Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Solar process water heat for the IRIS images custom color photo lab

The solar facility located at a custom photo laboratory in Mill Valley, California is described. It was designed to provide 59 percent of the hot water requirements for developing photographic film and domestic hot water use. The design load is to provide 6 gallons of hot water per minute for 8 hours per working day at 100 F. It has 640 square feet of flat plate collectors and 360 gallons of hot water storage. The auxillary back up system is a conventional gas-fired water heater. Site and building description, subsystem description, as-built drawings, cost breakdown and analysis, performance analysis, lessons learned, and the operation and maintenance manual are presented.

Source record↗

NASA Johnson Space Center's Energy and Sustainability Efforts

This viewgraph presentation reviews the efforts that NASA is making to assure a sustainable environment and energy savings at the Johnson Space Center. Sustainability is defined as development that meets the needs of present generations without compromising the ability of future generations to meet their own needs. The new technologies that are required for sustainable closed loop life support for space exploration have uses on the ground to reduce energy, greenhouse gas emissions, and water use. Some of these uses are reviewed.

Ewert, Michael K.↗

Water purification

Production of decontaminated water from contaminated water using a vessel, an inlet to the vessel wherein the contaminated water is introduced into the vessel, an outlet to the vessel wherein the decontaminated water is removed from the vessel, a plasmonic-photocatalyst membrane connected to the vessel, plasmonic nanoparticles or nanostructures connected to the plasmonic-photocatalyst membrane, and a source of ultraviolet light that directs ultraviolet light onto the vessel, the plasmonic-photocatalyst membrane, the plasmonic nanoparticles or nanostructures, and the contaminated water to produce the decontaminated water from the contaminated water.

Brisbin, Ryan P.↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗

Water hyacinths for upgrading sewage lagoons to meet advanced wastewater treatment standards, part 2

Field tests using water hyacinths as biological filtration agents were conducted in the Mississippi gulf coast region. The plants were installed in one single cell and one multiple cell sewage lagoon systems. Water hyacinths demonstrated the ability to maintain BOD5 and total suspended solid (TSS) levels within the Environmental Protection Agency's prescribed limits of 30 mg/lBOD5 and 30 mg/l TSS. A multiple cell sewage lagoon system consisting of two aerated and one water hyacinth covered cell connected in series demonstrated the ability to maintain BOD5 and TSS levels below 30 mg/l year-round. A water hyacinth covered lagoon with a surface area of 0.28 hectare containing a total volume of 6.8 million liters demonstrated the capacity to treat 437,000 to 1,893,000 liters of sewage influent from 2.65 hectares of aerated lagoons daily and produce an effluent that met or exceeded standards year-round.

Wolverton, B. C.↗

Landsat - A satellite surface water divining rod

A DAM (Detection and Mapping) package is developed to provide accurate up-to-date economical and properly formatted maps of surface water using Landsat earth resources satellite digital data in order to detect and locate unrecorded water impoundments. The operational procedure is discussed in terms of data acquisition, establishment of the control network, specification of map characteristics, and generation of maps. Preliminary evaluations essentially indicate that the DAM package can be readily used by personnel unfamiliar with computer processing of remote sensing data, that no false detections are encountered, and that detection accuracy of surface water impoundments greater than 4 hectares is between 95-98%. However, terrain shadows present a problem in mountainous areas at low sun angles. A total cost of less than 15 cents per sq mile to compile the inventory is noted.

Hancock, K. J.↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Hydrogen production from salt water by Marine blue green algae and solar radiation

Two marine bluegreen algae, Oscillatoria sp. Miami BG 7 and Synechococcus sp Miami 041511 have been selected as the result of over 10 years continuous and intensive effort of isolation, growth examination, and the screening of hydrogen photoproduction capability in this laboratory. Both strains photoproduced hydrogen for several days at high rates and a quantity of hydrogen was accumulated in a closed vessel. Overall hydrogen donor substance of the hydrogen photoproduction was found to be salt water. Using strain Miami BG 7, a two step method of hydrogen photoproduction from salt water was successfully developed and this was recycled several times over a one month period using both free cells and immobilized cells in both indoor and outdoor under natural sunlight. According to these experiments, a prototype floating hydrogen production system was designed for further development of the biosolar hydrogen production system.

Mitsui, A.↗

What is Water's Role in a Carbon Neutral Future? A Summary of Findings from a Webinar Series

There has been ever-growing interest and engagement regarding net-zero and carbon neutrality goals, with many nations committing to steep emissions reductions by mid-century. Although water plays critical roles in various sectors, there has been a distinct gap in discussions to date about the role of water in the transition to a carbon neutral future. To address this need, a webinar was convened in April 2022 to gain insights into how water can support or influence active strategies for addressing emissions activities across energy, industrial, and carbon sectors. The webinar presentations and discussions highlighted various nuances of direct and indirect water use both within and across technology sectors (Figure ES-1). For example, hydrogen and concrete production, water for mining, and inland waterways transportation are all heavily influenced by the energy sources used (fossil fuels vs. renewable sources) as well as local resource availabilities. Algal biomass, on the other hand, can be produced across diverse geographies (terrestrial to sea) in a range of source water qualities, including wastewater and could also support pollution remediation through nutrient and metals recovery. Finally, water also influences carbon dynamics and cycling within natural systems across terrestrial, aquatic, and geologic systems. These dynamics underscore not only the critical role of water within the energy-water nexus, but also the extension into the energy-watercarbon nexus.

54 ENVIRONMENTAL SCIENCES↗

Measurement of total organic concentration in water

Instrument for determining total organic concentration in water uses no corrosive reagents or gases. Instead continuous ultraviolet photolysis process converts organic compounds to carbon dioxide (CO2). CO2 electrode is used to measure CO2 content. Only reagent necessary is oxygen, generated in situ by electrolyzing some water. In addition to application in aerospace industry, system has potential uses in pollution monitoring and in laboratory analyses.

Winkler, E.↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stomatal conductance, not biochemistry, drives low temperature acclimation of photosynthesis in Populus balsamifera , regardless of nitrogen availability

Low temperature thermal acclimation may require adjustments to nitrogen and water use to sustain photosynthesis due to slow enzyme functioning and high-water viscosity. However, understanding of photosynthetic acclimation to temperatures below 11°C is limited. Here, we acclimated Populus balsamifera to 6 °C and 10 °C (6A and 10A, respectively) and provided the trees with either high or low N fertilizer. We measured net CO 2 assimilation rates (A net ), stomatal conductance (g s ), maximum rates of Rubisco carboxylation (V cmax ) and electron transport (J max ), and dark respiration (R d ) at leaf temperatures of 2, 6, 10, 14 and 18 °C, along with leaf N concentrations. The 10A trees had higher A net than the 6A trees at warmer leaf temperatures, which was correlated with higher g s in the 10A trees. The instantaneous temperature responses of V cmax , J max and R d were similar for trees from both acclimation temperatures. While soil N availability increased leaf N concentrations, this had no effect on acclimation of photosynthesis or respiration. Our results indicate that acclimation below 11°C occurred primarily through changes in stomatal conductance, not photosynthetic biochemistry, and was unaffected by short-term N supply. Thermal acclimation of stomatal conductance should therefore be a priority for future carbon cycle model development.

54 ENVIRONMENTAL SCIENCES↗

Microbial Characterization of Internal Active Thermal Control System (IATCS) Hardware Surfaces after Five Years of Operation in the International Space Station

A flex hose assembly containing aqueous coolant from the International Space Station (ISS) Internal Active Thermal Control System (IATCS) consisting of a 2 foot section of Teflon hose and quick disconnects (QDs) and a Special Performance Checkout Unit (SPCU) heat exchanger containing separate channels of IATCS coolant and iodinated water used to cool spacesuits and Extravehicular Mobility Units (EMUS) were returned for destructive analyses on Shuttle return to flight mission STS-114. The original aqueous IATCS coolant used in Node 1, the Laboratory Module, and the Airlock consisted of water, borate (pH buffer), phosphate (corrosion control), and silver sulfate (microbiological control) at a pH of 9.5 +/- 0.5. Chemical changes occurred after on-orbit implementation including a decrease to pH 8.4 due to the diffusion of carbon dioxide through the Teflon hoses, an increase in nickel ions due to general corrosion of heat exchanger braze coatings, a decrease in phosphate concentration due to precipitation of nickel phosphate, and the rapid disappearance of silver ions due to deposition on hardware surfaces. Also associated with the coolant chemistry changes was an increase in planktonic microorganisms from less than 100 colony forming units (CFU) per 100 ml to approximately 1 million CFU per 100 ml. Attachment and growth of microorganisms to the system surfaces (biofilm) was suspected due to the levels of planktonic microorganisms in the coolant. Biofilms can reduce coolant flow, reduce heat transfer, amplify degradation of system materials initiated by chemical corrosion, and enhance mineral scale formation.

Roman, Monsi C.↗

Regolith Volatile Recovery at Simulated Lunar Environments

Lunar Polar Volatiles: Permanently shadowed craters at the lunar poles contain water, 5 wt according to LCROSS. Interest in water for ISRU applications. Desire to ground truth water using surface prospecting e.g. Resource Prospector and RESOLVE. How to access subsurface water resources and accurately measure quantity. Excavation operations and exposure to lunar environment may affect the results. Volatile capture tests: A series a ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations. Sample removal and transfer. Volatiles loss during sampling operations. Concept of operations, Instrumentation. This presentation is a progress report on volatiles capture results from these tests with lunar polar drill prototype hardware.

thermal vacuum tests↗

Volatiles Loss from Water Bearing Regolith Simulant at Lunar Environments

Permanently shadowed craters at the lunar poles contain water, ~5 wt% according to LCROSS. Interest in water for ISRU applications. Desire to 'ground truth' water using surface prospecting; e.g. Resource Prospector (RP) & RESOLVE. How to access subsurface water resources and accurately measure quantity; Excavation operations and exposure to lunar environment may affect the results A series a ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations: Sample removal and transfer, Volatiles loss during sampling operations, Concept of operations, Instrumentation. This presentation covers: The capabilities of the VF-13 Thermal Vacuum Chamber (Tvac). The Resource Prospector TVAC hardware. The summary and results of 5 years of RP volatiles tests; 43 viable samples

In-situ Resource Utilization↗

Irrigation Water Demand Sensitivity to Climate Variability across the Contiguous United States

Climate variability is an important driver of irrigation water use in many regions. Efforts to anticipate climate change impacts on future water availability can benefit from understanding how irrigation water demand has responded to these drivers to date. Here we apply satellite derived data, meteorological reanalysis, an advanced land surface model, and available state level reports to quantify irrigation demand sensitivities to temperature and precipitation across the Contiguous United States, for the period of 2002-2017. As expected, strong negative correlations are found between precipitation and irrigation withdrawals, both simulated and reported. Temperature sensitivities, however, vary by region and season, as do the interactive effects of temperature and precipitation on irrigation. Climate-induced irrigation variability is largest in transitional climate zones. These transitional zones are generally separate from the regions where rates of irrigation withdrawals are greatest, such that climate-induced variability in irrigation demand represents a water resource consideration that is distinct from chronic over pumping.

Wanshu Nie↗