewed. CT-guided puncture of the IIAA sac was performed in one patient. Two patients underwent puncture of the IIAA under cone-beam CT guidance. Results: Access to the IIAA sac was successful in all three patients. In two of the three patients, the posterior and/or anterior division was first embolized using platinum microcoils. The aneurysm sac was embolized with thrombin in one patient and with a mixture of glue and Lipiodol in two patients. No complications were seen. On follow-up CT, no opacification of the aneurysm sac was seen. The volume of one IIAA remained stable at follow-up, and the remaining two IIAAs decreased in size. Conclusion: Embolization of IIAA after direct percutaneous puncture under cone-beam CT/CT-guidance is feasible and safe and results in good short-term outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non-contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47-2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Case of Lipiduria After Arterial Embolization for Renal Angiomyolipomas

We report the case of a 31-year-old woman who suffered lipiduria after selective transcatheter arterial embolization for renal angiomyolipoma (AML). Computed tomography confirmed cystic liquefactive necrosis with fat-fluid level in AML. Although the process by which AML fat tissue excretion occurs is not clear, we speculated that the infarcted AML was connected to the urinary collection duct system and subsequently its adipose component was excreted into the urine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transosseous Embolization of Internal Iliac Artery Aneurysm Type II Endoleak: Report of Two Cases

This report describes two cases of successful treatment of an internal iliac artery aneurysm (IIAA) type II endoleak utilizing a percutaneous transosseous access that could not be treated using an endovascular or standard percutaneous approach. A direct percutaneous approach through bone was chosen to avoid vital structures and the surrounding bowel. The procedure was successful and required minimal fluoroscopy time compared with other treatment options. We believe this procedure is an alternative to some of the more complex and technically challenging means of treating this lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior Vena Cava Stent Migration into the Pulmonary Artery Causing Fatal Pulmonary Infarction

Migration of superior vena cava (SVC) stents is a well-recognised complication of their deployment, and numerous strategies exist for their retrieval. To our knowledge, only three cases of migration of an SVC stent to the pulmonary vasculature have previously been reported. None of these patients developed complications that resulted in death. We report a case of SVC stent migration to the pulmonary vasculature with delayed pulmonary artery thrombosis and death from pulmonary infarction. We conclude that early retrieval of migrated stents should be performed to decrease the risk of serious complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Clinical Results After Percutaneous Angioplasty in Nonmedial Fibromuscular Dysplasia: Outcome After Endovascular Management of Unifocal Renal Artery Stenoses in 30 Patients

Although percutaneous transluminal renal angioplasty (PTRA) is associated with excellent results in medial fibromuscular dysplasia (FMD), the clinical and technical outcome in the less common nonmedial subtype of FMD is not clearly known. Angiographic PTRA results and clinical follow-up were documented, to report technical and clinical results in 30 patients with unifocal, nonmedial dysplastic stenoses. Balloon angioplasty was technically successful in only 65% of the lesions. Additional stenting, performed after PTRA failure in six patients, increased the initial technical success rate to 82%. Stenting was used in another lesion after restenosis, and long-term patency was achieved in only three of the seven stented lesions. Frequent restenoses and unusual complications were observed during follow-up. Stent fracture occurred in two cases. Overall, long-term clinical and technical successes were sustained in 70 and 76%, respectively. We conclude that nonmedial, unifocal renal artery dysplastic stenoses do not share the excellent prognosis of the medial type and that stenting should be avoided. Therefore, surgery should be considered in lesions remaining unresponsive to balloon dilatation, after a second PTRA attempt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Size Really Matter? Analysis of the Effect of Large Fibroids and Uterine Volumes on Complication Rates of Uterine Artery Embolisation

The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diameter of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Device for True Lumen Re-Entry After Subintimal Recanalization of Superficial Femoral Arteries: First-in-Man Experience and Technical Description

Subintimal angioplasty (SAP) is frequently performed for the treatment of critical limb ischemia (CLI) and has been recognized as an effective technique for these patients. Nevertheless, this approach is limited by the lack of controlled re-entry into the true lumen of the target vessel. We describe a novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries (SFA). We report our experience with six patients treated between April 2009 and January 2010 with a novel system designed to facilitate true lumen re-entry. The device was advanced by ipsilateral antegrade approach through a 6-French sheath. Successful reaccess into the true lumen was obtained in five of six patients without complications. The patient in whom the reaccess to the true lumen was not possible underwent successful bypass surgery. At 30 days follow-up, the SFA was patent in all patients according to echo-Doppler examination. Our preliminary experience indicates that this novel re-entry device increases the success rate of percutaneous revascularization of chronically occluded SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting-Balloon Angioplasty in Transplant Renal Artery Stenosis as First-Line Treatment in the Early Postoperative Period

Percutaneous transluminal angioplasty has been successfully used for the treatment of transplant renal artery stenosis (RAS). Cutting-balloon angioplasty (CBA) is being used as a second option in pressure-resistant stenosis. It is thought that CBA is less traumatic and therefore restenosis occurs less frequently than in conventional angioplasty. This case report describes the unusual use of a cutting balloon in transplant RAS as a first option in the early postoperative period. Long-term follow-up data are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as {<=}30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 {+-} 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 {+-} 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 {+-} 10%. ABI improved from 0.56 {+-} 0.16 to 0.92 {+-} 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in all 29 patients. Debris particle size ranged from 90 to 2000 {mu}m (1200 {+-} 640). Histological debris analysis showed platelets, erythrocytes, inflammatory cells, extracellular matrix, and cholesterol as being the major components of emboli. Additional immunochemistry showed no correlation between lesion morphology and debris components. The FilterWire EZ is easy and safe to handle. The system caused no complications. In all cases, macroscopic debris was captured. Using a distal protection device during femoropopliteal interventions has the potential to prevent migration of debris, which may be important for high-risk patients with limited distal runoff.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization Combined with Local Methotrexate and Systemic Methotrexate for Treatment of Cesarean Scar Pregnancy with Different Ultrasonographic Pattern

Purpose: This study was designed to compare the effectiveness of systemic methotrexate (MTX) with uterine artery embolization (UAE) combined with local MTX for the treatment of cesarean scar pregnancy (CSP) with different ultrasonographic pattern, and to indicate the preferable therapy in CSP patients. Methods: The results of 21 CSP cases were reviewed. All subjects were initially administrated with systemic MTX (50 mg/m{sup 2} body surface area). UAE combined with local MTX was added to the patients who had failed systemic MTX. The transvaginal ultrasonography data were retrospectively assessed, and two different ultrasonographic patterns were found: surface implantation and deep implantation of amniotic sac. The management and its effectiveness for patients with the two ultrasonographic patterns were studied retrospectively. Ultrasound scan and serum {beta}-hCG were monitored during follow-up. Data were analyzed with the Student's t test. Results: Nine patients were successfully treated with systemic MTX. The remaining 12 cases were successfully treated with additional UAE combined with local MTX. According to the classification by Vial et al. of CSP on ultrasonography, most surface implanted CSPs (8/11, 72.7%) could be successfully treated with systemic MTX, whereas most deeply implanted CSPs (9/10, 90%) had failed systemic MTX but still could be successfully treated with additional UAE combined with local MTX. All patients recovered without severe side effects. Most patients with a future desire for reproduction achieved subsequent pregnancy. Conclusions: For CSP patients suitable for nonsurgical treatment, UAE combined with local MTX would be the superior option compared with systemic MTX in the cases with deep implantation of amniotic sac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗