Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Evaluation of Pozzolan-substituted Cast Stone for Pretreated Hanford Tank Waste

Portland cement. The future availability of quality Class F fly ash has come into question as coal-fired power plants are being converted to gas or taken offline. Consequently, alternative pozzolanic reagents are being evaluated for fly ash replacement in cementitious matrices for treating radioactive waste and debris. In 2023 and 2024, Savannah River National Laboratory (SRNL) was funded to evaluate natural pozzolans for the replacement of Class F fly in the Savannah River Site (SRS) Saltstone formulation. Based on the promising results and uncertain availability of Class F fly ash in the northwestern US, Hanford Tank Waste Operations & Closure, LLC (H2C) requested SRNL to evaluate the potential for substituting natural pozzolans in the Hanford West Area Pretreated Low Activity Tank Waste (PTW/LAW) Cast Stone formulation1 . Task 1 in this request was to determine the change in Cast Stone volume resulting from stabilization/solidification of 1 L of PTW/LAW tank waste. The densities of three (Hess Pumice, tephra pumice, and clinoptilolite zeolite) pozzolan-substituted Baseline Cast Stone mixes were determined, and volume changes relative to the fly ash-Baseline Mix with a water-to-dry mix = 0.40 were calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A study to determine the flight characteristics and handling qualitites of variable geometry spacecraft. Volume 3: Low L/D concept with fold-down wings

A study was conducted to determine the flight characteristics and wing deployment transients for a variable geometry spacecraft concept having a hypersonic lift-to-drag ratio near 1.0, and employing fold-down wings. Unpowered flight conditions were considered throughout the study. The body of the spacecraft uses a trapezoidal cross section. The variable geometry wings, stowed in the sides of the vehicle, are deployed at transonic speeds.

Friedman, G. R.↗

Results of tests in the NASA/LaRC 31-inch CFHT on an 0.010-scale model (32-OT) of the space shuttle configuration 3 to determine the RCS jet flowfield interaction effects on aerodynamic characteristics (IA60/0A105), volume 1

Tests were conducted in the 31-inch continuous Flow Hypersonic Wind Tunnel to determine RCS jet interaction effect on the hypersonic aerodynamic and stability and control characteristics prior to RTLS abort separation. The model used was an 0.010-scale replica of the Space Shuttle Vehicle Configuration 3. Hypersonic stability data were obtained from tests at Mach 10.3 and dynamic pressure of 150 psf for the integrated Orbiter and external tank and the Orbiter alone. RCS modes of pitch, yaw, and roll at free flight dynamic pressure simulation of 7, 20, and 50 psf were investigated. The effects of speedbrake, bodyflap, elevon, and airleron deflections were also investigated.

Thornton, D. E.↗

Atomistic modeling of surface and grain boundary dislocation nucleation in FCC metals

Dislocation nucleation plays a critical role in the plastic deformation of crystalline materials. However, it is challenging to predict the active mode and associated rate of dislocation nucleation under typical experimental loading conditions through molecular dynamics simulation due to timescale limitations. In this report we use the free-end nudged elastic band method to determine the activation energies and activation volumes of dislocation nucleation in four typical face-centered cubic metals of Au, Al, Cu and Ni. We focus on the representative processes of surface and grain boundary dislocation nucleation. The atomistically determined activation volumes of these dislocation nucleation processes are larger than 10b3 (with b being the Burgers vector length) under typical experimental loading conditions. These results are compared with experimentally measured activation volumes in ultrafine-grained and nanocrystalline metals, thereby providing mechanistic insight into their rate-controlling deformation mechanisms.

36 MATERIALS SCIENCE↗

Lattice QCD Thermodynamics

The QCD transition is studied using lattice simulations. The order of the transition is determined via a finite volume analysis. It is found to be an analytic crossover. The transition temperature is determined in physical units using three different definitions. All results are obtained using five different lattice spacings(a {approx_equal} 0.3,0.2,0.15, 0.12 and 0.1 fm) and a continuum extrapolation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Programmable temperature control system for biological materials

A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.

Anselmo, V. J.↗

Two-Nucleon Systems in a Finite Volume

I present the formalism and methodology for determining the nucleon-nucleon scattering parameters from the finite volume spectra obtained from lattice quantum chromodynamics calculations. Using the recently derived energy quantization conditions and the experimentally determined scattering parameters, the bound state spectra for finite volume systems with overlap with the 3S1-3D3 channel are predicted for a range of volumes. It is shown that the extractions of the infinite-volume deuteron binding energy and the low-energy scattering parameters, including the S-D mixing angle, are possible from Lattice QCD calculations of two-nucleon systems with boosts of |P| <= 2pi sqrt{3}/L in volumes with spatial extents L satisfying fm <~ L <~ 14 fm.

Briceno, Raul↗

Automated gas burette system for evolved hydrogen measurements

This paper reports a simple and efficient gas burette system that allows automated determination of evolved gas volume in real time using only temperature and pressure measurements. The system is reliable and has been used successfully to study the hydrogen release kinetics of ammonia borane thermolysis. The system is especially suitable for bench scale studies involving small batches and potentially rapid reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Intracranial Pressure And Volume Noninvasively

Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

Cantrell, John H.↗

Estimating Residual Solids Volume In Underground Storage Tanks

The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tumor Volume Reduction Rate Measured by Magnetic Resonance Volumetry Correlated With Pathologic Tumor Response of Preoperative Chemoradiotherapy for Rectal Cancer

Purpose: To determine whether the tumor volume reduction rate (TVRR) measured using three-dimensional region-of-interest magnetic resonance volumetry correlates with the pathologic tumor response after preoperative chemoradiotherapy (CRT) for locally advanced rectal cancer. Methods and Materials: The study included 405 patients with locally advanced rectal cancer (cT3-T4) who had undergone preoperative CRT and radical proctectomy. The tumor volume was measured using three-dimensional region-of-interest magnetic resonance volumetry before and after CRT but before surgery. We analyzed the correlation between the TVRR and the pathologic tumor response in terms of downstaging and tumor regression grade (TRG). Downstaging was defined as ypStage 0-I (ypT0-T2N0M0), and the TRG proposed by Dworak et al. was used. Results: The mean TVRR was 65.0% {+-} 22.3%. Downstaging and complete regression occurred in 167 (41.2%) and 58 (14.3%) patients, respectively. The TVRRs according to ypT classification (ypT0-T2 vs. ypT3-T4), ypN classification (ypN0 vs. ypN1-N2), downstaging (ypStage 0-I vs. ypStage II-III), good regression (TRG 3-4 vs. TRG 1-2), and complete regression (TRG 4 vs. TRG 1-3) were all significantly different (p <.05). When the TVRR was categorized into three groups (<60%, 60-80%, and >80%), the rates of ypT0-T2, ypN0, downstaging, and good regression were all significantly greater for patients with a TVRR of {>=}60%, as was the complete regression rate for patients with a TVRR >80% (p <.05). Conclusion: The TVRR measured using three-dimensional region-of-interest magnetic resonance volumetry correlated significantly with the pathologic tumor response in terms of downstaging and TRG after preoperative CRT for locally advanced rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clouds and the Earth's Radiant Energy System (CERES) Algorithm Theoretical Basis Document: Cloud Analyses and Determination of Improved Top of Atmosphere Fluxes (Subsystem 4) - Volume 3

The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and Earth's Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies is outlined. Volume 3 details the advanced CERES methods for performing scene identification and inverting each CERES scanner radiance to a top-of-the-atmosphere (TOA) flux. CERES determines cloud fraction, height, phase, effective particle size, layering, and thickness from high-resolution, multispectral imager data. CERES derives cloud properties for each pixel of the Tropical Rainfall Measuring Mission (TRMM) visible and infrared scanner and the Earth Observing System (EOS) moderate-resolution imaging spectroradiometer. Cloud properties for each imager pixel are convolved with the CERES footprint point spread function to produce average cloud properties for each CERES scanner radiance. The mean cloud properties are used to determine an angular distribution model (ADM) to convert each CERES radiance to a TOA flux. The TOA fluxes are used in simple parameterization to derive surface radiative fluxes. This state-of-the-art cloud-radiation product will be used to substantially improve our understanding of the complex relationship between clouds and the radiation budget of the Earth-atmosphere system.

Source record↗

Application of modified Twomey techniques to invert lidar angular scatter and solar extinction data for determining aerosol size distributions

Polarization properties of the angularly scattered laser light from a volume of air are used to determine the size distribution of the aerosol particles within the volume by the use of appropriate inversion techniques. Similar techniques are employed to determine a mean size distribution of the particulates within a vertical column through the atmosphere from determinations of the aerosol optical depth as a function of wavelength. In both of these examples, a modification of an inversion technique originally described by Twomey has been employed. Details of this method are presented as well as results from actual measurements employing bistatic lidar and solar radiometer.

Herman, B. M.↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗