At least 595 records · Page 33

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfeld, Michael P.↗

Development of a Microwave Regenerative Sorbent-Based Hydrogen Purifier

This paper describes the design and fabrication of a Microwave Regenerative Sorbent-based Hydrogen Purifier (MRSHP). This unique microwave powered technology was developed for the purification of a hydrogen stream produced by the Plasma Pyrolysis Assembly (PPA). The PPA is a hydrogen recovery (from methane) post processor for NASA's Sabatier-based carbon dioxide reduction process. Embodied in the Carbon dioxide Reduction Assembly (CRA), currently aboard the International Space Station (ISS), the Sabatier reaction employs hydrogen to catalytically recover oxygen, in the form of water, from respiratory carbon dioxide produced by the crew. This same approach is base-lined for future service in the Air Revitalization system on extended missions into deep space where resupply is not practical. Accordingly, manned exploration to Mars may only become feasible with further closure of the air loop as afforded by the greater hydrogen recovery permitted by the PPA with subsequent hydrogen purification. By utilizing the well-known high sorbate loading capacity of molecular sieve 13x, coupled with microwave dielectric heating phenomenon, MRSHP technology is employed as a regenerative filter for a contaminated hydrogen gas stream. By design, freshly regenerated molecular sieve 13x contained in the MRSHP will remove contaminants from the effluent of a 1-CM scale PPA for several hours prior to breakthrough. By reversing flow and pulling a relative vacuum the MRSHP prototype then uses 2.45 GHz microwave power, applied through a novel coaxial antenna array, to rapidly heat the sorbent bed and drive off the contaminants in a short duration vacuum/thermal contaminant desorption step. Finally, following rapid cooling via room temperature cold plates, the MRSHP is again ready to serve as a hydrogen filter.

Wheeler, Richard R., Jr.↗

Igniters for Liquid Oxygen/Liquid Methane Technology Development

As part of NASA's technology development of liquid methane / liquid oxygen engines for future exploration missions, two different igniters were recently studied at NASA Marshall Space Flight Center. The first igniter tested was an impinging injection, spark-initiated torch igniter, and the second was a microwave-generated plasma igniter. The purpose of the ignition tests was to define the ignition limits under vacuum conditions and characterize the transient start-up performance as a function of propellant mixture ratio (MR), mass flow rates, inlet temperatures, and pre-ignition chamber pressure. In addition, for the impinging igniter two different spark plugs were tested, and for the microwave igniter the magnetron filament warm-up time and the magnetron input power were both varied. The results gathered from these tests indicated that the impinging igniter is capable of operating over an MR range of 2 - 27, with methane and oxygen inlet temperatures as low as -161 F and -233 F, respectively. The microwave igniter was tested over an MR range of 2 - 9, with methane and oxygen inlet temperatures as low as -90 F and -200 F, respectively. The microwave igniter achieved ignition over this range, although an upper ignition limit was determined for the oxidizer mass flow rate. In general, the torch exhaust temperatures for the microwave igniter were not as high as those attained with the impinging igniter. The microwave igniter, however, was hot-fired 17 times and was still operational, whereas the impinging igniter spark plugs experienced thermal shock and erosion over nine hot-fire tests. It was concluded that for the microwave igniter better mixing of the propellants might be required in order to both raise the torch exhaust temperature and decrease the required magnetron input power, and for the impinging igniter the spark plug position within the igniter chamber should be varied in future tests to identify a more optimal location. All of the igniter tests were supported by the Propulsion & Cryogenics Advanced Development project, which is part of NASA's Exploration Technology Development Program.

Osborne, Robin J.↗

Particle Interaction Physics Model Formulation for Plume-Surface Interaction Erosion and Cratering

As part of the Game Changing Development (GCD) Program, funded by NASA’s Space Technology Mission Directorate (STMD), the development of simulation capability for the prediction of extra-terrestrial Plume Surface Interaction (PSI) environments has been undertaken by the Fluid Dynamics Branch at NASA/MSFC. The Predictive Simulation Capability (PSC) Element is focused on creating simulation capability for the reliable and accurate prediction of PSI in Martian (~650 Pa) and Lunar (vacuum) ambient environments. In addition to the predictive simulation capability, the GCD Program also contains a companion Ground Testing Element for development of focused datasets for validation of predictive capability as well as a Flight-focused Instrumentation Element. This paper will present the status of implementing and maturing particle-particle interaction constituent physics models essential in simulating the landing surface granular material flow under PSI effects. This gas-particle multi-phase interaction modeling of plume impingement flow on the extra-terrestrial soil material is performed with the Gas-Granular Flow Solver (GGFS) addressed in a companion paper. The response of regolith particle flow induced by lander PSI requires accurate representation of the regolith granular material fluidic behavior and gas-granular interactions. The lunar regolith, as the extreme example, is poorly sorted with broad particle size distributions and large fines content. It has significant cohesion, due to interlocking particle shapes for the very jagged particles. The combination of particle shape and size distribution has been identified as major drivers in the complex particle flow response and resulting crater shape characteristics of extraterrestrial granular material. Constituent models for spherical particles can be formulated directly from particle kinetics theory. Complex particle shapes can be modeled by gluing together elemental spherical shapes into composite particles, requiring a Discrete Element Model (DEM) particle kinetics modeling approach to extract data and formulate constituent models. Mixture constituent models for poly-disperse mixtures (i.e, containing distribution of particle sizes) have recently been developed. The required non-spherical particle mixture granular material response closure models are then obtained through small-scale unit physics DEM simulations for the range of particle shapes, mixtures and packing densities. The granular material response closure models are then implemented in the Eulerian granular flow formulation. This DEM-based constituent model extraction process and formulation of poly-disperse particle mixtures has been successfully developed by small business and academic partners in the development of the Gas-Granular Flow Solver (GGFS) simulation program simulation framework. The currently implemented capabilities have reached the capability level of modeling bi-disperse, non-spherical particle mixtures is being continuously extended towards computational modeling of full range irregular particle mixtures. Under the GCD project, this technology is being further developed, transferred to NASA analysts, and matured towards application readiness. The predictive simulation capability team under the GCD project has acquired the modeling tools and processes of the DEM based constituent model formulation from the GGFS development team and is developing the capability to replicate the existing process. This is the first important step towards the ability of the NASA team to independently perform such model development in a production setting. Further efforts are underway to migrate the DEM based model simulation process performed with the academic based tools to more capable Open Source, highly parallelized simulation tools for efficient operation on NASA HPC assets. Evaluation of the currently implemented (such as mono-disperse and bi-disperse spherical and irregular shape particle constituent model applications) and continuously evolving full-range particle physics models in the GGFS tool is performed by the NASA team to advance application readiness of the simulations. Application testing for complex PSI erosions and cratering scenarios such as the Apollo LM is performed for axi-symmetric and full 3D simulations to aid the tool developers in achieving practical application readiness for NASA projects. Important validation and application testing will further be performed against experimental data generated under the GCD PSI project experimental component.

Peter A Liever↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Reactor Simulator Integration and Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator (RxSim) test loop was designed and built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing were to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V because the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This Technical Memorandum summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained, which was lower than the predicted 750 K but 156 K higher than the cold temperature, indicating the design provided some heat regeneration. The annular linear induction pump tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfield, M. P.↗

Preparation for Hollow Cathode Testing for the Advanced Electric Propulsion System at NASA Glenn Research Center

NASA Glenn Research Center is performing activities to support the unique needs of hollow cathode development and testing for the Advanced Electric Propulsion System (AEPS). Three existing vacuum facilities have been outfitted as cathode test facilities, and each will serve a different role in upcoming testing. Vacuum Facility 67 is being developed to serve as a long-duration test facility for the Engineering Development Unit cathode, which is to be delivered by the AEPS contractor. It will feature a thruster-like magnetic field simulator and cold-cycle capability via a liquid nitrogen-cooled cold plate. Vacuum Facility 17 is being developed as a test facility for short- to medium-duration experiments in order to provide auxiliary support for the long-duration testing. It will feature a magnetic field simulator but not cold-cycling. Finally, Vacuum Facility 1 will be a high-pumping speed cathode development environment, and will feature an array of plasma and temperature diagnostics. In addition to the facility preparation work, a new cathode, referred to as the Mark II, has been designed. The Mark II is an evolution of the Technology Demonstration Unit cathodes that better evokes the geometry, fabrication, and construction of the forthcoming Engineering Development Unit. This cathode serves as a transition between the Technology Demonstration Unit cathodes used during early thruster development and the forthcoming Engineering Development Unit cathodes. It will be used as a means of verifying the new test facilities prior to arrival of Engineering Development Unit hardware. Details of the Mark II design and key features are presented, as well as details of future work to be performed.

Hall, Scott J.↗

Preparation for Hollow Cathode Testing for the Advanced Electric Propulsion System at NASA Glenn Research Center

NASA Glenn Research Center is performing activities to support the unique needs of hollow cathode development and testing for the Advanced Electric Propulsion System (AEPS). Three existing vacuum facilities have been outfitted as cathode test facilities, and each will serve a different role in upcoming testing. Vacuum Facility 67 is being developed to serve as a long-duration test facility for the Engineering Development Unit cathode, which is to be delivered by the AEPS contractor. It will feature a thruster-like magnetic field simulator and cold-cycle capability via a liquid nitrogen-cooled cold plate. Vacuum Facility 17 is being developed as a test facility for short- to medium-duration experiments in order to provide auxiliary support for the long-duration testing. It will feature a magnetic field simulator but not cold-cycling. Finally, Vacuum Facility 1 will be a high-pumping speed cathode development environment, and will feature an array of plasma and temperature diagnostics. In addition to the facility preparation work, a new cathode, referred to as the Mark II, has been designed. The Mark II is an evolution of the Technology Demonstration Unit cathodes that better evokes the geometry, fabrication, and construction of the forthcoming Engineering Development Unit. This cathode serves as a transition between the Technology Demonstration Unit cathodes used during early thruster development and the forthcoming Engineering Development Unit cathodes. It will be used as a means of verifying the new test facilities prior to arrival of Engineering Development Unit hardware. Details of the Mark II design and key features are presented, as well as details of future work to be performed.

Hall, Scott J.↗

Hydrogen Sensors Demonstrated on the Shuttle

Microelectromechanical-systems- (MEMS-) based hydrogen sensor technology developed by the NASA Glenn Research Center at Lewis Field and Case Western Reserve University was demonstrated on shuttle missions STS-95 (Senator Glenn s mission) and STS-96. These smart sensors, commercialized by Makel Engineering Inc., were part of an "Integrated Vehicle Health Monitoring HEDS Technology Demonstration" series conducted at the NASA Kennedy Space Center. The experiments were designed to demonstrate the effect of technological upgrades on shuttle performance. The hydrogen sensors were micro-fabricated for minimal size, weight, and power consumption. A temperature detector and heater were included on the sensor for temperature control. Two palladium chrome (PdCr) hydrogen detection devices were included in each sensor package: a Schottky diode for low concentrations and a resistor for high concentrations. These sensor designs allow operation in inert environments. "Smart" electronics developed by Makel Engineering were integrated with the sensors to control the sensor temperature and process the output of the various sensors. This complete hydrogen detection system (two sensors on a chip with smart electronics) flew on STS-95 (launched October 1998) and STS-96 (launched May 1999). It was installed in the aft compartment of the shuttle and used to monitor the hydrogen concentration in that region. Up to this time, a mass spectrometer had monitored the hydrogen concentration in the aft compartment before launch, and "grab" bottles had been used after launch. The inside of these bottles is at vacuum. During flight, the grab bottles are pyrotechnically opened for a brief period, and the gas in the aft compartment is captured in the bottle. Several of these bottles are opened at different times during takeoff, and their contents are used to determine the time profile of the gases in the aft chamber. However, this information is not available until after the flight. On the launch pad, results from the new sensor technology paralleled the responses of the mass spectrometer with, in some cases, a quicker response time. In flight, data from the new sensors agreed with those derived from analyzing the contents of the grab bottles. Moreover, this microsensor can monitor the aft compartment continuously and, in principle, could monitor the health of the vehicle in real time during flight.

Hunter, Gary W.↗

Automated Fabrication Technologies for High Performance Polymer Composites

New fabrication technologies are being exploited for building high graphite-fiber-reinforced composite structure. Stitched fiber preforms and resin film infusion have been successfully demonstrated for large, composite wing structures. Other automatic processes being developed include automated placement of tacky, drapable epoxy towpreg, automated heated head placement of consolidated ribbon/tape, and vacuum-assisted resin transfer molding. These methods have the potential to yield low cost high performance structures by fabricating composite structures to net shape out-of-autoclave.

Shuart , M. J.↗

Cryogenic Boil-Off Reduction System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to the high specific impulse that can be achieved using engines suitable for moving 10's to 100's of metric tons of payload mass to destinations outside of low earth orbit. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several days. The losses can be greatly reduced by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and by the integration of self-supporting multi-layer insulation. The active thermal control technology under development is the integration of the reverse turbo- Brayton cycle cryocooler to the propellant tank through a distributed cooling network of tubes coupled to a shield in the tank insulation and to the tank wall itself. Also, the self-supporting insulation technology was utilized under the shield to obtain needed tank applied LH2 performance. These elements were recently tested at NASA Glenn Research Center in a series of three tests, two that reduced LH2 boil-off and one to eliminate LO2 boil-off. This test series was conducted in a vacuum chamber that replicated the vacuum of space and the temperatures of low Earth orbit. The test results show that LH2 boil-off was reduced 60% by the cryocooler system operating at 90K and that robust LO2 zero boil-off storage, including full tank pressure control was achieved.

Propellant Storage↗

In-Situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical non-contact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

In-situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical noncontact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

In-Situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical non-contact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

Relevant Environment Additive Construction Technology (REACT)

Project Overview This project is focused on developing technologies that enable construction of a Lunar Safe Haven type structure on the moon. A full scale architectural and structural design will be completed based on lunar conditions and Artemis mission needs. A scaled structure will be 3D printed in simulated lunar environments. Technical Approach Polymer bound regolith composite materials will be developed and characterized for lunar additive construction applications. A full scale architectural and structural design will be completed based on the latest scientific data on lunar environments including radiation, meteoroids, thermal conditions, reduced gravity, and moonquakes. The project will culminate with a demonstration of additive construction in simulated lunar vacuum, thermal, regolith, and UV conditions. Results/Summary Preliminary material specifications have been developed and an initial batch has been produced. A first iteration of the architectural and structural designs have been completed. Hardware for 3D printing in simulated lunar conditions is under development. Contributing Partners AI Space Factory – Winner of the NASA 3D Printed Habitat Centennial Challenge Infusion and Transition Plan On-surface construction of infrastructure is a critical capability of the sustainable phase of the Artemis Program and eventual sustainable human presence on Mars. It provides the ability to create protective shelters on-demand using local resources. The 3D-printing technology will achieve TRL 6 in 1g/vacuum tests with thermal/UV exposure in this project. CLPS missions will be pursued for infusion to demonstrate vertical construction with lunar regolith and conditions. Modeling and simulation will be used to define the pilot-scale shelter construction mission for long-term exposure on the lunar surface to validate the system for Artemis operational deployment.

Lunar Construction↗

Technology Transferred to the Kirby Company

NASA Lewis Research Center's Propulsion Systems Branch, evaluated the structural and vibration characteristics of the Kirby Model G-4 fan. Modes of vibration and resonance potential were evaluated in the Holography Test Lab at Lewis. As a result of the Lewis tests and rotor structural evaluation, Kirby engineers gained new insights into their existing design, enabling them to develop a more robust fan for use in their vacuum cleaners.

Source record↗

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that produce very high extinction ratios in the FUV spectral range (100-200 nm). This polarizer consists of reflecting light through a series of mirrors from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the average LiF Brewster’s angle in the FUV. The output is a highly linearly polarized beam. This polarizer concept was fabricated and tested in the existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing using a MgF2 crystal at the Brewster’s angle as an analyzer has shown that this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm, and that the measured extinction ratio of the two crossed polarizers, ≈114, is mostly limited by the MgF2 analyzer. A polarizer with such a performance at this wavelength has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the polarizer’s compact design allows for a new polarizer capability that would one day be implemented in a future FUV spectropolarimetry space mission.

Far Ultraviolet (FUV)↗

Determination of contamination character of materials in space technology testing

The contamination character of selected materials used in space technology testing is presented. Many of these materials contain components that become volatile in a space environment. Most previous data were limited to weight loss or vapor pressure. However, these parameters are not necessarily a direct measure of the contamination character of these materials. Selected materials were exposed to a thermal-vacuum environment, and the degree of contamination was measured by collecting the outgases from these materials on a cold test mirror surface. The degradation of reflectivity of the mirror was measured over a spectral range from 1100 A to 2.5 microns. Half the mirror's surface was also exposed to UV irradiation to determine its effects on the contaminative character of the depositing outgases. The amount of deposit per unit area was measured by microbalances mounted near the mirror; the sensor of one microbalance was UV irradiated. A quadrupole mass spectrometer was used to determine the composition of the outgases.

Haynes, D. L.↗