Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Systematic Source Determination and X-Ray Radiography Detection of Nonuniformities on High-Density Carbon Ablators

Recent deuterium-tritium (D-T)–layered implosion experiments at the National Ignition Facility have achieved a burning plasma and >1-MJ neutron yield. A series of repeat experiments have shown that the degree of performance is very likely dependent on capsule quality, including the quantity of what are collectively termed “high- Z particles.” These particles are detected on a custom-built radiography system, known as the Sagometer, during the final target qualification process. The term particles is misleading, as the source of these nonuniformities in the capsule images is uncertain; the term detection will be used instead. An increased number of D-T targets have been rejected at the final stages of production due to Sagometer detections. Late detections are deleterious in terms of loss of production parts, effort, and overall operating efficiency. In response, we undertook an effort to determine the origin of these detections and to ultimately mitigate target losses caused by them. Through careful testing and analysis, we have determined neither insufficient production cleanliness nor hohlraum shedding is responsible for the detections on the capsule. Here, we determined that the detections are inherent to the capsule and have made efforts to use the Zeiss Xradia to identify them earlier in the production process. While testing revealed the Xradia is not currently sufficient for identifying such particles using radiography images, we continue to look to other forms of metrology to down select the capsules early in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of an H I-selected galaxy sample

We analyze the properties of a sample of galaxies identified in a 21cm, H I-line survey of selected areas in the Perseus-Pisces supercluster and its foreground void. Twelve fields were observed in the supercluster, five of them (target fields) centered on optically bright galaxies, and the other seven (blank fields) selected to contain no bright galaxies within 45 min. of their centers. We detected nine previously uncatalogued, gas-rich galaxies, six of them in the target fields. We also detected H I from seven previously catalogued galaxies in these fields. Observations in the void covered the same volume as the 12 supercluster fields at the same H I-mass sensitivity, but no objects were detected. Combining out H I data with optical broadband and H alpha imaging, we conclude that the properties of H I-selected galaxies do not differ substantially from those of late-type galaxies found in optical surveys. In particular, the galaxies in our sample do not appear to be unusually faint for their H I mass, or for their circular velocity. We find tentative evidence for a connection between optical surface brightness and degree of isolation, in the sense that low surface brightness galaxies tend to be more isolated. The previously catalogued, optically bright galaxies in our survey volume dominate the total H I mass density and cross section; the uncatalogued galaxies contribute only approximately 19 percent of the mass and approximately 12 percent of the cross section. Thus, existing estimates of the density and cross section of neutral hydrogen, most of which are based on optically selected galaxy samples, are probably accurate. Such estimates can be used to compare the nearby universe to the high-redshift universe probed by quasar absorption lines.

Szomoru, Arpad↗

X-Ray Absorbed, Broad-Lined, Red AGN and the Cosmic X-ray Background

This award represents the second phase of an X-ray study of QSOs that are heavily obscured in the optical/near-IR. An earlier survey revealed that these active galactic nuclei (AGN) are also typically strongly absorbed at high photon energies, but the enhanced sensitivity of XMM-Newton provided for the first time the opportunity to measure the spectral indices of individual sources and to test the possibility that obscured AGN are responsible for a substantial portion of the cosmic X-ray background (CXRB). The new observations confirm and greatly extend the earlier results. Substantial intervening absorbing material is detected for 3 of the sources, and 2 additional targets show hard power-law continua. In addition, soft X-ray excesses are detected in 3 of sources, indicating the presence of extended regions of ionized gas. This component is-particularly well-defined in the Type 1 source 2MASS2344+1221, allowing analysis and modeling at a level of detail unusual for such distant sources. An important finding that parallels conclusions from optical polarimetry is the lack of dependence of absorption on optical spectral class (Type 1 or 2). The combination of strong polarization and X-ray absorption in sources that show strong, broad emission lines indicates either a very small (nuclear) absorber or a favored viewing angle which allows the X-ray source to be covered but the surrounding broad emission-line region to be largely exposed. The observed spectral also indicate that obscured AGN of both Type 1 and 2 contribute significantly to the CXRB at higher X-ray energies.

Schmidt, Gary D.↗

Detection and Screening of Organic Contaminants in A Riverine System of Georgia Using Non-Targeted Analysis

Numerous organic chemicals exist within aquatic environments, yet effectively screening and prioritizing them is a huge challenge. This study provides a comprehensive investigation into the ecological dynamics of the North Oconee River within Athens-Clarke County, Georgia, with a specific focus on the distribution of 33 identified compounds, including a prominent pesticide. The research, conducted in the riverine ecosystems proximal to the Firefly trail, employs advanced analytical techniques to elucidate potential contamination sources arising from agricultural and urban runoff. Intriguingly, the study reveals North Oconee River near the Firefly Trail as a notable site for heightened pesticide contamination, warranting a meticulous exploration of its origins. Furthermore, the investigation unveils the intricate microbial degradation processes of malathion within the North Oconee River, elucidating the pivotal role played by microbial activity in river water. The detection of degradant byproducts prompts the considerations of bioavailability and toxicity, associating potential implications for the river’s overall ecological health. Ongoing research endeavors to precisely quantify environmental risks and unravel indigenous microbial degradation pathways, presenting pivotal contributions to the scientific community’s understanding of complex riverine ecosystems. This research serves as a foundational piece in informing sustainable environmental management practices and emphasizes the urgency of comprehensive stewardship in safeguarding aquatic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Spatial and Spatial Frequency Spreads of Masking: Measurements and A Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2, 4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 z 0 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, Joshua A.↗

Spatial and Spatial Frequency Spreads Of Masking: Measurements and a Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2,4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, J. A.↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Perceptual Repetition Blindness Effects

The phenomenon of repetition blindness (RB) may reveal a new limitation on human perceptual processing. Recently, however, researchers have attributed RB to post-perceptual processes such as memory retrieval and/or reporting biases. The standard rapid serial visual presentation (RSVP) paradigm used in most RB studies is, indeed, open to such objections. Here we investigate RB using a "single-frame" paradigm introduced by Johnston and Hale (1984) in which memory demands are minimal. Subjects made only a single judgement about whether one masked target word was the same or different than a post-target probe. Confidence ratings permitted use of signal detection methods to assess sensitivity and bias effects. In the critical condition for RB a precue of the post-target word was provided prior to the target stimulus (identity precue), so that the required judgement amounted to whether the target did or did not repeat the precue word. In control treatments, the precue was either an unrelated word or a dummy.

Hochhaus, Larry↗

Control of the Laser Interferometer Space Antenna

The detection of gravity waves will open a new window of observation on the universe. Unlike typical observatories, which detect electromagnetic waves traveling through space-time, the Laser Interferometer Space Antenna (LISA) will detect ripples in space-time itself. Science targets include galactic binaries, merging supermassive black holes, intermediate-mass/seed black holes, and cosmological backgrounds. Gravity waves are detected by measuring the strain in space, i.e. the change in distance between a set of masses (test masses or proof masses) separated by a great distance. Ground based detection of gravity waves by Laser Interferometer Gravitational Wave Observatory (LIGO) and other observatories are possible with laser interferometry; hut the relatively short arm length (4 km) and seismic noise limit the measurement band to above 10 Hz on Earth. LISA also uses laser interferometric measurement of the change in distance between test masses, but does it in space. Each LISA spacecraft embodies two test masses. Space allows very long arm lengths (5 million km for LISA) and a very quiet acceleration environment (3.5x10(exp -15) meters per second squared/Hertz (sup 0.5) for LISA), which allows for the detection of gravity wave strains to a best sensitivity of 3x10(exp -24) strain/Hertz (sup 0.5) over the measurement band of 10(exp -4) to 10(exp -1) Hertz for a one-year observation. The LISA mission consists of three spacecraft in heliocentric orbit. The orbits are chosen so that the three spacecraft form a roughly equilateral triangle with its center located at a radius of 1 AU and 20 degrees behind the Earth, as shown. Requirements are placed on the rotational and translational dynamics of each spacecraft to ensure that the proper sensitivity for science measurements can be achieved.

Maghami, Peiman↗

(abstract) Application of Neural Networks to Hyperspectral Unmixing

The emergence, in recent years, of hyperspectral sensors provides a tremendous opportunity for advancing the process of detailed and direct remote detection and identification from space of targets or surface materials. Such sensors exploit the uniqueness of the corresponding spectral reflectance signatures, which enables high resolution imaging spectrometer data to be processed on a pixel-by-pixel basis. This has implications both for defense-related applications (e.g., surveillance tasks) and in the civilian domain (e.g., for science applications). The purpose of this talk is to discuss a number of strong arguments that support neural networks as a choice for the generalized analysis (e.g., unmixing) of remotely sensed hyperspectral data.

signatures moving object detection surveillance co↗

Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject

Doppler radar node occupancy sensors are promising for applications in smart buildings due to their simple circuits and price advantage compared to quadrature radar sensors. However, single-channel sensitivity limitations may result in low sensitivity and misinterpreted motion rates if the detected subject is at or close to “null” points. We designed and tested a novel method to eliminate such limits, demonstrating that passive nodes can be used to detect a sedentary person regardless of position. This method is based on characteristics of chest motion due to respiration, found via both simulations and experiments based on a sinusoidal model and a more realistic model of cardiorespiratory motion. In addition, respiratory rate variability is considered to distinguish a true human presence from a mechanical target. Sensor node data were collected simultaneously with an infrared camera system, which provided a respiration signal reference, to test the algorithm with 19 human subjects and a mechanical target. The results indicate that a human presence was detected with 100% accuracy and successfully differentiated from a mechanical target in a controlled environment. The developed method can greatly improve the occupancy detection accuracy of single-channel radar-based occupancy sensors and facilitate their adoption in smart building applications.

Song, Chenyan↗

A New Approach to Micro-arcsecond Astrometry with SIM Allowing Early Mission Narrow Angle Measurements of Compelling Astronomical Targets

The Space Interferometry Mission (SIM) is capable of detecting and measuring the mass of terrestrial planets around stars other than our own. It can measure the mass of black holes and the visual orbits of radio and x-ray binary sources. SIM makes possible a new level of understanding of complex astrophysical processes. SIM achieves its high precision in the so-called narrow-angle regime. This is defined by a 1 degree diameter field in which the position of a target star is measured with respect to a set of reference stars. The observation is performed in two parts: first, SIM observes a grid of stars that spans the full sky. After a few years, repeated observations of the grid allow one to determine the orientation of the interferometer baseline. Second, throughout the mission, SIM periodically observes in the narrow-angle mode. Every narrow-angle observation is linked to the grid to determine the precise attitude and length of the baseline. The narrow angle process demands patience. It is not until five years after launch that SIM achieves its ultimate accuracy of 1 microarcsecond. The accuracy is degraded by a factor of approx. 2 at mid-mission. Our work proposes a technique for narrow angle astrometry that does not rely on the measurement of grid stars. This technique, called Gridless Narrow Angle Astrometry (GNAA) can obtain microarcsecond accuracy and can detect extra-solar planets and other exciting objects with a few days of observation. It can be applied as early as during the first six months of in-orbit calibration (IOC). The motivations for doing this are strong. First, and obviously, it is an insurance policy against a catastrophic mid-mission failure. Second, at the start of the mission, with several space-based interferometers in the planning or implementation phase, NASA will be eager to capture the public's imagination with interferometric science. Third, early results and a technique that can duplicate those results throughout the mission will give the analysts important experience in the proper use and calibration of SIM.

Shaklan, Stuart↗

Sequential Perturbation-based FDIA Detection using DERs for Unbalanced Distribution System

The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.

Attack Detection↗

Selective attention and the auditory vertex potential. I - Effects of stimulus delivery rate. II - Effects of signal intensity and masking noise

The effects of varying the rate of delivery of dichotic tone pip stimuli on selective attention measured by evoked-potential amplitudes and signal detectability scores were studied. The subjects attended to one channel (ear) of tones, ignored the other, and pressed a button whenever occasional targets - tones of a slightly higher pitch were detected in the attended ear. Under separate conditions, randomized interstimulus intervals were short, medium, and long. Another study compared the effects of attention on the N1 component of the auditory evoked potential for tone pips presented alone and when white noise was added to make the tones barely above detectability threshold in a three-channel listening task. Major conclusions are that (1) N1 is enlarged to stimuli in an attended channel only in the short interstimulus interval condition (averaging 350 msec), (2) N1 and P3 are related to different modes of selective attention, and (3) attention selectivity in multichannel listening task is greater when tones are faint and/or difficult to detect.

Schwent, V. L.↗

Detection in fixed and random noise in foveal and parafoveal vision explained by template learning

Foveal and parafoveal contrast detection thresholds for Gabor and checkerboard targets were measured in white noise by means of a two-interval forced-choice paradigm. Two white-noise conditions were used: fixed and twin. In the fixed noise condition a single noise sample was presented in both intervals of all the trials. In the twin noise condition the same noise sample was used in the two intervals of a trial, but a new sample was generated for each trial. Fixed noise conditions usually resulted in lower thresholds than twin noise. Template learning models are presented that attribute this advantage of fixed over twin noise either to fixed memory templates' reducing uncertainty by incorporation of the noise or to the introduction, by the learning process itself, of more variability in the twin noise condition. Quantitative predictions of the template learning process show that it contributes to the accelerating nonlinear increase in performance with signal amplitude at low signal-to-noise ratios.

NASA Center ARC↗

Photodiode Preamplifier for Laser Ranging With Weak Signals

An improved preamplifier circuit has been designed for processing the output of an avalanche photodiode (APD) that is used in a high-resolution laser ranging system to detect laser pulses returning from a target. The improved circuit stands in contrast to prior such circuits in which the APD output current pulses are made to pass, variously, through wide-band or narrow-band load networks before preamplification. A major disadvantage of the prior wide-band load networks is that they are highly susceptible to noise, which degrades timing resolution. A major disadvantage of the prior narrow-band load networks is that they make it difficult to sample the amplitudes of the narrow laser pulses ordinarily used in ranging. In the improved circuit, a load resistor is connected to the APD output and its value is chosen so that the time constant defined by this resistance and the APD capacitance is large, relative to the duration of a laser pulse. The APD capacitance becomes initially charged by the pulse of current generated by a return laser pulse, so that the rise time of the load-network output is comparable to the duration of the return pulse. Thus, the load-network output is characterized by a fast-rising leading edge, which is necessary for accurate pulse timing. On the other hand, the resistance-capacitance combination constitutes a lowpass filter, which helps to suppress noise. The long time constant causes the load network output pulse to have a long shallow-sloping trailing edge, which makes it easy to sample the amplitude of the return pulse. The output of the load network is fed to a low-noise, wide-band amplifier. The amplifier must be a wide-band one in order to preserve the sharp pulse rise for timing. The suppression of noise and the use of a low-noise amplifier enable the ranging system to detect relatively weak return pulses.

Abramovici, Alexander↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4-Dioxane

Poly- and perfluoroalkyl substances (PFAS) and 1,4-dioxane are persistent emerging contaminants that are currently under consideration for federal and state-specific regulations in drinking water. Both PFAS and 1,4-dioxane are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Results from the Unregulated Contaminant Monitoring Rule 3 survey showed that >540 sites across the nation are contaminated with both PFAS and 1,4-dioxane. Hence, there is a need to identify technologies that can effectively remove both these contaminants. Water treatment via electron beam (e-beam) has been proven effective at treating a wide range of contaminants, including perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), polychlorinated biphenyls, and trichloroethylene. While the e-beam process is often considered similar to advanced oxidation processes (AOPs), e-beam technology is unique in that it produces both highly oxidizing and reducing species at the same time. The specific objectives of this study were to: (i) determine the effectiveness of 9 MeV electrons provided by the Fermilab’s Accelerator Application Development and Demonstration (A2D2) tool to decompose PFAS and 1,4-dioxane; (ii) assess the formation of byproducts during water treatment; (iii) apply the optimized treatment to field groundwater samples contaminated with PFAS and 1,4-dioxane, and (iv) assess the energy demands for the treatment of these contaminants using e-beam. Results from this study showed that e-beam is effective in treating both 1,4-dioxane and PFAS. Complete degradation of 1,4-dioxane was observed at a dose of 5 kGy for an initial concentration of up to 1 ppm without the need for any sample modification. The electrical energy per order (EEo) for treatment of 1,4-dioxane ranged from 0.46 to 0.72 kWh/m 3 /order and was comparable and even lower, in some cases, than other AOP technologies. Alkaline conditions (pH 13) and low dissolved oxygen concentration (2 mg/L) highly favored the treatment of PFAS by e-beam. Greater than 90% removal of PFOA and PFOS from an initial concentration of 100 to 500 ppb was achieved at a dose of 250 kGy and 500 kGy, respectively, under optimized conditions. The degradation efficiency was not significantly changed when treating other PFAS of fluorinated carbon chain length of 5 to 7 individually at 250 kGy with a removal ranging from 85¬–99% for different compounds. Short chain PFAS (perfluorobutanoate: PFBA and perfluorobutane sulfonate: PFBS) did not degrade under the same conditions at 250 kGy, but 70 to 99% degradation was observed at a higher dose of 1000 kGy. Short chain PFAS (perfluorohexanoate: PFHxA (C5) and perfluoroheptanoate: PFHpA (C6)) were detected after treatment of PFOA, but not after PFOS treatment. Inability to close the mass balance through targeted analysis suggests the presence of other intermediates not detectable by available analytical methods. When treating PFAS mixture containing ten compounds at equimolar concentration of 0.05 µM each, preferential degradation of polyfluorinated compound (6:2 fluorotelomer sulfonate or 6:2 FTS) followed by C8 and C7 compounds was observed as a function of increasing e-beam dose. About 30% degradation of ΣPFAS was observed at 250 kGy and no further removal was observed up to a dose of 1000 kGy. C4 to C6 PFASs showed no degradation, while C3 PFAS (PFBS) showed an increase in concentration by 34% at 1000 kGy due to formation from the breakdown of other long chain PFAS. These results suggested that (a) the reaction kinetics is likely different for different PFAS based on chain length, functional group, and the degree of fluorination of the carbon chain, and (b) there may be intermediates generated from the degradation of 6:2 FTS and C7/C8 compounds that can potentially scavenge hydrated electrons needed for reaction with the untreated PFAS molecules. Treatment of three PFAS-contaminated groundwater samples from two US states showed similar trends as observed in the treatment of equimolar PFAS mixtures. Up to 71% removal of ΣPFAS was achieved in real groundwater samples at 750 kGy and data trend suggested that higher degradation is feasible if higher doses (>1MGy) are applied to treat field samples to overcome matrix effects and competing species. Calculated EEo for PFAS ranged from as low as ~48 to 1081 kWh/m 3 /order depending on the type of PFAS treated. These values are comparable and even lower, in some cases, than other destructive technologies employed for PFAS treatment such as ultrasound, plasma, and photochemical treatment. The results from this study indicate e-beam is a promising approach under favorable conditions and should be explored further as an end-of-train treatment option for PFAS destruction.

1,4-Dioxane↗

Two-Photon Flow Cytometry

Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

Zhog, Cheng Frank↗