Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Measuring the thermal conductivity of hydrogels with a bidirectional 3w method

Hydrogels are soft, water-absorbing polymer materials with diverse applications in biomedicine and agriculture. Recently, hydrogels have been proposed to encapsulate water-soluble phase change materials which store energy in their latent heat of solidification. In these applications, the thermal conductivity of these materials affects their performance. Few methods exist for measuring the thermal conductivity of small quantities of hydrogels. Here, we describe an implementation of the bidirectional 3w technique to measure the thermal conductivity of hydrogels with particular attention to their moisture content. Our implementation of the technique can probe sample volumes as little as ~20 mL and yields the thermal conductivity without requiring fitting of additional thermal parameters. We numerically simulate 3w sensor designs with frequency-domain 3-D models to quantify and reduce errors introduced by the choice of substrate and insulation layer thickness. Frequencies in the ~1−20 Hz range yield less error for the materials considered here. We verify our setup with measurements on water and report values for polyacrylamide and poly(2-acrylamido-2-methylpropane sulfonic acid) (PAMPS) hydrogels. Our swollen hydrogels exhibited thermal conductivities nearly equivalent to water, 0.6 W m-1 K-1, and we estimate thermal conductivities of 0.43 and 0.42 W m-1 K-1 for neat polyacrylamide and PAMPS, respectively. Finally, we estimate an error of ±7%, consistent with other 3ω methods, with the largest error coming from the sensor calibration. We find our implementation of the bidirectional 3w method gives reasonable results and can be employed for prototyping soft materials relevant for thermal storage.

3-omega, thermal conductivity, hydrogel, moisture ↗

Applications and Results of MODIS Lunar Observations

Both Terra and Aqua MODIS have been making periodic lunar observations since their launch in December 1999 and May 2002, respectively. The primary objective of the MODIS lunar observations is to monitor on-orbit response changes for the reflective solar bands (RSB) and to track long-term radiometric calibration stability. The Moon is an extremely stable surface reflectance reference and, together with the lunar radiometric model developed recently by the US Geological Survey (USGS), the applications of lunar observations for Earth remote sensing missions have been greatly enhanced and expanded. In particular, calibration inter-comparisons among sensors on different platforms and operated in different time frames have been enabled in the VIS/NIR/SWIR spectral regions. In this paper, we discuss various applications of MODIS lunar observations, such as monitoring the RSB radiometric stability and calibration consistency between the two sensors, evaluating the calibration differences among detectors within the same spectral band, and tracking the on-orbit changes of band-to-band registration (BBR). Other applications designed for the thermal emissive bands (TEB) and special sensor characterization purposes are also illustrated. Results from multi-year Terra and Aqua MODIS lunar observations demonstrate clearly that the two sensors have been calibrated consistently to within 1% for most RSB compared to the 2% radiometric calibration requirement. In addition the spatial characterization results derived from lunar observations are in good agreement with those derived from the instrument's on-board calibrator. The applications and results of MODIS lunar observations presented in this paper provide useful references for other sensors that also make use of lunar surface observations.

Xiong, X.↗

Temperature averaging thermal probe

A thermal probe to average temperature fluctuations over a prolonged period was formed with a temperature sensor embedded inside a solid object of a thermally conducting material. The solid object is held in a position equidistantly spaced apart from the interior surfaces of a closed housing by a mount made of a thermally insulating material. The housing is sealed to trap a vacuum or mass of air inside and thereby prevent transfer of heat directly between the environment outside of the housing and the solid object. Electrical leads couple the temperature sensor with a connector on the outside of the housing. Other solid objects of different sizes and materials may be substituted for the cylindrically-shaped object to vary the time constant of the probe.

Kalil, L. F.↗

Rotating gravity gradiometer study

Two rotating gravity gradiometer (RGG) sensors, along with all the external electronics needed to operate them, and the fixtures and special test equipment needed to fill and align the bearings, were assembled in a laboratory, and inspected. The thermal noise threshold of the RGG can be lowered by replacing a damping resistor in the first stage electronics by an active artificial resistor that generates less random voltage noise per unit bandwidth than the Johnson noise from the resistor it replaces. The artificial resistor circuit consists of an operational amplifier, three resistors, and a small DC to DC floating power supply. These are small enough to be retrofitted to the present circuit boards inside the RGG rotor in place of the 3 Megohm resistor. Using the artificial resistor, the thermal noise of the RGG-2 sensor can be lowered from 0.3 Eotvos to 0.15 Eotvos for a 10 sec integration time.

Forward, R. L.↗

Laboratory Evaluation of the Thermal Breakout Method for Maximum Horizontal Stress Measurement

Measuring in situ stress is essential for many problems in geomechanics, and the maximum horizontal stress is the most difficult to constrain. We are developing an extension of the breakout method to measure maximum horizontal stress in regions where natural breakouts do not occur. In the novel thermal breakout method, additional compression which leads to breakout development is induced by heating the borehole wall. In the present study, we validated the method experimentally in a true-triaxial apparatus on samples with predrilled boreholes. Two rocks were selected for laboratory testing: high-porosity Berea sandstone and low-porosity Niagaran dolomite. Prior to main true-triaxial tests, we carried out standard testing to characterize the strength, elasticity and thermal properties. The true-triaxial experiments consisted of: (1) room-temperature tests where samples were first loaded mechanically until the breakout formed, and (2) elevated-temperature tests where samples were loaded mechanically within the elastic range with additional compression induced thermally. Breakout initiation was monitored by acoustic emission sensors mounted on the pistons that applied horizontal stresses. Furthermore, the magnitude of induced thermal stress was calculated from temperature measurements around the borehole wall. In both rock types, we created thermally induced breakouts and examined analytical expressions to constrain maximum horizontal stress based on strength, elastic and thermal properties of the rocks.

58 GEOSCIENCES↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device for the George C. Marshall Space Flight Center

The development and testing of a temperature sensor and pulse duration modulation (PDM) diverter valve for a thermal control-mixing control device are described. The temperature sensor selected for use uses a fluidic pin amplifier in conjunction with an expansion device. This device can sense changes of less than 0.25 F with greater than 15:1 signal to noise ratio when operating with a typical Freon pump supplied pressure. The pressure sensitivity of the sensor is approximately 0.0019 F/kPa. The valve which was selected was tested and performed with 100% flow diversion. In addition, the valve operates with a flow efficiency of at least 95%, with the possibility of attaining 100% if the vent flow of the PDM can be channeled through the last stage of the diverter valve. A temperature sensor which utilized an orifice bridge circuit and proportional-vortex combination mixing valve were also evaluated, but the concepts were rejected due to various problems.

Thurston, T. S.↗

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Thermal Distortion Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope consisting of an Optical telescope element (OTE), Integrated science instrument module (ISIM), a Spacecraft, and a Sunshield. The Integrated Science Instrument Module (ISIM) consists of the JWST science instruments (NIRCam, MIRI, NIRSpec), a fine guidance sensor (FGS), the ISIM Structure, and thermal and electrical subsystems. JWST's instruments are designed to work primarily in the infrared range of the electromagnetic spectrum, and the instruments and telescope operate at cryogenic temperatures (approximately 35 K for the instruments).

Johnston, John↗

Nanostructure Engineered Chemical Sensors for Hazardous Gas and Vapor Detection

A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxides nanowires or nanobelts, on a pair of interdigitated electrodes (IDE) processed with a silicon based microfabrication and micromachining technique. The IDE fingers were fabricated using thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to hazardous gases and vapors, such as acetone, benzene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing in our sensor platform can be understood by electron modulation between the nanostructure engineered device and gas molecules. As a result of the electron modulation, the conductance of nanodevice will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost.

Li, Jing↗

An Overview of Thermal Distortion Modeling, Analysis, and Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope consisting of the following elements: (1) Optical telescope element (OTE) (2) Integrated science instrument module (ISIM) (3) Spacecraft (4) Sunshield The Integrated Science Instrument Module (ISIM) consists of the JWST science instruments (NIRCam, MIRI, NIRSpec), a fine guidance sensor (FGS), the ISIM Structure, and thermal and electrical subsystems. JWST's instruments are designed to work primarily in the infrared range of the electromagnetic spectrum, and the instruments and telescope operate at cryogenic temperatures (approximately 35 K for the instruments). The development and validation of a thermal distortion modeling and analysis capability for the JWST ISIM Structure was successfully completed. The modeling and analysis approach was grounded in initial constituent materials testing and benchmarked to test results at the composite bonded joint, subassembly, and fullscale flight hardware levels. Comparison of analysis predictions and test results from this series of incremental cryogenic thermal distortion tests demonstrates that the model validation goals are achieved.

Johnston, John↗

NASA's Photon-Counting SLR2000 Satellite Laser Ranging System: Progress and Applications

NASA's new unmanned SLR2000 system is designed to track, with millimeter precision and using single photon returns, a constellation of roughly 24 retroreflector-equipped satellites, which range in altitude from about 300 km to 20,000 km. Totally autonomous operation and a common engineering configuration are expected to greatly reduce station operations costs relative to NASA's current manned systems. The system has also been designed with a goal of significantly lowering replication costs. All of the prototype components and subsystems have been completed and tested and have substantially met the original specifications. The prototype system is presently undergoing final integration and testing in a dedicated shelter with an azimuth tracking dome synchronized to the optical tracking mount. The facility also features a number of security features such as security cameras and sensors designed to detect power or thermal control problems or entry by unauthorized personnel. Field tests are in progress. The present paper provides an overview of the various subsystems and test results to date. The meteorological subsystem, which has operated successfully in the field for almost three years, consists of several sensors which measure: (1) pressure, temperature, and relative humidity; (2) wind speed and direction; (3) ground visibility and precipitation; and (4) local cloud cover as a function of station azimuth and elevation (day and night). A "pseudo-operator" software program interprets the sensor readings and modifies satellite tracking priorities based on local meteorological conditions.

Degnan, John J.↗

An Inventory of Impact Craters on the Martian South Polar Layered Deposits

The polar layered deposits (PLD) of Mars continue to be a focus of study due to the possibility that these finely layered, volatile-rich deposits hold a record of recent eras in Martian climate history. Recently, the visible sensor on 2001 Mars Odyssey s Thermal Emission Imaging System (THEMIS) has acquired 36 meter/pixel contiguous single-band visible image data sets of both the north and the south polar layered deposits, during the local spring and summer seasons. In addition, significant coverage has been obtained at the THEMIS visible sensor s full resolution of 18 meters/pixel. This paper reports on the use of these data sets to further characterize the population of impact craters on the south polar layered deposits (SPLD), and the implications of the observed population for the age and evolution of the SPLD.

Plaut, J. J.↗

Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series

Abstract. Improving the quantification of soil thermal and physical properties is key to achieving a better understanding and prediction of soil hydro-biogeochemical processes and their responses to changes in atmospheric forcing. Obtaining such information at numerous locations and/or over time with conventional soil sampling is challenging. The increasing availability of low-cost, vertically resolved temperature sensor arrays offers promise for improving the estimation of soil thermal properties from temperature time series, and the possible indirect estimation of physical properties. Still, the reliability and limitations of such an approach need to be assessed. In the present study, we develop a parameter estimation approach based on a combination of thermal modeling, sliding time windows, Bayesian inference, and Markov chain Monte Carlo simulation to estimate thermal diffusivity and its uncertainty over time, at numerous locations and at an unprecedented vertical spatial resolution (i.e., down to 5 to 10 cm vertical resolution) from soil temperature time series. We provide the necessary framework to assess under which environmental conditions (soil temperature gradient, fluctuations, and trend), temperature sensor characteristics (bias and level of noise), and deployment geometries (sensor number and position) soil thermal diffusivity can be reliably inferred. We validate the method with synthetic experiments and field studies. The synthetic experiments show that in the presence of median diurnal fluctuations ≥ 1.5 ∘C at 5 cm below the ground surface, temperature gradients > 2 ∘C m−1, and a sliding time window of at least 4 d the proposed method provides reliable depth-resolved thermal diffusivity estimates with percentage errors ≤ 10 % and posterior relative standard deviations ≤ 5 % up to 1 m depth. Reliable thermal diffusivity under such environmental conditions also requires temperature sensors to be spaced precisely (with accuracy to a few millimeters), with a level of noise ≤ 0.02 ∘C, and with a bias defined by a standard deviation ≤ 0.01 ∘C. Finally, the application of the developed approach to field data indicates significant repeatability in results and similarity with independent measurements, as well as promise in using a sliding time window to estimate temporal changes in soil thermal diffusivity, as needed to potentially capture changes in bulk density or water content.

54 ENVIRONMENTAL SCIENCES↗

Arrays of High Performance Thermal Detectors

Thermal detectors have historically been the sensors of choice for applications where photoconductive or photovoltaic detectors are unavailable. While they have the advantage of broad wavelength coverage, a primary disadvantage has been sensitivity; at a given operating temperature, bolometers are typically much less sensitive than photodetectors. The development of cryogenic bolometers has resulted in thermal detectors which can reach fundamental sensitivity limits. When operated at temperatures below 0.3 K these devices can provide background-limited sensitivity for cryogenic imaging and spectroscopy in space. The past decade has seen a rapid growth in sensitivity and array format in cryogenic bolometers. Micromachining technology, combined with advances in superconducting electronics, provides a strong technological base for future developments. I will describe the present state of development of low-temperature thermal detectors, and the possible extension of this technology to higher temperature operation.

Moseley, Harvey↗

Total Temperature Measurements Using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

Engine Icing Performance loss: rollback, surge, flameout, and even internal engine damagePartial melting and refreeze of ice inside engine core (Mason et al., 2006). Ingestion of ice crystals and aggregates, mixed-phase droplets, or supercooled liquid dropletsNeed to better understand the conditions and properties that lead to engine icing.Simulation and analysis (physical and computational, and modeling)Test facilities (PSL, NRC, ...). Thermal and computational models and analysisProbesMultiple probes (aerothermal probes and ice cloud characterization probes and techniques). Total temperatureTraditional total temperature probes (vented forward facing)Heated total temperature probes (Goodyear). Rearward facing (developmental). Total temperature relevance. Thermal interaction between the icing cloud and air flow impinging particles contribute to kinetic heating effect (Gent et al., 2000). Measurement considerations Temperature sensor accuracy. Incomplete recovery of total temperature. Thermal surfaces (sources and sinks). Flow effects (viscous losses). Debris contamination, including icing and ice ingestion.

Agui, Juan H.↗

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.↗