Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures (September 2011 - August 2020)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of PEM Liquid-Feed Direct Methanol-Air Fuel Cells

A direct methanol-air fuel cell operating at near atmospheric pressure, low-flow rate air, and at temperatures close to 60oC would tremendously enlarge the scope of potential applications. While earlier studies have reported performance with oxygen, the present study focuses on characterizing the performance of a PEM liquid feed direct methanol-air cell consisting of components developed in house. These cells employ Pt-Ru catalyst in the anode, Pt at the cathode and Nafion 117 as the PEM. The effect of pressure, flow rate of air and temperature on cell performance has been studied. With air, the performance level is as high as 0.437 V at 300 mA/cm2 (90oC, 20 psig, and excess air flow) has been attained. Even more significant is the performance level at 60oC, 1 atm and low flow rates of air (3-5 times stoichiometric), which is 0.4 V at 150 mA/cm2. Individual electrode potentials for the methanol and air electrode have been separated and analyzed. Fuel crossover rates and the impact of fuel crossover on the performance of the air electrode have also been measured. The study identifies issues specific to the methanol-air fuel cell and provides a basis for improvement strategies.

Methanol-Air Fuel↗

Results from CrIS-ATMS Obtained Using the AIRS Science Team Retrieval Methodology

AIRS was launched on EOS Aqua in May 2002, together with AMSU-A and HSB (which subsequently failed early in the mission), to form a next generation polar orbiting infrared and microwave atmospheric sounding system. AIRS/AMSU had two primary objectives. The first objective was to provide real-time data products available for use by the operational Numerical Weather Prediction Centers in a data assimilation mode to improve the skill of their subsequent forecasts. The second objective was to provide accurate unbiased sounding products with good spatial coverage that are used to generate stable multi-year climate data sets to study the earth's interannual variability, climate processes, and possibly long-term trends. AIRS/AMSU data for all time periods are now being processed using the state of the art AIRS Science Team Version-6 retrieval methodology. The Suomi-NPP mission was launched in October 2011 as part of a sequence of Low Earth Orbiting satellite missions under the "Joint Polar Satellite System" (JPSS). NPP carries CrIS and ATMS, which are advanced infra-red and microwave atmospheric sounders that were designed as follow-ons to the AIRS and AMSU instruments. The main objective of this work is to assess whether CrIS/ATMS will be an adequate replacement for AIRS/AMSU from the perspective of the generation of accurate and consistent long term climate data records, or if improved instruments should be developed for future flight. It is critical for CrIS/ATMS to be processed using an algorithm similar to, or at least comparable to, AIRS Version-6 before such an assessment can be made. We have been conducting research to optimize products derived from CrIS/ATMS observations using a scientific approach analogous to the AIRS Version-6 retrieval algorithm. Our latest research uses Version-5.70 of the CrIS/ATMS retrieval algorithm, which is otherwise analogous to AIRS Version-6, but does not yet contain the benefit of use of a Neural-Net first guess start-up system which significantly improved results of AIRS Version-6. Version-5.70 CrIS/ATMS temperature profile and surface skin temperature retrievals are of very good quality, and are better than AIRS Version-5 retrievals, but are still significantly poorer than those of AIRS Version-6. CrIS/ATMS retrievals should improve when a Neural-Net start-up system is ready for use. We also examined CrIS/ATMS retrievals generated by NOAA using their NUCAPS retrieval algorithm, which is based on earlier versions of the AIRS Science Team retrieval algorithms. We show that the NUCAPS algorithm as currently configured is not well suited for climate monitoring purposes.

CrIS↗

Evaluation of Climate Fingerprinting Sounder Product (ClimFiSP) Air Temperature and H2O Trends

Climate fingerprinting Sounder Product (ClimFiSP) provides gridded (0.5x0.5) daily skin temperature, surface emissivity, air temperature, water vapor, trace gases, and cloud properties, which derived from IR hyper-spectral radiance measured by AIRS on Aqua and CrIS on SNPP and JPSS series. In this work, the ClimFiSP daily air temperature and H2O were retrieved on 98 pressure levels by applying the spectral fingerprint algorithm on 0.5x0.5 gridded daily mean radiances from Climate Hyperspectral Infrared Radiance Product (CHIRP). CHIRP is a stable climate-quality radiance time series spanning AIRS and CrIS. The air temperature and H2O monthly data and trends were calculated from the more than two decades long CHIRP AIRS data. Troposphere warming and stratosphere cooling can be seen in both ClimFiSP and ERA5 air temperature data. The ClimFiSP air temperature trends are also compared with the MW sounding air temperature trends to validate the ClimFiSP air temperature results. The H2O trends on upper troposphere are evaluated by comparing with the ERA5 H2O trends, and results show a reasonable agreement with two sets of results. The ClimFiSP algorithm provides a unique and fast way to retrieve the spatial-temporal change in climate variables from the corresponding change in radiances, gridded at the same spatial-temporal scale. This greatly facilitates the procession of long-term climate data records.

ClimFiSP↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions, Calendar Year 2010

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada National Security Site (NNSS, formerly the Nevada Test Site) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as those from the damaged Fukushima nuclear power plant in Japan. Because this report is intended to discuss radioactive air emissions during calendar year 2010, data on radionuclides in air from the 2011 Fukushima nuclear power plant releases are not presented but will be included in the report for calendar year 2011. The NNSS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations (U.S. Environmental Protection Agency [EPA] and DOE, 1995). This method was approved by the EPA for use on the NNSS in 2001(EPA, 2001a) and has been the sole method used since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR, 2010a). For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide's concentration by its CL and then adding the fractions together) is less than 1.0. In 2010, the potential dose from radiological emissions to air, resulting from both current and past NNSS activities, at onsite compliance monitoring stations was well below the 10 mrem/yr dose limit. Air sampling data collected at all air monitoring stations had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides about 20 kilometers from potential release points on the NNSS, dose to the public would be only a small fraction of that measured on the NNSS. The potential dose to the public from NLVF emissions was also very low at 0.000032 mrem/yr, more than 300,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Emission Cargo Transport (ZECT) II Demonstration: South Coast Air Quality Management District (Final Report)

The South Coast Air Quality Management District (South Coast AQMD), California Air Resources Board (CARB) and Southern California Association of Governments (SCAG) — the agencies responsible for preparing the State Implementation Plan required under the federal Clean Air Act — have agreed that attainment of federal air quality standards for the region will require a transition to the broad use of zero and near-zero emission energy sources in cars, trucks and other equipment. Accordingly, the 2012 South Coast AQMD Air Quality Management Plan, the SCAG 2012 Regional Transportation Plan, and the “Vision for Clean Air: A Framework for Air Quality and Climate Control Planning” all identify the need to immediately enact a phasing in of zero and near-zero emission technologies to meet air quality goals. In 2014, South Coast AQMD was awarded grant funding under the US Department of Energy Zero Emission Cargo Transport (ZECT) II Demonstration program to develop and demonstrate zero-emission drayage trucks for goods movement operations between the Port of Los Angeles (POLA) and Port of Long Beach (POLB) near dock rail yards and warehouses: 1) development and demonstration of zero-emission fuel cell range extended electric drayage trucks and 2) development and demonstration of hybrid electric drayage trucks. The purpose of this project was to accelerate deployment of zero emission cargo transport technologies to reduce harmful diesel emissions, petroleum consumption and greenhouse gases in the surrounding communities along the goods movement corridors that are impacted by heavy diesel traffic and the associated air pollution. Between 2014 – 2024, six ZECT II zero-emission fuel cell drayage truck platforms, including fuel cell range extended and CNG hybrid trucks, were successfully designed, developed, integrated, built, tested, and demonstrated with drayage fleet operators in transportation corridors within areas of the South Coast AQMD jurisdiction in Southern California such as in and around POLA and POLB. Portable hydrogen refueling was deployed to support the fuel cell vehicles. The project had real-time improvement with on-going debugging and optimizations while the vehicles were under demonstration. All platforms demonstrated sufficient or excess power, torque, and energy to support 82,000lbs Gross Vehicle Weight Rating and gradeability to perform their daily duty cycles. Collectively, the trucks drove over 23,000 miles during their respective demonstration phases. The ZECT II project was the first of its kind to demonstrate the commercial viability that supported the additional technology breakthroughs for Class 8 zero emission trucks and validations as well as the regulatory basis for all the zero-emission regulation that we know today, such as the Innovative Clean Transit regulation, Advanced Clean Trucks and Clean Fleet regulations.

08 HYDROGEN↗

Air temperature changes in Svalbard and the surrounding seas from 1865 to 1920

In this article, air temperature variability in the Svalbard region (74–82°N, 6–30°E) from 1865 to 1920 is presented based on a large amount of early instrumental land and marine data. Measurements were taken during many exploratory and scientific expeditions to the study area. In addition, changes of air temperature from historical times to the present day (1981–2010) were investigated. Present-day air temperatures for land were taken from regular meteorological stations and from campaign measurements, while for marine environment data were taken from three reanalysis products: 20CR, ERA-20C and ERA-Interim. Analysis reveals that Svalbard (land data) in the period 1865–1920 was markedly colder than today (1981–2010, by about 3 °C) in all seasons except summer, when air temperature was similar in both periods. However, the majority of mean monthly air temperatures in historical times still lie within two standard deviations (SDs) from the modern mean. Marine data show good correspondence with land data. The May–September average air temperature for the period 1871–1910 was slightly lower in the seas surrounding Svalbard (by 0.4 °C) than today. About 90% of these mean air temperatures lie within the range of ±3SDs from the ERA-Interim present-day mean. Seasonal patterns of air temperature changes in the Svalbard archipelago between historical and standard normal (1961–1990) periods show generally very good correspondence to similar changes, not only for the Atlantic region, but also for some other Arctic regions (e.g. SE Greenland, Canadian Arctic, Barents and Kara seas), as well as for the entire Arctic. All available reconstructions of annual air temperature using isolated series of early instrumental observations reveal that in historical times, air temperatures were colder than the standard normal (1961–1990) by about 0.5–1.0 °C. Compared with the new normal period (1981–2010), those differences rise to about 1.5–2.5 °C.

Meteorology & Atmospheric Sciences↗

Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters

This study explores the potential environmental and energy benefits of using activated carbon fiber (ACF) filters for air cleaning in HVAC systems. The parallel aims for the air cleaning system were to enable reduced indoor exposures to volatile organic compounds (VOCs) and to simultaneously allow reduced rates and energy consumption for outdoor-air ventilation. We evaluated the use of ACF media to adsorb VOCs from indoor air during repeated simulated 12-hour to 24-hour periods of occupancy. In a cyclic regeneration process, VOCs were desorbed from the ACF media and vented outdoors to enable the next cycle of air cleaning. The VOC removal efficiency of the ACF media was measured using a 9.5-cm 2 ACF specimen exposed to a mixture of VOCs that included toluene, benzene, o-xylene, 1-butanol, limonene, undecane and formaldehyde at 29 °C and 30 percent relative humidity. The concentrations of these model pollutants upstream of the ACF media were in the range 20 to 30 ppb, to simulate realistic conditions. Velocities through the ACF media were typical of those in normal particle filter systems (~ 0.5 m s -1 ). Initial tests were conducted to develop a modified multi-component Freundlich isotherm and estimate the maximum adsorption capacity of the media, which was determined to be 90 mg VOC per gram of ACF. Three different ACF regeneration methods were explored using relatively cleaner outdoor air under ambient conditions, with this air humidified, and with the filter heated. It was found that heating the ACF media to ~150 °C by circulation of a DC current through the fibers for a short period (15 minutes) yielded the best VOC removal results, allowing for subsequent consistent removal efficiencies of 70-80 percent for most VOCs. Regeneration with unheated outdoor air was also effective and used less energy (subsequent removal efficiency was 50-60 percent for most VOCs). ACF did not perform as well in eliminating formaldehyde, for which a maximum removal of 25-30 percent was achieved with heated regeneration. A mass balance model indicated that the combination of ACF air cleaning and a 50percent reduction in ventilation will decrease indoor concentrations of VOCs by 60 percent to 80 percent and reduce formaldehyde concentrations by 12 percent to 40 percent. Energy modeling indicated the potential to reduce the energy required for heating and cooling of ventilation air by 35 percent to almost 50 percent.

54 ENVIRONMENTAL SCIENCES↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

A multi-model assessment of the co-benefits of climate mitigation for global air quality

The recent International Panel on Climate change (IPCC) report identifies significant co-benefits from climate policies on near-term ambient air pollution and related human health outcomes [1]. This is increasingly relevant for policy making as the health impacts of air pollution are a major global concern- the Global Burden of Disease (GBD) study identifies outdoor air pollution as the sixth major cause of death globally [2]. Integrated assessment models (IAMs) are an effective tool to evaluate future air pollution outcomes across a wide range of assumptions on socio-economic development and policy regimes. The Representative Concentration Pathways (RCPs) [3] were the first set of long-term global scenarios developed across multiple integrated assessment models that provided detailed estimates of a number of air pollutants until 2100. However these scenarios were primarily designed to cover a defined range of radiative forcing outcomes and thus did not specifically focus on the interactions of long-term climate goals on near-term air pollution impacts. More recently, [4] used the RCP4.5 scenario to evaluate the co-benefits of global GHG reductions on air quality and human health in 2030. [5-7] have further examined the interactions of more diverse pollution control regimes with climate policies. This paper extends the listed studies in a number of ways. Firstly it uses multiple IAMs to look into the co-benefits of a global climate policy for ambient air pollution under harmonized assumptions on near-term air pollution control. Multi-model frameworks have been extensively used in the analysis of climate change mitigation pathways, and the structural uncertainties regarding the underlying mechanisms (see for example [8-10]. This is to our knowledge the first time that a multi-model evaluation has been specifically designed and applied to analyze the co-benefits of climate change policy on ambient air quality, thus enabling a better understanding of at a detailed sector and region level. A second methodological advancement is a quantification of the co-benefits in terms of the associated atmospheric concentrations of fine particulate matter (PM2.5) and consequent mortality related outcomes across different models. This is made possible by the use of state-of the art simplified atmospheric model that allows for the first time a computationally feasible multi-model evaluation of such outcomes.

Rao, Shilpa↗

SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

60 APPLIED LIFE SCIENCES↗

Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems

Terminal boxes usually serve a single building zone, controlling the air-flow rate to the zone and reheating the air when it is too cool. Each terminal box has a minimum air-flow rate that ensures the ventilation requirements of the occupants of the zone served are met. This minimum air-flow rate is maintained at a constant value based on the design occupancy of the zone, which often corresponds to the maximum occupancy, because measurements of actual occupancy are not currently used to adjust the flow rate. Therefore, the minimum flow rate must meet the ventilation needs of the fully occupied zone. The total flow rate may be higher than the minimum to provide adequate cooling or heating, but the minimum for ventilation should always be met. In practice, control system integrators and installers often set the cooling minimum air-flow rate for ventilation to between 30% and 50% of the maximum air-flow rate of the terminal box. Building occupancy, however, varies dynamically. Conference rooms, cafeterias, auditoriums, and other assembly spaces are often unoccupied for significant periods of time. Office occupancy varies during the course of a work day, from day to day, and over the longer term because of attendance of meetings elsewhere, business travel, changing room functions, and variations in staffing. The resulting over-ventilation, during times when the space has less than maximum occupancy or is unoccupied, wastes significant fan energy and causes discomfort for occupants in some spaces (e.g., conference rooms) from overcooling or overheating, especially in interior zones that do not have reheat in the terminal boxes. Common occupancy sensors, which measure whether occupants are present or not, are commonly used for lighting control in conference rooms and other spaces with variable occupancy. They could be used to enable a terminal box to be switched to an occupied standby mode in which the air-flow rate is set to zero when no occupants are in the zone the box serves. If advanced occupancy sensors, which count the actual number of occupants in a room, were used to control terminal boxes, the minimum air-flow rate set point for the terminal box could be reset dynamically based on the actual occupancy sensed. This study evaluates the savings potential from use of occupancy-based control (OBC) of terminal boxes for large office buildings with variable-air-volume (VAV) heating, ventilating and air-conditioning (HVAC) systems using both common occupancy sensors and advanced occupancy sensors.

Zhang, Jian↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air-to-Fuel Ratio Calculation Methods for Oxygenated Fuels in Two-Stroke Engines

In 1990, Roy Douglas developed an analytical method to calculate the global air-to-fuel ratio of a two-stroke engine from exhaust gas emissions. While this method has considerable application to two-stroke engines, it does not permit the calculation of air-to-fuel ratios for oxygenated fuels. This study proposed modifications to the Roy Douglas method such that it can be applied to oxygenated fuels. The ISO #16183 standard, the modified Spindt method, and the Brettschneider method were used to evaluate the modifications to the Roy Douglas method. In addition, a trapped air-to-fuel ratio, appropriate for two-stroke engines, was also modified to incorporate oxygenated fuels. To validate the modified calculation method, tests were performed using a two-stroke carbureted and two-stroke direct injected marine outboard engine over a five-mode marine test cycle running indolene and low level blends of ethanol and iso-butanol fuels. Results indicate that the modified air-fuel ratio method closely relates to the ISO #16183 standard. The modified Spindt method over-estimated the global air-to-fuel ratio. While the Brettschneider is considered an advancement over the Spindt method, it still provided an over-estimate of the air-to-fuel ratio. Applying a trapped air-to-fuel ratio calculation to the modified Roy Douglas method provided a calculation for trapped air-to-fuel ratio for two-stroke engine operation, which correlated with engine-out CO emissions. The trapped air-to-fuel ratio calculation also provided improvements in air-to-fuel ratio predictions, especially during idle conditions.

Sevik, James Michael↗

Atmospheric H 2 observations from the NOAA Cooperative Global Air Sampling Network

Abstract. The NOAA Global Monitoring Laboratory (GML) measures atmospheric hydrogen (H2) in grab samples collected weekly as flask pairs at over 50 sites in the Cooperative Global Air Sampling Network. Measurements representative of background air sampling show higher H2 in recent years at all latitudes. The marine boundary layer (MBL) global mean H2 was 552.8 ppb in 2021, 20.2 ± 0.2 ppb higher compared to 2010. A 10 ppb or more increase over the 2010–2021 average annual cycle was detected in 2016 for MBL zonal means in the tropics and in the Southern Hemisphere. Carbon monoxide measurements in the same-air samples suggest large biomass burning events in different regions likely contributed to the observed interannual variability at different latitudes. The NOAA H2 measurements from 2009 to 2021 are now based on the World Meteorological Organization Global Atmospheric Watch (WMO GAW) H2 mole fraction calibration scale, developed and maintained by the Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany. GML maintains eight H2 primary calibration standards to propagate the WMO scale. These are gravimetric hydrogen-in-air mixtures in electropolished stainless steel cylinders (Essex Industries, St. Louis, MO), which are stable for H2. These mixtures were calibrated at the MPI-BGC, the WMO Central Calibration Laboratory (CCL) for H2, in late 2020 and span the range 250–700 ppb. We have used the CCL assignments to propagate the WMO H2 calibration scale to NOAA air measurements performed using gas chromatography and helium pulse discharge detector instruments since 2009. To propagate the scale, NOAA uses a hierarchy of secondary and tertiary standards, which consist of high-pressure whole-air mixtures in aluminum cylinders, calibrated against the primary and secondary standards, respectively. Hydrogen at the parts per billion level has a tendency to increase in aluminum cylinders over time. We fit the calibration histories of these standards with zero-, first-, or second-order polynomial functions of time and use the time-dependent mole fraction assignments on the WMO scale to reprocess all tank air and flask air H2 measurement records. The robustness of the scale propagation over multiple years is evaluated with the regular analysis of target air cylinders and with long-term same-air measurement comparison efforts with WMO GAW partner laboratories. Long-term calibrated, globally distributed, and freely accessible measurements of H2 and other gases and isotopes continue to be essential to track and interpret regional and global changes in the atmosphere composition. The adoption of the WMO H2 calibration scale and subsequent reprocessing of NOAA atmospheric data constitute a significant improvement in the NOAA H2 measurement records.

Pétron, Gabrielle↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

Deyo, J.↗

Performance and emission characteristics of swirl-can combustors to near-stoichiometric fuel-air ratio

Emissions and performance characteristics were determined for two full annular swirl-can combustors operated to near stoichiometric fuel-air ratio. Test condition variations were as follows: combustor inlet-air temperatures, 589, 756, 839, and 894 K; reference velocities, 24 to 37 meters per second; inlet pressure, 62 newtons per square centimeter; and fuel-air ratios, 0.015 to 0.065. The combustor average exit temperature and combustor efficiency were calculated from the combustor exhaust gas composition. For fuel-air ratios greater than 0.04, the combustion efficiency decreased with increasing fuel-air ratios in a near-linear manner. Increasing the combustor inlet air temperature tended to offset this decrease. Maximum oxides of nitrogen emission indices occurred at intermediate fuel-air ratios and were dependent on combustor design. Carbon monoxide levels were extremely high and were the primary cause of poor combustion efficiency at the higher fuel-air ratios. Unburned hydrocarbons were low for all test conditions. For high fuel-air ratios SAE smoke numbers greater than 25 were produced, except at the highest inlet-air temperatures.

Diehl, L. A.↗

Investigation of Aerodynamic and Icing Characteristics of a Flush Alternate Inlet Induction System Air Scoop

An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.

Lewis, James P.↗