At least 595 records · Page 33

Exploring Lightning and Convective Processes Using the Ground-Radar Multiplatform Precipitation Feature Database

The Multiplatform Precipitation Feature (MPF) database synthesizes coincident spaceborne and ground-based lightning and radar data in a framework of storm-based features, fusing broader spaceborne detection capabilities with process-based, storm-level analysis practices. The MPF database was designed to extend the scale and scope of investigations into the complex connections between precipitation, updrafts, and lightning. The NASA International Space Station Lightning Imaging Sensor (ISS LIS) serves as the source of lightning information for the database. The first iteration of the MPF database leveraged the NASA Global Precipitation Measurement (GPM) mission spaceborne Dual-frequency Precipitation Radar (DPR) to define features, along with contributions of microphysics data and vertical wind retrievals from the GPM Validation Network (VN) of ground-based radar data. The dependency on coincident ISS and GPM satellite overpasses of radars in a dual-Doppler configuration significantly limited the size of the initial database of features, referred to as VNMPFs, but established the database infrastructure and feasibility. We present here a second iteration of the MPF database that omits the GPM DPR and VN, instead incorporating data directly from selected proximal installations of the operational Next Generation Radar (NEXRAD) network that facilitate vertical wind retrievals via dual-Doppler analysis. These features based exclusively on ground-based polarimetric Doppler radar are hereafter referred to as Ground-Radar MPFs (GRMPFs). Removing the restriction of a coincident GPM overpass appreciably increases the size of the GRMPF database while incorporating more detailed information from higher-resolution radar data and retrievals. This expansion allows for unprecedented broad, robust statistical analyses of the electrical, kinematic, and microphysical characteristics of deep convective processes. These results highlight the potential for advancements in lightning meteorology made possible by combining multiple perspectives from global lightning measurements and ground-based radar data.

Lightning↗

Coherent Doppler Laser Radar: Technology Development and Applications

NASA's Marshall Space Flight Center has been investigating, developing, and applying coherent Doppler laser radar technology for over 30 years. These efforts have included the first wind measurement in 1967, the first airborne flights in 1972, the first airborne wind field mapping in 1981, and the first measurement of hurricane eyewall winds in 1998. A parallel effort at MSFC since 1982 has been the study, modeling and technology development for a space-based global wind measurement system. These endeavors to date have resulted in compact, robust, eyesafe lidars at 2 micron wavelength based on solid-state laser technology; in a factor of 6 volume reduction in near diffraction limited, space-qualifiable telescopes; in sophisticated airborne scanners with full platform motion subtraction; in local oscillator lasers capable of rapid tuning of 25 GHz for removal of relative laser radar to target velocities over a 25 km/s range; in performance prediction theory and simulations that have been validated experimentally; and in extensive field campaign experience. We have also begun efforts to dramatically improve the fundamental photon efficiency of the laser radar, to demonstrate advanced lower mass laser radar telescopes and scanners; to develop laser and laser radar system alignment maintenance technologies; and to greatly improve the electrical efficiency, cooling technique, and robustness of the pulsed laser. This coherent Doppler laser radar technology is suitable for high resolution, high accuracy wind mapping; for aerosol and cloud measurement; for Differential Absorption Lidar (DIAL) measurements of atmospheric and trace gases; for hard target range and velocity measurement; and for hard target vibration spectra measurement. It is also suitable for a number of aircraft operations applications such as clear air turbulence (CAT) detection; dangerous wind shear (microburst) detection; airspeed, angle of attack, and sideslip measurement; and fuel savings through headwind minimization. In addition to the airborne and space platforms, a coherent Doppler laser radar system in an unmanned aerial vehicle (UAV) could provide battlefield weather and target identification.

Kavaya, Michael J.↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% — for the highest temperature in the slot windings and the end windings — was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

47 OTHER INSTRUMENTATION↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor: Preprint

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot windings and the end windings - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

ADVANCED PROPULSION SYSTEMS↗

Chapter 14 - Reliability of Wind Turbines

The global wind energy industry has grown at a fast pace during the past half-decade. Advancements from design and manufacturing to operation and maintenance have led to reduced capital and maintenance costs, which make wind power an indispensable source for a comprehensive solution to global electricity needs. Once wind turbines are installed, the opportunity to lower wind power costs is mainly through improved operation and maintenance practices. Modern wind turbines are equipped with tens or hundreds of measurement channels and are generating an abundance of data, with lot of efforts being put into data analysis by both the research community and the industry. One type of analysis is through the exploration of reliability engineering methods based on readily available data or maintenance records collected at typical wind power plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. The wind industry has adopted this discipline more broadly in recent years. This chapter discusses wind turbine reliability by highlighting the methodology of reliability engineering life data analysis. It first briefly discusses the fundamentals of wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.

database↗

A Pumped Thermal Energy Storage Cycle with Capacity for Concentrated Solar Power Integration

Pumped thermal energy storage (PTES) is a grid-scale energy management technology that stores electricity in the form of thermal energy. A number of PTES systems have been proposed using different thermodynamic cycles, including a variant based on a regenerated Brayton cycle that stores the thermal energy in liquid storage media (such as molten salts) via heat exchangers. This has several advantages, including the possibility to consider hybrid 'solar-PTES' systems employing technology developed by the concentrated solar power (CSP) industry. Such a hybrid system could charge the same hot stores using either solar energy or off-peak electricity (e.g, from nearby wind farms), increasing the capacity factor of the plant while employing the same heat engine during discharge. In this paper, two different configurations of solar-PTES systems are proposed and studied numerically: (i) a configuration in which an existing CSP plant is retrofitted with a Brayton heat pump, and (ii) a configuration in which a new hybrid plant uses the Brayton cycle both for charge and discharge. In both cases, the need to absorb and reject heat at conditions close to ambient temperature requires the Brayton cycle to incorporate intercooled stages at the cold side of the cycle. On the other hand, the intercooling process increases the minimum temperature of the cold stores, meaning that widely available and nonflammable antifreeze solutions (such as water-ethylene glycol) may be used as the cold storage medium.

14 SOLAR ENERGY↗

Coordinated Control Strategy of a Battery Energy Storage System to Support a Wind Power Plant Providing Multi-Timescale Frequency Ancillary Services

With increasing penetrations of wind generation on electric grids, wind power plants (WPPs) are encouraged to provide frequency ancillary services (FAS); however, it is a challenge to ensure that variable wind generation can reliably provide these ancillary services. This paper proposes using a battery energy storage system (BESS) to ensure the WPPs' commitment to FAS. This method also focuses on reducing the BESS's size and extending its lifetime. In this paper, a state-machine-based coordinated control strategy is developed to utilize a BESS to support the obliged FAS of a WPP (including both primary and secondary frequency control). This method takes into account the operational constraints of the WPP (e.g., real-time reserve) and the BESS (e.g., state of charge [SOC], charge and discharge rate) to provide reliable FAS. Meanwhile, an adaptive SOC-feedback control is designed to maintain SOC at the optimal value as much as possible and thus reduce the size and extend the lifetime of the BESS. In conclusion, the effectiveness of the control strategy is validated with an innovative, multi-area, interconnected power system simulation platform that can mimic realistic power systems operation and control by simulating real-time economic dispatch, regulating reserve scheduling, multi-area automatic generation control, and generators' dynamic response.

25 ENERGY STORAGE↗

Hydrogen Production Cost with Alkaline Electrolysis

Rigorous stakeholder-vetted techno-economic analysis was performed to assess the cost of hydrogen (H 2 ) produced using state-of-the-art Liquid Alkaline (LA) electrolysis. Projected high-volume, untaxed levelized cost of hydrogen (LCOH) range from 2020US $\$ 1.84$ to $\$ 2.88$/kg-H 2 depending on technology year, process design, and electrolyzer project scale, assuming an electricity price of $\$ 0.03$/kWh. The total installed capital cost for a LA electrolysis plant was estimated from bottom-up stack and installed cost models that account for purchased equipment, installation costs, site preparation, and general overhead costs. For this study, the LA electrolysis plant is assumed to be a stick-built, greenfield project developed by an EPC firm with electrolysis stacks purchased directly from an electrolysis stack manufacturer. The price of the electrolysis stacks is based on a bottom-up cost assessment with business markup for the electrolysis company fabricator. Methods from the Hydrogen Analysis (H 2 A) production model, a peer-reviewed national laboratory-developed discounted cash flow model, were used to calculate the LCOH production in 2020$/kg-H 2 . The baseline electricity price case ($\$ 0.03$/kWh) corresponds to average wholesale electricity prices currently possible in U.S. markets with plentiful wind. Similar low-cost electricity pricing is possible from solar Power Purchase Agreements (PPA) although these prices are typically limited by renewable energy capacity factors.

08 HYDROGEN↗

Hydrogen Production Cost with Anion Exchange Membrane Electrolysis

Rigorous stakeholder-vetted techno-economic analysis was performed to assess the cost of hydrogen (H 2 ) produced using state-of-the-art Anion Exchange Membrane (AEM) electrolysis. Projected high-volume, untaxed and unsubsidized levelized cost of hydrogen (LCOH)1 range from 2020 $\$$1.78 to $\$$3.68/kg H 2 depending on technology year, process design, and electrolyzer project scale, assuming an electricity price of $\$$0.03/kWh and a capacity factor of 97%. The total installed capital cost for an AEM electrolysis plant was estimated from bottom-up stack and process plant cost models. The stack cost model accounts for manufacturing equipment, equipment maintenance, material, tooling, cycle time, yield, labor, utilities and general overhead. The process plant cost model accounts for purchased equipment, installation costs, site preparation, and general overhead costs. For this study, the AEM electrolysis plant is assumed to be a stick-built, greenfield project developed by an engineering, procurement, and construction (EPC) firm with electrolysis stacks purchased directly from an electrolysis stack manufacturer. The price of the electrolysis stacks is based on a bottom-up cost assessment with business markup for the electrolysis company fabricator. Methods from the Hydrogen Analysis (H2A) production model, a peer-reviewed national laboratory-developed discounted cash flow (DCF) model, were used to calculate the production LCOH in 2020 $\$$/kg H 2 . The baseline electricity price case ($\$$0.03/kWh) corresponds to average wholesale electricity prices currently possible in U.S. markets with plentiful wind. Similar low-cost electricity pricing is possible from solar Power Purchase Agreements (PPA) although these prices are typically limited by renewable energy capacity factors.

08 HYDROGEN↗

Ionospheric Storm Effects and Equatorial Plasma Irregularities During the 17-18 March 2015 Event

The intense magnetic storm on 17-18 March 2015 caused large disturbances of the ionosphere. Based on the plasma density (Ni) observations performed by the Swarm fleet of satellites, the Gravity Recovery and Climate Experiment mission, and the Communications/Navigation Outage Forecasting System satellite, we characterize the storm-related perturbations at low latitudes. All these satellites sampled the ionosphere in morning and evening time sectors where large modifications occurred. Modifications of plasma density are closely related to changes of the solar wind merging electric field (E (sub m)). We consider two mechanisms, prompt penetration electric field (PPEF) and disturbance dynamo electric field (DDEF), as the main cause for the Ni redistribution, but effects of meridional wind are also taken into account. At the start of the storm main phase, the PPEF is enhancing plasma density on the dayside and reducing it on the nightside. Later, DDEF takes over and causes the opposite reaction. Unexpectedly, there appears during the recovery phase a strong density enhancement in the morning/pre-noon sector and a severe Ni reduction in the afternoon/evening sector, and we suggest a combined effect of vertical plasma drift, and meridional wind is responsible for these ionospheric storm effects. Different from earlier studies about this storm, we also investigate the influence of storm dynamics on the initiation of equatorial plasma irregularities (EPIs). Shortly after the start of the storm main phase, EPIs appear in the post-sunset sector. As a response to a short-lived decline of E (sub m), EPI activity appears in the early morning sector. Following the second start of the main phase, EPIs are generated for a few hours in the late evening sector. However, for the rest of the storm main phase, no more EPIs are initiated for more than 12 hours. Only after the onset of recovery phase does EPI activity start again in the post-midnight sector, lasting more than 7 hours.This comprehensive view of ionospheric storm effects and plasma irregularities adds to our understanding of conditions that lead to ionospheric instabilities.

Zhou, Yun-Liang↗

Power Rover

The Power Rover project is a North Dakota State University (NDSU) undergraduate investigation into the design of a rover that would generate, store, and deliver power to other rovers and equipment on the surface of Mars funded through the NASA X-Hab challenge. X-Hab is a portion of NASA that challenges students to act as a new set of eyes and design engineered solutions that address critical needs of the Artemis program. The goal of this specific project was to design, build, and test an Earth-based prototype of a Martian rover called the Power Rover. The Power Rover is a solar, nuclear, and wind powered tele-operated rover that can generate, store, and deliver power to other rovers or equipment on the Martian surface that are in critical power situations. Due to the large complexity of the project, it was assigned to three senior design groups within the NDSU Mechanical Engineering and Electrical Engineering departments. These groups include an electrical team, power generation and storage team, and structure and drivetrain team. This report will detail the information, findings, final design solutions, and testing that have been made by the NDSU teams during the fall and spring semesters of the 2021-2022 academic school year.

Alex Johnson↗

Alfvén wave propagation through a moderate-amplitude transverse inhomogeneity in a magnetized plasma

Parallel propagation of a plane Alfvén wave in a moderate-amplitude Gaussian-shaped transverse inhomogeneity is studied numerically using a fluid model retaining low-frequency kinetic effects. It is shown that in such a situation, common in the solar wind where elongated pressure-balanced structures are frequently observed, phase mixing competes with wave focusing, in contrast with coronal loops or auroral regions where sharp gradients present at the edges of the inhomogeneities make phase mixing dominant. Some understanding about this competition is provided by a model based on an envelope formalism. Depending on the magnitude of the Alfvén wavelength and of the inhomogeneity transverse scale relative to the ion inertial length, various regimes can develop, ranging from the formation of localized gradients when phase mixing dominates to the development of an intense magnetic filament when focusing is stronger, with a different efficiency for the generation of magnetosonic and kinetic Alfvén waves. Electron parallel heating and parallel electric field generation are also briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of increasing tip velocity on wind turbine rotor design.

A reduction in cost of energy from wind is anticipated when maximum allowable tip velocity is allowed to increase. Rotor torque decreases as tip velocity increases and rotor size and power rating are held constant. Reduction in rotor torque yields a lighter weight gearbox, a decrease in the turbine cost, and an increase in the capacity for the turbine to deliver cost competitive electricity. The high speed rotor incurs costs attributable to rotor aero-acoustics and system loads. The increased loads of high speed rotors drive the sizing and cost of other components in the system. Rotor, drivetrain, and tower designs at 80 m/s maximum tip velocity and 100 m/s maximum tip velocity are created to quantify these effects. Component costs, annualized energy production, and cost of energy are computed for each design to quantify the change in overall cost of energy resulting from the increase in turbine tip velocity. High fidelity physics based models rather than cost and scaling models are used to perform the work. Results provide a quantitative assessment of anticipated costs and benefits for high speed rotors. Finally, important lessons regarding full system optimization of wind turbines are documented.

17 WIND ENERGY↗

Impact of Generator Flexibility on Electric System Costs and Integration of Renewable Energy

Flexibility of traditional generators plays an important role in accommodating the increased variability and uncertainty of wind and solar on the electric power system. Increased flexibility can be achieved with changes to operational practices or upgrades to existing generation. One challenge is in understanding the value of increasing flexibility, and how this value may change given higher levels of variable generation. This study uses a commercial production cost model to measure the impact of generator flexibility on the integration of wind and solar generators. We use a system that is based on two balancing areas in the western United States with a range of wind and solar penetrations between 15% and 60%, where instantaneous penetration of wind and solar is limited to 80%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative magnetospheric/ionospheric studies using Dynamics Explorer spacecraft and ground-based radars

Coincident observations between the Dynamics Explorer 1 and 2 spacecraft with Chatanika and Arecibo ground-based radar are briefly reviewed. Ionospheric-magnetospheric coupling processes in the plasmasphere, main trough, auroral zone, and polar cap are inferred from the density, temperature, composition, and angular distributions of the low-energy plasma observed from the E-region ionosphere out into the magnetosphere to an altitude of 2.5 earth radii (Re). From the polar cap to the inner plasmasphere, parallel and perpendicular electric fields, polar wind flow, and equilibrium diffusion appear to be involved in the ionospheric-magnetospheric coupling of the low energy plasma.

Green, J. L.↗

The solar/interplanetary/magnetosphere/ionosphere connection - A strategy for prediction of geomagnetic storms

A physically-based strategy for the prediction of geomagnetic/ionospheric disturbances, the Solar-Terrestrial/Environmental Model (STEM 2000), is proposed, with application to the prediction of periods of spacecraft charging. Synoptic solar observations provide input for MHD models for flare occurrence, propagation of coronal disturbances, and high speed solar wind streams. A three-dimensional interplanetary MHD model determines solar wind parameters including the energy flux and the cross-magnetosphere tail electric field. Observational earth data are used to predict local time, high latitude ionospheric disturbances which have an impact on the ionospheric structure.

Dryer, M.↗

The day-to-day variability in ionospheric electric fields and currents

The daily variations in ionospheric drift velocities are examined from incoherent scatter measurements at Millstone Hill. The data with summed Kp greater than 24 behave differently from those with low magnetic activity and basically follow the convection pattern but have large day-to-day variations. The influence of the magnetic conjugate point is discussed, and solar cycle variations are examined in conjunction with geomagnetic variations. Ionospheric currents calculated by using a semidiurnal neutral wind model are in good agreement with ground-based magnetograms for low magnetic activity, but the E region neutral wind model appears to be applicable only to this case.

Kirchhoff, V. W. J. H.↗

Setting cost targets for zero-emission electricity generation technologies

Clean energy deployment scenarios typically assume a diverse mix of low-emission generation. However, because of historically low natural gas prices and cost reductions for onshore wind and photovoltaic technologies, recent new capacity deployment, especially in the United States, has come largely from these three generation sources. Here, we quantify competitive cost targets for three less-common zero-emission generation technologies -- nuclear, concentrating solar, and offshore wind -- under a range of future conditions. We determine the cost targets based on the technologies' system value, such that technology value equals or exceeds its cost. Using a capacity expansion model that develops system-wide, economically optimal generation scenarios of the United States power sector, we find that nuclear, concentrating solar, and offshore wind would need to attain levelized cost ranges of $53-84/MWh, $65-91/MWh, and $39-77/MWh, respectively, to achieve 1% additional grid penetration. We refer to this metric as the 'required cost,' which is a technology's levelized cost of energy needed to achieve a specific penetration level. Higher penetrations lead to lower required costs as lower-cost generation is displaced. We estimate that to reach 10% penetration, the required cost for nuclear declines to $45-76/MWh. Because of resource variability and increased transmission needs for concentrating solar power and offshore wind, even lower costs are needed to reach higher penetrations: required cost ranges to achieve 10% penetration are estimated to be $30-56/MWh and $18-40/MWh for these two technologies respectively. Our analysis informs research and development priorities and the design of policies supporting clean technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗