Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of damage and ablation dynamics of multilayer dielectric films initiated by few-cycle pulses versus longer femtosecond pulses

The importance of high intensity few- to single-cycle laser pulses for applications such as intense isolated attosecond pulse generation is constantly growing, and with the breakdown of the monochromatic approximation in field ionization models, the few-cycle pulse (FCP) interaction with solids near the damage threshold has ushered a new paradigm of nonperturbative light–matter interaction. In this Letter, we systematically study and contrast how femtosecond laser-induced damage and ablation behaviors of SiO 2 /HfO 2 -based reflective multilayer dielectric thin film systems vary between FCP and 110 fs pulses. With time-resolved surface microscopy and ex situ analysis, we show that there are distinct differences in the interaction depending on the pulse duration, specifically in the “blister” morphology formation at lower fluences (damage) as well as in the dynamics of debris formation at higher fluences (ablation).

42 ENGINEERING↗

Evaluation of the RADCHEM Diagnostic as an Assessment of Fuel-Ablator Mix and Fuel Rho R

The RADCHEM diagnostic consists of the collection of both gaseous and solid debris samples following a NIF shot. Small amounts of detector elements are doped into the inner-most layer of the ablator shell, which then undergo nuclear activations with neutrons and/or charged particles that are produced during the fusion process. Reaction products are collected and their radioactive decays are counted in order to determine the number and type of activations that occurred. Simulations have shown that these data can then be correlated to several capsule parameters, including fuel rhoR ({rho}R), implosion asymmetry, and fuel-ablator mix. In this document we present a brief summary of the simulations that have been performed, and evalute the ability of RADCHEM to assess capsule performance. A longer, follow-on document, which will include more details on the specific simulations and experimental techniques that have been considered for RADCHEM, is currently being written.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laser Ablation, Absorbance Ratio Spectrometry (LAARS) Assay Performance Study (FY2018 Annual Report)

The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. Pacific Northwest National Laboratory (PNNL) is developing one such tool, called the Laser Ablation, Absorbance Ratio Spectrometry (LAARS) technology, which is designed to provide high-fidelity 235 U/ 238 U isotope ratio measurements to support either on-site enrichment plant or off-site laboratory destructive assay (DA). Analyzing uranium hexafluoride (UF 6 ) DA samples on-site by LAARS could provide early indication of discrepancies with operator declarations during physical inventory verifications, so that such discrepancies could be addressed immediately, rather than after off-site analysis is completed. The IAEA is also seeking on-site DA options, because sample shipping time can be long and evolving restrictions on radioactive/corrosive material shipments may increasingly limit the IAEA’s ability to easily transport UF 6 samples. Routine on-site LAARS analysis could provide timely assay results and reduce the DA sample shipment inventory to just those needed for more definitive determination. A laboratory-based LAARS instrument could also provide rapid, cost-effective prescreening of selected DA samples shipped to the IAEA’s Nuclear Materials Laboratory in Seibersdorf, Austria. PNNL has also developed a complementary UF 6 sampling technology and method, called the Single-Use Destructive Assay (SUDA) sampler to easily collect DA samples that are ideal for on-site analysis by LAARS. Combining the LAARS and SUDA sampler technologies could provide a powerful new on-site DA option for the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryo-Ablation Experiments for Omega in FY23 [Slides]

Future HED & Nuclear Survivability platforms will use macroscopic 2PP lattice materials for inter-shell support and as a host for higher-yield DT wetted-lattice ablator targets. Average EOS and shock spatial non-uniformity measurements are needed as a function of lattice properties. The FY23 goal is to understand ablative & shock characteristics of heterogeneous D 2 - filled lattice materials at low drive intensities (~250TW/cm 2 ) in planar geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser Ablation for Low-Cost Multijunction III-V Solar Cell Mesa Isolations

Eliminating photolithography from solar cell processing is a significant opportunity for cost reduction for III-V solar cells. In this work, we test femtosecond laser ablation and scribing as an alternative to contact photolithography and wet chemical etching for mesa isolation, when processing multijunction cells. We demonstrate that upright multijunction solar cells isolated by using the laser as a scribe to cleave through the substrate had virtually no performance loss when compared to a baseline cell processed with photolithography. By contrast, cells isolated by laser ablating through the active layers have performance losses that cannot be fully eliminated with post-processing etches. This demonstration of photolithography-free mesa isolation with no performance losses is promising for less expensive III-V manufacturing.

14 SOLAR ENERGY↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of the 176 Yb Interference Correction during Determination of the 176 Hf/ 177 Hf Ratio by Laser Ablation and Solution Analysis on the Neoma MC-ICP-MS

We utilized the Neoma™, a recently released MC-ICP-MS platform offered by ThermoFisher Scientific, to assess the behavior of the Lu-Yb-Hf system during laser ablation analyses of various zircon standards as well as solution-based analyses of the JMC-475 Hf standard doped with varying quantities of Yb and Lu. The primary goal of this work was to characterize the behavior of the Yb interference correction on the Neoma™ platform since this is one of the biggest issues in the Hf isotope analysis community and because the Neoma™ platform will supplant the Neptune™ series instrument. During laser ablation analysis, we found that the overall data quality scales proportionally with the total Hf signal intensity, with higher signal analyses producing extremely accurate (within 1 ε Hf unit) and precise (sub ε Hf unit within-run standard errors) data. At low Yb signals (<0.1 V 173 Yb), we were not able to produce an accurate internal Yb mass bias factor. However, utilizing an empirical approach allows for the application of session-specific relationships between the Yb and Hf mass bias factors, determined by analysis of standards of varying Yb content, to produce accurate ε Hf values from zircons with higher Yb/Hf ratios even where the total Hf signal intensity is relatively low. Similar behavior was observed in the solution analyses. Lastly, while the behavior of the Yb interference correction on the Neoma™ platform appears comparable to the Neptune™ series MC-ICP-MS, further work will help refine the understanding of the controls on mass bias behavior, oxide formation, session-to-session stability, etc.

36 MATERIALS SCIENCE↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Modelling and Experimental Validation of Improved Performance of Lithium-Ion Batteries Having Thick Electrodes with Laser-Ablated Micro-Structures

For widespread adoption of electric vehicles, lithium-ion batteries (LiBs) need to achieve energy densities of >275 Wh/kg, cost less than $100/Wh, and charge to more than 80% capacity within 15 minutes. Increasing the battery electrode thicknesses is one way to increase cell energy densities while also saving on cell manufacturing cost by increasing the ratio of electrode active material to inactive material within each cell. However, increased electrode loading is often accompanied by decreased Li+-ion diffusion across the full thick electrodes. This leads to significant cell polarization that prevents full capacity utilization and accelerates cell degradation, especially at fast charging/discharging rates. The introduction of secondary pore networks in thick battery electrodes alleviates some of the trade-offs between energy and power performance. These microstructures provide low tortuosity pathways for facile Li+-ion diffusion deep into the thick electrodes, diminishing detrimental concentration gradients within the cell. Ultrafast-pulsed laser ablation is a promising method to introduce micro pores or channels in thick battery electrodes as it allows for precise control of pattern geometries, results in minimal damage to the electrode and can be introduced into existing roll-to-roll electrode manufacturing lines. Herein, the limitations of thick planer electrodes and the advanced predictive models to identify optimal electrode patterns for improved cycling performance will be presented. The impact of electrode laser patterning to create secondary pore networks also will be discussed. Materials characterization techniques (SEM-EDS, XRD) were used to explore the affect ultrafast laser ablation had on the electrode materials’ morphology and structure. The improvements in the patterned electrodes’ electrochemical cycling performances and degrees of wetting will be compared to a pristine baseline case. Finally, the discrepancies between experimentally obtained data and model predictions will be explained.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗

Laser Ablation of Dental Calculus Around 400 nm Using a Ti:Sapphire Laser

A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides ≤25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences ≥2 J/cm^2; stalling occurs below this fluence because of photobleaching. Healthy hard tissue is not removed at fluences ≤3 J/cm^2.

calculus removal↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated laser ablation-dropletProbe-mass spectrometry for absolute drug quantitation, metabolite detection, and distribution in tissue

Rationale: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. In this work, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 μm thin tissue samples. Methods: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. Results: Absolute propranolol concentration in ~500 × 500 μm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 μm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. Conclusions: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.

47 OTHER INSTRUMENTATION↗

Adjunctive Thermoprotection During Percutaneous Thermal Ablation Procedures: Review of Current Techniques

Although rare, unintended thermal injury to organs surrounding the ablation zone can lead to severe complications. Over the past 15 years, different protective methods have been developed to limit risk of complications, and expand indications to include more challenging lesions in various locations including liver, kidney, lung and bone. The most frequently used techniques include hydrodissection, carbodissection, balloon interposition and probe torqueing. In most cases, tumours can be physically separated from sensitive structures, reducing risk of thermal injury. Endoluminal cooling/warming is an alternative option for complex ablations close to the ureter or major bile ducts. Different techniques may be combined to achieve successful protection in locations with complex anatomy. The purpose of this review is to provide an overview of available protective measures and discuss respective advantages/drawbacks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation synthesis of silver nanoparticles in water and dependence on laser nature

Silver nanoparticles have been synthesized by a one step, easy, fast and green method. The nanoparticles were prepared in de-ionized water by laser ablation method using two lasers, a continuous wave (CW) diode laser and a pulsed Nd:YAG laser. The purpose of the experiment is to compare the role of nature of the laser for production of better NPs. The prepared silver nanoparticles were characterized for their, structural, physical and optical properties. The structural properties of the synthesized nanoparticles were characterized by X-ray Diffraction and the nanoparticles were found to be crystalline. The physical properties were analyzed by Atomic Force Microscopy which confirmed spherical and nanometer sized nanoparticles. The average size was 20 nm and 9 nm for continuous and pulsed laser respectively. The optical properties were analyzed by UV–Visible spectroscopy where band gap energy was investigated and increase in band gap energy as compared to bulk was observed. The green nature of laser ablation method, surface chemistry and chemical contamination of the surface of prepared nanoparticles were analyzed by Fourier Transform Infrared Spectroscopy. The thermal conductivity of the nanoparticles colloidal solutions (nanofluids) was calculated and an enhancement of 16% and 27% was observed for CW and pulsed laser prepared nanofluids respectively as compared to base liquid (de-ionized water).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING↗

Stereotactic Ablative Body Radiation Therapy for Octogenarians With Non-Small Cell Lung Cancer

Purpose: To retrospectively investigate treatment outcomes of stereotactic ablative body radiation therapy (SABR) for octogenarians with non-small cell lung cancer (NSCLC). Methods and Materials: Between 2005 and 2012, 109 patients aged ≥80 years with T1-2N0M0 NSCLC were treated with SABR: 47 patients had histology-unproven lung cancer; 62 patients had pathologically proven NSCLC. The prescribed doses were either 50 Gy/5 fractions for peripheral tumors or 40 Gy/5 fractions for centrally located tumors. The treatment outcomes, toxicities, and the correlating factors for overall survival (OS) were evaluated. Results: The median follow-up duration after SABR was 24.2 (range, 3.0-64.6) months. Only limited toxicities were observed, except for 1 grade 5 radiation pneumonitis. The 3-year local, regional, and distant metastasis-free survival rates were 82.3%, 90.1%, and 76.8%, respectively. The OS and lung cancer-specific survival rates were 53.7% and 70.8%, respectively. Multivariate analysis revealed that medically inoperable, low body mass index, high T stage, and high C-reactive protein were the predictors for short OS. The OS for the operable octogenarians was significantly better than that for inoperable (P<.01). Conclusions: Stereotactic ablative body radiation therapy for octogenarians was feasible, with excellent OS. Multivariate analysis revealed that operability was one of the predictors for OS. For medically operable octogenarians with early-stage NSCLC, SABR should be prospectively compared with resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗