Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Electron gun jitter effects on beam bunching

For routine operation of Beijing Electron Positron Collider II (BEPCII) linac, many factors may affect the beam bunching process directly or indirectly. We present the measurements and analyses of the gun timing jitter, gun high voltage jitter, and beam energy at the exit of the standard acceleration section of the linac quantitatively. Almost 80 mV and more than 200 ps of gun high voltage and time jitters have ever been measured, respectively. It was analyzed that the gun timing jitter produced severe effects on beam energy than the gun high voltage jitter, if the timing jitter exceeded 100 ps which eventually deteriorates both the beam performance and the injection rate to the storage ring.

43 PARTICLE ACCELERATORS↗

Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model for a wider range of electrical load impedances under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmented wall-less hall thruster

Disclosed is a miniaturized plasma propulsion device with minimized surface area of the thruster walls exposed to the plasma and, as a result, reduced plasma-surface interactions including a set of segmented electrodes to facilitate the following improvements compared to relevant existing technologies: 1) control of the plasma flow including focusing of the plasma plume 2) increase of the thrust 2) reduction of inefficiencies associated with the electron cross field current, and 3) mitigation of low frequency oscillations. The electrodes affect all these actions when a DC or modulated voltage is applied to one or all of them with the same or different amplitudes, with the same or different frequencies or phases which are all optimized to realize the best performance through changes in the acceleration and/or ionization regions. In addition, the applied voltage to the main electrodes may also be modulated.

Simmonds, Jacob↗

A laser spectroscopic study on Xe{sup +} ion transport phenomena in the ExB discharge of a Hall effect thruster

The Velocity Distribution Function (VDF) of metastable Xe{sup +} ions was measured along the channel axis of the 5 kW-class PPS registered X000 Hall effect thruster by means of Laser Induced Fluorescence spectroscopy at 834.72 nm for various voltages, magnetic fields and mass flow rates. Axial velocity and dispersion profiles are compared to on-axis profiles obtained with the 1.5 kW-class PPS100 thruster. Outcomes of the comparison are threefold. (i) The broadening of the FDV across the region of strong magnetic field is a general feature for Hall thrusters. It originates in the overlap between ionization and acceleration layers. The velocity dispersion increases with the discharge voltage; it reaches up to 200 eV in unit of kinetic energy at 700 V. (ii) Most of the acceleration potential ({approx_equal}70%) is localized outside the thruster channel whatever the thruster size and operating conditions. The electric field moves upstream when the applied voltage is ramped up; in other words the fraction of potential inside the channel increases with the voltage; (iii) A non negligible amount of very slow and very fast (kinetic energy higher than the applied potential) Xe{sup +} ions are always observed. Such ions may find their origin in space and temporal oscillations of the electric field as suggested by numerical simulations carried out with a hybrid model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High Voltage, High Rep-Rate, High Duty Factor Stacked Transformer Modulator

A high voltage modulator has been built and installed at Fermi National Accelerator Laboratory for the purpose of driving the gun anode of the Tevatron Electron Lens (TEL). It produces a defined voltage for each of the 36 (anti)proton bunches. This modulator employs five transformers to produce high voltage at a high repetition rate and high duty factor. It is capable of outputting sustained complex waveforms having peak voltages over 6 kV and average periodic rates up to 450 kHz with voltage transitions occurring at 395 ns intervals. This paper describes key aspects of the hardware design and performance.

Saewert, G. W.↗

High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems related to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Microwave Assisted Discharge Inductive Plasma Accelerator

A new plasma accelerator concept that employs electrodeless plasma preionization and pulsed inductive acceleration is presented. Preionization is achieved through an electron cyclotron resonance discharge that produces a weakly-ionized plasma at the face of a conical theta pinch-shaped inductive coil. The presence of the preionized plasma allows for current sheet formation at lower discharge voltages than those found in other pulsed inductive accelerators. The location of an electron cyclotron resonance discharge can be controlled through the design of the applied magnetic field in the thruster. A finite-element model of the magnetic field was used as a design tool, allowing for the implementation of an arrangement of permanent magnets that yields a small volume of preionized propellant at the coil face. This allows for current sheet formation at the face of the inductive coil, minimizing the initial inductance of the pulse circuit and maximizing the potential efficiency of the new accelerator.

Hallock, Ashley K.↗

Design of a Microwave Assisted Discharge Inductive Plasma Accelerator

The design and construction of a thruster that employs electrodeless plasma preionization and pulsed inductive acceleration is described. Preionization is achieved through an electron cyclotron resonance discharge that produces a weakly-ionized plasma at the face of a conical theta pinch-shaped inductive coil. The presence of the preionized plasma allows for current sheet formation at lower discharge voltages than those employed in other pulsed inductive accelerators that do not employ preionization. The location of the electron cyclotron resonance discharge is controlled through the design of the applied magnetic field in the thruster. Finite element analysis shows that there is an arrangement of permanent magnets that yields a small volume of resonant magnetic field at the coil face. Preionization in the resonant zone leads to current sheet formation at the coil face, which minimizes the initial inductance of the pulse circuit and maximizes the potential electrical efficiency of the accelerator. A magnet assembly was constructed around an inductive coil to provide structural support to the selected arrangement of neodymium magnets. Measured values of the resulting magnetic field compare favorably with the finite element model.

Hallock, Ashley K.↗

Vibration piezoelectric energy harvester with multi-beam

This work presents a novel vibration piezoelectric energy harvester, which is a micro piezoelectric cantilever with multi-beam. The characteristics of the PZT (Pb(Zr{sub 0.53}Ti{sub 0.47})O{sub 3}) thin film were measured; XRD (X-ray diffraction) pattern and AFM (Atomic Force Microscope) image of the PZT thin film were measured, and show that the PZT (Pb(Zr{sub 0.53}Ti{sub 0.47})O{sub 3}) thin film is highly (110) crystal oriented; the leakage current is maintained in nA magnitude, the residual polarisation Pr is 37.037 μC/cm{sup 2}, the coercive field voltage Ec is 27.083 kV/cm, and the piezoelectric constant d{sub 33} is 28 pC/N. In order to test the dynamic performance of the energy harvester, a new measuring system was set up. The maximum output voltage of the single beam of the multi-beam can achieve 80.78 mV under an acceleration of 1 g at 260 Hz of frequency; the maximum output voltage of the single beam of the multi-beam is almost 20 mV at 1400 Hz frequency. .

36 MATERIALS SCIENCE↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗

Dynamics of positive probes in underdense, strongly magnetized, E×B drifting plasma: Particle-in-cell simulations

Electron trapping, electron heating, space-charge wings, wake eddies, and current collection by a positive probe in E×B drifting plasma were studied in three-dimensional electromagnetic particle-in-cell simulations. In these simulations, electrons and ions were magnetized with respect to the probe and the plasma was underdense (ω{sub pe}<ω{sub ce}). A large drift velocity (Mach 4.5 with respect to the ion acoustic speed) between the plasma and probe was created with background electric and magnetic fields. Four distinct regions developed in the presences of the positive probe: a quasi-trapped electron region, an electron-depletion wing, an ion-rich wing, and a wake region. We report on the observations of strong electron heating mechanisms, space-charge wings, ion cyclotron charge-density eddies in the wake, electron acceleration due to a magnetic presheath, and the current-voltage relationship.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power Supply

Maxwell Laboratories capacitor charging power supply is the first commercial spinoff from the NASA CCDS program - a consortia of industries and government establishments to accelerate development of ground and space based commercial applications of NASA technology. The power supply transforms and conditions large voltages to charge capacitors used in x-ray sources, medical accelerators, etc. It is lighter, more reliable, more compact and efficient. Originally developed for space lasers, its commercial potential was soon recognized.

Source record↗

NDCX-II PULSED POWER SYSTEM AND INDUCTION CELLS

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) is currently finalizing the design of NDCX-II, the second phase of the Neutralized Drift Compression Experiment, which will use an ion beam to explore Warm Dense Matter (WDM) and Inertial Fusion Energy (IFE) target hydrodynamics. The ion induction accelerator will include induction cells and Blumleins from the decommissioned Advanced Test Accelerator (ATA) at Lawrence Livermore National Laboratory (LLNL). A test stand has been built at Lawrence Berkeley National Laboratory (LBNL) to test refurbished ATA induction cells and pulsed power hardware for voltage holding and ability to produce various compression and acceleration waveforms. The performance requirements, design modifications, and test results will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Module Precursors and Prognostics

This project focuses on finding and utilizing electrical properties (precursors) of power electronic devices and modules whose changes have strong correlations with different modes and levels of degradations in order to realize online and lightweight state of health evaluation and fault diagnosis. Results from this project will contribute to higher safety, reliability, and power density of power electronic components. The approaches mainly include reviewing academic literature and industry practices for state of the art precursor identification and extraction, accelerated life cycles (ALC) of various power modules to create different degradations in-house, and developing techniques for gate-driver-integratable precursor detection circuit. In FY24, the results includes two sets of definitively detected aging precursors (on-state resistance and gate threshold voltage) for two sets of power modules respectively, controlled accelerated lifetime cycling of multiple silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) modules, and the development and validation of a gate voltage detection system.

ADVANCED PROPULSION SYSTEMS↗

A Three–Dimensional Nanoscale View of Electrocatalyst Degradation in Hydrogen Fuel Cells

The loss of platinum (Pt) electrochemically active surface area (ECSA) is a critical degradation mode that often becomes a limiting factor for heavy-duty proton exchange membrane fuel cell vehicles. High surface area carbon supports have been shown to improve Pt dispersion and limit detrimental ionomer-electrocatalyst interactions due to their large interior pore volume. Here, in this work, using automated scanning transmission electron tomography, the degradation of nanoparticles located on the interior versus exterior surfaces of the carbon support is compared following a catalyst-specific accelerated stress test (AST) of 90,000 voltage cycles between 0.6 V to 0.95 V. The results reveal a notable increase in median particle size for both interior and exterior Pt catalyst particles, with a slightly higher increase in particle size distribution and loss of specific surface area for the particles located on the exterior carbon surface. The fraction of Pt nanoparticles that reside within the interior of the carbon support also increased following the AST test, accompanied by evidence of an increase in average carbon mesopore size. Here, the results shed light on the degradation mechanisms affecting electrochemical properties and the enhanced particle accessibility at lower relative humidity.

08 HYDROGEN↗

Pt Nanoparticles on Atomic-Metal-Rich Carbon for Heavy-Duty Fuel Cell Catalysts: Durability Enhancement and Degradation Behavior in Membrane Electrode Assemblies

Proton exchange membrane fuel cells (PEMFCs) are a promising zero-emission power source for heavy-duty vehicles (HDVs). However, long-term durability of up to 25,000 h is challenging because current carbon support, catalyst, membrane, and ionomer developed for traditional light-duty vehicles cannot meet the stringent requirement. Therefore, understanding catalyst degradation mechanisms under the HDV condition is crucial for rationally designing highly active and durable platinum group metal (PGM) catalysts for high-performance membrane electrode assemblies (MEAs). Herein, we report a PGM catalyst consisting of platinum nanoparticles with a high content (40 wt %) on atomic-metal-site (e.g., MnN 4 )-rich carbon support. MEAs with the Pt (40 wt %)/Mn–N–C cathode catalyst achieved significantly enhanced performance and durability, generating 1.41 A cm –2 at 0.7 V under HDV conditions (0.25 mgPt cm –2 and 250 kPa abs pressure) and retaining 1.20 A cm –2 after an extended and accelerated stress test up to 150,000 voltage cycles. Electron microscopy studies indicate that most fine Pt nanoparticles are retained on or/and in the carbon support covered with the ionomer throughout the catalyst layer at the end of life. During the long-term stability test, the observed electrochemical active surface area reduction and performance loss primarily result from Pt depletion in the catalyst layer due to Pt dissolution and redeposition at the interface of the cathode and membrane. Importantly, the first-principle density functional theory calculations further reveal a support entrapment effect of the Mn–N–C, in which the MnN 4 site can specifically adsorb the Pt atom and further retard the Pt dissolution and migration, therefore enhancing long-term MEA durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗