Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Remote sensing of atmospheric water vapor and liquid water with the Nimbus 5 microwave spectrometer

The Nimbus 5 satellite is provided with a passive microwave spectrometer (NEMS) incorporating channels at 22.235 and 31.4 GHz to measure atmospheric water vapor and liquid water over ocean. The discussion covers principles of atmospheric water determination, accuracy of measurements, observations of specific storms and fronts, and observations of water vapor and liquid water on a global scale. The NEMS experiment has demonstrated the ability of a two-channel microwave spectrometer to determine integrated abundances of water vapor and liquid water with estimated rms accuracies of 0.2 and 0.01 g per sq cm, respectively. The data can be used to plot global maps or accumulate global statistics.

Staelin, D. H.↗

Excess liquid in heat-pipe vapor spaces

A mathematical model is developed of excess liquid in heat pipes that is used to calculate the parameters governing the axial flow of liquid in fillets and puddles that form in vapor spaces. In an acceleration field, the hydrostatic pressure variation is taken into account, which results in noncircular meniscus shapes. The two specific vapor-space geometries considered are circular and the 'Dee-shape' that is formed by a slab wick in a circular tube. Also presented are theoretical and experimental results for the conditions under which liquid slugs form at the ends of the vapor spaces. These results also apply to the priming of arteries.

Eninger, J. E.↗

Improved waste water vapor compression distillation technology

The vapor compression distillation process is a method of recovering potable water from crewman urine in a manned spacecraft or space station. A description is presented of the research and development approach to the solution of the various problems encountered with previous vapor compression distillation units. The design solutions considered are incorporated in the preliminary design of a vapor compression distillation subsystem. The new design concepts are available for integration in the next generation of support systems and, particularly, the regenerative life support evaluation intended for project Spacelab.

Johnson, K. L.↗

Removal of ammonia from urine vapor by a dual-catalyst system

The feasibility of removing ammonia from urine vapor by a low-temperature dual-catalyst system has been demonstrated. The process is based on the catalytic oxidation of ammonia to a mixture of nitrogen, nitrous oxide, and water, followed by a catalytic decomposition of the nitrous oxide into its elements. Potential ammonia oxidation and nitrous oxide decomposition catalysts were first screened with artificial gas mixtures, then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual-catalyst bed arrangement was found that achieved the removal of ammonia and also organic carbon, and recovered water of good quality from urine vapor.

Budininkas, P.↗

Water-vapor pressure control in a volume

The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

Scialdone, J. J.↗

Degree of vaporization using an airblast type injector for a premixed-prevaporized combustor

Vaporization data that could be useful in designing premixed-prevaporized fuel preparation systems for gas turbine combustors are presented. The effect of the experimental parameters on vaporization was found to be E = T sub in tau 0.18 (V sub ref + 38) (P sub in + 35)/203000 where E is the degree of vaporization in percent, T sub in the inlet air temperature in K over the range 450 to 700 K, the residence time in ms over the range 4.3 to 23.8 ms, V sub ref the reference velocity in m/s over the range 5 to 22 m/s, and P sub in the inlet pressure in MPa over the range 0.18 to 0.59 MPa. Jet A and Diesel no. 2 fuels were tested for the effect of inlet air temperature and were found to have nearly identical results.

Tacina, R. R.↗

Remote sensing of atmospheric water vapor, liquid water and wind speed at the ocean surface by passive microwave techniques from the Nimbus-5 satellite

The microwave brightness temperature measurements for Nimbus-5 electrically scanned microwave radiometer and Nimbus E microwave spectrometer are used to retrieve the atmospheric water vapor, liquid water and wind speed by a quasi-statistical retrieval technique. It is shown that the brightness temperature can be utilized to yield these parameters under various weather conditions. Observations at 19.35 GHz, 22.235 GHz and 31.4 GHz were input to the regression equations. The retrieved values of these parameters for portions of two Nimbus-5 orbits are presented. Then comparison between the retrieved parameters and the available observations on the total water vapor content and the surface wind speed are made. The estimated errors for retrieval are approximately 0.15 g/sq cm for water vapor content, 6.5 mg/sq cm for liquid water content and 6.6 m/sec for surface wind speed.

Chang, A. T. C.↗

Mars: Water Vapor Observations from the Viking Orbiters

The global distribution of the water vapor has been mapped at low resolution throughout the period from the northern summer solstice to the following equinox. During this seasonal period the water vapor underwent a gradual redistribution, the latitude of maximum column abundance moving from the northern polar area to the equatorial latitudes. The total global vapor content remained approximately constant at the equivalent of about 1.3 cu km of ice. The various data obtained indicate that the residual polar caps are composed of water ice.

Farmer, C. B.↗

Water vapor in the lower stratosphere measured from aircraft flight

Water vapor in the lower stratosphere was measured in situ by two aluminum oxide hygrometers mounted on the nose of an RB57 aircraft. Data were taken nearly continuously from January to May 1974 from an altitude of approximately 11-19 km as the aircraft flew between 70 deg N and 50 deg S over the land areas in the Western Hemisphere. Pseudomeridional cross sections of water vapor and temperature were derived from the flight data and show mixing ratios predominantly between 2 and 4 microg/g with an extreme range of 1-8 microg/g. Measurement precision was estimated by comparing the simultaneously measured values from the two flight hygrometer systems. Accuracy was estimated to be about + or - 40% at 19 km. A height-averaged latitudinal cross section of water vapor indicates symmetry of wet and dry zones. This cross section is compared with other aircraft measurements and relates to meridional circulation models.

Hilsenrath, E.↗

Growth of single crystals by vapor transport

The primary objectives of the program were to establish basic vapor transport and crystal growth properties and to determine thermodynamic, kinetic and structural parameters relevant to chemical vapor transport systems for different classes of materials. An important aspect of these studies was the observation of the effects of gravity-caused convection on the mass transport rate and crystal morphology. These objectives were accomplished through extensive vapor transport, thermochemical and structural studies on selected Mn-chalcogenides, II-VI and IV-VI compounds.

Wiedemeier, H.↗

Microwave radiometer measurement of water vapor path delay: Data reduction techniques

Data reduction techniques are developed to compensate for water vapor path delay, a limiting error source in geodetic measurements made with very long baseline interferometry and in radio ranging to spacecraft. It is shown that water vapor path delay is proportional to a linear combination of saturation-corrected sky brightness temperatures, measured on and off the water vapor line. The effects of emission from liquid water droplets in clouds as well as most of the oxygen emission are removed by the off-line channel. Sky brightness temperatures are saturation-corrected or 'linearized' using estimates of effective sky temperatures made from surface temperature. Tipping curves are used to remove instrumental error. Coefficients are found by two methods: from a regression analysis of measured brightness temperatures versus radiosonde measured delay, and from a regression analysis of theoretical brightness temperatures versus radiosonde measured delay. In each case the coefficients are adjusted for differing climatic conditions by measurements of surface temperature, pressure, and relative humidity. Regression solutions are constrained to remove liquid water contributions and to give the correct slope for radiometer versus radiosonde path delay.

Claflin, E. S.↗

Remote sensing of seasonal distribution of precipitable water vapor over the oceans and inference of boundary layer structure

Over the ocean satellite infrared spectral measurements in the 18 micrometer water vapor band and the 11 micrometer window region were used to derive precipitable water vapor, w, in the atmosphere and the sea surface temperature, SST. Seasonal maps of w on the oceans derived from these data reveal the dynamical influence of the large scale atmospheric circulation. With the help of a model for the vertical distribution of water vapor, the configuration of the atmospheric boundary layer over the oceans can be inferred from w when the information of SST is combined. The gross seasonal mean structure of the boundary layer inferred in this fashion reveals the broad areas of the trade wind inversion and the convectively active areas such as the intertropical convergence zones.

Prabhakara, C.↗

Effect of degree of fuel vaporization on emissions for a premixed-prevaporized combustor system

The impact of the degree of fuel vaporization upon emission from a flametube combustor was studied using an inlet air pressure of 3 x 10 to the 5th power pascals, inlet air temperatures of 600K and 700K, a reference velocity of 35 meters per second and equivalence ratios of .6 and .72 using Jet A fuel. Incoming air was preheated to temperatures from 600K to 700K by a nonvitiating preheater. Jet A fuel was injected into this airstream through two different fuel injectors manifolded together and mounted in series upstream of a watercooled preforated plate flameholder. The fuel-air mixture burned in a watercooled combustor section. Samples of the fuel-air mixture upstream of the flameholder were obtained for analysis to determine the local degree of fuel vaporization and the fuel-air ratio. Samples of the combustion products were analyzed to determine gaseous emissions. The effects of vaporization on carbon monoxide and nitric on carbon monoxide and nitric oxide emissions are presented.

Cooper, L. P.↗

U-2 water vapor burden observations through the tropopause

A U-2 aircraft provided a platform for an infrared radiometer inferring water vapor burdens associated with the Intertropical Convergence Zone. Flight altitudes were 16 to 23 km. The radiometer system, coupled with an algorithm to produce an inverse solution of the radiative transfer equation, resulted in an rms error of 20 percent in the inferred water vapor burden. A unique, bivariate solution including radiance and vertical temperature profiles produced an essentially real-time solution for the water vapor burden. Results of the July 1977 missions over the Canal Zone region between latitudes 7.5 degrees N and 11.0 degrees N are presented.

Kuhn, P. M.↗

Condensation on a noncollapsing vapor bubble in a subcooled liquid

An experimental procedure is presented by which an estimate can be made of the condensation coefficient on a noncollapsing stationary vapor bubble in subcooled liquid nitrogen. Film boiling from a thin wire was used to generate vapor bubbles which remain fixed to the wire at their base. A balance was established between the evaporation in the thin annular region along the wire and the condensation in the vapor bubbles.

Baumeister, K. J.↗

Water vapor-nitrogen absorption at CO2 laser frequencies

The paper reports the results of a series of pressure-broadened water vapor absorption measurements at 27 CO2 laser frequencies between 935 and 1082 kaysers. Both multiple traversal cell and optoacoustic (spectrophone) techniques were utilized together with an electronically stabilized CW CO2 laser. Comparison of the results obtained by these two methods shows remarkable agreement, indicating a precision which has not been previously achieved in pressure-broadened studies of water vapor. The data of 10.59 microns substantiate the existence of the large (greater than 200) self-broadening coefficients determined in an earlier study by McCoy. In this work, the case of water vapor in N2 at a total pressure of 1 atm has been treated.

Peterson, J. C.↗

Condensation on a noncollapsing vapor bubble in a subcooled liquid

An experimental procedure is presented by which an estimate can be made of the condensation coefficient on a noncollapsing stationary vapor bubble in subcooled liquid nitrogen. The present experimental study utilizes film boiling from a thin wire to generate vapor bubbles which remain fixed to the wire at their base. A balance was established between the evaporation in the thin annular region along the wire and the condensation in the vapor bubbles.

Baumeister, K. J.↗

Water vapor as an error source in microwave geodetic systems: Background and survey of calibration techniques

Water vapor as an error source in radio interferometry systems is briefly examined. At microwave frequencies, the delay imposed by tropospheric water vapor becomes a limiting error source for high accuracy geodetic systems. The mapping of tropospheric induced errors into 'solved-for' parameters depends upon baseline length and observing strategy. Simulation analysis (and experience) indicates that in some cases, errors in estimating tropospheric delay can be magnified in their effect on baseline components. The various techniques by which tropospheric water can be estimated or measured are surveyed with particular consideration to their possible use as a calibration technique in support to very long baseline interferometry experiments. The method of remote sensing using a microwave radiometer seems to be the most effective way to provide an accurate estimate of water vapor delay.

Claflin, E. S.↗