Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “targeted”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Characterization of high-current electron beam interaction with metal targets

The process of electron beam interaction with metal targets was characterized using electrical and optical diagnostics. Electron beams with current density of 5-10 A/cm{sup 2}, electron energy up to 120 keV, pulse duration up to 200 {mu}s, and cross-sectional area of 8-30 cm{sup 2} at the target surface were generated by GESA I and GESA II facilities. Streak imaging of the target surface specular reflectivity was used to determine the onset of melting and re-solidification of the target surface. Using time- and space-resolved schlieren imaging, the evolution of surface irregularities was studied. Experimental and numerical investigations of the neutral flow evaporated from the target surface showed a neutral density of {approx}10{sup 19} cm{sup -3} in the vicinity of the target and neutral velocities up to 2 x 10{sup 5} cm/s. Framing and streak images of visible light emission were used to study the temporal evolution of the target surface plasma and vapors. Time- and space-resolved spectroscopy was applied to determine the surface plasma density and temperature, which were found to be {approx}10{sup 14} cm{sup -3} and {<=}1 eV, respectively. Because of this small plasma density, electric fields in the plasma sheath are not sufficient to cause electrohydrodynamic instability of the liquid target surface. However, hydrodynamic instabilities due to the intense neutral flow observed in experimental and numerical studies are likely to be responsible for the growth of wavelike irregularities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cluster perturbation theory. II. Excitation energies for a coupled cluster target state

In cluster perturbation (CP) theory, we consider a target excitation space relative to a Hartree-Fock state and partition the target excitation space into a parent excitation space and an auxiliary excitation space. The zeroth-order state is in CP theory a coupled cluster (CC) state in the parent excitation space, and the target state is a CC state in the target excitation space. In this paper, we derive CP series for excitation energies in orders of the CC parent-state similarity-transformed fluctuation potential where the zeroth-order term in the series is an excitation energy for the CC parent state response eigenvalue equation and where the series formally converge to an excitation energy for the CC target state response eigenvalue equation. We give explicit expressions for the lowest-order excitation energy corrections. We also report calculations for CP excitation energy series for various parent and target excitation spaces and examine how well the lower-order corrections can reproduce the total excitation energies. Considering the fast local convergence we have observed for the CP excitation energy series, it becomes computationally attractive to use low-order corrections in CP series to obtain excitation energies of CC target state quality. For the CPS(D-n) series, the first-order correction vanishes, the second-order correction becomes the CIS(D) model, and for the CPS(D-3) model, our calculations suggest that excitation energies of CCSD quality are obtained. The numerical results also suggest that a similar behavior can be seen for the low-order excitation energy corrections for CP series where the parent state contains more than a singles excitation space, e.g., for the CPSD(T) model. Finally, we therefore expect the low-order excitation energy corrections in CP series soon to become state-of-the-art models for determining excitation energies of CC target state quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic targets with graphene backing

Many of the isotopes cannot be made as free-standing targets and require thin film backing. Low-Z backing materials, such as amorphous carbon and thin polymer films are materials of choice for some experiments. However, the limitations of these backing materials are poor thermal and mechanical stability. All-carbon graphene films would be an excellent choice as a backing material due to their high thermal conductivity, high temperature tolerance (3550ºC melting point), low outgassing, mechanical integrity, and ease of handling. We fabricated a variety of targets using graphene material as a backing or a host matrix. Using PVD sputtering deposition of boron-11 carbide, we fabricated 11 B target with a 0.5 mg/cm 2 on graphene film. The 11 B isotope is of interest due to aneutronic proton–boron fusion reaction 1 p + 11 B → 3 4 He + 8.7 MeV suitable for clean energy production1. We also prepared a neutron rich natCr target on graphene backing by electroplating Cr in an aqueous chromium (III) oxide bath. The chromium target can be used for production of positron emitting Mn radioisotope2 in the reaction 52 Cr (p,n) 52 Mn. One of the unique advantages of the graphene film fabrication process is the capability to embed target materials, including refractory metals, in the nanoparticle form into a host graphene matrix during target preparation. Finally, we fabricated nat Ir, nat Re, nat WO3, and nat HfO 2 nanoparticle-loaded graphene targets that can be used in nuclear physics research.

36 MATERIALS SCIENCE↗

Plasma expansion and relativistic filamentation in intense laser-irradiated cone targets

We report that compound parabolic concentrator (CPC) cone targets have been shown to produce increased MeV photons on the NIF-ARC by 10× over flat targets. Multiple x-ray frames can potentially be generated by firing the NIF-ARC's beamlets into distinct cone targets at few nanosecond relative delays. This requires that the cone targets with delayed beams are not degraded by their proximity to previous targets. One concern is that the spatial wings of a beam fired into one target can fall on neighboring targets, producing a preformed plasma that may interfere with laser light reaching the tip of the cone. In this work, 3D hydra simulations of realistic targets and beam parameters show that hundreds of micrometer scale length preplasmas are produced in cones within 1 mm of the laser spot. 2D particle-in-cell simulations of the intense main pulse in this preplasma indicate a density threshold for the onset of relativistic filamentation in our conditions. Applying our modeling approach to a NIF-ARC shot with an intentional 15 J prepulse yields good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Targeted polyelectrolyte complex micelles treat vascular complications in vivo

Vascular disease is a leading cause of morbidity and mortality in the United States and globally. Pathological vascular remodeling, such as atherosclerosis and stenosis, largely develop at arterial sites of curvature, branching, and bifurcation, where disturbed blood flow activates vascular endothelium. Current pharmacological treatments of vascular complications principally target systemic risk factors. Improvements are needed. We previously devised a targeted polyelectrolyte complex micelle to deliver therapeutic nucleotides to inflamed endothelium in vitro by displaying the peptide VHPKQHR targeting vascular cell adhesion molecule 1 (VCAM-1) on the periphery of the micelle. This paper explores whether this targeted nanomedicine strategy effectively treats vascular complications in vivo. Disturbed flow-induced microRNA-92a (miR-92a) has been linked to endothelial dysfunction. We have engineered a transgenic line (miR-92a EC-TG /Apoe –/– ) establishing that selective miR-92a overexpression in adult vascular endothelium causally promotes atherosclerosis in Apoe –/– mice. We tested the therapeutic effectiveness of the VCAM-1–targeting polyelectrolyte complex micelles to deliver miR-92a inhibitors and treat pathological vascular remodeling in vivo. VCAM-1–targeting micelles preferentially delivered miRNA inhibitors to inflamed endothelial cells in vitro and in vivo. The therapeutic effectiveness of anti–miR-92a therapy in treating atherosclerosis and stenosis in Apoe –/– mice is markedly enhanced by the VCAM-1–targeting polyelectrolyte complex micelles. These results demonstrate a proof of concept to devise polyelectrolyte complex micelle-based targeted nanomedicine approaches treating vascular complications in vivo.

60 APPLIED LIFE SCIENCES↗

Results of Ion Cyclotron Heating Experiments on Proto-MPEX Utilizing a Movable Stainless Steel Target

Ion cyclotron heating (ICH) at a frequency in the 6- to 9-MHz range with electron heating in the 28- to 105-GHz range will be used in the Material Plasma Exposure eXperiment (MPEX) to greatly increase the energy of the plasma stream produced by the helicon plasma source. ICH was chosen over substrate biasing to produce energetic ions because it can more accurately reproduce plasma-material interactions in a fusion device. For instance, when the target is tilted with respect to the background magnetic field during ICH, a magnetic presheath is created so that redeposition phenomena as in a tokamak divertor can be better approximated. ICH experiments were conducted on the Proto-MPEX device, which was developed to provide a physics basis upon which MPEX is designed. In this paper we describe some of these experiments in which the previous fixed graphite target was replaced by a movable stainless steel target. With the new target, the strong, monotonic decrease in ion temperature observed previously as a function of axial distance between the ion cyclotron resonance region and the target was not observed. Instead, only a small drop was seen within ~1 cm of the target. The ion temperatures were determined spectroscopically, utilizing Doppler broadening measurements of an Ar II line, in a plasma that is 90% deuterium and 10% argon. Measurements were obtained using optical fibers at a fixed location, with the target moving perpendicularly relative to the viewing chords. Comparisons with previous results will be discussed, including observed plasma parameters Ti, Te, and ne, and heat flux at the target.

Goulding, Richard↗

Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility

Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE SDSS-III BARYON OSCILLATION SPECTROSCOPIC SURVEY: QUASAR TARGET SELECTION FOR DATA RELEASE NINE

The SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS), a five-year spectroscopic survey of 10,000 deg{sup 2}, achieved first light in late 2009. One of the key goals of BOSS is to measure the signature of baryon acoustic oscillations (BAOs) in the distribution of Ly{alpha} absorption from the spectra of a sample of {approx}150,000 z > 2.2 quasars. Along with measuring the angular diameter distance at z Almost-Equal-To 2.5, BOSS will provide the first direct measurement of the expansion rate of the universe at z > 2. One of the biggest challenges in achieving this goal is an efficient target selection algorithm for quasars in the redshift range 2.2 < z < 3.5, where their colors tend to overlap those of the far more numerous stars. During the first year of the BOSS survey, quasar target selection (QTS) methods were developed and tested to meet the requirement of delivering at least 15 quasars deg{sup -2} in this redshift range, with a goal of 20 out of 40 targets deg{sup -2} allocated to the quasar survey. To achieve these surface densities, the magnitude limit of the quasar targets was set at g {<=} 22.0 or r {<=} 21.85. While detection of the BAO signature in the distribution of Ly{alpha} absorption in quasar spectra does not require a uniform target selection algorithm, many other astrophysical studies do. We have therefore defined a uniformly selected subsample of 20 targets deg{sup -2}, for which the selection efficiency is just over 50% ({approx}10 z > 2.20 quasars deg{sup -2}). This 'CORE' subsample will be fixed for Years Two through Five of the survey. For the remaining 20 targets deg{sup -2}, we will continue to develop improved selection techniques, including the use of additional data sets beyond the Sloan Digital Sky Survey (SDSS) imaging data. In this paper, we describe the evolution and implementation of the BOSS QTS algorithms during the first two years of BOSS operations (through 2011 July), in support of the science investigations based on these data, and we analyze the spectra obtained during the first year. During this year, 11,263 new z > 2.20 quasars were spectroscopically confirmed by BOSS, roughly double the number of previously known quasars with z > 2.20. Our current algorithms select an average of 15 z > 2.20 quasars deg{sup -2} from 40 targets deg{sup -2} using single-epoch SDSS imaging. Multi-epoch optical data and data at other wavelengths can further improve the efficiency and completeness of BOSS QTS.

79 ASTRONOMY AND ASTROPHYSICS↗

Extracorporeal adsorption therapy: A Method to improve targeted radiation delivered by radiometal-labeled monoclonal antibodies.

Many investigators have demonstrated the ability to treat hematologic malignancies with radiolabeled monoclonal antibodies targeting hematopoietic antigens such as anti-CD20 and anti-CD45. [1-5] Although the remission rates achieved with radioimmunotherapy (RIT) are relatively high, many patients subsequently relapse presumably due to suboptimal delivery of enough radiation to eradicate the malignancy. The dose-response of leukemia and lymphoma to radiation has been proven. Substantial amounts of radiation can be delivered by RIT if followed by hematopoietic cell transplantation to rescue the bone marrow from myeloablation.[ref] However, the maximum dose of RIT that can be used is still limited by toxicity to normal tissues affected by nonspecific delivery of radiation. Efforts to improve RIT focus on improving the therapeutic ratios of radiation in target versus non-target tissues by removing the fraction of radioisotope that fails to bind to target tissues and circulates freely in the bloodstream perfusing non-target tissues. Our group and others have explored several alternatives for removal of unbound circulating antibody. [refs] One such method, extracorporeal adsorption therapy (ECAT) consists of removing unbound antibody by a method similar to plasmapheresis after critical circulation time and distribution of antibody into target tissues have been achieved. Preclinical studies of ECAT in murine xenograft models demonstrated significant improvement in therapeutic ratios of radioactivity. Chen and colleagues demonstrated that a 2-hour ECAT procedure could remove 40 to 70% of the radioactivity from liver, lung and spleen. [ref] Although isotope concentration in the tumor was initially unaffected, a 50% decrease was noted approximately 36 hours after the procedure. This approach was also evaluated in a limited phase I pilot study of patients with refractory B-cell lymphoma. [ref] After radiographic confirmation of tumor localization of a test dose of anti-CD20 antibody labeled with indium-111 (111In), seven patients received RIT with anti-CD20 antibody labeled with indium-111 for biokinetics and dosimetry, and therapeutic doses of antibody labeled with yttrium-90 (90Y). Performing the ECAT procedure at a rate that such that one blood volume per hour were circulated for 3 hours, resulted in mean radioactivity depletion of 96% in whole blood, 49% in whole body 49%, 62% in the lungs and 40% in liver and kidneys. There was no sufficient data to determine whether there was an improvement in the relative delivery of radiation to the tumor compared to normal organs by performing ECAT, but pharmacokinetic modeling studies suggested a potential therapeutic advantage using this approach. [refs] To evaluate the potential therapeutic advantages of ECAT, we performed biodistribution studies in nonhuman primates comparing the therapeutic ratios of radiation delivered using this approach to those delivered by conventional RIT alone. In addition, we evaluated lutetium-177 (177Lu) as an alternative isotope to optimize the delivery of RIT by improving the therapeutic index (target to non-target ratio)

60 APPLIED LIFE SCIENCES↗

Transparent conducting impurity-doped ZnO thin films prepared using oxide targets sintered by millimeter-wave heating

The preparation of transparent conducting impurity-doped ZnO thin films by both pulsed laser deposition (PLD) and magnetron sputtering deposition (MSD) using impurity-doped ZnO targets sintered with a newly developed energy saving millimeter-wave (28 GHz) heating technique is described. Al-doped ZnO (AZO) and V-co-doped AZO (AZO:V) targets were prepared by sintering with various impurity contents for 30 min at a temperature of approximately 1250 degree sign C in an air or Ar gas atmosphere using the millimeter-wave heating technique. The resulting resistivity and its thickness dependence obtainable in thin films prepared by PLD using millimeter-wave-sintered AZO targets were comparable to those obtained in thin films prepared by PLD using conventional furnace-sintered AZO targets; a low resistivity on the order of 3x10{sup -4} {Omega} cm was obtained in AZO thin films prepared with an Al content [Al/(Al+Zn) atomic ratio] of 3.2 at. % and a thickness of 100 nm. In addition, the resulting resistivity and its spatial distribution on the substrate surface obtainable in thin films prepared by rf-MSD using a millimeter-wave-sintered AZO target were almost the same as those obtained in thin films prepared by rf-MSD using a conventional powder AZO target. Thin films prepared by PLD using millimeter-wave-sintered AZO:V targets exhibited an improved resistivity stability in a high humidity environment. Thin films deposited with a thickness of approximately 100 nm using an AZO:V target codoped with an Al content of 4 at. % and a V content [V/(V+Zn) atomic ratio] of 0.2 at. % were sufficiently stable when long-term tested in air at 90% relative humidity and 60 degree sign C.

36 MATERIALS SCIENCE↗

Potential underestimation of the internal target volume (ITV) from free-breathing CBCT

Purpose: Localization prior to delivery of SBRT to free-breathing patients is performed by aligning the planning internal target volume (ITV) from 4DCT with an on-board free-breathing cone-beam CT (FB-CBCT) image. The FB-CBCT image is assumed to also generate an ITV that captures the full range of motion, due to the acquisition spanning multiple respiratory cycles. However, the ITV could potentially be underestimated when the ratio of time spent in inspiration versus time spent in expiration (I/E ratio) deviates from unity. Therefore, the aim of this study was to investigate the effect of variable I/E ratios on the FB ITV generated from a FB-CBCT scan. Methods: This study employed both phantom and patient imaging data. For the phantom study, five periodic respiratory cycles were simulated with different I/E ratios. Six patient respiratory cycles with variable I/E ratios were also selected. All profiles were then programmed into a motion phantom for imaging and modified to exhibit three peak-to-peak motion amplitudes (0.5, 1.0, and 2.0 cm). Each profile was imaged using two spherical targets with 1.0 and 3.0 cm diameters. 2D projections were acquired with full gantry rotation of a kiloVoltage (kV) imager mounted onto the gantry of a modern linear accelerator. CBCT images were reconstructed from 2D projections using a standard filtered back-projection reconstruction algorithm. Quantitative analyses for the phantom study included computing the change in contrast along the direction of target motion as well as determining the area (which is proportional to the target volume) inside of the contour extracted using a Canny edge detector. For the patient study, projection data that were previously acquired under an investigational 4D CBCT slow-gantry imaging protocol were used to generate both FB-CBCT and 4D CBCT images. Volumes were then manually contoured from both datasets (using the same window and level) for quantitative comparison. Results: The phantom study indicated a reduction in contrast at the inferior edge of the ITV (corresponding to inspiration) as the ratio decreased, for both simulated and patient respiratory cycles. For the simulated phantom respiratory cycles, the contrast reduction of the smallest I/E ratio was 27.6% for the largest target with the smallest amplitude and 89.7% for the smallest target with the largest amplitude. For patient respiratory cycles, these numbers were 22.3% and 94.0%, respectively. The extracted area from inside of the target contours showed a decreasing trend as the I/E ratio decreased. In the patient study, the FB-CBCT ITVs of both lung tumors studied were underestimated when compared with their corresponding 4D CBCT ITV. The underestimations found were 40.1% for the smaller tumor and 24.2% for the larger tumor. Conclusions: The ITV may be underestimated in a FB-CBCT image when a patient's respiratory pattern is characterized by a disparate length of time spent in inspiration versus expiration. Missing the full target motion information during on-board verification imaging may result in localization errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗

Interactions of relativistic heavy ions in thick heavy element targets and some unresolved problems

Interactions of relativistic heavy ions with total energies above 30 GeV in thick Cu and Pb targets (≥ 2 cm) have been studied with various techniques. Radiochemical irradiation experiments using thick Cu targets, both in a compact form or as diluted “2π-Cu targets” have been carried out with several relativistic heavy ions, such as 44 GeV {sup 12}C (JINR, Dubna, Russia) and 72 GeV {sup 40}Ar (LBL, Berkeley, USA). Neutron measuring experiments using thick targets irradiated with various relativistic heavy ions up to 44 GeV {sup 12}C have been performed at the JINR. In addition, the number of “black prongs” in nuclear interactions (due to protons with energies less than 30 MeV and emitted from the target-like interaction partner at rest) produced with 72 GeV {sup 22}Ne ions in nuclear emulsion plates has been measured in the first nuclear interaction of the primary {sup 22}Ne ion and in the following second nuclear interaction of the secondary heavy (Z > 1) ion. Some essential results have been obtained. (1) Spallation products produced by relativistic secondary fragments in interactions ([44 GeV {sup 12}C or 72 GeV {sup 40}Ar] + Cu) within thick copper yield fewer products close to the target and many more products far away from the target as compared to primary beam interactions. This applies also to secondary particles emitted into large angles (Θ > 10°). (2) The neutron production of 44 GeV {sup 12}C within thick Cu and Pb targets is beyond the estimated yield as based on experiments with 12 GeV {sup 12}C. These rather independent experimental results cannot be understood within well-accepted nuclear reaction models. They appear to present unresolved problems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetized Target Fusion Collaboration. Final report

Nuclear fusion has the potential to satisfy the prodigious power that the world will demand in the future, but it has yet to be harnessed as a practical energy source. The entry of fusion as a viable, competitive source of power has been stymied by the challenge of finding an economical way to provide for the confinement and heating of the plasma fuel. It is the contention here that a simpler path to fusion can be achieved by creating fusion conditions in a different regime at small scale (~ a few cm). One such program now under study, referred to as Magnetized Target Fusion (MTF), is directed at obtaining fusion in this high energy density regime by rapidly compressing a compact toroidal plasmoid commonly referred to as a Field Reversed Configuration (FRC). To make fusion practical at this smaller scale, an efficient method for compressing the FRC to fusion gain conditions is required. In one variant of MTF a conducting metal shell is imploded electrically. This radially compresses and heats the FRC plasmoid to fusion conditions. The closed magnetic field in the target plasmoid suppresses the thermal transport to the confining shell, thus lowering the imploding power needed to compress the target. The undertaking described in this report was to provide a suitable target FRC, as well as a simple and robust method for inserting and stopping the FRC within the imploding liner. The FRC must also survive during the time it takes for the metal liner to compress the FRC target. The initial work at the UW was focused on developing adequate preionization and flux trapping that were found to be essential in past experiments for obtaining the density, flux and most critically, FRC lifetime required for MTF. The timescale for testing and development of such a source can be rapidly accelerated by taking advantage of a new facility funded by the Department of Energy. At this facility, two inductive plasma accelerators (IPA) were constructed and tested. Recent experiments with these IPAs have demonstrated the ability to rapidly form, accelerate and merge two hypervelocity FRCs into a compression chamber. The resultant FRC that was formed was hot (T ion ~ 400 eV), stationary, and stable with a configuration lifetime several times that necessary for the MTF liner experiments. The accelerator length was less than 1 meter, and the time from the initiation of formation to the establishment of the final equilibrium was less than 10 microseconds. With some modification, each accelerator can be made capable of producing FRCs suitable for the production of the target plasma for the MTF liner experiment. Based on the initial FRC merging/compression results, the design and methodology for an experimental realization of the target plasma for the MTF liner experiment can now be defined. The construction and testing of the key components for the formation of the target plasma at the Air Force Research Laboratory (AFRL) will be performed on the IPA experiment, now at MSNW. A high density FRC plasmoid will be formed and accelerated out of each IPA into a merging/compression chamber similar to the imploding liner at AFRL. The properties of the resultant FRC plasma (size, temperature, density, flux, lifetime) will be obtained. The process will be optimized, and a final design for implementation at AFRL will be carried out. When implemented at AFRL it is anticipated that the colliding/merging FRCs will then be compressed by the liner. In this manner it is hoped that ultimately a plasma with ion temperatures reaching the 10 keV range and fusion gain near unity can be obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incorporating the Min-Max Mesh Optimization Method within the Target-Matrix Paradigm

The Target-Matrix Optimization Paradigm (TMOP) is a method for improving mesh quality via node movement. Through the use of appropriate pre-defined quality metrics and Target-matrices, TMOP provides the ability to define mesh quality in terms of element shape, volume, and edge orientation as a function of position within the mesh, thus facilitating high-level goals such as size-adapted meshing. The Paradigm is developed further in this paper by showing how it can be applied to the problem of improving the mesh in locations where the quality is the worst. Improving the worst quality portions of a mesh was investigated by Freitag, Amenta, and others, who showed that the problem can be formulated as a min-max optimization problem. The Target-paradigm is used to extend the previous work in two important respects. First, by using quality metrics from the Target-paradigm, quality can be user-specified via Target-matrices instead of the quality definition being hard-wired into the quality metric. Second, by making use of the sample point concept in TMOP, one can extend min-max mesh optimization to non-simplicial element types such as quadrilaterals. Numerical experiments were performed to illustrate these extensions and to investigate their utility. A non-gradient solver known as the amoeba was used to numerically compute the optimal solutions. This derivative-free method, in conjunction with the use of barrier metrics from TMOP, enables the solution of the min-max problem without the use of explicit constraints to guarantee that the optimal mesh is non-inverted. The experiments showed that the use of Target-metrics in min-max with triangle (or tetrahedral) element meshes is able to effectively improve the worst quality elements in terms of shape or in terms of size+shape. The experiments also showed that the mesh min-max extension to quadrilateral element meshes can lead to acceptable meshes using barrier metrics from the Target-paradigm, provided that inter-element mesh smoothness is not important. Poor behavior was observed when using non-barrier Target-metrics in min-max with quadrilateral element meshes. For both simplicial and quadrilateral meshes, the min-sum method can be competitive with min-max, however.

97 MATHEMATICS AND COMPUTING↗

Topics in LIFE Target Survival: 11-SI-004 Final Report

The LIFE target design incorporates many considerations to generate the desired fusion gain including the physics design, the cost of manufacturing of the target, the injectability of the target, the aerodynamic flight characteristics of the target, the ability to track and engage the target and to maintain the structural and thermal integrity of the target. This document describes the effort that was made in support of issues of survivability of the target during injection which included issues massmanufactural materials and processes which could be used in the target.

42 ENGINEERING↗

HARP targets pion production cross section and yield measurements. Implications for MiniBooNE neutrino flux

The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields, d 2 N π± (p; θ )=dpd Ω, on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum from 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target π + production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of v μ flux predictions for updated SW model is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗