Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Novel, dually radiolabeled peptides for simultaneous monitoring of enzymatic activity and protein targets

This application investigated a novel imaging approach to develop methods to incorporate multiple radionuclides into a single peptide at chemoselective sites for simultaneous monitoring of cell-bound protein targets as well as specific enzymatic activity, both of which are associated with enhanced tumor growth and metastasis. This imaging construct was synthesized in such a manner so that the PET radionuclide will remain associated with the tumor cells and the SPECT radionuclide was cleaved from the imaging agent. Measurement of the PET agent only will yield information about the tumor marker density while measurement of the amount of co-localization and mismatch of the two radionuclides will yield information about the enzymatic activity. This coincident measuring technique using both PET and SPECT agents allows us to draw correlations involving the interactions of enzymes (cathepsin, serine-protease urokinase (uPA) and matrix metalloproteases) and other cellular proteins which play a role in cancer growth and metastasis. This technique will allow for studies in xenograft or genetic models of cancer in the same animal at the same time, thus eliminating problems that may occur when trying to invoke comparisons across animals or timepoints. By using radionuclide imaging as opposed to other imaging modalities, this technique has the potential to be translatable and can exploit the high specific activity probes which can be generated with radiotracers. The proof of principle test of this system investigated simultaneous monitoring of matrix metalloprotease (MMP) activity in the extracellular matrix (ECM) as well as density of integrins on the cell surface, both of which can serve as tumor markers. The outcomes/deliverables of this project were as follows: 1. Peptides were synthesized dually labeled at chemospecific sites with PET and SPECT agents. 2. Stability (intrinsic and to radiolysis) and specific activity of these labeled compounds were determined. 3. The feasibility of using these agents for simultaneous monitoring of MMP-2 enzymatic activity and $\alpha v \beta 3$ integrin density was demonstrated in several in vitro assays Radiotracers can be detected at concentrations up to 1000 fold lower than those labeled with non-radioactive markers (e.g. MRI contrast agents), thus using this technique has the advantage of very high sensitivity to measure these processes in vivo. Hence, the development of an efficient approach to the dual labeling of these molecular probes is embodied within this project, with the end result yielding a molecular imaging probe with the highest specific activity possible. An advantage to this dual labeling approach is the ability to measure two different biochemical processes at the same time, a benefit which is not possible in scans involving protocols utilizing two different radiolabeled agents injected sequentially. Another advantage to this technique is the ability to measure enzymatic activity in the form of substrate cleavage. This can only be achieved with a dually labeled compound as has been demonstrated in the case of FRET1. To our knowledge this is the first instance of a measurement of enzymatic substrate cleavage by a dually labeled PET/SPECT radionuclide imaging agent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of atomic substitution on core-hole relaxation dynamics: A study of Br 2 and IBr

Understanding inner-shell decay processes in heavy-element molecules is essential for unraveling x-ray-induced photodynamics and advancing molecular imaging techniques. Here, in this study, we investigate the influence of atomic substitution on core-hole relaxation dynamics and molecular fragmentation in Br 2 and IBr, initiated by x-ray ionization absorption at the Br K-edge. Using a combination of x-ray/ion coincidence measurements and Monte Carlo/molecular dynamics simulations, we track the charge distribution and the kinetic energy release (KER) of fragment ions with a total charge from 2+ to 8+. For both molecules, the simulated KER values show good agreement with experiment across different fragmentation channels. Our comparison reveals that substituting Br with the heavier I atom in IBr has a minimal impact on the inner-shell electronic decay process but significantly influences nuclear motion, leading to slower dissociation and thus a KER close to the Coulomb limit—an effect attributed to the atomic mass. These findings highlight the interplay between electronic and nuclear effects in molecular fragmentation, particularly in heavy-element species, and provide new insights into medical therapies, structural biology, and astrophysics.

Bhat, Nivedita [Argonne National Laboratory (ANL),↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Field–Driven Melting of a Molecular Solid at the Atomic Scale

Solid–liquid phase transitions are basic physical processes, but atomically resolved microscopy has yet to capture their full dynamics. A new technique is developed for controlling the melting and freezing of self–assembled molecular structures on a graphene field–effect transistor (FET) that allows phase–transition behavior to be imaged using atomically resolved scanning tunneling microscopy. This is achieved by applying electric fields to 2,3,5,6–tetrafluoro–7,7,8,8–tetracyanoquinodimethane–decorated FETs to induce reversible transitions between molecular solid and liquid phases at the FET surface. Nonequilibrium melting dynamics are visualized by rapidly heating the graphene substrate with an electrical current and imaging the resulting evolution toward new 2D equilibrium states. An analytical model is developed that explains observed mixed–state phases based on spectroscopic measurement of solid and liquid molecular energy levels. The observed nonequilibrium melting dynamics are consistent with Monte Carlo simulations.

36 MATERIALS SCIENCE↗

Implementation of Remote 3-Dimensional Image Guided Radiation Therapy Quality Assurance for Radiation Therapy Oncology Group Clinical Trials

Purpose: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. Methods and Materials: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. Results: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. Conclusion: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutrino event selection in the MicroBooNE liquid argon time projection chamber using Wire-Cell 3D imaging, clustering, and charge-light matching

An accurate and efficient event reconstruction is required to realize the full scientific capability of liquid argon time projection chambers (LArTPCs). The current and future neutrino experiments that rely on massive LArTPCs create a need for new ideas and reconstruction approaches. Wire-Cell, proposed in recent years, is a novel tomographic event reconstruction method for LArTPCs. The Wire-Cell 3D imaging approach capitalizes on charge, sparsity, time, and geometry information to reconstruct a topology-agnostic 3D image of the ionization electrons prior to pattern recognition. A second novel method, the many-to-many charge-light matching, then pairs the TPC charge activity to the detected scintillation light signal, thus enabling a powerful rejection of cosmic-ray muons in the MicroBooNE detector. A robust processing of the scintillation light signal and an appropriate clustering of the reconstructed 3D image are fundamental to this technique. In this paper, we describe the principles and algorithms of these techniques and their successful application in the MicroBooNE experiment. A quantitative evaluation of the performance of these techniques is presented. Using these techniques, a 95% efficient pre-selection of neutrino charged-current events is achieved with a 30-fold reduction of non-beam-coincident cosmic-ray muons, and about 80% of the selected neutrino charged-current events are reconstructed with at least 70% completeness and 80% purity.

3D imaging↗

Hydraulic fracture mapping using wavelet-based fusion of wave transmission and emission measurements

Fracture characterization is essential to hydrocarbon and geothermal exploration and production as well as carbon geo-sequestration. Active and passive measurements have been extensively applied to map fractures across various scales. Active and passive methods have inherent advantages and limitations that complement each other. Here, in this study, to improve the mapping of embedded fractures and the surrounding geomechanically altered regions, we integrate active shear-wave transmission measurement with passive acoustic-emission measurement collected during a lab-scale hydraulic-fracturing experiment. The proposed data fusion leverages the advantages of the two modalities of measurements, while minimizing their individual limitations. Polarized shear-wave transmission (active) measurement was collected before and after the hydraulic fracturing, and the acoustic emission (passive) measurement was collected during hydraulic fracturing. Two sets of two-dimensional maps of fracture and fracture-induced damage in axial, median and frontal planes were obtained by separately processing active and passive measurements. These 2D maps are then fed to wavelet-based image fusion technique to integrate the two sources of information for the reliable mapping/imaging of the embedded fractures and the surrounding geomechanically altered regions.

58 GEOSCIENCES↗

Three-dimensional imaging of dislocation dynamics during the hydriding phase transformation

Crystallographic imperfections can significantly alter material properties and responses to external stimuli, including solute induced phase transformations and crystal growth and dissolution . Despite recent progress in imaging defects using both electron and x-ray techniques, in situ three-dimensional imaging studies of defect dynamics, necessary to understand and engineer nanoscale processes, remains challenging. Here, we report in situ three-dimensional imaging of defect dynamics during the hydriding phase transformation of individual palladium nanocrystals by Bragg Coherent Diffractive Imaging (BCDI) . During constant pressure experiments, we observed that the phase transformation begins after the nucleation of dislocations in large (300 nm) particles. The 3D dislocation network shows that dislocations are close to the phase boundary. The 3D phase morphology resolved by BCDI suggests that the hydrogen-rich phase is more similar to a spherical cap on the hydrogen-poor phase than the core-shell model commonly assumed. We substantiate this conclusion using 3D phase field modeling and demonstrate how phase morphology affects the critical size for dislocation nucleation. We determine the size dependence of the transformation pressure for large (150-300 nm) palladium nanocrystals using variable pressure experiments. Our results reveal a pathway for solute induced structural phase transformations in nanocrystals and demonstrate BCDI as a novel method for understanding dislocation dynamics in phase transforming systems at the nanoscale.

36 MATERIALS SCIENCE↗

Model based atomic resolution tomography

Electron tomography is a valuable three-dimensional characterization method, but the technique has so far been limited to a nanometer scale resolution, and therefore complementary two-dimensional structural analysis is generally performed using other techniques. In this paper, computer simulations of the latest transmission electron microscope technologies are performed on a CeO{sub 2} supercell to investigate the extension of electron tomography to the atomic scale resolution, from a tilt series of high resolution electron microscopy (HREM) images. We showed that high-voltage and aberration-corrected microscopes were both capable of retrieving adjacent oxygen and Ce atoms for a thickness up to 2.5 nm. In the case where only a few tilt angle projections are in zone-axis orientations, we introduced a hybrid tomography method, whereby a lattice-resolved tomogram obtained from a few zone-axis projections is combined with the external shape reconstruction of the crystal from binary projections. Finally, we discussed some experimental challenges related to the proposed HREM tomography technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Galaxy blending effects in deep imaging cosmic shear probes of cosmology

ABSTRACT Upcoming deep imaging surveys such as the Vera C. Rubin Observatory Legacy Survey of Space and Time will be confronted with challenges that come with increased depth. One of the leading systematic errors in deep surveys is the blending of objects due to higher surface density in the more crowded images; a considerable fraction of the galaxies which we hope to use for cosmology analyses will overlap each other on the observed sky. In order to investigate these challenges, we emulate blending in a mock catalogue consisting of galaxies at a depth equivalent to 1.3 yr of the full 10-yr Rubin Observatory that includes effects due to weak lensing, ground-based seeing, and the uncertainties due to extraction of catalogues from imaging data. The emulated catalogue indicates that approximately 12 per cent of the observed galaxies are ‘unrecognized’ blends that contain two or more objects but are detected as one. Using the positions and shears of half a billion distant galaxies, we compute shear–shear correlation functions after selecting tomographic samples in terms of both spectroscopic and photometric redshift bins. We examine the sensitivity of the cosmological parameter estimation to unrecognized blending employing both jackknife and analytical Gaussian covariance estimators. An ∼0.025 decrease in the derived structure growth parameter S8 = σ8(Ωm/0.3)0.5 is seen due to unrecognized blending in both tomographies with a slight additional bias for the photo-z-based tomography. This bias is greater than the 2σ statistical error in measuring S8.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP4-13: PET Image Noise Variability and Its Consequences for Quantifying Tumor Hypoxia

Purpose: The values in a PET image which represent activity concentrations of a radioactive tracer are influenced by a large number of parameters including patient conditions as well as image acquisition and reconstruction. This work investigates noise characteristics in PET images for various image acquisition and image reconstruction parameters. Methods: Different phantoms with homogeneous activity distributions were scanned using several acquisition parameters and reconstructed with numerous sets of reconstruction parameters. Images from six PET scanners from different vendors were analyzed and compared with respect to quantitative noise characteristics. Local noise metrics, which give rise to a threshold value defining the metric of hypoxic fraction, as well as global noise measures in terms of noise power spectra (NPS) were computed. In addition to variability due to different reconstruction parameters, spatial variability of activity distribution and its noise metrics were investigated. Patient data from clinical trials were mapped onto phantom scans to explore the impact of the scanner’s intrinsic noise variability on quantitative clinical analysis. Results: Local noise metrics showed substantial variability up to an order of magnitude for different reconstruction parameters. Investigations of corresponding NPS revealed reconstruction dependent structural noise characteristics. For the acquisition parameters, noise metrics were guided by Poisson statistics. Large spatial non-uniformity of the noise was observed in both axial and radial direction of a PET image. In addition, activity concentrations in PET images of homogeneous phantom scans showed intriguing spatial fluctuations for most scanners. The clinical metric of the hypoxic fraction was shown to be considerably influenced by the PET scanner’s spatial noise characteristics. Conclusion: We showed that a hypoxic fraction metric based on noise characteristics requires careful consideration of the various dependencies in order to justify its quantitative validity. This work may result in recommendations for harmonizing QA of PET imaging for multi-institutional clinical trials.

60 APPLIED LIFE SCIENCES↗

Radar clutter suppression

I have been working on something called clutter, which is an amount of “noise” caused by the surrounding environment in a radar system photo or image. The radar system is called “synthetic aperture radar” or SAR. Our group is trying to clarify the photo and hence data of an SAR image by removing clutter (and noise) from the photograph. This is done by utilizing advanced signal processing techniques and the MATLAB programming language on our computer.

Evans, Bradley [External Affiliation]↗

Real World Use Case Evaluation of Radar Retro-reflectors for Autonomous Vehicle Lane Detection Applications

Lane detection plays a critical role in autonomous vehicles for safe and reliable navigation. Lane detection is traditionally accomplished using a camera sensor and computer vision processing. The downside of this traditional technique is that it can be computationally intensive when high quality images at a fast frame rate are used and has reliability issues from occlusion such as, glare, shadows, active road construction, and more. This study addresses these issues by exploring alternative methods for lane detection in specific scenarios caused from road construction-induced lane shift and sun glare. Specifically, a U-Net, a convolutional network used for image segmentation, camera-based lane detection method is compared with a radar-based approach using a new type of sensor previously unused in the autonomous vehicle space: radar retro-reflectors. This evaluation is performed using ground truth data, obtained by measuring the lane positions and transforming them into pixel coordinates. The performance of each method is assessed using the statistical R2 score, indicating the correlation between the detected lane lines and the ground truth. The results show that the U-Net camera-based method exhibits limitations in accurately detecting and aligning the lane lines, particularly in challenging scenarios. However, the radar-based lane detection method demonstrates a strong correlation with the ground truth which implies that the use of this sensor may improve current reliability issues from conventional camera lane detection approach. Furthermore, the study highlights the limitations of the U-Net model for camera lane detection, especially in scenarios with sun glare. This study shows that infrastructure-based radar retro-reflectors can improve autonomous vehicle lane detection reliability. The integration of different sensor modalities and the development of advanced computer vision algorithms are crucial for improving the accuracy, reliability, and energy efficiency of lane detection systems. Addressing these challenges contributes to the advancement of autonomous vehicles and the realization of safer and more efficient transportation systems.

Brown, Nicolas E.↗

Deciphering the Cathode-Electrolyte Interfacial Chemistry in Sodium Layered Cathode Materials

The ever–increasing demand for stationary energy storage has driven the prosperous investigation of low–cost sodium ion batteries. The inferior long–term cycling stability of cathode materials is a significant roadblock toward the wide commercialization of sodium ion batteries. This study enlightens a path toward empowering stable sodium ion batteries through incisive diagnostics of the multiscale surface chemical processes in layered oxide materials (e.g., O3–NaNi 1/3 Fe 1/3 Mn 1/3 O 2 ). The major challenges are unraveled in a promising sodium layered cathode material using a range of complementary advanced spectroscopic and imaging diagnostic techniques. It is discovered that the cathode–electrolyte interfacial reaction triggers transition metal reduction, heterogeneous surface reconstruction, metal dissolution, and formation of intragranular nanocracks. These surface chemistry driven processes are partly responsible for significant performance decay. This diagnostic study also rationalizes the elemental substitution and surface passivation methods that are widely applied in the field. The prepassivated and Ti–substituted cathode materials allow for significantly improved cycling stability by inhibiting the metal dissolution. Furthermore, incisively diagnosing the interfacial chemistry not only creates scientific insights into understanding sodium cathode chemistry, but also represents an advance toward establishing universal interfacial design principles for all alkali metal ion cathode materials.

25 ENERGY STORAGE↗

Defect Detection of Industrial Radiography Images of Ammonia Pipes by a Sparse Coding Model

Pipeline transportation systems for liquid anhydrous ammonia require periodic inspections for pipe defects. Defects such as crack-like flaws, including those due to stress corrosion and fatigue crack growth and fatigue of welded joints, can be tested by in situ radiography testing (RT). It is required that the detection technique should reveal the defect region without any significant distortion. Imaging noise such as that due to radiation scattering reduces contrast over the whole or part of the image, causing a reduction in image quality. Various image processing methods can be utilized to improve the outcome of RT of pipes. The sparse coding model is a powerful contrast improvement algorithm, but it tends to eliminate imaging details, passing them off as noise. We present a novel implementation of the sparse coding model based on a probabilistic interpretation to improve defect detection in ammonia pipelines radiography images. The performance of this procedure was evaluated in radiographic images of defect and corrosion regions for different pipe types. For ammonia pipes, the technique was found to offer a significant improvement in defect detection while preserving imaging details.

42 ENGINEERING↗

TU-AB-BRB-02: Stochastic Programming Methods for Handling Uncertainty and Motion in IMRT Planning

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

X-ray phase-contrast imaging with an Inverse Compton Scattering source

Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.

07 ISOTOPE AND RADIATION SOURCES↗