Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

SU-F-T-574: MLC Based SRS Beam Commissioning - Minimum Target Size Investigation

Purpose: To implement a MLC accelerator based SRS program using small fields down to 1 cm × 1 cm and to determine the smallest target size safe for clinical treatment. Methods: Computerized beam scanning was performed in water using a diode detector and a linac-head attached transmission ion chamber to characterize the small field dosimetric aspects of a 6 MV photon beam (Trilogy-Varian Medical Systems, Inc.). The output factors, PDD and profiles of field sizes 1, 2, 3, 4, and 10 cm{sup 2} were measured and utilized to create a new treatment planning system (TPS) model (AAA ver 11021). Static MLC SRS treatment plans were created and delivered to a homogeneous phantom (Cube 20, CIRS, Inc.) for a 1.0 cm and 1.5 cm “PTV” target. A 12 field DMLC plan was created for a 2.1 cm target. Radiochromic film (EBT3, Ashland Inc.) was used to measure the planar dose in the axial, coronal and sagittal planes. A micro ion chamber (0.007 cc) was used to measure the dose at isocenter for each treatment delivery. Results: The new TPS model was validated by using a tolerance criteria of 2% dose and 2 mm distance to agreement. For fields ≤ 3 cm{sup 2}, the max PDD, Profile and OF difference was 0.9%, 2%/2mm and 1.4% respectively. The measured radiochromic film planar dose distributions had gamma scores of 95.3% or higher using a 3%/2mm criteria. Ion chamber measurements for all 3 test plans effectively met our goal of delivering the dose accurately to within 5% when compared to the expected dose reported by the TPS (1 cm plan Δ= −5.2%, 1.5 cm plan Δ= −2.0%, 2 cm plan Δ= 1.5%). Conclusion: End to end testing confirmed that MLC defined SRS for target sizes ≥ 1.0 cm can be safely planned and delivered.

07 ISOTOPE AND RADIATION SOURCES↗

Fort Nelson Test Site - Site Characterization Report

The Plains CO 2 Reduction (PCOR) Partnership, led by the Energy & Environmental Research Center (EERC), is working with Spectra Energy Transmission (SET) to determine the feasibility of large-scale injection of carbon dioxide (CO 2 ) into a deep brine-saturated carbonate formation near Fort Nelson, British Columbia, Canada, for the purpose of CO 2 storage. Site characterization must be conducted prior to large-scale injection of CO 2 at the Fort Nelson test site. Effective characterization supports modeling; risk assessment; and monitoring, verification, and accounting (MVA) programs that will constantly evolve to suit the project’s needs. Site characterization activities have been conducted to address three critical issues affecting the viability of the Fort Nelson test site: 1) the capacity of the target formation, 2) injectivity, and 3) containment – the potential for leakage of the injected CO 2 into overlying formations and/or the near-surface environment. Geochemical, mineralogical/petrophysical, geomechanical, and hydrogeological data have been collected for the purpose of supporting modeling, risk assessment, and MVA activities. The geology, stratigraphy, and lithology have been evaluated, delineated, and described for the entire sedimentary succession from the base of the Devonian age Presqu’ile reef complex to the top of the Fort Simpson shale (cap rock) in the Fort Nelson project area. The structural elements of the reef complex have been investigated to identify any existing faults and/or fractures that would allow migration of any reservoir and/or injected fluids out of the storage reservoir. On this basis, a geologic model has been built, with particular attention given to the Devonian injection interval and overlying and underlying sealing formations.

54 ENVIRONMENTAL SCIENCES↗

Understanding Contamination; Twenty Years of Simulating Radiological Contamination

A wide variety of simulated contamination methods have been developed by researchers to reproducibly test radiological decontamination methods. Some twenty years ago a method of non-radioactive contamination simulation was proposed at the Idaho National Laboratory (INL) that mimicked the character of radioactive cesium and zirconium contamination on stainless steel. It involved baking the contamination into the surface of the stainless steel in order to 'fix' it into a tenacious, tightly bound oxide layer. This type of contamination was particularly applicable to nuclear processing facilities (and nuclear reactors) where oxide growth and exchange of radioactive materials within the oxide layer became the predominant model for material/contaminant interaction. Additional simulation methods and their empirically derived basis (from a nuclear fuel reprocessing facility) are discussed. In the last ten years the INL, working with the Defense Advanced Research Projects Agency (DARPA) and the National Homeland Security Research Center (NHSRC), has continued to develop contamination simulation methodologies. The most notable of these newer methodologies was developed to compare the efficacy of different decontamination technologies against radiological dispersal device (RDD, 'dirty bomb') type of contamination. There are many different scenarios for how RDD contamination may be spread, but the most commonly used one at the INL involves the dispersal of an aqueous solution containing radioactive Cs-137. This method was chosen during the DARPA projects and has continued through the NHSRC series of decontamination trials and also gives a tenacious 'fixed' contamination. Much has been learned about the interaction of cesium contamination with building materials, particularly concrete, throughout these tests. The effects of porosity, cation-exchange capacity of the material and the amount of dirt and debris on the surface are very important factors. The interaction of the contaminant/substrate with the particular decontamination technology is also very important. Results of decontamination testing from hundreds of contaminated coupons have lead to certain conclusions about the contamination and the type of decontamination methods being deployed. A recent addition to the DARPA initiated methodology simulates the deposition of nuclear fallout. This contamination differs from previous tests in that it has been developed and validated purely to simulate a 'loose' type of contamination. This may represent the first time that a radiologically contaminated 'fallout' stimulant has been developed to reproducibly test decontamination methods. While no contaminant/methodology may serve as a complete example of all aspects that could be seen in the field, the study of this family of simulation methods provides insight into the nature of radiological contamination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.

60 APPLIED LIFE SCIENCES↗

Alignment of the Near Detector scintillator modules using cosmic ray muons

The authors describe the procedures and the results of the first alignment of the Near Detector. Using 15.5 million cosmic ray muon tracks, collected from October, 2004 through early january, 2005, they derive the effective transverse positions of the calorimeter scintillator modules. The residuals from straight line fits indicate that the current alignment has achieved better than 1 mm precision. They estimate the size of the remaining misalignment and using tracks recorded with a magnetic field test the effect of the magnetic field on the alignment.

43 PARTICLE ACCELERATORS↗

Activated carbon supported Ni, Fe, and bimetallic NiFe catalysts for CO x -free H 2 production by microwave methane pyrolysis

The goal of this study was to test the effect of metal-impregnated carbon-based catalysts on the conversion of methane to hydrogen gas and solid carbon using microwave reactor technology. Monometallic and bimetallic catalysts on activated carbon supports (Ni/AC, Fe/AC, Ni-Fe/AC) are compared during methane pyrolysis testing. Catalytic methane pyrolysis was carried out in a microwave reactor at reaction temperatures of 600 °C and 800 °C. For comparison, one of the catalysts (Ni-Fe/AC) was tested in a conventionally heated reactor at 800 °C. The prepared catalysts were characterized by X-ray diffraction (XRD), while post-reaction catalysts were characterized by XRD and SEM. During reaction testing, the monometallic Ni/AC catalyst exhibited the best catalytic activity (CH 4 conversion: 46.0 and H 2 yield: 46.9%) when reacted in the microwave reactor, however, it suffered from rapid deactivation from carbon deposition (carbon yield: 0.39 gC/g catalyst). The bimetallic Ni-Fe/AC catalyst was slightly less active (CH 4 conversion: 36.9 and H 2 yield: 40.5%) but it was more resistant to carbon formation (carbon yield: 0.27 gC/g catalyst) suggesting it may have greater long-term stability. The Ni-Fe/AC catalyst was also the most energy efficient as it required the least microwave power to maintain the 800 °C reaction temperature compared to the other catalysts tested. Methane conversion of the bimetallic Ni-Fe/AC at 800 °C under microwave irradiation was three times the conversion under conventional heating at the same reaction temperature. Finally, this work demonstrates the use of microwave-specific catalysts for catalytic methane pyrolysis in a microwave reactor, and can be used as a foundation for further methane pyrolysis process and catalyst optimization for CO x -free H 2 production.

08 HYDROGEN↗

Modeling sequential context effects in diagnostic interpretation of screening mammograms

Prior research has shown that physicians’ medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist’s visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist’s current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski–Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists’ current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about previous perceptual behavior and diagnostic decisions.

60 APPLIED LIFE SCIENCES↗

Wholesale Electricity Analysis via Simulation & Learning Experiments (WEASLE): Platform Development and Pilot Competition

This document reports the development of the Wholesale Electricity Analysis via Simulation and Learning Experiments (WEASLE) platform and the pilot competition that was conducted to test the platform. Due to the increasing reliance on variable renewable energy resources for bulk power, the pilot competition, called the Energy Storage Participation Algorithm Competition (ESPA-Comp), was used to test the effect of various market designs on storage utilization and market efficiency. Basic details of the platform are provided, including an overview of the market clearing engine, the battery dispatch and degradation models, electric grid topology and resource mix, and software architecture. Two market designs were tested: a two-settlement market analogous to typical ISO design today, and a multi-settlement market that allows additional forward-trading periods during the real-time market. Results from the pilot competition show that the storage bidding problem is nontrivial and is well suited for future challenges. We find that: 1) all four teams utilized different approaches to the bidding problem, 2) different methodological approaches led to substantially different offer behaviors, 3) resource profits are clustered by team and methodological approach, 4) simulated offers reduced market surplus by about 0.5%, 5) substantially different prices between two-settlement and multi-settlement markets albeit minimal difference in overall market surplus.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reactor Testing and Qualification: Prioritized High-level Criticality Testing Needs

Researchers at the Idaho National Laboratory (INL) were tasked with reviewing possible criticality testing needs to support development of the fission surface power system reactor design. Reactor physics testing can provide significant information to aid in development of technologies associated with small, fast spectrum reactors that could be applied for non-terrestrial power systems, leading to eventual system qualification. Several studies have been conducted in recent years to assess the data and analyses required to design and build a space fission power system with high confidence that the system will perform as designed [Marcille, 2004a, 2004b; Weaver, 2007; Parry et al., 2008]. This report will provide a summary of previous critical tests and physics measurements that are potentially applicable to the current reactor design (both those that have been benchmarked and those not yet benchmarked), summarize recent studies of potential nuclear testing needs for space reactor development and their applicability to the current baseline fission surface power (FSP) system design, and provide an overview of a suite of tests (separate effects, sub-critical or critical) that could fill in the information database to improve the accuracy of physics modeling efforts as the FSP design is refined. Some recommendations for tasks that could be completed in the near term are also included. Specific recommendations on critical test configurations will be reserved until after the sensitivity analyses being conducted by Los Alamos National Laboratory (LANL) are completed (due August 2011).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Uncertainty and Material Property "Truth" Models and Results for Cantilever Beam End-to-End UQ Problem

Construction of a test problem that quantitatively tests the effectiveness and robustness of the many features and capabilities that a comprehensive E2E UQ framework should have is very challenging. Accordingly, this report illustrates many of the considerations and numerical investigations that went into the construction of the Sandia Cantilever Beam End-to-End UQ test problem.

36 MATERIALS SCIENCE↗

THE SOLAR ABUNDANCE PROBLEM: THE EFFECT OF THE TURBULENT KINETIC FLUX ON THE SOLAR ENVELOPE MODEL

Recent three-dimensional (3D) simulations have shown that the turbulent kinetic flux (TKF) is significant. We discuss the effects of TKF on the size of the convection zone and find that the TKF may help solve the solar abundance problem. The solar abundance problem is that, with new abundances, the solar convection zone depth, the sound speed in the radiative interior, the helium abundance, and the density in the convective envelope are not in agreement with helioseismic inversions. We have performed Monte Carlo simulations on solar convective envelope models with different profiles of TKF to test its effects. The solar abundance problem is revealed in the standard solar convective envelope model with AGSS09 composition, which shows significant differences (∼10)) in density from the helioseismic inversions, but the differences in the model with the old composition GN93 is small (∼0.5)). In the testing models with a different TKF imposed, it is found that the density profile is sensitive to the value of TKF at the base of the convective envelope and insensitive to the structure of TKF in the convection zone. The required value of turbulent kinetic luminosity at the base is about –13% to – 19% L {sub ☉}. Comparing with the 3D simulations, this value is plausible. This study is for the solar convective envelope only. Evolutionary solar models with TKF are required to investigat the effects of TKF on the solar interior structure below the convection zone and the whole solar abundance problem, but the profile of the TKF in the overshoot region is necessary.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel class of broad-spectrum active-site-directed 3C-like protease inhibitors with nanomolar antiviral activity against highly immune-evasive SARS-CoV-2 Omicron subvariants

Antivirals with broad coronavirus activity are important for treating high-risk individuals exposed to the constantly evolving SARS-CoV-2 variants of concern (VOCs) as well as emerging drug-resistant variants. We developed and characterized a novel class of active-site-directed 3-chymotrypsin-like protease (3CLpro) inhibitors (C2-C5a). Our lead direct-acting antiviral (DAA), C5a, is a non-covalent, non-peptide with a dissociation constant of 170 nM against recombinant SARS-CoV-2 3CLpro. The compounds C2-C5a exhibit broad-spectrum activity against Omicron subvariants (BA.5, BQ.1.1, and XBB.1.5) and seasonal human coronavirus-229E infection in human cells. Notably, C5a has median effective concentrations of 30-50 nM against BQ.1.1 and XBB.1.5 in two different human cell lines. X-ray crystallography has confirmed the unique binding modes of C2-C5a to the 3CLpro, which can limit virus cross-resistance to emerging Paxlovid-resistant variants. We tested the effect of C5a with two of our newly discovered host-directed antivirals (HDAs): N-0385, a TMPRSS2 inhibitor, and bafilomycin D (BafD), a human vacuolar H+-ATPase [V-ATPase] inhibitor. We demonstrated a synergistic action of C5a in combination with N-0385 and BafD against Omicron BA.5 infection in human Calu-3 lung cells. Our findings underscore that a SARS-CoV-2 multi-targeted treatment for circulating Omicron subvariants based on DAAs (C5a) and HDAs (N-0385 or BafD) can lead to therapeutic benefits by enhancing treatment efficacy. Furthermore, the high-resolution structures of SARS-CoV-2 3CLpro in complex with C2-C5a will facilitate future rational optimization of our novel broad-spectrum active-site-directed 3C-like protease inhibitors.

3CLpro inhibitor↗

A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry

Purpose: The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along thex axis, the axis parallel to the elongated light source. At constant dose, the measured optical densitiy profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. Methods: For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along thex axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. Results: The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at positionx into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the scanner bed with 2D dose distributions of an open square photon field and an IMRT distribution. Conclusions: The algorithm presented in this study quantifies and corrects the parabola effect of EBT3 films scanned in commonly used commercial flatbed scanners at doses up to 5.2 Gy. It is easy to implement, and no additional work steps are necessary in daily routine film dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of polymer-based water conditioners for reduction of handling-related injury

Fish are coated with an external layer of protective mucus. This layer serves as the primary barrier against infection or injury, reduces friction, and plays a role in ionic and osmotic regulation. However, the mucus layer is easily disturbed when fish are netted, handled, transported, stressed, or subjected to adverse water conditions. Water additives containing polyvinylpyrrolidone (PVP) or proprietary polymers have been used to prevent the deleterious effects of mucus layer disturbances in the commercial tropical fish industry, aquaculture, and for other fisheries management purposes. This paper reviews research on the effectiveness of water conditioners, and examines the contents and uses of a wide variety of commercially available water conditioners. Water conditioners containing polymers may reduce external damage to fish held in containers during scientific experimentation, including surgical implantation of electronic tags. However, there is a need to empirically test the effectiveness of water conditioners at preventing damage to and promoting healing of the mucus layer. A research agenda is provided to advance the science related to the use of water conditions to improve the condition of fish during handling and tagging.

09 BIOMASS FUELS↗

Quantum computation for early universe cosmology

With the emergence of quantum computing we can, in theory, run complex simulations with many variables. For the field of cosmology, this could lend itself to applications in modeling the early universe as a quantum system to better understand large scale properties of the universe today. Here we utilize the hybrid variational quantum eigensolver (VQE) algorithm applied to an anharmonic oscillator system using QISKit to examine it's effectiveness for these cosmological questions. We then analyze a 1+1 dimensional ring of scalar bosons acting on a lattice as a naive model of the early universe. We chose to focus on rings of 3 and 5 massive scalars in 1+1 dimensions for our study to test the effectiveness of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron Beam Collimation for the Next Generation Light Source

The Next Generation Light Source will deliver high (MHz) repetition rate electron beams to an array of free electron lasers. Because of the significant average current in such a facility, effective beam collimation is extremely important to minimize radiation damage to undulators, prevent quenches of superconducting cavities, limit dose rates outside of the accelerator tunnel and prevent equipment damage. This paper describes the early conceptual design of a collimation system, as well as initial results of simulations to test its effectiveness.

43 PARTICLE ACCELERATORS↗

Self-reported sunscreen use and urinary benzophenone-3 concentrations in the United States: NHANES 2003–2006 and 2009–2012

Background: Sunscreens protect against skin cancer and other harmful effects of solar ultraviolet radiation (UVR). Epidemiologic and public health surveys often rely on self-reported sunscreen use to estimate sun exposure and avoidance, but questions remain about the validity of self-reports. Benzophenone-3 (BP-3), a common sunscreen ingredient, can be detected in the urine. Prior studies suggest that BP-3 concentrations increase after application of sunscreen. Objectives: The goal of this study was to assess the validity of self-reported frequency of sunscreen use in relation to urinary BP-3 concentrations in a representative sample of the general US population, including in sub-groups defined by age, sex and race/ethnicity. Methods: To assess the relationship between categorical self-reported sunscreen use and creatinine-corrected urinary BP-3 concentrations, we conducted a linear regression adjusted for age, sex, race/ethnicity, six-month time period, body mass index, education, and sun avoidance behaviors. We tested for effect modification by age, sex, ethnicity and time period of measurement using multiplicative interaction terms and a F test. Results: BP-3 was positively associated with self-reported frequency of sunscreen use across all ages, sexes, race/ethnicities, and time periods. Crude and multivariate adjusted models were all statistically significant. R-square was relatively low for all models, ranging from 0.15 to 0.43. Conclusions: Urinary BP-3 is positively associated with self-reported frequency of sunscreen use in the general US population, even in groups with overall low sunscreen use. These results suggest that self-report is a valid, although weak, way of assessing relative frequencies of sunscreen usage in a population-based study. - Highlights: • Urinary benzophenone-3 (BP-3) is a metabolite of a common sunscreen ingredient. • We modeled urinary BP-3 against self-reported sunscreen usage. • We observed a positive association between sunscreen use and urinary BP-3. • R{sup 2} was low, suggesting self-report is a valid but weak way to assess sunscreen use.

54 ENVIRONMENTAL SCIENCES↗